22dade917f556301f62fb1674a333d4f23be0d2d
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
10    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
11    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
12    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
13    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
14    1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
15    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
16    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17    1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
18    1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
19    1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
20 1. [Server Management](#server-management)
21    1. [Requirements](#requirements)
22    1. [Addressing](#addressing)
23    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
24    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
25 1. [Server Specifications](#server-specifications)
26    1. [Server Types](#server-types)
27    1. [Naming Convention](#naming-convention)
28 1. [Testbeds Configuration](#testbeds-configuration)
29    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
30       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
31       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
32       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
33       1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
34       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
35       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
36       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
37       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
38       1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
39       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
40       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
41       1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
42       1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
43       1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
44    1. [Per Testbed Wiring](#per-testbed-wiring)
45       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
46       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
47       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
48       1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
49       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
50       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
51       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
52       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
53       1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
54       1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
55       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
56       1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
57       1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
58       1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
59 1. [Inventory](#inventory)
60    1. [Appliances](#appliances)
61    1. [Arm Servers](#arm-servers)
62    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
63    1. [Network Interface Cards](#network-interface-cards)
64    1. [Pluggables and Cables](#pluggables-and-cables)
65    1. [Other Parts](#other-parts)
66
67 ## Purpose
68
69 This note includes specification of the physical testbed infrastructure
70 hosted by LFN FD.io CSIT project.
71
72 ## Testbeds Overview
73
74 ### Summary List
75
76 ```
77  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
78  1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0    0
79  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0    0
80  3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0    0
81  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0    0    0
82  5. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    0    0    2    0    0    0    0
83  6. 2-Node-Skylake     perf   skx   skx   3    3    3    0    6    0    0    0    0    0    0    0    0    0    0
84  7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0    0    0
85  8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0    0
86  9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0    0    0
87 10. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0    0    0
88 11. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    0    8    0
89 12. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0    0
90 13. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0    0
91 14. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0    0    0
92 15. 3-Node-Altra       perf   alt   icx   1    2    1    0    0    0    0    0    0    0    2    0    0    1    0
93 16. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0    0    0
94 17. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2    0    0
95 18. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    0    0    6    0
96 19. 3-Node-SnowRidge   perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    0    0    .5   2
97                                  Totals: 34   44  21.5   4   17    1    2    3    3    2    4    7    2  15.5   2
98 ```
99
100 ### 1-Node-Skylake Xeon Intel (1n-skx)
101
102 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
103 ports connected back-to-back ([Server Types](#server-types)).
104 Used for FD.io VPP_Device functional driver tests.
105
106 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
107
108 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
109 ports connected back-to-back ([Server Types](#server-types)).
110 Used for FD.io VPP_Device functional driver tests.
111
112 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
113
114 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
115 NIC ports connected back-to-back ([Server Types](#server-types)).
116
117 Used for FD.io VPP_Device functional driver tests.
118
119 ### 2-Node-Denverton Atom Intel (2n-dnv)
120
121 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
122 TG (Server-Type-B2) connected in a 2-node circular topology
123 ([Server Types](#server-types)).
124 Used for FD.io performance tests.
125
126 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
127
128 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
129 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
130 circular topology ([Server Types](#server-types)).
131 Used for FD.io TCP/IP and HTTP performance tests.
132
133 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
134
135 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
136 one TG (Server-Type-C3) connected in a 2-node circular topology
137 ([Server Types](#server-types)).
138 Used for FD.io performance tests.
139
140 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
141
142 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
143 one TG (Server-Type-D2) connected in a 2-node circular topology
144 ([Server Types](#server-types)).
145 Used for FD.io performance tests.
146
147 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
148
149 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
150 one TG (Server-Type-E31) connected in a 2-node circular topology
151 ([Server Types](#server-types)).
152 Used for FD.io performance tests.
153
154 ### 2-Node-Icelake Xeon Intel (2n-icx)
155
156 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
157 one TG (Server-Type-F2) connected in a 2-node circular topology
158 ([Server Types](#server-types)).
159 Used for FD.io performance tests.
160
161 ### 3-Node-Haswell Xeon Intel (3n-hsw)
162
163 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
164 TG (Server-Type-A2) connected in a 3-node circular topology
165 ([Server Types](#server-types)).
166 Used for FD.io performance tests.
167
168 ### 3-Node-Rangeley Atom Testbeds
169
170 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
171 TG (Server-Type-2) connected in a 3-node circular topology
172 ([Server Types](#server-types)).
173 Used for FD.io performance tests.
174
175 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
176
177 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
178 TG (Server-Type-E31) connected in a 3-node circular topology
179 ([Server Types](#server-types)).
180 Used for FD.io performance tests.
181
182 ### 3-Node-Altra Arm Ampere (3n-alt)
183
184 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
185 TG (Server-Type-F4) connected in a 3-node circular topology
186 ([Server Types](#server-types)).
187 Used for FD.io performance tests.
188
189 ### 3-Node-Icelake Xeon Intel (3n-icx)
190
191 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
192 TG (Server-Type-F3) connected in a 3-node circular topology
193 ([Server Types](#server-types)).
194 Used for FD.io performance tests.
195
196 ### 3-Node-SnowRidge Atom Intel (3n-snr)
197
198 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
199 TG (Server-Type-F4) connected in a 3-node circular topology
200 ([Server Types](#server-types)).
201 Used for FD.io performance tests.
202
203
204 ## Server Management
205
206 ### Requirements
207
208 For management purposes, each server must have following two ports
209 connected to the management network:
210
211 ```
212 - 1GE IPMI port
213   - IPMI - Intelligent Platform Management Interface.
214   - Required for access to embedded server management with WebUI, CLI,
215     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
216 - 1GE/10GE/40GE management port
217   - hostOS management port for general system management.
218 ```
219
220 ### Addressing
221
222 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
223 Management port, which are connected to two different VLANs.
224
225 ```
226 1. LOM (IPMI) VLAN:
227     - Subnet: 10.30.50.0/24
228     - Gateway: 10.30.50.1
229     - Broadcast: 10.30.50.255
230     - DNS1: 199.204.44.24
231     - DNS2: 199.204.47.54
232 2. Management Vlan:
233     - Subnet: 10.30.51.0/24
234     - Gateway: 10.30.51.1
235     - Broadcast: 10.30.51.255
236     - DNS1: 199.204.44.24
237     - DNS2: 199.204.47.54
238 ```
239
240 To access these hosts, VPN connection is required.
241
242 ### LOM (IPMI) VLAN IP Addresses
243
244 Name         | Comment
245 ------------ | -------
246 10.30.50.0   | network
247 10.30.51.1   | Router
248 10.30.50.2   | LF Reserved
249 10.30.50.3   | LF Reserved
250 10.30.50.4   | LF Reserved
251 10.30.50.5   | LF Reserved
252 10.30.50.6   | LF Reserved
253 10.30.50.7   | LF Reserved
254 10.30.50.8   | LF Reserved
255 10.30.50.9   | LF Reserved
256 10.30.50.10  | LF Reserved
257 10.30.50.11  | LF Reserved
258 10.30.50.12  | LF Reserved
259 10.30.50.13  | LF Reserved
260 10.30.50.14  | LF Reserved
261 10.30.50.15  | LF Reserved
262 10.30.50.16  | s16-nomad
263 10.30.50.17  | s17-nomad
264 10.30.50.18  | s18-nomad
265 10.30.50.19  | s19-nomad
266 10.30.50.20  | s20-nomad
267 10.30.50.21  | s21-nomad
268 10.30.50.22  | s22-nomad
269 10.30.50.23  | s23-nomad
270 10.30.50.24  | s24-nomad
271 10.30.50.25  | s25-nomad
272 10.30.50.26  | s26-nomad
273 10.30.50.36  | s17-t33-sut1
274 10.30.50.37  | s18-t33-sut2
275 10.30.50.38  | fdio-marvell-dev
276 10.30.50.41  | s3-t21-sut1
277 10.30.50.42  | s4-t21-tg1
278 10.30.50.43  | s11-t31-sut1
279 10.30.50.44  | s12-t31-sut2
280 10.30.50.45  | s13-t31-tg1
281 10.30.50.46  | s19-t33t211-tg1
282 10.30.50.47  | s1-t11-sut1
283 10.30.50.48  | s2-t12-sut1
284 10.30.50.49  | s5-t22-sut1
285 10.30.50.50  | s6-t22-tg1
286 10.30.50.51  | s7-t23-sut1
287 10.30.50.52  | s8-t23-tg1
288 10.30.50.53  | s9-t24-sut1
289 10.30.50.54  | s10-t24-tg1
290 10.30.50.55  | s14-t32-sut1
291 10.30.50.56  | s15-t32-sut2
292 10.30.50.57  | s16-t32-tg1
293 10.30.50.58  | s25-t25-sut1
294 10.30.50.59  | s26-t25-tg1
295 10.30.50.69  | s27-t211-sut1
296 10.30.50.70  | s55-t13-sut1
297 10.30.50.71  | s56-t14-sut1
298 10.30.50.72  | s62-t34-sut1
299 10.30.50.73  | s63-t34-sut2
300 10.30.50.74  | s64-t34-tg1
301 10.30.50.75  | s65-t37-sut1
302 10.30.50.76  | s66-t37-sut2
303 10.30.50.77  | s67-t37-tg1
304 10.30.50.78  | s78-t38-sut1
305 10.30.50.79  | s79-t38-sut2
306 10.30.50.80  | s80-t38-tg1
307 10.30.50.81  | s71-t212-sut1
308 10.30.50.82  | s72-t212-tg1
309 10.30.50.83  | s83-t213-sut1
310 10.30.50.84  | s84-t213-tg1
311 10.30.50.85  | s85-t214-sut1
312 10.30.50.86  | s86-t214-tg1
313 10.30.50.87  | s87-t215-sut1
314 10.30.50.88  | s88-t215-tg1
315 10.30.50.89  | s89-t39t310-tg1
316 10.30.50.90  | s90-t311t312-tg1
317 10.30.50.91  | s91-nomad
318 10.30.50.92  | s92-nomad
319 10.30.50.93  | s93-t39-sut1
320 10.30.50.94  | s94-t39-sut2
321 10.30.50.255 | Broadcast
322 10.30.55.0   | network
323 10.30.55.1   | Router
324 10.30.55.10  | s28-t26t35-tg1
325 10.30.55.11  | s29-t26-sut1
326 10.30.55.12  | s30-t35-sut1
327 10.30.55.13  | s31-t35-sut2
328 10.30.55.18  | s33-t27-sut1
329 10.30.55.19  | s34-t27-tg1
330 10.30.55.20  | s35-t28-sut1
331 10.30.55.21  | s36-t28-tg1
332 10.30.55.22  | s37-t29-sut1
333 10.30.55.23  | s38-t29-tg1
334 10.30.55.24  | s60-t210-sut1
335 10.30.55.25  | s61-t210-tg1
336 10.30.55.255 | Broadcast
337
338 ### Management VLAN IP Addresses
339
340 Name         | Comment
341 -------------| -------
342 10.30.51.0   | network
343 10.30.51.1   | Router
344 10.30.51.2   | LF Reserved
345 10.30.51.3   | LF Reserved
346 10.30.51.4   | LF Reserved
347 10.30.51.5   | LF Reserved
348 10.30.51.6   | LF Reserved
349 10.30.51.7   | LF Reserved
350 10.30.51.8   | LF Reserved
351 10.30.51.15  | LF Reserved
352 10.30.51.16  | s16-nomad
353 10.30.51.17  | s17-nomad
354 10.30.51.18  | s18-nomad
355 10.30.51.19  | s19-nomad
356 10.30.51.20  | s20-nomad
357 10.30.51.21  | s21-nomad
358 10.30.51.22  | s22-nomad
359 10.30.51.23  | s23-nomad
360 10.30.51.24  | s24-nomad
361 10.30.51.25  | s25-nomad
362 10.30.51.26  | s26-nomad
363 10.30.51.36  | s17-t33-sut1
364 10.30.51.37  | s18-t33-sut2
365 10.30.51.38  | fdio-marvell-dev
366 10.30.51.44  | s3-t21-sut1
367 10.30.51.45  | s4-t21-tg1
368 10.30.51.46  | s11-t31-sut1
369 10.30.51.47  | s12-t31-sut2
370 10.30.51.48  | s13-t31-tg1
371 10.30.51.49  | s19-t33t211-tg1
372 10.30.51.50  | s1-t11-sut1
373 10.30.51.51  | s2-t12-sut1
374 10.30.51.52  | s5-t22-sut1
375 10.30.51.53  | s6-t22-tg1
376 10.30.51.54  | s7-t23-sut1
377 10.30.51.55  | s8-t23-tg1
378 10.30.51.56  | s9-t24-sut1
379 10.30.51.57  | s10-t24-tg1
380 10.30.51.58  | s14-t32-sut1
381 10.30.51.59  | s15-t32-sut2
382 10.30.51.60  | s16-t32-tg1
383 10.30.51.61  | s25-t25-sut1
384 10.30.51.62  | s26-t25-tg1
385 10.30.51.69  | s27-t211-sut1
386 10.30.51.70  | s55-t13-sut1
387 10.30.51.71  | s56-t14-sut1
388 10.30.51.72  | s62-t34-sut1
389 10.30.51.73  | s63-t34-sut2
390 10.30.51.74  | s64-t34-tg1
391 10.30.51.75  | s65-t37-sut1
392 10.30.51.76  | s66-t37-sut2
393 10.30.51.77  | s67-t37-tg1
394 10.30.51.78  | s78-t38-sut1
395 10.30.51.79  | s79-t38-sut2
396 10.30.51.80  | s80-t38-tg1
397 10.30.51.81  | s71-t212-sut1
398 10.30.51.82  | s72-t212-tg1
399 10.30.51.83  | s83-t213-sut1
400 10.30.51.84  | s84-t213-tg1
401 10.30.51.85  | s85-t214-sut1
402 10.30.51.86  | s86-t214-tg1
403 10.30.51.87  | s87-t215-sut1
404 10.30.51.88  | s88-t215-tg1
405 10.30.51.89  | s89-t39t310-tg1
406 10.30.51.90  | s90-t311t312-tg1
407 10.30.51.91  | s91-nomad
408 10.30.51.92  | s92-nomad
409 10.30.51.93  | s93-t39-sut1
410 10.30.51.94  | s94-t39-sut2
411 10.30.51.255 | Broadcast
412 10.32.8.0    | network
413 10.32.8.1    | Router
414 10.32.8.10   | s28-t26t35-tg1
415 10.32.8.11   | s29-t26-sut1
416 10.32.8.12   | s30-t35-sut1
417 10.32.8.13   | s31-t35-sut2
418 10.32.8.18   | s33-t27-sut1
419 10.32.8.19   | s34-t27-tg1
420 10.32.8.20   | s35-t28-sut1
421 10.32.8.21   | s36-t28-tg1
422 10.32.8.22   | s37-t29-sut1
423 10.32.8.23   | s38-t29-tg1
424 10.32.8.24   | s60-t210-sut1
425 10.32.8.25   | s61-t210-tg1
426 10.32.8.255  | Broadcast
427
428 ## Server Specifications
429
430 ### Server Types
431
432 FD.io CSIT lab contains following server types:
433 ```
434 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
435     - Quantity: 6 servers.
436     - Physical connectivity:
437         - CIMC and host management ports.
438         - NIC ports connected in 3-node topologies.
439     - Main HW configuration:
440         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
441         - Processors: 2* E5-2699v3 2.3 GHz.
442         - RAM Memory: 16* 32GB DDR4-2133MHz.
443         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
444     - NICs configuration:
445         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
446             - PCIe Slot1: empty.
447             - PCIe Slot2: empty.
448             - PCIe Slot3: empty.
449         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
450             - PCIe Slot4: empty.
451             - PCIe Slot5: empty.
452             - PCIe Slot6: empty
453         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
454 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
455     - Quantity: 3 servers.
456     - Physical connectivity:
457         - CIMC and host management ports.
458         - NIC ports connected in 3-node topologies.
459     - Main HW configuration:
460         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
461         - Processors: 2* E5-2699v3 2.3 GHz.
462         - RAM Memory: 16* 32GB DDR4-2133MHz.
463         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
464     - NICs configuration:
465         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
466             - PCIe Slot1: empty.
467             - PCIe Slot2: empty.
468             - PCIe Slot3: empty.
469         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
470             - PCIe Slot4: empty.
471             - PCIe Slot5: empty.
472             - PCIe Slot6: empty
473         - MLOM slot: empty.
474 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
475     - Quantity: 3 servers.
476     - Physical connectivity:
477         - CIMC and host management ports.
478         - no NIC ports, standalone setup.
479     - Main HW configuration:
480         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
481         - Processors: 2* E5-2699v3 2.3 GHz.
482         - RAM Memory: 16* 32GB DDR4-2133MHz.
483         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
484     - NICs configuration:
485         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
486             - no cards.
487         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
488             - no cards.
489         - MLOM slot: empty.
490 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
491     - Quantity: ---
492     - Physical connectivity:
493         - IPMI and host management ports.
494         - NIC ports connected into 2-node and 3-node topologies.
495     - Main HW configuration:
496         - Chassis: SuperMicro SYS-7049GP-TRT.
497         - Motherboard: SuperMicro X11DPG-QT.
498         - Processors: 2* Intel Platinum 8180 2.5 GHz.
499         - RAM Memory: 16* 16GB DDR4-2666MHz.
500         - Disks: 2* 1.6TB 6G SATA SSD.
501     - NICs configuration:
502         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
503             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
504             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
505             - PCIe Slot9 5e:00.xx: empty.
506         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
507             - PCIe Slot6 86:00.xx: empty.
508             - PCIe Slot8 af:00.xx: empty.
509             - PCIe Slot10 d8:00.xx: empty.
510 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
511     - Quantity: ---
512     - Physical connectivity:
513         - IPMI and host management ports.
514         - NIC ports connected into 2-node and 3-node topologies.
515     - Main HW configuration:
516         - Chassis: SuperMicro SYS-7049GP-TRT.
517         - Motherboard: SuperMicro X11DPG-QT.
518         - Processors: 2* Intel Platinum 8180 2.5 GHz.
519         - RAM Memory: 16* 16GB DDR4-2666MHz.
520         - Disks: 2* 1.6TB 6G SATA SSD.
521     - NICs configuration:
522         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
523             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
524             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
525             - PCIe Slot9 5e:00.xx: empty.
526         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
527             - PCIe Slot6 86:00.xx: empty.
528             - PCIe Slot8 af:00.xx: empty.
529             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
530 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
531     - Quantity: TBD based on testbed allocation.
532     - Physical connectivity:
533         - Management: serial Port (usb) for console
534         - NIC ports connected into 2-node.
535     - Main HW configuration:
536         - Chassis: Netgate XG-2758-1u
537         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
538         - RAM Memory: 16GB ECC
539         - Disks: 150 GB
540     - NICs configuration:
541         - 2x 10Gb Intel 82599ES
542         - 4x 1GB Intel I354
543 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
544     - Quantity: 2.
545     - Physical connectivity:
546         - IPMI and host management ports.
547         - NIC ports connected into 1-node topologies.
548     - Main HW configuration:
549         - Chassis: SuperMicro SYS-7049GP-TRT.
550         - Motherboard: SuperMicro X11DPG-QT.
551         - Processors: 2* Intel Platinum 8180 2.5 GHz.
552         - RAM Memory: 16* 16GB DDR4-2666MHz.
553         - Disks: 2* 1.6TB 6G SATA SSD.
554     - NICs configuration:
555         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
556             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
557             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
558             - PCIe Slot9 5e:00.xx: empty.
559         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
560             - PCIe Slot6 86:00.xx: empty.
561             - PCIe Slot8 af:00.xx: empty.
562             - PCIe Slot10 d8:00.xx: empty.
563 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
564     - Quantity: 1.
565     - Physical connectivity:
566         - Host management interface: 10/100/1000-BaseT.
567         - 8-port 10GE SFP+ integrated NIC.
568     - Main HW configuration:
569         - Chassis: PS10GE4NG.
570         - Motherboard: SuperMicro X11DPG-QT.
571         - Processors: Quad-Core, Intel Processor.
572         - HW accelerators: FPGA offload.
573         - RAM Memory: 64GB.
574         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
575         - Physical Interfaces: 4 * 10GE SFP+.
576         - Operating System: Native IxOS.
577     - Interface configuration:
578         - Port-1: 10GE SFP+.
579         - Port-2: 10GE SFP+.
580         - Port-3: 10GE SFP+.
581         - Port-4: 10GE SFP+.
582 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
583     - Quantity: 1.
584     - Physical connectivity:
585         - IPMI and host management ports.
586         - NIC ports.
587     - Main HW configuration:
588         - Chassis: SuperMicro SYS-7049GP-TRT.
589         - Motherboard: SuperMicro X11DPG-QT.
590         - Processors: 2* Intel Platinum 8180 2.5 GHz.
591         - RAM Memory: 16* 16GB DDR4-2666MHz.
592         - Disks: 2* 1.6TB 6G SATA SSD.
593     - NICs configuration:
594         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
595             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
596             - PCIe Slot4 3b:00.xx: empty.
597             - PCIe Slot9 5e:00.xx: empty.
598         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
599             - PCIe Slot6 86:00.xx: empty.
600             - PCIe Slot8 af:00.xx: empty.
601             - PCIe Slot10 d8:00.xx: empty.
602 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
603     - Quantity: 4
604     - Physical connectivity:
605         - IPMI and host management ports.
606         - NIC ports.
607     - Main HW configuration:
608         - Chassis: SuperMicro SYS-E300-9A
609         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
610         - RAM Memory: 32GB ECC
611         - Disks: 480 GB
612     - NICs configuration:
613         - 2x 10Gb Intel x553 fiber ports
614         - 2x 10Gb Intel x553 copper ports
615         - 4x 1GB Intel I350 ports
616 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
617     - Quantity: 1.
618     - Physical connectivity:
619         - IPMI and host management ports.
620         - NIC ports connected into 1-node testbed topologies.
621     - Main HW configuration:
622         - Chassis: SuperMicro SYS-7049GP-TRT.
623         - Motherboard: SuperMicro X11DPG-QT.
624         - Processors: 2* Intel Platinum 8280 2.7 GHz.
625         - RAM Memory: 12* 16GB DDR4-2933.
626         - Disks: 2* 1.92TB SATA SSD.
627     - NICs configuration:
628         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
629             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
630             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
631             - PCIe Slot9 5e:00.xx: empty.
632         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
633             - PCIe Slot6 86:00.xx: empty.
634             - PCIe Slot8 af:00.xx: empty.
635             - PCIe Slot10 d8:00.xx: empty.
636 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
637     - Quantity: 3
638     - Physical connectivity:
639         - IPMI and host management ports.
640         - NIC ports connected into 2-node testbed topologies.
641     - Main HW configuration:
642         - Chassis: SuperMicro SYS-7049GP-TRT.
643         - Motherboard: SuperMicro X11DPG-QT.
644         - Processors: 2* Intel Gold 6252N 2.3 GHz.
645         - RAM Memory: 12* 16GB DDR4-2933.
646         - Disks: 2* 1.92TB SATA SSD.
647     - NICs configuration:
648         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
649             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
650             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
651             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
652         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
653             - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
654             - PCIe Slot8 af:00.xx: empty.
655             - PCIe Slot10 d8:00.xx: empty.
656 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
657     - Quantity: 3.
658     - Physical connectivity:
659         - IPMI and host management ports.
660         - NIC ports connected into 2-node testbed topologies.
661     - Main HW configuration:
662         - Chassis: SuperMicro SYS-7049GP-TRT.
663         - Motherboard: SuperMicro X11DPG-QT.
664         - Processors: 2* Intel Platinum 8280 2.7 GHz.
665         - RAM Memory: 12* 16GB DDR4-2933.
666         - Disks: 2* 1.92TB SATA SSD.
667     - NICs configuration:
668         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
669             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
670             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
671             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
672         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
673             - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
674             - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
675             - PCIe Slot10 d8:00.xx: empty.
676 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
677     - Quantity: 3.
678     - Physical connectivity:
679         - IPMI and host management ports.
680         - no NIC ports, standalone setup.
681     - Main HW configuration:
682         - Chassis: SuperMicro 1029P-WTRT.
683         - Motherboard: SuperMicro X11DDW-NT.
684         - Processors: 2* Intel Platinum 8280 2.7 GHz.
685         - RAM Memory: 12* 16GB DDR4-2933.
686         - Disks: 4* 1.92TB SATA SSD.
687     - NICs configuration:
688         - Numa0:
689             - no cards.
690         - Numa1:
691             - no cards.
692 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
693     - Quantity: 1.
694     - Physical connectivity:
695         - IPMI and host management ports.
696         - NIC ports connected into 2-node testbed topologies.
697     - Main HW configuration:
698         - Chassis: SuperMicro AS-1114S-WTRT
699         - Processors: 1* AMD EPYC 7532 2.4 GHz.
700         - RAM Memory: 8* 32GB DDR4-2933.
701         - Disks: 1* 1TB SATA SSD.
702     - NICs configuration:
703         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
704             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
705             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
706             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
707 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
708     - Quantity: 1.
709     - Physical connectivity:
710         - IPMI and host management ports.
711         - NIC ports connected into 2-node testbed topologies.
712     - Main HW configuration:
713         - Chassis: SuperMicro AS-1114S-WTRT
714         - Processors: 1* AMD EPYC 7532 2.4 GHz.
715         - RAM Memory: 8* 32GB DDR4-2933.
716         - Disks: 1* 1TB SATA SSD.
717     - NICs configuration:
718         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
719             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
720             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
721             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
722 17.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
723     - Quantity: 2
724     - Physical connectivity:
725         - IPMI and host management ports.
726         - NIC ports connected into 1-node topologies.
727     - Main HW configuration:
728         - Chassis: GIGABYTE Rack Mount
729         - Motherboard: MT91-FS4-00
730         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
731         - RAM Memory: 16 * 16GB DIMM
732         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
733     - NICs configuration:
734         - Numa0:
735             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
736             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
737         - Numa1:
738             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
739             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
740 18.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
741     - Quantity: 2
742     - Physical connectivity:
743         - IPMI(?) and host management ports.
744         - NIC ports connected into 3-node topology.
745     - Main HW configuration:
746         - Chassis: Huawei TaiShan 2280.
747         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
748         - RAM Memory: 8* 16GB DDR4-2400MT/s
749         - Disks: 1* 4TB SATA HDD
750     - NICs configuration:
751         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
752         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
753 19.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
754     - Quantity: 1
755     - Physical connectivity:
756         - IPMI and host management ports.
757         - NIC ports connected into 2-node topologies.
758     - Main HW configuration:
759         - Chassis: Gigabyte R181-T90 1U
760         - Motherboard: MT91-FS1
761         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
762         - RAM Memory: 4* 32GB RDIMM
763         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
764     - NICs configuration:
765         - Numa0:
766             - no cards
767         - Numa1:
768             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
769 20.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
770     - Quantity: 2
771     - Physical connectivity:
772         - IPMI and host management ports.
773         - NIC ports connected into 3-node topologies.
774     - Main HW configuration:
775         - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
776         - Motherboard: Mt.Jade Motherboard
777         - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
778         - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
779         - RAM Memory: 16* 8GB DDR4-3200MT/s
780         - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
781     - NICs configuration:
782         - Numa0:
783             - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
784         - Numa1:
785             - no cards.
786 21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
787     - Quantity: 2.
788     - Physical connectivity:
789         - IPMI and host management ports.
790     - Main HW configuration:
791         - Chassis: Gigabyte R152-P30-00 1U
792         - Motherboard: MP32-AR1-00
793         - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
794         - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
795         - RAM Memory: 12* 16GB DDR4-3200MT/s
796         - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
797 22.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
798     - Quantity: 1
799     - Physical connectivity:
800         - IPMI and host management ports.
801         - NIC ports connected into 2-node and 3-node topologies.
802     - Main HW configuration:
803         - Chassis: SuperMicro SYS-7049GP-TRT.
804         - Motherboard: SuperMicro X11DPG-QT.
805         - Processors: 2* Intel Platinum 8180 2.5 GHz.
806         - RAM Memory: 16* 16GB DDR4-2666MHz.
807         - Disks: 2* 1.6TB 6G SATA SSD.
808     - NICs configuration:
809         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
810             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
811             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
812             - PCIe Slot9 5e:00.xx: empty.
813         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
814             - PCIe Slot6 86:00.xx: empty.
815             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
816             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
817 23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
818     - Quantity: 8.
819     - Physical connectivity:
820         - IPMI and host management ports.
821         - NIC ports connected into 2-node or 3-node testbed topologies.
822     - Main HW configuration:
823         - Chassis: SuperMicro SYS-740GP-TNRT.
824         - Motherboard: Super X12DPG-QT6.
825         - Processors: 2* Intel Platinum 8358 2.6 GHz.
826         - RAM Memory: 16* 16GB DDR4-3200.
827         - Disks: 2* 960GB SATA SSD.
828     - NICs configuration:
829         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
830             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
831             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
832             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
833         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
834             - PCIe Slot6 86:00.xx: empty.
835             - PCIe Slot8 af:00.xx: empty.
836             - PCIe Slot10 d8:00.xx: empty.
837 24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
838     - Quantity: 3.
839     - Physical connectivity:
840         - IPMI and host management ports.
841         - NIC ports connected into 2-node testbed topologies.
842     - Main HW configuration:
843         - Chassis: SuperMicro SYS-740GP-TNRT.
844         - Motherboard: Super X12DPG-QT6.
845         - Processors: 2* Intel Platinum 8358 2.6 GHz.
846         - RAM Memory: 16* 16GB DDR4-3200.
847         - Disks: 2* 960GB SATA SSD.
848     - NICs configuration:
849         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
850             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
851             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
852             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
853         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
854             - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
855             - PCIe Slot8 af:00.xx: empty.
856             - PCIe Slot10 d8:00.xx: empty.
857 25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
858     - Quantity: 3.
859     - Physical connectivity:
860         - IPMI and host management ports.
861         - NIC ports connected into 3-node testbed topologies.
862     - Main HW configuration:
863         - Chassis: SuperMicro SYS-740GP-TNRT.
864         - Motherboard: Super X12DPG-QT6.
865         - Processors: 2* Intel Platinum 8358 2.6 GHz.
866         - RAM Memory: 16* 16GB DDR4-3200.
867         - Disks: 2* 960GB SATA SSD.
868     - NICs configuration:
869         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
870             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
871             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
872             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
873         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
874             - PCIe Slot6 86:00.xx: empty.
875             - PCIe Slot8 af:00.xx: empty.
876             - PCIe Slot10 d8:00.xx: empty.
877 26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
878     - Quantity: 3.
879     - Physical connectivity:
880         - IPMI and host management ports.
881         - NIC ports connected into 2-node and/or 3-node testbed topologies.
882     - Main HW configuration:
883         - Chassis: SuperMicro SYS-740GP-TNRT.
884         - Motherboard: Super X12DPG-QT6.
885         - Processors: 2* Intel Platinum 8358 2.6 GHz.
886         - RAM Memory: 16* 16GB DDR4-3200.
887         - Disks: 2* 960GB SATA SSD.
888     - NICs configuration:
889         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
890             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
891             - PCIe Slot4 3b:00.xx: empty.
892             - PCIe Slot9 5e:00.xx: empty.
893         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
894             - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
895             - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
896             - PCIe Slot10 d8:00.xx: empty.
897 27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
898     - Quantity: 2
899     - Physical connectivity:
900         - IPMI and host management ports.
901         - NIC ports connected into 3-node testbed topology.
902     - Main HW configuration:
903         - Chassis: Intel JACOBSVILLE SDP.
904         - Motherboard: Intel JACOBSVILLE E63448-400.
905         - Processors: 1* Intel Atom P5362B 2.2 GHz.
906         - RAM Memory: 2* 16GB DDR4-2933.
907         - Disks: ?* ? SATA SSD.
908     - NICs configuration:
909         - Numa0: (x16, PCIe3.0 lane)
910             - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
911 ```
912
913 ### Naming Convention
914
915 Following naming convention is used within this page to specify physical
916 connectivity and wiring across defined CSIT testbeds:
917
918 ```
919 - testbedname: testbedN.
920 - hostname:
921     - traffic-generator: tN-tgW.
922     - system-under-testX: tN-sutX.
923 - portnames:
924     - tN-tgW-cY/pZ.
925     - tN-sutX-cY/pZ.
926 - where:
927     - N - testbed number.
928     - tgW - server acts as traffic-generator with W index.
929     - sutX - server acts as system-under-test with X index.
930     - Y - PCIe slot number denoting a NIC card number within the host.
931     - Z - port number on the NIC card.
932 ```
933
934 ## Testbeds Configuration
935
936 ### Per Testbed Server Allocation and Naming
937
938 #### 1-Node-Skylake Servers (1n-skx) PROD
939
940 ```
941 - SUT [Server-Type-B6]:
942     - testbedname: testbed11.
943     - hostname: s1-t11-sut1.
944     - IPMI IP: 10.30.50.47
945     - Host IP: 10.30.51.50
946     - portnames:
947         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
948         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
949         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
950         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
951         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
952         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
953         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
954         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
955 - SUT [Server-Type-B6]:
956     - testbedname: testbed12.
957     - hostname: s2-t12-sut1.
958     - IPMI IP: 10.30.50.48
959     - Host IP: 10.30.51.51
960     - portnames:
961         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
962         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
963         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
964         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
965         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
966         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
967         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
968         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
969 ```
970
971 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
972
973 ```
974 - SUT [Server-Type-E11]:
975     - testbedname: testbed13
976     - hostname: s55-t13-sut1
977     - IPMI IP: 10.30.50.70
978     - Host IP: 10.30.51.70
979     - portnames:
980         - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
981         - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
982         - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
983         - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
984         - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
985         - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
986         - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
987         - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
988 - SUT [Server-Type-E11]:
989     - testbedname: testbed14
990     - hostname: s56-t14-sut1
991     - IPMI IP: 10.30.50.71
992     - Host IP: 10.30.51.71
993     - portnames:
994         - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
995         - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
996         - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
997         - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
998         - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
999         - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1000         - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1001         - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1002 ```
1003
1004 #### 1-Node-Cascadelake Servers (1n-clx) PROD
1005
1006 ```
1007 - SUT [Server-Type-C1]:
1008     - testbedname: testbed11.
1009     - hostname: s32-t14-sut1.
1010     - IPMI IP: 10.30.55.17
1011     - Host IP: 10.32.8.17
1012     - portnames:
1013         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1014         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1015         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1016         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1017         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
1018         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
1019         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
1020         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
1021 ```
1022
1023 #### 2-Node-Denverton Servers (2n-dnv) PROD
1024
1025 Note: ServerB28 (TG) is shared between testbed26 & testbed35
1026
1027 ```
1028 - TG [Server-Type-B2]:
1029     - testbednames: testbed26 and testbed35.
1030     - hostname: s28-t26t35-tg1.
1031     - IPMI IP: 10.30.55.10
1032     - Host IP: 10.32.8.10
1033     - portnames:
1034         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
1035         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
1036         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
1037         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
1038         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
1039         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
1040         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1041         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1042         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1043         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1044         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1045         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1046 - SUT [Server-Type-B10]:
1047     - testbednames: testbed26.
1048     - hostname: s29-t26-sut1.
1049     - IPMI IP: 10.30.55.11
1050     - Host IP: 10.32.8.11
1051     - portnames:
1052         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1053         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1054         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1055         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1056 ```
1057
1058 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1059
1060 ```
1061 - SUT [Server-Type-B8]:
1062     - testbedname: testbed25.
1063     - hostname: s25-t25-sut1.
1064     - IPMI IP: 10.30.50.58
1065     - Host IP: 10.30.51.61
1066     - portnames:
1067         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1068         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1069         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1070         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1071 - TG [Server-Type-B7]:
1072     - testbedname: testbed25.
1073     - hostname: s26-t25-tg1.
1074     - IPMI IP: 10.30.50.59
1075     - Host IP: 10.30.51.62
1076     - portnames:
1077         - s26-t25-tg1-p1 - 10GE-port1.
1078         - s26-t25-tg1-p2 - 10GE-port2.
1079         - s26-t25-tg1-p3 - 10GE-port3.
1080         - s26-t25-tg1-p4 - 10GE-port4.
1081 ```
1082
1083 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1084
1085 ```
1086 - SUT [Server-Type-C2]:
1087     - testbedname: testbed27.
1088     - hostname: s33-t27-sut1.
1089     - IPMI IP: 10.30.55.18
1090     - Host IP: 10.32.8.18
1091     - portnames:
1092         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1093         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1094         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1095         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1096         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1097         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1098         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1099         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1100         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1101         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1102 - TG [Server-Type-C3]:
1103     - testbedname: testbed27.
1104     - hostname: s34-t27-tg1.
1105     - IPMI IP: 10.30.55.19
1106     - Host IP: 10.32.8.19
1107     - portnames:
1108         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1109         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1110         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1111         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1112         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1113         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1114         - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1115         - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1116         - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1117         - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1118         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1119         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1120 - SUT [Server-Type-C2]:
1121     - testbedname: testbed28.
1122     - hostname: s35-t28-sut1.
1123     - IPMI IP: 10.30.55.20
1124     - Host IP: 10.32.8.20
1125     - portnames:
1126         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1127         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1128         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1129         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1130         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1131         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1132         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1133         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1134         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1135         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1136 - TG [Server-Type-C3]:
1137     - testbedname: testbed28.
1138     - hostname: s36-t28-tg1.
1139     - IPMI IP: 10.30.55.21
1140     - Host IP: 10.32.8.21
1141     - portnames:
1142         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1143         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1144         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1145         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1146         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1147         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1148         - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1149         - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1150         - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
1151         - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
1152         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1153         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1154 - SUT [Server-Type-C2]:
1155     - testbedname: testbed29.
1156     - hostname: s37-t29-sut1.
1157     - IPMI IP: 10.30.55.22
1158     - Host IP: 10.32.8.22
1159     - portnames:
1160         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1161         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1162         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1163         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1164         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1165         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1166         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1167         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1168         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1169         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1170 - TG [Server-Type-C3]:
1171     - testbedname: testbed29.
1172     - hostname: s38-t29-tg1.
1173     - IPMI IP: 10.30.55.23
1174     - Host IP: 10.32.8.23
1175     - portnames:
1176         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1177         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1178         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1179         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1180         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1181         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1182         - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
1183         - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
1184         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1185         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1186 ```
1187
1188 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1189
1190 ```
1191 - SUT [Server-Type-D1]:
1192     - testbedname: testbed210.
1193     - hostname: s60-t210-sut1.
1194     - IPMI IP: 10.30.55.24
1195     - Host IP: 10.32.8.24
1196     - portnames:
1197         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1198         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1199         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1200         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1201         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1202         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1203         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1204         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1205 - TG [Server-Type-D2]:
1206     - testbedname: testbed210.
1207     - hostname: s61-t210-tg1.
1208     - IPMI IP: 10.30.55.25
1209     - Host IP: 10.32.8.25
1210     - portnames:
1211         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1212         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1213         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1214         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1215         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1216         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1217         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1218         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1219 ```
1220
1221 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1222
1223 Note: Server19 (TG) is shared between testbed33 & testbed211
1224
1225 ```
1226 - SUT [Server-Type-E22]:
1227     - testbedname: testbed211.
1228     - hostname: s27-t211-sut1.
1229     - IPMI IP: 10.30.50.69
1230     - Host IP: 10.30.51.69
1231     - portnames:
1232         - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1233         - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1234 - TG [Server-Type-E31]:
1235     - testbedname: testbed33 and testbed211.
1236     - hostname: s19-t33t211-tg1.
1237     - IPMI IP: 10.30.50.46
1238     - Host IP: 10.30.51.49
1239     - portnames:
1240         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1241         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1242         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1243         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1244         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1245         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1246         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1247         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1248         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1249         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1250         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1251         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1252 ```
1253
1254 #### 2-Node-Icelake Servers (2n-icx) PROD
1255
1256 ```
1257 - SUT [Server-Type-F1]:
1258     - testbedname: testbed212.
1259     - hostname: s71-t212-sut1.
1260     - IPMI IP: 10.30.51.81
1261     - Host IP: 10.30.50.81
1262     - portnames:
1263         - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1264         - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1265         - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1266         - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1267         - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1268         - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1269         - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1270         - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1271 - TG [Server-Type-F2]:
1272     - testbedname: testbed212.
1273     - hostname: s72-t212-tg1.
1274     - IPMI IP: 10.30.51.82
1275     - Host IP: 10.30.50.82
1276     - portnames:
1277         - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1278         - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1279         - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1280         - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1281         - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1282         - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1283         - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1284         - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1285         - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1286         - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1287 - SUT [Server-Type-F1]:
1288     - testbedname: testbed213.
1289     - hostname: s83-t213-sut1.
1290     - IPMI IP: 10.30.51.83
1291     - Host IP: 10.30.50.83
1292     - portnames:
1293         - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1294         - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1295         - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1296         - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1297         - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1298         - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1299         - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1300         - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1301 - TG [Server-Type-F2]:
1302     - testbedname: testbed213.
1303     - hostname: s84-t213-tg1.
1304     - IPMI IP: 10.30.51.84
1305     - Host IP: 10.30.50.84
1306     - portnames:
1307         - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1308         - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1309         - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1310         - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1311         - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1312         - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1313         - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1314         - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1315         - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1316         - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1317 - SUT [Server-Type-F1]:
1318     - testbedname: testbed214.
1319     - hostname: s85-t214-sut1.
1320     - IPMI IP: 10.30.51.85
1321     - Host IP: 10.30.50.85
1322     - portnames:
1323         - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1324         - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1325         - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1326         - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1327         - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1328         - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1329         - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1330         - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1331 - TG [Server-Type-F2]:
1332     - testbedname: testbed214.
1333     - hostname: s86-t214-tg1.
1334     - IPMI IP: 10.30.51.86
1335     - Host IP: 10.30.50.86
1336     - portnames:
1337         - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1338         - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1339         - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1340         - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1341         - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1342         - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1343         - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1344         - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1345         - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1346         - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1347 - SUT [Server-Type-F1]:
1348     - testbedname: testbed215.
1349     - hostname: s87-t215-sut1.
1350     - IPMI IP: 10.30.51.87
1351     - Host IP: 10.30.50.87
1352     - portnames:
1353         - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1354         - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1355         - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1356         - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1357         - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1358         - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1359         - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1360         - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1361 - TG [Server-Type-F2]:
1362     - testbedname: testbed215.
1363     - hostname: s88-t215-tg1.
1364     - IPMI IP: 10.30.51.88
1365     - Host IP: 10.30.50.88
1366     - portnames:
1367         - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1368         - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1369         - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1370         - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1371         - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1372         - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1373         - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1374         - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1375         - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1376         - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1377 ```
1378
1379 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1380
1381 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1382
1383 ```
1384 - ServerB22 [Server-Type-B5]:
1385     - testbedname: testbed35.
1386     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1387     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1388     - Host IP: 10.30.51.9
1389     - portnames:
1390         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1391         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1392     - 1GB ports (tbd)
1393 - ServerB23 [Server-Type-B5]:
1394     - testbedname: testbed35.
1395     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1396     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1397     - Host IP: 10.30.51.10
1398     - portnames:
1399         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1400         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1401     - 1GB ports (tbd)
1402 - ServerB24 [Server-Type-B5]:
1403     - testbedname: testbed35.
1404     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1405     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1406     - Host IP: 10.30.51.11
1407     - portnames:
1408         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1409         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1410     - 1GB ports (tbd)
1411 ```
1412
1413 #### 3-Node-Taishan Servers (3n-tsh) PROD
1414
1415 Note: Server19 (TG) is shared between testbed33 & testbed211
1416
1417 ```
1418 - SUT [Server-Type-E21]:
1419     - testbedname: testbed33.
1420     - hostname: s17-t33-sut1.
1421     - IPMI IP: 10.30.50.36
1422     - Host IP: 10.30.51.36
1423     - portnames:
1424         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1425         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1426         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1427         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1428 - SUT [Server-Type-E21]:
1429     - testbedname: testbed33.
1430     - hostname: s18-t33-sut2.
1431     - IPMI IP: 10.30.50.37
1432     - Host IP: 10.30.51.37
1433     - portnames:
1434         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1435         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1436         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1437         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1438 - TG [Server-Type-E31]:
1439     - testbedname: testbed33 and testbed211.
1440     - hostname: s19-t33t211-tg1.
1441     - IPMI IP: 10.30.50.46
1442     - Host IP: 10.30.51.49
1443     - portnames:
1444         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1445         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1446         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1447         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1448         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1449         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1450         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1451         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1452         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1453         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1454         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1455         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1456 ```
1457
1458 #### 3-Node-Altra Servers (3n-alt) PROD
1459
1460 ```
1461 - SUT [Server-Type-E23]:
1462     - testbedname: testbed34.
1463     - hostname: s62-t34-sut1.
1464     - IPMI IP: 10.30.50.72
1465     - Host IP: 10.30.51.72
1466     - portnames:
1467         - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1468         - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1469 - SUT [Server-Type-E23]:
1470     - testbedname: testbed34.
1471     - hostname: s63-t34-sut2.
1472     - IPMI IP: 10.30.50.73
1473     - Host IP: 10.30.51.73
1474     - portnames:
1475         - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1476         - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1477 - TG [Server-Type-F4]:
1478     - testbedname: testbed34.
1479     - hostname: s64-t34-tg1.
1480     - IPMI IP: 10.30.50.74
1481     - Host IP: 10.30.51.74
1482     - portnames:
1483         - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1484         - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1485         - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1486         - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1487         - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1488         - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1489         - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1490         - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1491         - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1492         - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1493 ```
1494
1495 #### 3-Node-Denverton Servers (3n-dnv) PROD
1496
1497 ```
1498 - ServerB30 [Server-Type-B10]:
1499     - testbednames: testbed35.
1500     - hostname: s30-t35-sut1.
1501     - IPMI IP: 10.30.55.12
1502     - Host IP: 10.32.8.12
1503     - portnames:
1504         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1505         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1506         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1507         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1508 - ServerB31 [Server-Type-B10]:
1509     - testbednames: testbed35.
1510     - hostname: s31-t35-sut2.
1511     - IPMI IP: 10.30.55.13
1512     - Host IP: 10.32.8.13
1513     - portnames:
1514         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1515         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1516         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1517         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1518 ```
1519
1520 #### 3-Node-Icelake Servers (3n-icx) PROD
1521
1522 ```
1523 - ServerF1 [Server-Type-F1]:
1524     - testbedname: testbed37.
1525     - hostname: s65-t37-sut1.
1526     - IPMI IP: 10.30.50.75
1527     - Host IP: 10.30.51.75
1528     - portnames:
1529         - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1530         - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1531         - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1532         - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1533         - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1534         - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1535         - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1536         - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1537 - ServerF1 [Server-Type-F1]:
1538     - testbedname: testbed37.
1539     - hostname: s66-t37-sut2.
1540     - IPMI IP: 10.30.50.76
1541     - Host IP: 10.30.51.76
1542     - portnames:
1543         - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1544         - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1545         - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1546         - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1547         - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1548         - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1549         - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1550         - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1551 - ServerF3 [Server-Type-F3]:
1552     - testbedname: testbed37.
1553     - hostname: s67-t37-tg1.
1554     - IPMI IP: 10.30.50.77
1555     - Host IP: 10.30.51.77
1556     - portnames:
1557         - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1558         - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1559         - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1560         - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1561         - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1562         - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1563         - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1564         - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1565 - ServerF1 [Server-Type-F1]:
1566     - testbedname: testbed38.
1567     - hostname: s78-t38-sut1.
1568     - IPMI IP: 10.30.50.78
1569     - Host IP: 10.30.51.78
1570     - portnames:
1571         - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1572         - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1573         - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1574         - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1575         - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1576         - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1577         - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1578         - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1579 - ServerF1 [Server-Type-F1]:
1580     - testbedname: testbed38.
1581     - hostname: s79-t38-sut2.
1582     - IPMI IP: 10.30.50.79
1583     - Host IP: 10.30.51.79
1584     - portnames:
1585         - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1586         - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1587         - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1588         - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1589         - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1590         - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1591         - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1592         - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1593 - ServerF3 [Server-Type-F3]:
1594     - testbedname: testbed38.
1595     - hostname: s80-t38-tg1.
1596     - IPMI IP: 10.30.50.80
1597     - Host IP: 10.30.51.80
1598     - portnames:
1599         - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1600         - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1601         - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1602         - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1603         - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1604         - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1605         - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1606         - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1607 ```
1608
1609 #### 3-Node-SnowRidge Servers (3n-snr) PROD
1610
1611 ```
1612 - ServerG1 [Server-Type-G1]:
1613     - testbedname: testbed39.
1614     - hostname: s93-t39-sut1.
1615     - IPMI IP: 10.30.50.93
1616     - Host IP: 10.30.51.93
1617     - portnames:
1618         - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1619         - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1620         - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1621         - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1622 - ServerG1 [Server-Type-G1]:
1623     - testbedname: testbed39.
1624     - hostname: s94-t39-sut2.
1625     - IPMI IP: 10.30.50.94
1626     - Host IP: 10.30.51.94
1627     - portnames:
1628         - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1629         - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1630         - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1631         - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1632 - ServerF4 [Server-Type-F4]:
1633     - testbedname: testbed39.
1634     - hostname: s89-t39t310-tg1.
1635     - IPMI IP: 10.30.50.89
1636     - Host IP: 10.30.51.89
1637     - portnames:
1638         - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1639         - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1640         - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1641         - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1642 ```
1643
1644 ### Per Testbed Wiring
1645
1646 #### 1-Node-Skylake Wiring (1n-skx) PROD
1647
1648 ```
1649 - testbed11:
1650     - ring1 10GE-ports x710-4p10GE:
1651         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1652     - ring2 10GE-ports x710-4p10GE:
1653         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1654     - ring3 10GE-ports x710-4p10GE:
1655         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1656     - ring4 10GE-ports x710-4p10GE:
1657         - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1658     - ring5 100GE-ports e810-2p100GE:
1659         - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1660     - ring6 100GE-ports e810-2p100GE:
1661         - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1662 - testbed12:
1663     - ring1 10GE-ports x710-4p10GE:
1664         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1665     - ring2 10GE-ports x710-4p10GE:
1666         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1667     - ring3 10GE-ports x710-4p10GE:
1668         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1669     - ring4 10GE-ports x710-4p10GE:
1670         - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1671     - ring5 100GE-ports e810-2p100GE:
1672         - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1673     - ring6 100GE-ports e810-2p100GE:
1674         - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1675 ```
1676
1677 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1678
1679 ```
1680 - testbed13:
1681     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1682         - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1683     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1684         - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1685     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1686         - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1687     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1688         - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1689
1690 - testbed14:
1691     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1692         - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1693     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1694         - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1695     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1696         - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1697     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1698         - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1699 ```
1700
1701 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1702
1703 ```
1704 - testbed26:
1705     - ring1 10GE-ports x553 copper port on SUT:
1706         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1707         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1708     - ring2 10GE-ports x553 fiber port on SUT:
1709         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1710         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1711 ```
1712
1713 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1714
1715 ```
1716 - testbed25:
1717     - link1 10GE-port x710-4p10GE on SUT:
1718         - t25-tg1-p1 to t25-sut1-c2/p1.
1719     - link2 10GE-port x710-4p10GE on SUT:
1720         - t25-tg1-p2 to t25-sut1-c2/p2.
1721     - link3 10GE-port x710-4p10GE on SUT:
1722         - t25-tg1-p3 to t25-sut1-c2/p3.
1723     - link4 10GE-port x710-4p10GE on SUT:
1724         - t25-tg1-p4 to t25-sut1-c2/p4.
1725 ```
1726
1727 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1728
1729 ```
1730 - testbed27:
1731     - ring1 10GE-ports x710-4p10GE on SUT:
1732         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1733         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1734     - ring2 10GE-ports x710-4p10GE on SUT:
1735         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1736         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1737     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1738         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1739         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1740     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1741         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1742         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1743     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1744         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1745         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1746     - ring6 100GE-ports e810-2p100GE on TG:
1747         - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1748         - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1749 - testbed28:
1750     - ring1 10GE-ports x710-4p10GE on SUT:
1751         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1752         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1753     - ring2 10GE-ports x710-4p10GE on SUT:
1754         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1755         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1756     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1757         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1758         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1759     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1760         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1761         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1762     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1763         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1764         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1765     - ring6 100GE-ports e810-2p100GE on TG:
1766         - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1767         - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1768 - testbed29:
1769     - ring1 10GE-ports x710-4p10GE on SUT:
1770         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1771         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1772     - ring2 10GE-ports x710-4p10GE on SUT:
1773         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1774         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1775     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1776         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1777         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1778     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1779         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1780         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1781     - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1782         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1783         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1784 ```
1785
1786 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1787
1788 ```
1789 - testbed210:
1790     - ring1 10GE-ports x710-4p10GE on SUT:
1791         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1792         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1793     - ring2 10GE-ports x710-4p10GE on SUT:
1794         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1795         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1796     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1797         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1798         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1799     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1800         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1801         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1802 ```
1803
1804 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1805
1806 ```
1807 - testbed211:
1808     - ring1 10GE-ports x520-2p10GE on SUTs:
1809         - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1810         - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1811 ```
1812
1813 #### 2-Node-Icelake Wiring (2n-icx) PROD
1814
1815 ```
1816 - testbed212:
1817     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1818         - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
1819         - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
1820     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1821         - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
1822         - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
1823         - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
1824         - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
1825     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1826         - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
1827         - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
1828     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1829         - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
1830         - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
1831 - testbed213:
1832     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1833         - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
1834         - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
1835     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1836         - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
1837         - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
1838         - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
1839         - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
1840     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1841         - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
1842         - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
1843     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1844         - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
1845         - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
1846 - testbed214:
1847     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1848         - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
1849         - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
1850     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1851         - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
1852         - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
1853         - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
1854         - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
1855     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1856         - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
1857         - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
1858     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1859         - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
1860         - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
1861 - testbed215:
1862     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1863         - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
1864         - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
1865     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1866         - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
1867         - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
1868         - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
1869         - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
1870     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1871         - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
1872         - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
1873     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1874         - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
1875         - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
1876 ```
1877
1878 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
1879
1880 ```
1881 To be completed.
1882 ```
1883
1884 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1885
1886 ```
1887 - testbed33:
1888     - ring1 10GE-ports x520-2p10GE on SUTs:
1889         - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1890         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1891         - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1892     - ring2 25GE-ports cx4-2p25GE on SUTs:
1893         - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1894         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1895         - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1896 ```
1897
1898 #### 3-Node-Altra Wiring (3n-alt) PROD
1899
1900 ```
1901 - testbed34:
1902     - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1903         - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
1904         - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
1905         - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
1906 ```
1907
1908 #### 3-Node-Denverton Wiring (3n-dnv) PROD
1909
1910 ```
1911 - testbed35:
1912     - ring1 10GE-ports x553 copper port on SUTs:
1913         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1914         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1915         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1916     - ring2 10GE-ports x553 fiber port on SUTs:
1917         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1918         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1919         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1920 ```
1921
1922 #### 3-Node-Icelake Wiring (3n-icx) PROD
1923
1924 ```
1925 - testbed37:
1926     - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1927         - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
1928         - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
1929         - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
1930     - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1931         - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
1932         - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
1933         - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
1934         - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
1935         - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
1936         - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
1937     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1938         - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
1939         - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
1940         - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
1941 - testbed38:
1942     - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1943         - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
1944         - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
1945         - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
1946     - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1947         - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
1948         - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
1949         - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
1950         - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
1951         - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
1952         - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
1953     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1954         - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
1955         - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
1956         - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
1957 ```
1958
1959 #### 3-Node-SnowRidge Wiring (3n-snr) PROD
1960
1961 ```
1962 - testbed39:
1963     - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
1964         - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
1965         - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
1966         - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
1967         - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
1968         - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
1969         - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
1970 ```
1971
1972 ## Inventory
1973
1974 ### Appliances
1975
1976 ```
1977 1. Ixia PerfectStorm One Appliance
1978     - 1 * PS10GE4NG
1979         - Chassis: PS10GE4NG.
1980         - Motherboard: SuperMicro X11DPG-QT.
1981         - Processors: Quad-Core, Intel Processor.
1982         - HW accelerators: FPGA offload.
1983         - RAM Memory: 64GB.
1984         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1985         - Physical Interfaces: 4 * 10GE SFP+.
1986         - Operating System: Native IxOS.
1987 ```
1988
1989 ### Arm Servers
1990
1991 ```
1992 1. Arm Cortex A-72 servers
1993     - 2 * ThunderX2 (VPP Device)
1994         - Chassis: GIGABYTE Rack Mount
1995         - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1996         - RAM Memory: 16* 16GB DIMM
1997         - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1998     - 1 * ThunderX2 (Performance)
1999         - Chassis: GIGABYTE Rack Mount
2000         - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
2001         - RAM Memory: 4* 32GB RDIMM
2002         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
2003     - 2 * Huawei TaiShan 2280.
2004         - Chassis: Huawei TaiShan 2280.
2005         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
2006         - RAM Memory: 8* 16GB DDR4-2400MT/s.
2007         - Disks: 1* 4TB SATA HDD.
2008 2. Arm Neoverse N1 servers
2009     - 2 * Ampere Altra (Performance)
2010         - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
2011         - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
2012         - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
2013         - RAM Memory: 16* 8GB DDR4-3200MT/s
2014         - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
2015     - 2 * Ampere Altra (Build)
2016         - Chassis: Gigabyte R152-P30-00 1U
2017         - Motherboard: MP32-AR1-00
2018         - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
2019         - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
2020         - RAM Memory: 12* 16GB DDR4-3200MT/s
2021         - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
2022 ```
2023
2024 ### Xeon and Atom Servers
2025
2026 ```
2027 1. Intel Xeon servers:
2028     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
2029         - Chassis: SuperMicro SYS-7049GP-TRT.
2030         - Motherboard: SuperMicro X11DPG-QT.
2031         - Processors: 2* Intel Platinum 8180 2.5 GHz.
2032         - RAM Memory: 16* 16GB DDR4-2666MHz.
2033         - Disks: 2* 1.6TB 6G SATA SSD.
2034 2. Intel Atom servers with Rangely processors.
2035     - 3 * Netgate XG-2758-1u
2036         - Chassis: Netgate XG-2758-1u
2037         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
2038         - RAM Memory: 16GB ECC
2039         - Disks: 150 GB
2040 ```
2041
2042 ### Network Interface Cards
2043
2044 ```
2045 1. 10GE NICs
2046     - ?
2047 2. 25GE NICs
2048     - ?
2049 3. 40GE NICs
2050     - ?
2051 4. 100GE NICs
2052     - ?
2053 ```
2054
2055 ### Pluggables and Cables
2056
2057 Pluggables:
2058
2059 ```
2060 1. 10GE SFP+
2061     - ?
2062 2. 25GE SFP28
2063     - ?
2064 3. 40GE QSFP+
2065     - ?
2066 4. 100GE
2067     - ?
2068 ```
2069
2070 Standalone cables:
2071
2072 ```
2073 1. 10GE
2074     - ?
2075 2. 25GE
2076     - ?
2077 3. 40GE QSFP+
2078     - ?
2079 4. 100GE
2080     - ?
2081 ```
2082
2083 ### Other Parts