1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19 1. [Requirements](#requirements)
20 1. [Addressing](#addressing)
21 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24 1. [Server Types](#server-types)
25 1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30 1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38 1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39 1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40 1. [Per Testbed Wiring](#per-testbed-wiring)
41 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51 1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52 1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54 1. [Appliances](#appliances)
55 1. [Arm Servers](#arm-servers)
56 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57 1. [Network Interface Cards](#network-interface-cards)
58 1. [Pluggables and Cables](#pluggables-and-cables)
59 1. [Other Parts](#other-parts)
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
71 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0
73 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0
74 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0
75 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0
76 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
77 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
78 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
79 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0
80 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
81 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
82 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
83 12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
84 13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
85 14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0
86 Totals: 22 35 18 12 19 1 2 3 1 2 2
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
156 ### 3-Node-MACCHIATObin Arm Marvell
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
163 ### 3-Node-Rangeley Atom Testbeds
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
174 For management purposes, each server must have following two ports
175 connected to the management network:
179 - IPMI - Intelligent Platform Management Interface.
180 - Required for access to embedded server management with WebUI, CLI,
181 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183 - hostOS management port for general system management.
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
193 - Subnet: 10.30.50.0/24
194 - Gateway: 10.30.50.1
195 - Broadcast: 10.30.50.255
196 - DNS1: 199.204.44.24
197 - DNS2: 199.204.47.54
199 - Subnet: 10.30.51.0/24
200 - Gateway: 10.30.51.1
201 - Broadcast: 10.30.51.255
202 - DNS1: 199.204.44.24
203 - DNS2: 199.204.47.54
206 To access these hosts, VPN connection is required.
208 ### LOM (IPMI) VLAN IP Addresses
211 ------------ | -------
214 10.30.50.2 | LF Reserved
215 10.30.50.3 | LF Reserved
216 10.30.50.4 | LF Reserved
217 10.30.50.5 | LF Reserved
218 10.30.50.6 | LF Reserved
219 10.30.50.7 | LF Reserved
220 10.30.50.8 | LF Reserved
221 10.30.50.9 | LF Reserved
222 10.30.50.10 | LF Reserved
223 10.30.50.11 | LF Reserved
224 10.30.50.12 | LF Reserved
225 10.30.50.13 | LF Reserved
226 10.30.50.14 | LF Reserved
227 10.30.50.15 | LF Reserved
229 10.30.50.17 | t1-sut1
230 10.30.50.18 | t1-sut2
232 10.30.50.21 | t2-sut1
233 10.30.50.22 | t2-sut2
235 10.30.50.25 | t3-sut1
236 10.30.50.26 | t3-sut-2
237 10.30.50.28 | s41-nomad
238 10.30.50.29 | s39-nomad
239 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
240 10.30.50.30 | s40-nomad
241 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
242 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
243 10.30.50.32 | s42-nomad (formerly nomad1)
244 10.30.50.33 | s43-nomad (formerly nomad2)
245 10.30.50.36 | s17-t33-sut1
246 10.30.50.37 | s18-t33-sut2
247 10.30.50.41 | s3-t21-sut1
248 10.30.50.42 | s4-t21-tg1
249 10.30.50.43 | s11-t31-sut1
250 10.30.50.44 | s12-t31-sut2
251 10.30.50.45 | s13-t31-tg1
252 10.30.50.46 | s19-t33t34-tg1
253 10.30.50.47 | s1-t11-sut1
254 10.30.50.48 | s2-t12-sut1
255 10.30.50.49 | s5-t22-sut1
256 10.30.50.50 | s6-t22-tg1
257 10.30.50.51 | s7-t23-sut1
258 10.30.50.52 | s8-t23-tg1
259 10.30.50.53 | s9-t24-sut1
260 10.30.50.54 | s10-t24-tg1
261 10.30.50.55 | s14-t32-sut1
262 10.30.50.56 | s15-t32-sut2
263 10.30.50.57 | s16-t32-tg1
264 10.30.50.58 | s25-t25-sut1
265 10.30.50.59 | s26-t25-tg1
266 10.30.50.69 | s27-t13-sut
267 10.30.50.255 | Broadcast
272 10.30.55.10 | s28-t26t35-tg1
273 10.30.55.11 | s29-t26-sut1
274 10.30.55.12 | s30-t35-sut1
275 10.30.55.13 | s31-t35-sut2
276 10.30.55.14 | s46-nomad (formerly server-type-c4-1)
277 10.30.55.15 | s47-nomad (formerly server-type-c4-2)
278 10.30.55.17 | s32-t14-sut1
279 10.30.55.18 | s33-t27-sut1
280 10.30.55.19 | s34-t27-tg1
281 10.30.55.20 | s35-t28-sut1
282 10.30.55.21 | s36-t28-tg1
283 10.30.55.22 | s37-t29-sut1
284 10.30.55.23 | s38-t29-tg1
285 10.30.55.255 | Broadcast
287 ### Management VLAN IP Addresses
290 ------------------------- | -------
293 10.30.51.2 | LF Reserved
294 10.30.51.3 | LF Reserved
295 10.30.51.4 | LF Reserved
296 10.30.51.5 | LF Reserved
297 10.30.51.6 | LF Reserved
298 10.30.51.7 | LF Reserved
299 10.30.51.8 | LF Reserved
300 10.30.51.9 | s22-t35-sut1 (netgate-1)
301 10.30.51.10 | s23-t35-sut2 (netgate-2)
302 10.30.51.11 | s24-t35-sut3 (netgate-3)
303 10.30.51.12 | softiron-1
304 10.30.51.13 | s44-nomad (formerly nomad1arm)
305 10.30.51.14 | s45-nomad (formerly nomad2arm)
306 10.30.51.15 | LF Reserved
308 10.30.51.17 | t1-sut1
309 10.30.51.18 | t1-sut2
311 10.30.51.21 | t2-sut1
312 10.30.51.22 | t2-sut2
314 10.30.51.25 | t3-sut1
315 10.30.51.26 | t3-sut-2
316 10.30.51.28 | s41-nomad
317 10.30.51.29 | s39-nomad
318 10.30.51.30 | s40-nomad
319 10.30.51.32 | s42-nomad (formerly nomad1)
320 10.30.51.33 | s43-nomad (formerly nomad2)
321 10.30.51.36 | s17-t33-sut1
322 10.30.51.37 | s18-t33-sut2
323 10.30.51.41 | s20-t34-sut1
324 10.30.51.42 | s21-t34-sut2
325 10.30.51.44 | s3-t21-sut1
326 10.30.51.45 | s4-t21-tg1
327 10.30.51.46 | s11-t31-sut1
328 10.30.51.47 | s12-t31-sut2
329 10.30.51.48 | s13-t31-tg1
330 10.30.51.49 | s19-t33t34-tg1
331 10.30.51.50 | s1-t11-sut1
332 10.30.51.51 | s2-t12-sut1
333 10.30.51.52 | s5-t22-sut1
334 10.30.51.53 | s6-t22-tg1
335 10.30.51.54 | s7-t23-sut1
336 10.30.51.55 | s8-t23-tg1
337 10.30.51.56 | s9-t24-sut1
338 10.30.51.57 | s10-t24-tg1
339 10.30.51.58 | s14-t32-sut1
340 10.30.51.59 | s15-t32-sut2
341 10.30.51.60 | s16-t32-tg1
342 10.30.51.61 | s25-t25-sut1
343 10.30.51.62 | s26-t25-tg1
344 10.30.51.69 | s27-t13-sut1
345 10.30.51.70-10.30.51.105 | FREE
346 10.30.51.106-10.30.51.180 | FREE
347 10.30.51.181-10.30.51.254 | FREE
348 10.30.51.255 | Broadcast
351 10.32.8.10 | s28-t26t35-tg1
352 10.32.8.11 | s29-t26-sut1
353 10.32.8.12 | s30-t35-sut1
354 10.32.8.13 | s31-t35-sut2
355 10.32.8.14 | s46-nomad (formerly server-type-c4-1)
356 10.32.8.15 | s47-nomad (formerly server-type-c4-2)
357 10.32.8.17 | s32-t14-sut1
358 10.32.8.18 | s33-t27-sut1
359 10.32.8.19 | s34-t27-tg1
360 10.32.8.20 | s35-t28-sut1
361 10.32.8.21 | s36-t28-tg1
362 10.32.8.22 | s37-t29-sut1
363 10.32.8.23 | s38-t29-tg1
364 10.32.8.255 | Broadcast
366 ## Server Specifications
370 FD.io CSIT lab contains following server types:
372 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
373 - Quantity: 6 servers.
374 - Physical connectivity:
375 - CIMC and host management ports.
376 - NIC ports connected in 3-node topologies.
377 - Main HW configuration:
378 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
379 - Processors: 2* E5-2699v3 2.3 GHz.
380 - RAM Memory: 16* 32GB DDR4-2133MHz.
381 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
382 - NICs configuration:
383 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
384 - PCIe Slot1: Cisco VIC 1385 2p40GE.
385 - PCIe Slot2: Intel NIC x520 2p10GE.
387 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
388 - PCIe Slot4: Intel NIC xl710 2p40GE.
389 - PCIe Slot5: Intel NIC x710 2p10GE.
390 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
391 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
392 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
393 - Quantity: 3 servers.
394 - Physical connectivity:
395 - CIMC and host management ports.
396 - NIC ports connected in 3-node topologies.
397 - Main HW configuration:
398 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
399 - Processors: 2* E5-2699v3 2.3 GHz.
400 - RAM Memory: 16* 32GB DDR4-2133MHz.
401 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
402 - NICs configuration:
403 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
404 - PCIe Slot1: Intel NIC xl710 2p40GE.
405 - PCIe Slot2: Intel NIC x710 2p10GE.
406 - PCIe Slot3: Intel NIC x710 2p10GE.
407 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
408 - PCIe Slot4: Intel NIC xl710 2p40GE.
409 - PCIe Slot5: Intel NIC x710 2p10GE.
410 - PCIe Slot6: Intel NIC x710 2p10GE.
412 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
413 - Quantity: 3 servers.
414 - Physical connectivity:
415 - CIMC and host management ports.
416 - no NIC ports, standalone setup.
417 - Main HW configuration:
418 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
419 - Processors: 2* E5-2699v3 2.3 GHz.
420 - RAM Memory: 16* 32GB DDR4-2133MHz.
421 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
422 - NICs configuration:
423 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
425 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
428 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
430 - Physical connectivity:
431 - IPMI and host management ports.
432 - NIC ports connected into 2-node and 3-node topologies.
433 - Main HW configuration:
434 - Chassis: SuperMicro SYS-7049GP-TRT.
435 - Motherboard: SuperMicro X11DPG-QT.
436 - Processors: 2* Intel Platinum 8180 2.5 GHz.
437 - RAM Memory: 16* 16GB DDR4-2666MHz.
438 - Disks: 2* 1.6TB 6G SATA SSD.
439 - NICs configuration:
440 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
441 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
442 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
443 - PCIe Slot9 5e:00.xx: empty.
444 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
445 - PCIe Slot6 86:00.xx: empty.
446 - PCIe Slot8 af:00.xx: empty.
447 - PCIe Slot10 d8:00.xx: empty.
448 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
450 - Physical connectivity:
451 - IPMI and host management ports.
452 - NIC ports connected into 2-node and 3-node topologies.
453 - Main HW configuration:
454 - Chassis: SuperMicro SYS-7049GP-TRT.
455 - Motherboard: SuperMicro X11DPG-QT.
456 - Processors: 2* Intel Platinum 8180 2.5 GHz.
457 - RAM Memory: 16* 16GB DDR4-2666MHz.
458 - Disks: 2* 1.6TB 6G SATA SSD.
459 - NICs configuration:
460 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
461 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
462 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
463 - PCIe Slot9 5e:00.xx: empty.
464 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
465 - PCIe Slot6 86:00.xx: empty.
466 - PCIe Slot8 af:00.xx: empty.
467 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
468 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
470 - Physical connectivity:
471 - IPMI(?) and host management ports.
472 - NIC ports connected into 3-node topology.
473 - Main HW configuration:
474 - Chassis: Huawei TaiShan 2280.
475 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
476 - RAM Memory: 8* 16GB DDR4-2400MT/s
477 - Disks: 1* 4TB SATA HDD
478 - NICs configuration:
479 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
480 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
481 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
483 - Physical connectivity:
484 - Host management ports.
485 - NIC ports connected into 2-node and 3-node topologies.
486 - Main HW configuration:
487 - Chassis: MACCHIATObin.
488 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
489 - RAM Memory: 1* 16GB DDR4
490 - Disks: 1* 128GB(?) SATA SDD
491 - NICs configuration:
492 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
493 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
494 - Quantity: TBD based on testbed allocation.
495 - Physical connectivity:
496 - Management: serial Port (usb) for console
497 - NIC ports connected into 2-node.
498 - Main HW configuration:
499 - Chassis: Netgate XG-2758-1u
500 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
501 - RAM Memory: 16GB ECC
503 - NICs configuration:
504 - 2x 10Gb Intel 82599ES
506 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
508 - Physical connectivity:
509 - IPMI and host management ports.
510 - NIC ports connected into 2-node and 3-node topologies.
511 - Main HW configuration:
512 - Chassis: SuperMicro SYS-7049GP-TRT.
513 - Motherboard: SuperMicro X11DPG-QT.
514 - Processors: 2* Intel Platinum 8180 2.5 GHz.
515 - RAM Memory: 16* 16GB DDR4-2666MHz.
516 - Disks: 2* 1.6TB 6G SATA SSD.
517 - NICs configuration:
518 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
519 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
520 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
521 - PCIe Slot9 5e:00.xx: empty.
522 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
523 - PCIe Slot6 86:00.xx: empty.
524 - PCIe Slot8 af:00.xx: empty.
525 - PCIe Slot10 d8:00.xx: empty.
526 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
528 - Physical connectivity:
529 - Host management interface: 10/100/1000-BaseT.
530 - 8-port 10GE SFP+ integrated NIC.
531 - Main HW configuration:
532 - Chassis: PS10GE4NG.
533 - Motherboard: SuperMicro X11DPG-QT.
534 - Processors: Quad-Core, Intel Processor.
535 - HW accelerators: FPGA offload.
537 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
538 - Physical Interfaces: 4 * 10GE SFP+.
539 - Operating System: Native IxOS.
540 - Interface configuration:
545 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
547 - Physical connectivity:
548 - IPMI and host management ports.
550 - Main HW configuration:
551 - Chassis: SuperMicro SYS-7049GP-TRT.
552 - Motherboard: SuperMicro X11DPG-QT.
553 - Processors: 2* Intel Platinum 8180 2.5 GHz.
554 - RAM Memory: 16* 16GB DDR4-2666MHz.
555 - Disks: 2* 1.6TB 6G SATA SSD.
556 - NICs configuration:
557 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
558 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
559 - PCIe Slot4 3b:00.xx: empty.
560 - PCIe Slot9 5e:00.xx: empty.
561 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
562 - PCIe Slot6 86:00.xx: empty.
563 - PCIe Slot8 af:00.xx: empty.
564 - PCIe Slot10 d8:00.xx: empty.
565 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
567 - Physical connectivity:
568 - IPMI and host management ports.
569 - NIC ports connected into 1-node topologies.
570 - Main HW configuration:
571 - Chassis: Gigabyte R181-T90 1U
572 - Motheboard: MT91-FS1
573 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
574 - RAM Memory: 4* 32GB RDIMM
575 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
576 - NICs configuration:
578 - PCIe Slot1 05:00.xx: XL710-QDA2.
579 - PCIe Slot3 08:00.xx: XL710-QDA2.
581 - PCIe Slot6 85:00.xx: XL710-QDA2.
582 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
584 - Physical connectivity:
585 - IPMI and host management ports.
587 - Main HW configuration:
588 - Chassis: SuperMicro SYS-E300-9A
589 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
590 - RAM Memory: 32GB ECC
592 - NICs configuration:
593 - 2x 10Gb Intel x553 fiber ports
594 - 2x 10Gb Intel x553 copper ports
595 - 4x 1GB Intel I350 ports
597 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
599 - Physical connectivity:
600 - IPMI and host management ports.
601 - NIC ports connected into 1-node testbed topologies.
602 - Main HW configuration:
603 - Chassis: SuperMicro SYS-7049GP-TRT.
604 - Motherboard: SuperMicro X11DPG-QT.
605 - Processors: 2* Intel Platinum 8280 2.7 GHz.
606 - RAM Memory: 12* 16GB DDR4-2933.
607 - Disks: 2* 1.92TB SATA SSD.
608 - NICs configuration:
609 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
610 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
611 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
612 - PCIe Slot9 5e:00.xx: empty.
613 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
614 - PCIe Slot6 86:00.xx: empty.
615 - PCIe Slot8 af:00.xx: empty.
616 - PCIe Slot10 d8:00.xx: empty.
618 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
620 - Physical connectivity:
621 - IPMI and host management ports.
622 - NIC ports connected into 2-node testbed topologies.
623 - Main HW configuration:
624 - Chassis: SuperMicro SYS-7049GP-TRT.
625 - Motherboard: SuperMicro X11DPG-QT.
626 - Processors: 2* Intel Gold 6252N 2.3 GHz.
627 - RAM Memory: 12* 16GB DDR4-2933.
628 - Disks: 2* 1.92TB SATA SSD.
629 - NICs configuration:
630 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
631 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
632 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
633 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
634 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
635 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
636 - PCIe Slot6 86:00.xx: empty.
637 - PCIe Slot8 af:00.xx: empty.
638 - PCIe Slot10 d8:00.xx: empty.
639 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
641 - Physical connectivity:
642 - IPMI and host management ports.
643 - NIC ports connected into 2-node testbed topologies.
644 - Main HW configuration:
645 - Chassis: SuperMicro SYS-7049GP-TRT.
646 - Motherboard: SuperMicro X11DPG-QT.
647 - Processors: 2* Intel Platinum 8280 2.7 GHz.
648 - RAM Memory: 12* 16GB DDR4-2933.
649 - Disks: 2* 1.92TB SATA SSD.
650 - NICs configuration:
651 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
652 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
653 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
654 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
655 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
656 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
657 - PCIe Slot6 86:00.xx: empty.
658 - PCIe Slot8 af:00.xx: empty.
659 - PCIe Slot10 d8:00.xx: empty.
661 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
663 - Physical connectivity:
664 - CIMC and host management ports.
665 - no NIC ports, standalone setup.
666 - Main HW configuration:
667 - Chassis: SuperMicro 1029P-WTRT.
668 - Motherboard: SuperMicro X11DDW-NT.
669 - Processors: 2* Intel Platinum 8280 2.7 GHz.
670 - RAM Memory: 12* 16GB DDR4-2933.
671 - Disks: 4* 1.92TB SATA SSD.
672 - NICs configuration:
679 ### Naming Convention
681 Following naming convention is used within this page to specify physical
682 connectivity and wiring across defined CSIT testbeds:
685 - testbedname: testbedN.
687 - traffic-generator: tN-tgW.
688 - system-under-testX: tN-sutX.
693 - N - testbed number.
694 - tgW - server acts as traffic-generator with W index.
695 - sutX - server acts as system-under-test with X index.
696 - Y - PCIe slot number denoting a NIC card number within the host.
697 - Z - port number on the NIC card.
700 ## Testbeds Configuration
702 ### Per Testbed Server Allocation and Naming
704 #### 1-Node-Skylake Servers (1n-skx) PROD
707 - SUT [Server-Type-B6]:
708 - testbedname: testbed11.
709 - hostname: s1-t11-sut1.
710 - IPMI IP: 10.30.50.47
711 - Host IP: 10.30.51.50
713 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
714 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
715 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
716 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
717 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
718 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
719 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
720 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
721 - SUT [Server-Type-B6]:
722 - testbedname: testbed12.
723 - hostname: s2-t12-sut1.
724 - IPMI IP: 10.30.50.48
725 - Host IP: 10.30.51.51
727 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
728 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
729 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
730 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
731 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
732 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
733 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
734 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
737 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
740 - SUT [Server-Type-B9]:
741 - testbedname: testbed13.
742 - hostname: s27-t13-sut1.
743 - IPMI IP: 10.30.50.69
744 - Host IP: 10.30.51.69
746 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
747 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
748 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
749 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
750 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
751 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
754 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
757 - SUT [Server-Type-C1]:
758 - testbedname: testbed11.
759 - hostname: s32-t14-sut1.
760 - IPMI IP: 10.30.55.17
761 - Host IP: 10.32.8.17
763 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
764 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
765 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
766 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
767 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
768 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
769 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
770 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
773 #### 2-Node-Skylake Servers (2n-skx) PROD
776 - SUT [Server-Type-B1]:
777 - testbedname: testbed21.
778 - hostname: s3-t21-sut1.
779 - IPMI IP: 10.30.50.41
780 - Host IP: 10.30.51.44
782 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
783 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
784 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
785 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
786 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
787 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
788 - TG [Server-Type-B2]:
789 - testbedname: testbed21.
790 - hostname: s4-t21-tg1.
791 - IPMI IP: 10.30.50.42
792 - Host IP: 10.30.51.45
794 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
795 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
796 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
797 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
798 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
799 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
800 - SUT [Server-Type-B1]:
801 - testbedname: testbed22.
802 - hostname: s5-t22-sut1.
803 - IPMI IP: 10.30.50.49
804 - Host IP: 10.30.51.52
806 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
807 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
808 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
809 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
810 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
811 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
812 - TG [Server-Type-B2]:
813 - testbedname: testbed22.
814 - hostname: s6-t22-tg1.
815 - IPMI IP: 10.30.50.50
816 - Host IP: 10.30.51.53
818 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
819 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
820 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
821 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
822 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
823 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
824 - SUT [Server-Type-B1]:
825 - testbedname: testbed23.
826 - hostname: s7-t23-sut1.
827 - IPMI IP: 10.30.50.51
828 - Host IP: 10.30.51.54
830 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
831 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
832 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
833 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
834 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
835 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
836 - TG [Server-Type-B2]:
837 - testbedname: testbed23.
838 - hostname: s8-t23-tg1.
839 - IPMI IP: 10.30.50.52
840 - Host IP: 10.30.51.55
842 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
843 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
844 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
845 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
846 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
847 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
848 - SUT [Server-Type-B1]:
849 - testbedname: testbed24.
850 - hostname: s9-t24-sut1.
851 - IPMI IP: 10.30.50.53
852 - Host IP: 10.30.51.56
854 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
855 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
856 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
857 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
858 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
859 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
860 - TG [Server-Type-B2]:
861 - testbedname: testbed24.
862 - hostname: s10-t24-tg1.
863 - IPMI IP: 10.30.50.54
864 - Host IP: 10.30.51.57
866 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
867 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
868 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
869 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
870 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
871 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
874 #### 2-Node-Denverton Servers (2n-dnv) WIP
876 Note: ServerB28 (TG) is shared between testbed26 & testbed35
879 - TG [Server-Type-B2]:
880 - testbednames: testbed26 and testbed35.
881 - hostname: s28-t26t35-tg1.
882 - IPMI IP: 10.30.55.10
883 - Host IP: 10.32.8.10
885 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
886 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
887 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
888 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
889 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
890 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
891 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
892 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
893 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
894 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
895 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
896 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
897 - SUT [Server-Type-B10]:
898 - testbednames: testbed26.
899 - hostname: s29-t26-sut1.
900 - IPMI IP: 10.30.55.11
901 - Host IP: 10.32.8.11
903 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
904 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
905 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
906 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
909 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
912 - SUT [Server-Type-B8]:
913 - testbedname: testbed25.
914 - hostname: s25-t25-sut1.
915 - IPMI IP: 10.30.50.58
916 - Host IP: 10.30.51.61
918 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
919 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
920 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
921 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
922 - TG [Server-Type-B7]:
923 - testbedname: testbed25.
924 - hostname: s26-t25-tg1.
925 - IPMI IP: 10.30.50.59
926 - Host IP: 10.30.51.62
928 - s26-t25-tg1-p1 - 10GE-port1.
929 - s26-t25-tg1-p2 - 10GE-port2.
930 - s26-t25-tg1-p3 - 10GE-port3.
931 - s26-t25-tg1-p4 - 10GE-port4.
934 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
937 - SUT [Server-Type-C2]:
938 - testbedname: testbed27.
939 - hostname: s33-t27-sut1.
940 - IPMI IP: 10.30.55.18
941 - Host IP: 10.32.8.18
943 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
944 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
945 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
946 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
947 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
948 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
949 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
950 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
951 - TG [Server-Type-C3]:
952 - testbedname: testbed27.
953 - hostname: s34-t27-tg1.
954 - IPMI IP: 10.30.55.19
955 - Host IP: 10.32.8.19
957 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
958 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
959 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
960 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
961 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
962 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
963 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
964 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
965 - SUT [Server-Type-C2]:
966 - testbedname: testbed28.
967 - hostname: s35-t28-sut1.
968 - IPMI IP: 10.30.55.20
969 - Host IP: 10.32.8.20
971 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
972 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
973 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
974 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
975 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
976 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
977 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
978 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
979 - TG [Server-Type-C3]:
980 - testbedname: testbed28.
981 - hostname: s36-t28-tg1.
982 - IPMI IP: 10.30.55.21
983 - Host IP: 10.32.8.21
985 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
986 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
987 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
988 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
989 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
990 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
991 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
992 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
993 - SUT [Server-Type-C2]:
994 - testbedname: testbed29.
995 - hostname: s37-t29-sut1.
996 - IPMI IP: 10.30.55.22
997 - Host IP: 10.32.8.22
999 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1000 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1001 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1002 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1003 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1004 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1005 - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1006 - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1007 - TG [Server-Type-C3]:
1008 - testbedname: testbed29.
1009 - hostname: s38-t29-tg1.
1010 - IPMI IP: 10.30.55.23
1011 - Host IP: 10.32.8.23
1013 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1014 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1015 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1016 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1017 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1018 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1019 - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1020 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1023 #### 3-Node-Haswell Servers (3n-hsw) PROD
1026 1. SUT [Server-Type-A1]:
1027 - testbedname: testbed1.
1028 - hostname: t1-sut1.
1029 - CIMC IP: 10.30.50.17
1030 - Host IP: 10.30.51.17
1032 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1033 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1034 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1035 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1036 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1037 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1038 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1039 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1040 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1041 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1042 2. SUT [Server-Type-A1]:
1043 - testbedname: testbed1.
1044 - hostname: t1-sut2.
1045 - CIMC IP: 10.30.50.18
1046 - Host IP: 10.30.51.18
1048 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1049 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1050 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1051 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1052 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1053 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1054 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1055 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1056 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1057 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1058 3. TG [Server-Type-A2]:
1059 - testbedname: testbed1.
1061 - CIMC IP: 10.30.50.16
1062 - Host IP: 10.30.51.16
1064 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1065 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1066 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1067 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1068 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1069 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1070 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1071 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1072 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1073 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1074 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1075 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1076 4. SUT [Server-Type-A1]:
1077 - testbedname: testbed2.
1078 - hostname: t2-sut1.
1079 - CIMC IP: 10.30.50.21
1080 - Host IP: 10.30.51.21
1082 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1083 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1084 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1085 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1086 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1087 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1088 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1089 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1090 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1091 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1092 5. SUT [Server-Type-A1]:
1093 - testbedname: testbed2.
1094 - hostname: t2-sut2.
1095 - CIMC IP: 10.30.50.22
1096 - Host IP: 10.30.51.22
1098 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1099 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1100 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1101 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1102 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1103 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1104 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1105 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1106 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1107 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1108 6. TG [Server-Type-A2]:
1109 - testbedname: testbed2.
1111 - CIMC IP: 10.30.50.20
1112 - Host IP: 10.30.51.20
1114 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1115 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1116 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1117 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1118 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1119 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1120 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1121 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1122 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1123 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1124 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1125 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1126 7. SUT [Server-Type-A1]:
1127 - testbedname: testbed3.
1128 - hostname: t3-sut1.
1129 - CIMC IP: 10.30.50.25
1130 - Host IP: 10.30.51.25
1132 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1133 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1134 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1135 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1136 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1137 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1138 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1139 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1140 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1141 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1142 8. SUT [Server-Type-A1]:
1143 - testbedname: testbed3.
1144 - hostname: t3-sut2.
1145 - CIMC IP: 10.30.50.26
1146 - Host IP: 10.30.51.26
1148 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1149 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1150 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1151 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1152 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1153 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1154 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1155 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1156 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1157 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1158 9. TG [Server-Type-A2]:
1159 - testbedname: testbed3.
1161 - CIMC IP: 10.30.50.24
1162 - Host IP: 10.30.51.24
1164 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1165 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1166 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1167 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1168 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1169 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1170 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1171 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1172 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1173 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1174 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1175 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1178 #### 3-Node-Skylake Servers (3n-skx) PROD
1181 - ServerB11 [Server-Type-B1]:
1182 - testbedname: testbed31.
1183 - hostname: s11-t31-sut1.
1184 - IPMI IP: 10.30.50.43
1185 - Host IP: 10.30.51.46
1187 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1188 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1189 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1190 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1191 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1192 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1193 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1194 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1195 - ServerB12 [Server-Type-B1]:
1196 - testbedname: testbed31.
1197 - hostname: s12-t31-sut2.
1198 - IPMI IP: 10.30.50.44
1199 - Host IP: 10.30.51.47
1201 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1202 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1203 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1204 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1205 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1206 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1207 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1208 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1209 - ServerB13 [Server-Type-B2]:
1210 - testbedname: testbed31.
1211 - hostname: s13-t31-tg1.
1212 - IPMI IP: 10.30.50.45
1213 - Host IP: 10.30.51.48
1215 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1216 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1217 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1218 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1219 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1220 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1221 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1222 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1223 - ServerB14 [Server-Type-B1]:
1224 - testbedname: testbed32.
1225 - hostname: s14-t32-sut1.
1226 - IPMI IP: 10.30.50.55
1227 - Host IP: 10.30.51.58
1229 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1230 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1231 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1232 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1233 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1234 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1235 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1236 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1237 - ServerB15 [Server-Type-B1]:
1238 - testbedname: testbed32.
1239 - hostname: s15-t32-sut2.
1240 - IPMI IP: 10.30.50.56
1241 - Host IP: 10.30.51.59
1243 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1244 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1245 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1246 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1247 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1248 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1249 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1250 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1251 - ServerB16 [Server-Type-B2]:
1252 - testbedname: testbed32.
1253 - hostname: s16-t32-tg1.
1254 - IPMI IP: 10.30.50.57
1255 - Host IP: 10.30.51.60
1257 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1258 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1259 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1260 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1261 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1262 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1263 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1264 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1267 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1269 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1272 - ServerB22 [Server-Type-B5]:
1273 - testbedname: testbed35.
1274 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1275 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1276 - Host IP: 10.30.51.9
1278 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1279 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1281 - ServerB23 [Server-Type-B5]:
1282 - testbedname: testbed35.
1283 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1284 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1285 - Host IP: 10.30.51.10
1287 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1288 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1290 - ServerB24 [Server-Type-B5]:
1291 - testbedname: testbed35.
1292 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1293 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1294 - Host IP: 10.30.51.11
1296 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1297 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1301 #### 3-Node-Taishan Servers (3n-tsh) WIP
1303 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1306 - ServerB17 [Server-Type-B3]:
1307 - testbedname: testbed33.
1308 - hostname: s17-t33-sut1.
1309 - IPMI IP: 10.30.50.36
1310 - Host IP: 10.30.51.36
1312 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1313 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1314 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1315 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1316 - ServerB18 [Server-Type-B3]:
1317 - testbedname: testbed33.
1318 - hostname: s18-t33-sut2.
1319 - IPMI IP: 10.30.50.37
1320 - Host IP: 10.30.51.37
1322 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1323 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1324 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1325 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1326 - ServerB19 [Server-Type-B2]:
1327 - testbednames: testbed33 and testbed34.
1328 - hostname: s19-t33t34-tg1.
1329 - IPMI IP: 10.30.50.46
1330 - Host IP: 10.30.51.49
1332 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1333 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1334 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1335 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1336 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1337 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1338 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1339 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1340 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1341 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1342 - ServerB20 [Server-Type-B4]:
1343 - testbedname: testbed34.
1344 - hostname: s20-t34-sut1.
1346 - Host IP: 10.30.51.41
1348 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1349 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1350 - ServerB21 [Server-Type-B4]:
1351 - testbedname: testbed34.
1352 - hostname: s21-t34-sut2.
1354 - Host IP: 10.30.51.42
1356 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1357 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1360 #### 3-Node-Denverton Servers (3n-dnv) WIP
1363 - ServerB30 [Server-Type-B10]:
1364 - testbednames: testbed35.
1365 - hostname: s30-t35-sut1.
1366 - IPMI IP: 10.30.55.12
1367 - Host IP: 10.32.8.12
1369 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1370 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1371 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1372 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1373 - ServerB31 [Server-Type-B10]:
1374 - testbednames: testbed35.
1375 - hostname: s31-t35-sut2.
1376 - IPMI IP: 10.30.55.13
1377 - Host IP: 10.32.8.13
1379 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1380 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1381 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1382 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1385 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1391 ### Per Testbed Wiring
1393 #### 1-Node-Skylake Wiring (1n-skx) PROD
1397 - ring1 10GE-ports x710-4p10GE:
1398 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1399 - ring2 10GE-ports x710-4p10GE:
1400 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1401 - ring3 10GE-ports x710-4p10GE:
1402 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1403 - ring4 10GE-ports x710-4p10GE:
1404 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1406 - ring1 10GE-ports x710-4p10GE:
1407 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1408 - ring2 10GE-ports x710-4p10GE:
1409 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1410 - ring3 10GE-ports x710-4p10GE:
1411 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1412 - ring4 10GE-ports x710-4p10GE:
1413 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1416 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1420 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1421 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1422 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1423 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1424 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1425 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1428 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1432 - ring1 10GE-ports x710-4p10GE:
1433 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1434 - ring2 10GE-ports x710-4p10GE:
1435 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1436 - ring3 10GE-ports x710-4p10GE:
1437 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1438 - ring4 10GE-ports x710-4p10GE:
1439 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1442 #### 2-Node-Skylake Wiring (2n-skx) PROD
1446 - ring1 10GE-ports x710-4p10GE on SUT:
1447 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1448 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1449 - ring2 10GE-ports x710-4p10GE on SUT:
1450 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1451 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1452 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1453 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1454 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1456 - ring1 10GE-ports x710-4p10GE on SUT:
1457 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1458 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1459 - ring2 10GE-ports x710-4p10GE on SUT:
1460 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1461 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1462 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1463 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1464 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1466 - ring1 10GE-ports x710-4p10GE on SUT:
1467 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1468 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1469 - ring2 10GE-ports x710-4p10GE on SUT:
1470 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1471 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1472 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1473 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1474 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1476 - ring1 10GE-ports x710-4p10GE on SUT:
1477 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1478 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1479 - ring2 10GE-ports x710-4p10GE on SUT:
1480 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1481 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1482 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1483 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1484 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1487 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1491 - ring1 10GE-ports x553 copper port on SUT:
1492 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1493 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1494 - ring2 10GE-ports x553 fiber port on SUT:
1495 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1496 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1499 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1503 - link1 10GE-port x710-4p10GE on SUT:
1504 - t25-tg1-p1 to t25-sut1-c2/p1.
1505 - link2 10GE-port x710-4p10GE on SUT:
1506 - t25-tg1-p2 to t25-sut1-c2/p2.
1507 - link3 10GE-port x710-4p10GE on SUT:
1508 - t25-tg1-p3 to t25-sut1-c2/p3.
1509 - link4 10GE-port x710-4p10GE on SUT:
1510 - t25-tg1-p4 to t25-sut1-c2/p4.
1513 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1517 - ring1 10GE-ports x710-4p10GE on SUT:
1518 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1519 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1520 - ring2 10GE-ports x710-4p10GE on SUT:
1521 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1522 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1523 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1524 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1525 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1526 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1527 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1528 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1530 - ring1 10GE-ports x710-4p10GE on SUT:
1531 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1532 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1533 - ring2 10GE-ports x710-4p10GE on SUT:
1534 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1535 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1536 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1537 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1538 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1539 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1540 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1541 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1543 - ring1 10GE-ports x710-4p10GE on SUT:
1544 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1545 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1546 - ring2 10GE-ports x710-4p10GE on SUT:
1547 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1548 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1549 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1550 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1551 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1552 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1553 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1554 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1557 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1561 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1562 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1563 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1564 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1565 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1566 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1567 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1568 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1569 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1570 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1571 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1572 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1573 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1574 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1575 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1576 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1577 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1578 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1579 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1580 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1581 - TG loopback ports Intel NIC x710 2p10GE
1582 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1585 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1586 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1587 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1588 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1589 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1590 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1591 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1592 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1593 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1594 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1595 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1596 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1597 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1598 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1599 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1600 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1601 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1602 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1603 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1604 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1605 - TG loopback ports Intel NIC x710 2p10GE
1606 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1609 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1610 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1611 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1612 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1613 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1614 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1615 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1616 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1617 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1618 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1619 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1620 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1621 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1622 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1623 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1624 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1625 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1626 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1627 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1628 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1629 - TG loopback ports Intel NIC x710 2p10GE
1630 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1633 #### 3-Node-Skylake Wiring (3n-skx) PROD
1637 - ring1 10GE-ports x710-4p10GE on SUTs:
1638 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1639 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1640 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1641 - ring2 10GE-ports x710-4p10GE on SUT:
1642 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1643 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1644 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1645 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1646 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1647 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1648 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1649 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1650 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1651 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1652 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1653 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1654 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1655 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1657 - ring1 10GE-ports x710-4p10GE on SUTs:
1658 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1659 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1660 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1661 - ring2 10GE-ports x710-4p10GE on SUT:
1662 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1663 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1664 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1665 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1666 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1667 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1668 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1669 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1670 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1671 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1672 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1673 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1674 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1675 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1678 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1684 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1688 - ring1 10GE-ports x520-2p10GE on SUTs:
1689 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1690 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1691 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1692 - ring2 25GE-ports cx4-2p25GE on SUTs:
1693 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1694 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1695 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1698 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1702 - ring1 10GE-ports Marvell on SUTs:
1703 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1704 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1705 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1708 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1712 - ring1 10GE-ports x553 copper port on SUTs:
1713 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1714 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1715 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1716 - ring2 10GE-ports x553 fiber port on SUTs:
1717 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1718 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1719 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1727 1. Ixia PerfectStorm One Appliance
1729 - Chassis: PS10GE4NG.
1730 - Motherboard: SuperMicro X11DPG-QT.
1731 - Processors: Quad-Core, Intel Processor.
1732 - HW accelerators: FPGA offload.
1734 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1735 - Physical Interfaces: 4 * 10GE SFP+.
1736 - Operating System: Native IxOS.
1742 1. Arm Cortex A-72 servers
1744 - Chassis: Marvell ThunderX2
1745 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1746 - RAM Memory: 4* 32GB RDIMM
1747 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1748 - 2 * Huawei TaiShan 2280.
1749 - Chassis: Huawei TaiShan 2280.
1750 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1751 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1752 - Disks: 1* 4TB SATA HDD.
1754 - Chassis: MACCHIATObin.
1755 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1756 - RAM Memory: 1* 16GB DDR4.
1757 - Disks: 1* 128GB(?) SATA SDD.
1760 ### Xeon and Atom Servers
1763 1. Intel Xeon servers:
1764 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1765 - Chassis: SuperMicro SYS-7049GP-TRT.
1766 - Motherboard: SuperMicro X11DPG-QT.
1767 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1768 - RAM Memory: 16* 16GB DDR4-2666MHz.
1769 - Disks: 2* 1.6TB 6G SATA SSD.
1770 2. Intel Atom servers with Rangely processors.
1771 - 3 * Netgate XG-2758-1u
1772 - Chassis: Netgate XG-2758-1u
1773 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1774 - RAM Memory: 16GB ECC
1778 ### Network Interface Cards
1782 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1783 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1784 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1786 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1788 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1790 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1793 ### Pluggables and Cables
1799 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1800 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1806 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1817 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable