1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19 1. [Requirements](#requirements)
20 1. [Addressing](#addressing)
21 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24 1. [Server Types](#server-types)
25 1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30 1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38 1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39 1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40 1. [Per Testbed Wiring](#per-testbed-wiring)
41 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51 1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52 1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54 1. [Appliances](#appliances)
55 1. [Arm Servers](#arm-servers)
56 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57 1. [Network Interface Cards](#network-interface-cards)
58 1. [Pluggables and Cables](#pluggables-and-cables)
59 1. [Other Parts](#other-parts)
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
71 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0
73 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0
74 3. 1-Node-Thunderx2 dev tx2 na 1 1 0 0 0 0 0 0 1 0 0
75 4. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0
76 5. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0
77 6. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0
78 7. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0
79 8. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0
80 9. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0
81 10. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0
82 11. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0
83 12. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0
84 13. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2
85 14. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0
86 Totals: 22 35 18 12 19 1 2 3 1 2 2
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
156 ### 3-Node-MACCHIATObin Arm Marvell
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
163 ### 3-Node-Rangeley Atom Testbeds
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
174 For management purposes, each server must have following two ports
175 connected to the management network:
179 - IPMI - Intelligent Platform Management Interface.
180 - Required for access to embedded server management with WebUI, CLI,
181 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183 - hostOS management port for general system management.
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
193 - Subnet: 10.30.50.0/24
194 - Gateway: 10.30.50.1
195 - Broadcast: 10.30.50.255
196 - DNS1: 199.204.44.24
197 - DNS2: 199.204.47.54
199 - Subnet: 10.30.51.0/24
200 - Gateway: 10.30.51.1
201 - Broadcast: 10.30.51.255
202 - DNS1: 199.204.44.24
203 - DNS2: 199.204.47.54
206 To access these hosts, VPN connection is required.
208 ### LOM (IPMI) VLAN IP Addresses
211 ------------ | -------
214 10.30.50.2 | LF Reserved
215 10.30.50.3 | LF Reserved
216 10.30.50.4 | LF Reserved
217 10.30.50.5 | LF Reserved
218 10.30.50.6 | LF Reserved
219 10.30.50.7 | LF Reserved
220 10.30.50.8 | LF Reserved
221 10.30.50.9 | LF Reserved
222 10.30.50.10 | LF Reserved
223 10.30.50.11 | LF Reserved
224 10.30.50.12 | LF Reserved
225 10.30.50.13 | LF Reserved
226 10.30.50.14 | LF Reserved
227 10.30.50.15 | LF Reserved
229 10.30.50.17 | t1-sut1
230 10.30.50.18 | t1-sut2
232 10.30.50.21 | t2-sut1
233 10.30.50.22 | t2-sut2
235 10.30.50.25 | t3-sut1
236 10.30.50.26 | t3-sut-2
237 10.30.50.28 | s41-nomad
238 10.30.50.29 | s39-nomad
239 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
240 10.30.50.30 | s40-nomad
241 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
242 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
243 10.30.50.36 | s17-t33-sut1
244 10.30.50.37 | s18-t33-sut2
245 10.30.50.41 | s3-t21-sut1
246 10.30.50.42 | s4-t21-tg1
247 10.30.50.43 | s11-t31-sut1
248 10.30.50.44 | s12-t31-sut2
249 10.30.50.45 | s13-t31-tg1
250 10.30.50.46 | s19-t33t34-tg1
251 10.30.50.47 | s1-t11-sut1
252 10.30.50.48 | s2-t12-sut1
253 10.30.50.49 | s5-t22-sut1
254 10.30.50.50 | s6-t22-tg1
255 10.30.50.51 | s7-t23-sut1
256 10.30.50.52 | s8-t23-tg1
257 10.30.50.53 | s9-t24-sut1
258 10.30.50.54 | s10-t24-tg1
259 10.30.50.55 | s14-t32-sut1
260 10.30.50.56 | s15-t32-sut2
261 10.30.50.57 | s16-t32-tg1
262 10.30.50.58 | s25-t25-sut1
263 10.30.50.59 | s26-t25-tg1
264 10.30.50.69 | s27-t13-sut
265 10.30.50.255 | Broadcast
270 10.30.55.10 | s28-t26t35-tg1
271 10.30.55.11 | s29-t26-sut1
272 10.30.55.12 | s30-t35-sut1
273 10.30.55.13 | s31-t35-sut2
274 10.30.55.14 | server-type-c4-1
275 10.30.55.15 | server-type-c4-2
276 10.30.55.17 | s32-t14-sut1
277 10.30.55.18 | s33-t27-sut1
278 10.30.55.19 | s34-t27-tg1
279 10.30.55.20 | s35-t28-sut1
280 10.30.55.21 | s36-t28-tg1
281 10.30.55.22 | s37-t29-sut1
282 10.30.55.23 | s38-t29-tg1
283 10.30.55.255 | Broadcast
285 ### Management VLAN IP Addresses
288 ------------------------- | -------
291 10.30.51.2 | LF Reserved
292 10.30.51.3 | LF Reserved
293 10.30.51.4 | LF Reserved
294 10.30.51.5 | LF Reserved
295 10.30.51.6 | LF Reserved
296 10.30.51.7 | LF Reserved
297 10.30.51.8 | LF Reserved
298 10.30.51.9 | s22-t35-sut1 (netgate-1)
299 10.30.51.10 | s23-t35-sut2 (netgate-2)
300 10.30.51.11 | s24-t35-sut3 (netgate-3)
301 10.30.51.12 | softiron-1
302 10.30.51.13 | nomad1arm
303 10.30.51.14 | nomad2arm
304 10.30.51.15 | LF Reserved
306 10.30.51.17 | t1-sut1
307 10.30.51.18 | t1-sut2
309 10.30.51.21 | t2-sut1
310 10.30.51.22 | t2-sut2
312 10.30.51.25 | t3-sut1
313 10.30.51.26 | t3-sut-2
314 10.30.51.28 | s41-nomad
315 10.30.51.29 | s39-nomad
316 10.30.51.30 | s40-nomad
319 10.30.51.36 | s17-t33-sut1
320 10.30.51.37 | s18-t33-sut2
321 10.30.51.41 | s20-t34-sut1
322 10.30.51.42 | s21-t34-sut2
323 10.30.51.44 | s3-t21-sut1
324 10.30.51.45 | s4-t21-tg1
325 10.30.51.46 | s11-t31-sut1
326 10.30.51.47 | s12-t31-sut2
327 10.30.51.48 | s13-t31-tg1
328 10.30.51.49 | s19-t33t34-tg1
329 10.30.51.50 | s1-t11-sut1
330 10.30.51.51 | s2-t12-sut1
331 10.30.51.52 | s5-t22-sut1
332 10.30.51.53 | s6-t22-tg1
333 10.30.51.54 | s7-t23-sut1
334 10.30.51.55 | s8-t23-tg1
335 10.30.51.56 | s9-t24-sut1
336 10.30.51.57 | s10-t24-tg1
337 10.30.51.58 | s14-t32-sut1
338 10.30.51.59 | s15-t32-sut2
339 10.30.51.60 | s16-t32-tg1
340 10.30.51.61 | s25-t25-sut1
341 10.30.51.62 | s26-t25-tg1
342 10.30.51.69 | s27-t13-sut1
343 10.30.51.70-10.30.51.105 | FREE
344 10.30.51.106-10.30.51.180 | FREE
345 10.30.51.181-10.30.51.254 | FREE
346 10.30.51.255 | Broadcast
349 10.32.8.10 | s28-t26t35-tg1
350 10.32.8.11 | s29-t26-sut1
351 10.32.8.12 | s30-t35-sut1
352 10.32.8.13 | s31-t35-sut2
353 10.32.8.14 | server-type-c4-1
354 10.32.8.15 | server-type-c4-2
355 10.32.8.17 | s32-t14-sut1
356 10.32.8.18 | s33-t27-sut1
357 10.32.8.19 | s34-t27-tg1
358 10.32.8.20 | s35-t28-sut1
359 10.32.8.21 | s36-t28-tg1
360 10.32.8.22 | s37-t29-sut1
361 10.32.8.23 | s38-t29-tg1
362 10.32.8.255 | Broadcast
364 ## Server Specifications
368 FD.io CSIT lab contains following server types:
370 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
371 - Quantity: 6 servers.
372 - Physical connectivity:
373 - CIMC and host management ports.
374 - NIC ports connected in 3-node topologies.
375 - Main HW configuration:
376 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
377 - Processors: 2* E5-2699v3 2.3 GHz.
378 - RAM Memory: 16* 32GB DDR4-2133MHz.
379 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
380 - NICs configuration:
381 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
382 - PCIe Slot1: Cisco VIC 1385 2p40GE.
383 - PCIe Slot2: Intel NIC x520 2p10GE.
385 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
386 - PCIe Slot4: Intel NIC xl710 2p40GE.
387 - PCIe Slot5: Intel NIC x710 2p10GE.
388 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
389 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
390 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
391 - Quantity: 3 servers.
392 - Physical connectivity:
393 - CIMC and host management ports.
394 - NIC ports connected in 3-node topologies.
395 - Main HW configuration:
396 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
397 - Processors: 2* E5-2699v3 2.3 GHz.
398 - RAM Memory: 16* 32GB DDR4-2133MHz.
399 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
400 - NICs configuration:
401 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
402 - PCIe Slot1: Intel NIC xl710 2p40GE.
403 - PCIe Slot2: Intel NIC x710 2p10GE.
404 - PCIe Slot3: Intel NIC x710 2p10GE.
405 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
406 - PCIe Slot4: Intel NIC xl710 2p40GE.
407 - PCIe Slot5: Intel NIC x710 2p10GE.
408 - PCIe Slot6: Intel NIC x710 2p10GE.
410 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
411 - Quantity: 3 servers.
412 - Physical connectivity:
413 - CIMC and host management ports.
414 - no NIC ports, standalone setup.
415 - Main HW configuration:
416 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
417 - Processors: 2* E5-2699v3 2.3 GHz.
418 - RAM Memory: 16* 32GB DDR4-2133MHz.
419 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
420 - NICs configuration:
421 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
423 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
426 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
428 - Physical connectivity:
429 - IPMI and host management ports.
430 - NIC ports connected into 2-node and 3-node topologies.
431 - Main HW configuration:
432 - Chassis: SuperMicro SYS-7049GP-TRT.
433 - Motherboard: SuperMicro X11DPG-QT.
434 - Processors: 2* Intel Platinum 8180 2.5 GHz.
435 - RAM Memory: 16* 16GB DDR4-2666MHz.
436 - Disks: 2* 1.6TB 6G SATA SSD.
437 - NICs configuration:
438 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
439 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
440 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
441 - PCIe Slot9 5e:00.xx: empty.
442 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
443 - PCIe Slot6 86:00.xx: empty.
444 - PCIe Slot8 af:00.xx: empty.
445 - PCIe Slot10 d8:00.xx: empty.
446 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
448 - Physical connectivity:
449 - IPMI and host management ports.
450 - NIC ports connected into 2-node and 3-node topologies.
451 - Main HW configuration:
452 - Chassis: SuperMicro SYS-7049GP-TRT.
453 - Motherboard: SuperMicro X11DPG-QT.
454 - Processors: 2* Intel Platinum 8180 2.5 GHz.
455 - RAM Memory: 16* 16GB DDR4-2666MHz.
456 - Disks: 2* 1.6TB 6G SATA SSD.
457 - NICs configuration:
458 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
459 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
460 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
461 - PCIe Slot9 5e:00.xx: empty.
462 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
463 - PCIe Slot6 86:00.xx: empty.
464 - PCIe Slot8 af:00.xx: empty.
465 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
466 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
468 - Physical connectivity:
469 - IPMI(?) and host management ports.
470 - NIC ports connected into 3-node topology.
471 - Main HW configuration:
472 - Chassis: Huawei TaiShan 2280.
473 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
474 - RAM Memory: 8* 16GB DDR4-2400MT/s
475 - Disks: 1* 4TB SATA HDD
476 - NICs configuration:
477 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
478 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
479 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
481 - Physical connectivity:
482 - Host management ports.
483 - NIC ports connected into 2-node and 3-node topologies.
484 - Main HW configuration:
485 - Chassis: MACCHIATObin.
486 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
487 - RAM Memory: 1* 16GB DDR4
488 - Disks: 1* 128GB(?) SATA SDD
489 - NICs configuration:
490 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
491 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
492 - Quantity: TBD based on testbed allocation.
493 - Physical connectivity:
494 - Management: serial Port (usb) for console
495 - NIC ports connected into 2-node.
496 - Main HW configuration:
497 - Chassis: Netgate XG-2758-1u
498 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
499 - RAM Memory: 16GB ECC
501 - NICs configuration:
502 - 2x 10Gb Intel 82599ES
504 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
506 - Physical connectivity:
507 - IPMI and host management ports.
508 - NIC ports connected into 2-node and 3-node topologies.
509 - Main HW configuration:
510 - Chassis: SuperMicro SYS-7049GP-TRT.
511 - Motherboard: SuperMicro X11DPG-QT.
512 - Processors: 2* Intel Platinum 8180 2.5 GHz.
513 - RAM Memory: 16* 16GB DDR4-2666MHz.
514 - Disks: 2* 1.6TB 6G SATA SSD.
515 - NICs configuration:
516 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
517 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
518 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
519 - PCIe Slot9 5e:00.xx: empty.
520 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
521 - PCIe Slot6 86:00.xx: empty.
522 - PCIe Slot8 af:00.xx: empty.
523 - PCIe Slot10 d8:00.xx: empty.
524 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
526 - Physical connectivity:
527 - Host management interface: 10/100/1000-BaseT.
528 - 8-port 10GE SFP+ integrated NIC.
529 - Main HW configuration:
530 - Chassis: PS10GE4NG.
531 - Motherboard: SuperMicro X11DPG-QT.
532 - Processors: Quad-Core, Intel Processor.
533 - HW accelerators: FPGA offload.
535 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
536 - Physical Interfaces: 4 * 10GE SFP+.
537 - Operating System: Native IxOS.
538 - Interface configuration:
543 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
545 - Physical connectivity:
546 - IPMI and host management ports.
548 - Main HW configuration:
549 - Chassis: SuperMicro SYS-7049GP-TRT.
550 - Motherboard: SuperMicro X11DPG-QT.
551 - Processors: 2* Intel Platinum 8180 2.5 GHz.
552 - RAM Memory: 16* 16GB DDR4-2666MHz.
553 - Disks: 2* 1.6TB 6G SATA SSD.
554 - NICs configuration:
555 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
556 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
557 - PCIe Slot4 3b:00.xx: empty.
558 - PCIe Slot9 5e:00.xx: empty.
559 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
560 - PCIe Slot6 86:00.xx: empty.
561 - PCIe Slot8 af:00.xx: empty.
562 - PCIe Slot10 d8:00.xx: empty.
563 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
565 - Physical connectivity:
566 - IPMI and host management ports.
567 - NIC ports connected into 1-node topologies.
568 - Main HW configuration:
569 - Chassis: Gigabyte R181-T90 1U
570 - Motheboard: MT91-FS1
571 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
572 - RAM Memory: 4* 32GB RDIMM
573 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
574 - NICs configuration:
576 - PCIe Slot1 05:00.xx: XL710-QDA2.
577 - PCIe Slot3 08:00.xx: XL710-QDA2.
579 - PCIe Slot6 85:00.xx: XL710-QDA2.
580 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
582 - Physical connectivity:
583 - IPMI and host management ports.
585 - Main HW configuration:
586 - Chassis: SuperMicro SYS-E300-9A
587 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
588 - RAM Memory: 32GB ECC
590 - NICs configuration:
591 - 2x 10Gb Intel x553 fiber ports
592 - 2x 10Gb Intel x553 copper ports
593 - 4x 1GB Intel I350 ports
595 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
597 - Physical connectivity:
598 - IPMI and host management ports.
599 - NIC ports connected into 1-node testbed topologies.
600 - Main HW configuration:
601 - Chassis: SuperMicro SYS-7049GP-TRT.
602 - Motherboard: SuperMicro X11DPG-QT.
603 - Processors: 2* Intel Platinum 8280 2.7 GHz.
604 - RAM Memory: 12* 16GB DDR4-2933.
605 - Disks: 2* 1.92TB SATA SSD.
606 - NICs configuration:
607 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
608 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
609 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
610 - PCIe Slot9 5e:00.xx: empty.
611 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
612 - PCIe Slot6 86:00.xx: empty.
613 - PCIe Slot8 af:00.xx: empty.
614 - PCIe Slot10 d8:00.xx: empty.
616 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
618 - Physical connectivity:
619 - IPMI and host management ports.
620 - NIC ports connected into 2-node testbed topologies.
621 - Main HW configuration:
622 - Chassis: SuperMicro SYS-7049GP-TRT.
623 - Motherboard: SuperMicro X11DPG-QT.
624 - Processors: 2* Intel Gold 6252N 2.3 GHz.
625 - RAM Memory: 12* 16GB DDR4-2933.
626 - Disks: 2* 1.92TB SATA SSD.
627 - NICs configuration:
628 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
629 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
630 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
631 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
632 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
633 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
634 - PCIe Slot6 86:00.xx: empty.
635 - PCIe Slot8 af:00.xx: empty.
636 - PCIe Slot10 d8:00.xx: empty.
637 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
639 - Physical connectivity:
640 - IPMI and host management ports.
641 - NIC ports connected into 2-node testbed topologies.
642 - Main HW configuration:
643 - Chassis: SuperMicro SYS-7049GP-TRT.
644 - Motherboard: SuperMicro X11DPG-QT.
645 - Processors: 2* Intel Platinum 8280 2.7 GHz.
646 - RAM Memory: 12* 16GB DDR4-2933.
647 - Disks: 2* 1.92TB SATA SSD.
648 - NICs configuration:
649 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
650 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
651 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
652 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
653 - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
654 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
655 - PCIe Slot6 86:00.xx: empty.
656 - PCIe Slot8 af:00.xx: empty.
657 - PCIe Slot10 d8:00.xx: empty.
659 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
661 - Physical connectivity:
662 - CIMC and host management ports.
663 - no NIC ports, standalone setup.
664 - Main HW configuration:
665 - Chassis: SuperMicro 1029P-WTRT.
666 - Motherboard: SuperMicro X11DDW-NT.
667 - Processors: 2* Intel Platinum 8280 2.7 GHz.
668 - RAM Memory: 12* 16GB DDR4-2933.
669 - Disks: 4* 1.92TB SATA SSD.
670 - NICs configuration:
677 ### Naming Convention
679 Following naming convention is used within this page to specify physical
680 connectivity and wiring across defined CSIT testbeds:
683 - testbedname: testbedN.
685 - traffic-generator: tN-tgW.
686 - system-under-testX: tN-sutX.
691 - N - testbed number.
692 - tgW - server acts as traffic-generator with W index.
693 - sutX - server acts as system-under-test with X index.
694 - Y - PCIe slot number denoting a NIC card number within the host.
695 - Z - port number on the NIC card.
698 ## Testbeds Configuration
700 ### Per Testbed Server Allocation and Naming
702 #### 1-Node-Skylake Servers (1n-skx) PROD
705 - SUT [Server-Type-B6]:
706 - testbedname: testbed11.
707 - hostname: s1-t11-sut1.
708 - IPMI IP: 10.30.50.47
709 - Host IP: 10.30.51.50
711 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
712 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
713 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
714 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
715 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
716 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
717 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
718 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
719 - SUT [Server-Type-B6]:
720 - testbedname: testbed12.
721 - hostname: s2-t12-sut1.
722 - IPMI IP: 10.30.50.48
723 - Host IP: 10.30.51.51
725 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
726 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
727 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
728 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
729 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
730 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
731 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
732 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
735 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
738 - SUT [Server-Type-B9]:
739 - testbedname: testbed13.
740 - hostname: s27-t13-sut1.
741 - IPMI IP: 10.30.50.69
742 - Host IP: 10.30.51.69
744 - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
745 - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
746 - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
747 - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
748 - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
749 - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
752 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
755 - SUT [Server-Type-C1]:
756 - testbedname: testbed11.
757 - hostname: s32-t14-sut1.
758 - IPMI IP: 10.30.55.17
759 - Host IP: 10.32.8.17
761 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
762 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
763 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
764 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
765 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
766 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
767 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
768 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
771 #### 2-Node-Skylake Servers (2n-skx) PROD
774 - SUT [Server-Type-B1]:
775 - testbedname: testbed21.
776 - hostname: s3-t21-sut1.
777 - IPMI IP: 10.30.50.41
778 - Host IP: 10.30.51.44
780 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
781 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
782 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
783 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
784 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
785 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
786 - TG [Server-Type-B2]:
787 - testbedname: testbed21.
788 - hostname: s4-t21-tg1.
789 - IPMI IP: 10.30.50.42
790 - Host IP: 10.30.51.45
792 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
793 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
794 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
795 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
796 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
797 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
798 - SUT [Server-Type-B1]:
799 - testbedname: testbed22.
800 - hostname: s5-t22-sut1.
801 - IPMI IP: 10.30.50.49
802 - Host IP: 10.30.51.52
804 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
805 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
806 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
807 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
808 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
809 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
810 - TG [Server-Type-B2]:
811 - testbedname: testbed22.
812 - hostname: s6-t22-tg1.
813 - IPMI IP: 10.30.50.50
814 - Host IP: 10.30.51.53
816 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
817 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
818 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
819 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
820 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
821 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
822 - SUT [Server-Type-B1]:
823 - testbedname: testbed23.
824 - hostname: s7-t23-sut1.
825 - IPMI IP: 10.30.50.51
826 - Host IP: 10.30.51.54
828 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
829 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
830 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
831 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
832 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
833 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
834 - TG [Server-Type-B2]:
835 - testbedname: testbed23.
836 - hostname: s8-t23-tg1.
837 - IPMI IP: 10.30.50.52
838 - Host IP: 10.30.51.55
840 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
841 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
842 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
843 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
844 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
845 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
846 - SUT [Server-Type-B1]:
847 - testbedname: testbed24.
848 - hostname: s9-t24-sut1.
849 - IPMI IP: 10.30.50.53
850 - Host IP: 10.30.51.56
852 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
853 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
854 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
855 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
856 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
857 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
858 - TG [Server-Type-B2]:
859 - testbedname: testbed24.
860 - hostname: s10-t24-tg1.
861 - IPMI IP: 10.30.50.54
862 - Host IP: 10.30.51.57
864 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
865 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
866 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
867 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
868 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
869 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
872 #### 2-Node-Denverton Servers (2n-dnv) WIP
874 Note: ServerB28 (TG) is shared between testbed26 & testbed35
877 - TG [Server-Type-B2]:
878 - testbednames: testbed26 and testbed35.
879 - hostname: s28-t26t35-tg1.
880 - IPMI IP: 10.30.55.10
881 - Host IP: 10.32.8.10
883 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
884 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
885 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
886 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
887 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
888 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
889 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
890 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
891 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
892 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
893 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
894 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
895 - SUT [Server-Type-B10]:
896 - testbednames: testbed26.
897 - hostname: s29-t26-sut1.
898 - IPMI IP: 10.30.55.11
899 - Host IP: 10.32.8.11
901 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
902 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
903 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
904 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
907 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
910 - SUT [Server-Type-B8]:
911 - testbedname: testbed25.
912 - hostname: s25-t25-sut1.
913 - IPMI IP: 10.30.50.58
914 - Host IP: 10.30.51.61
916 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
917 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
918 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
919 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
920 - TG [Server-Type-B7]:
921 - testbedname: testbed25.
922 - hostname: s26-t25-tg1.
923 - IPMI IP: 10.30.50.59
924 - Host IP: 10.30.51.62
926 - s26-t25-tg1-p1 - 10GE-port1.
927 - s26-t25-tg1-p2 - 10GE-port2.
928 - s26-t25-tg1-p3 - 10GE-port3.
929 - s26-t25-tg1-p4 - 10GE-port4.
932 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
935 - SUT [Server-Type-C2]:
936 - testbedname: testbed27.
937 - hostname: s33-t27-sut1.
938 - IPMI IP: 10.30.55.18
939 - Host IP: 10.32.8.18
941 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
942 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
943 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
944 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
945 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
946 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
947 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
948 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
949 - TG [Server-Type-C3]:
950 - testbedname: testbed27.
951 - hostname: s34-t27-tg1.
952 - IPMI IP: 10.30.55.19
953 - Host IP: 10.32.8.19
955 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
956 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
957 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
958 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
959 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
960 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
961 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
962 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
963 - SUT [Server-Type-C2]:
964 - testbedname: testbed28.
965 - hostname: s35-t28-sut1.
966 - IPMI IP: 10.30.55.20
967 - Host IP: 10.32.8.20
969 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
970 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
971 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
972 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
973 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
974 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
975 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
976 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
977 - TG [Server-Type-C3]:
978 - testbedname: testbed28.
979 - hostname: s36-t28-tg1.
980 - IPMI IP: 10.30.55.21
981 - Host IP: 10.32.8.21
983 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
984 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
985 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
986 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
987 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
988 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
989 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
990 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
991 - SUT [Server-Type-C2]:
992 - testbedname: testbed29.
993 - hostname: s37-t29-sut1.
994 - IPMI IP: 10.30.55.22
995 - Host IP: 10.32.8.22
997 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
998 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
999 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1000 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1001 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1002 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1003 - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1004 - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1005 - TG [Server-Type-C3]:
1006 - testbedname: testbed29.
1007 - hostname: s38-t29-tg1.
1008 - IPMI IP: 10.30.55.23
1009 - Host IP: 10.32.8.23
1011 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1012 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1013 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1014 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1015 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1016 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1017 - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1018 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1021 #### 3-Node-Haswell Servers (3n-hsw) PROD
1024 1. SUT [Server-Type-A1]:
1025 - testbedname: testbed1.
1026 - hostname: t1-sut1.
1027 - CIMC IP: 10.30.50.17
1028 - Host IP: 10.30.51.17
1030 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1031 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1032 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1033 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1034 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1035 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1036 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1037 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1038 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1039 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1040 2. SUT [Server-Type-A1]:
1041 - testbedname: testbed1.
1042 - hostname: t1-sut2.
1043 - CIMC IP: 10.30.50.18
1044 - Host IP: 10.30.51.18
1046 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1047 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1048 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1049 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1050 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1051 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1052 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1053 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1054 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1055 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1056 3. TG [Server-Type-A2]:
1057 - testbedname: testbed1.
1059 - CIMC IP: 10.30.50.16
1060 - Host IP: 10.30.51.16
1062 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1063 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1064 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1065 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1066 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1067 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1068 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1069 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1070 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1071 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1072 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1073 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1074 4. SUT [Server-Type-A1]:
1075 - testbedname: testbed2.
1076 - hostname: t2-sut1.
1077 - CIMC IP: 10.30.50.21
1078 - Host IP: 10.30.51.21
1080 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1081 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1082 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1083 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1084 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1085 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1086 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1087 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1088 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1089 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1090 5. SUT [Server-Type-A1]:
1091 - testbedname: testbed2.
1092 - hostname: t2-sut2.
1093 - CIMC IP: 10.30.50.22
1094 - Host IP: 10.30.51.22
1096 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1097 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1098 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1099 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1100 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1101 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1102 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1103 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1104 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1105 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1106 6. TG [Server-Type-A2]:
1107 - testbedname: testbed2.
1109 - CIMC IP: 10.30.50.20
1110 - Host IP: 10.30.51.20
1112 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1113 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1114 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1115 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1116 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1117 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1118 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1119 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1120 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1121 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1122 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1123 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1124 7. SUT [Server-Type-A1]:
1125 - testbedname: testbed3.
1126 - hostname: t3-sut1.
1127 - CIMC IP: 10.30.50.25
1128 - Host IP: 10.30.51.25
1130 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1131 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1132 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1133 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1134 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1135 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1136 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1137 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1138 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1139 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1140 8. SUT [Server-Type-A1]:
1141 - testbedname: testbed3.
1142 - hostname: t3-sut2.
1143 - CIMC IP: 10.30.50.26
1144 - Host IP: 10.30.51.26
1146 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1147 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1148 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1149 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1150 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1151 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1152 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1153 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1154 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1155 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1156 9. TG [Server-Type-A2]:
1157 - testbedname: testbed3.
1159 - CIMC IP: 10.30.50.24
1160 - Host IP: 10.30.51.24
1162 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1163 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1164 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1165 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1166 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1167 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1168 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1169 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1170 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1171 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1172 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1173 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1176 #### 3-Node-Skylake Servers (3n-skx) PROD
1179 - ServerB11 [Server-Type-B1]:
1180 - testbedname: testbed31.
1181 - hostname: s11-t31-sut1.
1182 - IPMI IP: 10.30.50.43
1183 - Host IP: 10.30.51.46
1185 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1186 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1187 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1188 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1189 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1190 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1191 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1192 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1193 - ServerB12 [Server-Type-B1]:
1194 - testbedname: testbed31.
1195 - hostname: s12-t31-sut2.
1196 - IPMI IP: 10.30.50.44
1197 - Host IP: 10.30.51.47
1199 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1200 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1201 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1202 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1203 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1204 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1205 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1206 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1207 - ServerB13 [Server-Type-B2]:
1208 - testbedname: testbed31.
1209 - hostname: s13-t31-tg1.
1210 - IPMI IP: 10.30.50.45
1211 - Host IP: 10.30.51.48
1213 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1214 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1215 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1216 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1217 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1218 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1219 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1220 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1221 - ServerB14 [Server-Type-B1]:
1222 - testbedname: testbed32.
1223 - hostname: s14-t32-sut1.
1224 - IPMI IP: 10.30.50.55
1225 - Host IP: 10.30.51.58
1227 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1228 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1229 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1230 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1231 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1232 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1233 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1234 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1235 - ServerB15 [Server-Type-B1]:
1236 - testbedname: testbed32.
1237 - hostname: s15-t32-sut2.
1238 - IPMI IP: 10.30.50.56
1239 - Host IP: 10.30.51.59
1241 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1242 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1243 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1244 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1245 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1246 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1247 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1248 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1249 - ServerB16 [Server-Type-B2]:
1250 - testbedname: testbed32.
1251 - hostname: s16-t32-tg1.
1252 - IPMI IP: 10.30.50.57
1253 - Host IP: 10.30.51.60
1255 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1256 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1257 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1258 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1259 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1260 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1261 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1262 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1265 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1267 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1270 - ServerB22 [Server-Type-B5]:
1271 - testbedname: testbed35.
1272 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1273 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1274 - Host IP: 10.30.51.9
1276 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1277 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1279 - ServerB23 [Server-Type-B5]:
1280 - testbedname: testbed35.
1281 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1282 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1283 - Host IP: 10.30.51.10
1285 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1286 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1288 - ServerB24 [Server-Type-B5]:
1289 - testbedname: testbed35.
1290 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1291 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1292 - Host IP: 10.30.51.11
1294 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1295 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1299 #### 3-Node-Taishan Servers (3n-tsh) WIP
1301 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1304 - ServerB17 [Server-Type-B3]:
1305 - testbedname: testbed33.
1306 - hostname: s17-t33-sut1.
1307 - IPMI IP: 10.30.50.36
1308 - Host IP: 10.30.51.36
1310 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1311 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1312 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1313 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1314 - ServerB18 [Server-Type-B3]:
1315 - testbedname: testbed33.
1316 - hostname: s18-t33-sut2.
1317 - IPMI IP: 10.30.50.37
1318 - Host IP: 10.30.51.37
1320 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1321 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1322 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1323 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1324 - ServerB19 [Server-Type-B2]:
1325 - testbednames: testbed33 and testbed34.
1326 - hostname: s19-t33t34-tg1.
1327 - IPMI IP: 10.30.50.46
1328 - Host IP: 10.30.51.49
1330 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1331 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1332 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1333 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1334 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1335 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1336 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1337 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1338 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1339 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1340 - ServerB20 [Server-Type-B4]:
1341 - testbedname: testbed34.
1342 - hostname: s20-t34-sut1.
1344 - Host IP: 10.30.51.41
1346 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1347 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1348 - ServerB21 [Server-Type-B4]:
1349 - testbedname: testbed34.
1350 - hostname: s21-t34-sut2.
1352 - Host IP: 10.30.51.42
1354 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1355 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1358 #### 3-Node-Denverton Servers (3n-dnv) WIP
1361 - ServerB30 [Server-Type-B10]:
1362 - testbednames: testbed35.
1363 - hostname: s30-t35-sut1.
1364 - IPMI IP: 10.30.55.12
1365 - Host IP: 10.32.8.12
1367 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1368 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1369 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1370 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1371 - ServerB31 [Server-Type-B10]:
1372 - testbednames: testbed35.
1373 - hostname: s31-t35-sut2.
1374 - IPMI IP: 10.30.55.13
1375 - Host IP: 10.32.8.13
1377 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1378 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1379 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1380 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1383 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1389 ### Per Testbed Wiring
1391 #### 1-Node-Skylake Wiring (1n-skx) PROD
1395 - ring1 10GE-ports x710-4p10GE:
1396 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1397 - ring2 10GE-ports x710-4p10GE:
1398 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1399 - ring3 10GE-ports x710-4p10GE:
1400 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1401 - ring4 10GE-ports x710-4p10GE:
1402 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1404 - ring1 10GE-ports x710-4p10GE:
1405 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1406 - ring2 10GE-ports x710-4p10GE:
1407 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1408 - ring3 10GE-ports x710-4p10GE:
1409 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1410 - ring4 10GE-ports x710-4p10GE:
1411 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1414 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1418 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1419 - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1420 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1421 - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1422 - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1423 - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1426 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1430 - ring1 10GE-ports x710-4p10GE:
1431 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1432 - ring2 10GE-ports x710-4p10GE:
1433 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1434 - ring3 10GE-ports x710-4p10GE:
1435 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1436 - ring4 10GE-ports x710-4p10GE:
1437 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1440 #### 2-Node-Skylake Wiring (2n-skx) PROD
1444 - ring1 10GE-ports x710-4p10GE on SUT:
1445 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1446 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1447 - ring2 10GE-ports x710-4p10GE on SUT:
1448 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1449 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1450 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1451 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1452 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1454 - ring1 10GE-ports x710-4p10GE on SUT:
1455 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1456 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1457 - ring2 10GE-ports x710-4p10GE on SUT:
1458 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1459 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1460 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1461 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1462 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1464 - ring1 10GE-ports x710-4p10GE on SUT:
1465 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1466 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1467 - ring2 10GE-ports x710-4p10GE on SUT:
1468 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1469 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1470 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1471 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1472 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1474 - ring1 10GE-ports x710-4p10GE on SUT:
1475 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1476 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1477 - ring2 10GE-ports x710-4p10GE on SUT:
1478 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1479 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1480 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1481 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1482 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1485 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1489 - ring1 10GE-ports x553 copper port on SUT:
1490 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1491 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1492 - ring2 10GE-ports x553 fiber port on SUT:
1493 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1494 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1497 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1501 - link1 10GE-port x710-4p10GE on SUT:
1502 - t25-tg1-p1 to t25-sut1-c2/p1.
1503 - link2 10GE-port x710-4p10GE on SUT:
1504 - t25-tg1-p2 to t25-sut1-c2/p2.
1505 - link3 10GE-port x710-4p10GE on SUT:
1506 - t25-tg1-p3 to t25-sut1-c2/p3.
1507 - link4 10GE-port x710-4p10GE on SUT:
1508 - t25-tg1-p4 to t25-sut1-c2/p4.
1511 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1515 - ring1 10GE-ports x710-4p10GE on SUT:
1516 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1517 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1518 - ring2 10GE-ports x710-4p10GE on SUT:
1519 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1520 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1521 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1522 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1523 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1524 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1525 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1526 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1528 - ring1 10GE-ports x710-4p10GE on SUT:
1529 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1530 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1531 - ring2 10GE-ports x710-4p10GE on SUT:
1532 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1533 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1534 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1535 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1536 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1537 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1538 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1539 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1541 - ring1 10GE-ports x710-4p10GE on SUT:
1542 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1543 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1544 - ring2 10GE-ports x710-4p10GE on SUT:
1545 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1546 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1547 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1548 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1549 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1550 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1551 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1552 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1555 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1559 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1560 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1561 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1562 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1563 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1564 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1565 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1566 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1567 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1568 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1569 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1570 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1571 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1572 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1573 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1574 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1575 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1576 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1577 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1578 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1579 - TG loopback ports Intel NIC x710 2p10GE
1580 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1583 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1584 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1585 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1586 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1587 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1588 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1589 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1590 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1591 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1592 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1593 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1594 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1595 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1596 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1597 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1598 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1599 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1600 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1601 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1602 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1603 - TG loopback ports Intel NIC x710 2p10GE
1604 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1607 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1608 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1609 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1610 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1611 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1612 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1613 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1614 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1615 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1616 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1617 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1618 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1619 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1620 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1621 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1622 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1623 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1624 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1625 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1626 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1627 - TG loopback ports Intel NIC x710 2p10GE
1628 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1631 #### 3-Node-Skylake Wiring (3n-skx) PROD
1635 - ring1 10GE-ports x710-4p10GE on SUTs:
1636 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1637 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1638 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1639 - ring2 10GE-ports x710-4p10GE on SUT:
1640 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1641 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1642 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1643 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1644 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1645 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1646 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1647 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1648 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1649 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1650 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1651 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1652 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1653 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1655 - ring1 10GE-ports x710-4p10GE on SUTs:
1656 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1657 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1658 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1659 - ring2 10GE-ports x710-4p10GE on SUT:
1660 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1661 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1662 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1663 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1664 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1665 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1666 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1667 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1668 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1669 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1670 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1671 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1672 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1673 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1676 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1682 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1686 - ring1 10GE-ports x520-2p10GE on SUTs:
1687 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1688 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1689 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1690 - ring2 25GE-ports cx4-2p25GE on SUTs:
1691 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1692 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1693 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1696 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1700 - ring1 10GE-ports Marvell on SUTs:
1701 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1702 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1703 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1706 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1710 - ring1 10GE-ports x553 copper port on SUTs:
1711 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1712 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1713 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1714 - ring2 10GE-ports x553 fiber port on SUTs:
1715 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1716 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1717 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1725 1. Ixia PerfectStorm One Appliance
1727 - Chassis: PS10GE4NG.
1728 - Motherboard: SuperMicro X11DPG-QT.
1729 - Processors: Quad-Core, Intel Processor.
1730 - HW accelerators: FPGA offload.
1732 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1733 - Physical Interfaces: 4 * 10GE SFP+.
1734 - Operating System: Native IxOS.
1740 1. Arm Cortex A-72 servers
1742 - Chassis: Marvell ThunderX2
1743 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1744 - RAM Memory: 4* 32GB RDIMM
1745 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1746 - 2 * Huawei TaiShan 2280.
1747 - Chassis: Huawei TaiShan 2280.
1748 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1749 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1750 - Disks: 1* 4TB SATA HDD.
1752 - Chassis: MACCHIATObin.
1753 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1754 - RAM Memory: 1* 16GB DDR4.
1755 - Disks: 1* 128GB(?) SATA SDD.
1758 ### Xeon and Atom Servers
1761 1. Intel Xeon servers:
1762 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1763 - Chassis: SuperMicro SYS-7049GP-TRT.
1764 - Motherboard: SuperMicro X11DPG-QT.
1765 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1766 - RAM Memory: 16* 16GB DDR4-2666MHz.
1767 - Disks: 2* 1.6TB 6G SATA SSD.
1768 2. Intel Atom servers with Rangely processors.
1769 - 3 * Netgate XG-2758-1u
1770 - Chassis: Netgate XG-2758-1u
1771 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1772 - RAM Memory: 16GB ECC
1776 ### Network Interface Cards
1780 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1781 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1782 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1784 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1786 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1788 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1791 ### Pluggables and Cables
1797 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1798 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1804 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1815 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable