lab: update Arm lab docs
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
17    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
18 1. [Server Management](#server-management)
19    1. [Requirements](#requirements)
20    1. [Addressing](#addressing)
21    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24    1. [Server Types](#server-types)
25    1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
30       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
31       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32       1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
33       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
35       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
36       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
37       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
38       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
39       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
40    1. [Per Testbed Wiring](#per-testbed-wiring)
41       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
43       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
44       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45       1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
46       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
49       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
50       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
51       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
52       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
53 1. [Inventory](#inventory)
54    1. [Appliances](#appliances)
55    1. [Arm Servers](#arm-servers)
56    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57    1. [Network Interface Cards](#network-interface-cards)
58    1. [Pluggables and Cables](#pluggables-and-cables)
59    1. [Other Parts](#other-parts)
60
61 ## Purpose
62
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
65
66 ## Testbeds Overview
67
68 ### Summary List
69
70 ```
71  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
72  1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0
73  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0
74  3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0
75  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    1    0
76  5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0
77  6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0
78  7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0
79  8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    6    0
80  9. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0
81 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0
82 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0
83 12. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0
84 13. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0
85 14. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    2
86                                  Totals: 25   31   15    4   19    1    2    3    3    2    7    2
87 ```
88
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
90
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
94
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
96
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
100
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
102
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
105
106 Used for FD.io VPP_Device functional driver tests.
107
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
109
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
114
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
116
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
121
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
123
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
128
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
130
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
135
136 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
137
138 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
139 one TG (Server-Type-D2) connected in a 2-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
142
143 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
144
145 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
146 one TG (Server-Type-E31) connected in a 2-node circular topology
147 ([Server Types](#server-types)).
148 Used for FD.io performance tests.
149
150 ### 3-Node-Haswell Xeon Intel (3n-hsw)
151
152 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
153 TG (Server-Type-A2) connected in a 3-node circular topology
154 ([Server Types](#server-types)).
155 Used for FD.io performance tests.
156
157 ### 3-Node-Skylake Xeon Intel (3n-skx)
158
159 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
160 TG (Server-Type-B2) connected in a 3-node circular topology.
161 Used for FD.io performance tests.
162
163 ### 3-Node-Rangeley Atom Testbeds
164
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
169
170 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
171
172 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
173 TG (Server-Type-E31) connected in a 3-node circular topology
174 ([Server Types](#server-types)).
175 Used for FD.io performance tests.
176
177 ## Server Management
178
179 ### Requirements
180
181 For management purposes, each server must have following two ports
182 connected to the management network:
183
184 ```
185 - 1GE IPMI port
186   - IPMI - Intelligent Platform Management Interface.
187   - Required for access to embedded server management with WebUI, CLI,
188     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
189 - 1GE/10GE/40GE management port
190   - hostOS management port for general system management.
191 ```
192
193 ### Addressing
194
195 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
196 Management port, which are connected to two different VLANs.
197
198 ```
199 1. LOM (IPMI) VLAN:
200     - Subnet: 10.30.50.0/24
201     - Gateway: 10.30.50.1
202     - Broadcast: 10.30.50.255
203     - DNS1: 199.204.44.24
204     - DNS2: 199.204.47.54
205 2. Management Vlan:
206     - Subnet: 10.30.51.0/24
207     - Gateway: 10.30.51.1
208     - Broadcast: 10.30.51.255
209     - DNS1: 199.204.44.24
210     - DNS2: 199.204.47.54
211 ```
212
213 To access these hosts, VPN connection is required.
214
215 ### LOM (IPMI) VLAN IP Addresses
216
217 Name         | Comment
218 ------------ | -------
219 10.30.50.0   | network
220 10.30.51.1   | Router
221 10.30.50.2   | LF Reserved
222 10.30.50.3   | LF Reserved
223 10.30.50.4   | LF Reserved
224 10.30.50.5   | LF Reserved
225 10.30.50.6   | LF Reserved
226 10.30.50.7   | LF Reserved
227 10.30.50.8   | LF Reserved
228 10.30.50.9   | LF Reserved
229 10.30.50.10  | LF Reserved
230 10.30.50.11  | LF Reserved
231 10.30.50.12  | LF Reserved
232 10.30.50.13  | LF Reserved
233 10.30.50.14  | LF Reserved
234 10.30.50.15  | LF Reserved
235 10.30.50.22  | s42-nomad
236 10.30.50.24  | s43-nomad
237 10.30.50.25  | s44-nomad
238 10.30.50.26  | s45-nomad
239 10.30.50.28  | s41-nomad
240 10.30.50.29  | s39-nomad
241 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
242 10.30.50.30  | s40-nomad
243 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
244 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
245 10.30.50.36  | s17-t33-sut1
246 10.30.50.37  | s18-t33-sut2
247 10.30.50.38  | fdio-marvell-dev
248 10.30.50.39  | s53-nomad
249 10.30.50.40  | s54-nomad
250 10.30.50.41  | s3-t21-sut1
251 10.30.50.42  | s4-t21-tg1
252 10.30.50.43  | s11-t31-sut1
253 10.30.50.44  | s12-t31-sut2
254 10.30.50.45  | s13-t31-tg1
255 10.30.50.46  | s19-t33t211-tg1
256 10.30.50.47  | s1-t11-sut1
257 10.30.50.48  | s2-t12-sut1
258 10.30.50.49  | s5-t22-sut1
259 10.30.50.50  | s6-t22-tg1
260 10.30.50.51  | s7-t23-sut1
261 10.30.50.52  | s8-t23-tg1
262 10.30.50.53  | s9-t24-sut1
263 10.30.50.54  | s10-t24-tg1
264 10.30.50.55  | s14-t32-sut1
265 10.30.50.56  | s15-t32-sut2
266 10.30.50.57  | s16-t32-tg1
267 10.30.50.58  | s25-t25-sut1
268 10.30.50.59  | s26-t25-tg1
269 10.30.50.65  | s52-nomad
270 10.30.50.66  | s51-nomad
271 10.30.50.67  | s49-nomad
272 10.30.50.68  | s50-nomad
273 10.30.50.69  | s27-t211-sut1
274 10.30.50.70  | s55-t13-sut1
275 10.30.50.71  | s56-t14-sut1
276 10.30.50.255 | Broadcast
277 10.30.55.0   | network
278 10.30.55.1   | Router
279 10.30.55.10  | s28-t26t35-tg1
280 10.30.55.11  | s29-t26-sut1
281 10.30.55.12  | s30-t35-sut1
282 10.30.55.13  | s31-t35-sut2
283 10.30.55.14  | s46-nomad
284 10.30.55.15  | s47-nomad
285 10.30.55.16  | s48-nomad
286 10.30.55.17  | s57-nomad
287 10.30.55.18  | s33-t27-sut1
288 10.30.55.19  | s34-t27-tg1
289 10.30.55.20  | s35-t28-sut1
290 10.30.55.21  | s36-t28-tg1
291 10.30.55.22  | s37-t29-sut1
292 10.30.55.23  | s38-t29-tg1
293 10.30.55.24  | s60-t210-sut1
294 10.30.55.25  | s61-t210-tg1
295 10.30.55.255 | Broadcast
296
297 ### Management VLAN IP Addresses
298
299 Name                      | Comment
300 ------------------------- | -------
301 10.30.51.0                | network
302 10.30.51.1                | Router
303 10.30.51.2                | LF Reserved
304 10.30.51.3                | LF Reserved
305 10.30.51.4                | LF Reserved
306 10.30.51.5                | LF Reserved
307 10.30.51.6                | LF Reserved
308 10.30.51.7                | LF Reserved
309 10.30.51.8                | LF Reserved
310 10.30.51.15               | LF Reserved
311 10.30.51.22               | s42-nomad
312 10.30.51.24               | s43-nomad
313 10.30.51.25               | s44-nomad
314 10.30.51.26               | s45-nomad
315 10.30.51.28               | s41-nomad
316 10.30.51.29               | s39-nomad
317 10.30.51.30               | s40-nomad
318 10.30.51.36               | s17-t33-sut1
319 10.30.51.37               | s18-t33-sut2
320 10.30.51.38               | fdio-marvell-dev
321 10.30.51.39               | s53-nomad
322 10.30.51.40               | s54-nomad
323 10.30.51.44               | s3-t21-sut1
324 10.30.51.45               | s4-t21-tg1
325 10.30.51.46               | s11-t31-sut1
326 10.30.51.47               | s12-t31-sut2
327 10.30.51.48               | s13-t31-tg1
328 10.30.51.49               | s19-t33t211-tg1
329 10.30.51.50               | s1-t11-sut1
330 10.30.51.51               | s2-t12-sut1
331 10.30.51.52               | s5-t22-sut1
332 10.30.51.53               | s6-t22-tg1
333 10.30.51.54               | s7-t23-sut1
334 10.30.51.55               | s8-t23-tg1
335 10.30.51.56               | s9-t24-sut1
336 10.30.51.57               | s10-t24-tg1
337 10.30.51.58               | s14-t32-sut1
338 10.30.51.59               | s15-t32-sut2
339 10.30.51.60               | s16-t32-tg1
340 10.30.51.61               | s25-t25-sut1
341 10.30.51.62               | s26-t25-tg1
342 10.30.51.65               | s52-nomad
343 10.30.51.66               | s51-nomad
344 10.30.51.67               | s49-nomad
345 10.30.51.68               | s50-nomad
346 10.30.51.69               | s27-t211-sut1
347 10.30.51.70               | s55-t13-sut1
348 10.30.51.71               | s56-t14-sut1
349 10.30.51.72-10.30.51.254  | FREE
350 10.30.51.255              | Broadcast
351 10.32.8.0                 | network
352 10.32.8.1                 | Router
353 10.32.8.10                | s28-t26t35-tg1
354 10.32.8.11                | s29-t26-sut1
355 10.32.8.12                | s30-t35-sut1
356 10.32.8.13                | s31-t35-sut2
357 10.32.8.14                | s46-nomad
358 10.32.8.15                | s47-nomad
359 10.32.8.16                | s48-nomad
360 10.32.8.17                | s57-nomad
361 10.32.8.18                | s33-t27-sut1
362 10.32.8.19                | s34-t27-tg1
363 10.32.8.20                | s35-t28-sut1
364 10.32.8.21                | s36-t28-tg1
365 10.32.8.22                | s37-t29-sut1
366 10.32.8.23                | s38-t29-tg1
367 10.32.8.24                | s60-t210-sut1
368 10.32.8.25                | s61-t210-tg1
369 10.32.8.255               | Broadcast
370
371 ## Server Specifications
372
373 ### Server Types
374
375 FD.io CSIT lab contains following server types:
376 ```
377 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
378     - Quantity: 6 servers.
379     - Physical connectivity:
380         - CIMC and host management ports.
381         - NIC ports connected in 3-node topologies.
382     - Main HW configuration:
383         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
384         - Processors: 2* E5-2699v3 2.3 GHz.
385         - RAM Memory: 16* 32GB DDR4-2133MHz.
386         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
387     - NICs configuration:
388         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
389             - PCIe Slot1: empty.
390             - PCIe Slot2: empty.
391             - PCIe Slot3: empty.
392         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
393             - PCIe Slot4: empty.
394             - PCIe Slot5: empty.
395             - PCIe Slot6: empty
396         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
397 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
398     - Quantity: 3 servers.
399     - Physical connectivity:
400         - CIMC and host management ports.
401         - NIC ports connected in 3-node topologies.
402     - Main HW configuration:
403         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
404         - Processors: 2* E5-2699v3 2.3 GHz.
405         - RAM Memory: 16* 32GB DDR4-2133MHz.
406         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
407     - NICs configuration:
408         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
409             - PCIe Slot1: empty.
410             - PCIe Slot2: empty.
411             - PCIe Slot3: empty.
412         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
413             - PCIe Slot4: empty.
414             - PCIe Slot5: empty.
415             - PCIe Slot6: empty
416         - MLOM slot: empty.
417 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
418     - Quantity: 3 servers.
419     - Physical connectivity:
420         - CIMC and host management ports.
421         - no NIC ports, standalone setup.
422     - Main HW configuration:
423         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
424         - Processors: 2* E5-2699v3 2.3 GHz.
425         - RAM Memory: 16* 32GB DDR4-2133MHz.
426         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
427     - NICs configuration:
428         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
429             - no cards.
430         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
431             - no cards.
432         - MLOM slot: empty.
433 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
434     - Quantity: ---
435     - Physical connectivity:
436         - IPMI and host management ports.
437         - NIC ports connected into 2-node and 3-node topologies.
438     - Main HW configuration:
439         - Chassis: SuperMicro SYS-7049GP-TRT.
440         - Motherboard: SuperMicro X11DPG-QT.
441         - Processors: 2* Intel Platinum 8180 2.5 GHz.
442         - RAM Memory: 16* 16GB DDR4-2666MHz.
443         - Disks: 2* 1.6TB 6G SATA SSD.
444     - NICs configuration:
445         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
446             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
447             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
448             - PCIe Slot9 5e:00.xx: empty.
449         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
450             - PCIe Slot6 86:00.xx: empty.
451             - PCIe Slot8 af:00.xx: empty.
452             - PCIe Slot10 d8:00.xx: empty.
453 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
454     - Quantity: ---
455     - Physical connectivity:
456         - IPMI and host management ports.
457         - NIC ports connected into 2-node and 3-node topologies.
458     - Main HW configuration:
459         - Chassis: SuperMicro SYS-7049GP-TRT.
460         - Motherboard: SuperMicro X11DPG-QT.
461         - Processors: 2* Intel Platinum 8180 2.5 GHz.
462         - RAM Memory: 16* 16GB DDR4-2666MHz.
463         - Disks: 2* 1.6TB 6G SATA SSD.
464     - NICs configuration:
465         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
466             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
467             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
468             - PCIe Slot9 5e:00.xx: empty.
469         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
470             - PCIe Slot6 86:00.xx: empty.
471             - PCIe Slot8 af:00.xx: empty.
472             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
473 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
474     - Quantity: TBD based on testbed allocation.
475     - Physical connectivity:
476         - Management: serial Port (usb) for console
477         - NIC ports connected into 2-node.
478     - Main HW configuration:
479         - Chassis: Netgate XG-2758-1u
480         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
481         - RAM Memory: 16GB ECC
482         - Disks: 150 GB
483     - NICs configuration:
484         - 2x 10Gb Intel 82599ES
485         - 4x 1GB Intel I354
486 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
487     - Quantity: 2.
488     - Physical connectivity:
489         - IPMI and host management ports.
490         - NIC ports connected into 1-node topologies.
491     - Main HW configuration:
492         - Chassis: SuperMicro SYS-7049GP-TRT.
493         - Motherboard: SuperMicro X11DPG-QT.
494         - Processors: 2* Intel Platinum 8180 2.5 GHz.
495         - RAM Memory: 16* 16GB DDR4-2666MHz.
496         - Disks: 2* 1.6TB 6G SATA SSD.
497     - NICs configuration:
498         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
499             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
500             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
501             - PCIe Slot9 5e:00.xx: empty.
502         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
503             - PCIe Slot6 86:00.xx: empty.
504             - PCIe Slot8 af:00.xx: empty.
505             - PCIe Slot10 d8:00.xx: empty.
506 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
507     - Quantity: 1.
508     - Physical connectivity:
509         - Host management interface: 10/100/1000-BaseT.
510         - 8-port 10GE SFP+ integrated NIC.
511     - Main HW configuration:
512         - Chassis: PS10GE4NG.
513         - Motherboard: SuperMicro X11DPG-QT.
514         - Processors: Quad-Core, Intel Processor.
515         - HW accelerators: FPGA offload.
516         - RAM Memory: 64GB.
517         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
518         - Physical Interfaces: 4 * 10GE SFP+.
519         - Operating System: Native IxOS.
520     - Interface configuration:
521         - Port-1: 10GE SFP+.
522         - Port-2: 10GE SFP+.
523         - Port-3: 10GE SFP+.
524         - Port-4: 10GE SFP+.
525 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
526     - Quantity: 1.
527     - Physical connectivity:
528         - IPMI and host management ports.
529         - NIC ports.
530     - Main HW configuration:
531         - Chassis: SuperMicro SYS-7049GP-TRT.
532         - Motherboard: SuperMicro X11DPG-QT.
533         - Processors: 2* Intel Platinum 8180 2.5 GHz.
534         - RAM Memory: 16* 16GB DDR4-2666MHz.
535         - Disks: 2* 1.6TB 6G SATA SSD.
536     - NICs configuration:
537         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
538             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
539             - PCIe Slot4 3b:00.xx: empty.
540             - PCIe Slot9 5e:00.xx: empty.
541         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
542             - PCIe Slot6 86:00.xx: empty.
543             - PCIe Slot8 af:00.xx: empty.
544             - PCIe Slot10 d8:00.xx: empty.
545 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
546     - Quantity: 4
547     - Physical connectivity:
548         - IPMI and host management ports.
549         - NIC ports.
550     - Main HW configuration:
551         - Chassis: SuperMicro SYS-E300-9A
552         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
553         - RAM Memory: 32GB ECC
554         - Disks: 480 GB
555     - NICs configuration:
556         - 2x 10Gb Intel x553 fiber ports
557         - 2x 10Gb Intel x553 copper ports
558         - 4x 1GB Intel I350 ports
559 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
560     - Quantity: 1.
561     - Physical connectivity:
562         - IPMI and host management ports.
563         - NIC ports connected into 1-node testbed topologies.
564     - Main HW configuration:
565         - Chassis: SuperMicro SYS-7049GP-TRT.
566         - Motherboard: SuperMicro X11DPG-QT.
567         - Processors: 2* Intel Platinum 8280 2.7 GHz.
568         - RAM Memory: 12* 16GB DDR4-2933.
569         - Disks: 2* 1.92TB SATA SSD.
570     - NICs configuration:
571         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
572             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
573             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
574             - PCIe Slot9 5e:00.xx: empty.
575         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
576             - PCIe Slot6 86:00.xx: empty.
577             - PCIe Slot8 af:00.xx: empty.
578             - PCIe Slot10 d8:00.xx: empty.
579 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
580     - Quantity: 3
581     - Physical connectivity:
582         - IPMI and host management ports.
583         - NIC ports connected into 2-node testbed topologies.
584     - Main HW configuration:
585         - Chassis: SuperMicro SYS-7049GP-TRT.
586         - Motherboard: SuperMicro X11DPG-QT.
587         - Processors: 2* Intel Gold 6252N 2.3 GHz.
588         - RAM Memory: 12* 16GB DDR4-2933.
589         - Disks: 2* 1.92TB SATA SSD.
590     - NICs configuration:
591         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
592             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
593             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
594             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
595         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
596             - PCIe Slot6 86:00.xx: empty.
597             - PCIe Slot8 af:00.xx: empty.
598             - PCIe Slot10 d8:00.xx: empty.
599 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
600     - Quantity: 3.
601     - Physical connectivity:
602         - IPMI and host management ports.
603         - NIC ports connected into 2-node testbed topologies.
604     - Main HW configuration:
605         - Chassis: SuperMicro SYS-7049GP-TRT.
606         - Motherboard: SuperMicro X11DPG-QT.
607         - Processors: 2* Intel Platinum 8280 2.7 GHz.
608         - RAM Memory: 12* 16GB DDR4-2933.
609         - Disks: 2* 1.92TB SATA SSD.
610     - NICs configuration:
611         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
612             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
613             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
614             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
615         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
616             - PCIe Slot6 86:00.xx: empty.
617             - PCIe Slot8 af:00.xx: empty.
618             - PCIe Slot10 d8:00.xx: empty.
619 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
620     - Quantity: 3.
621     - Physical connectivity:
622         - CIMC and host management ports.
623         - no NIC ports, standalone setup.
624     - Main HW configuration:
625         - Chassis: SuperMicro 1029P-WTRT.
626         - Motherboard: SuperMicro X11DDW-NT.
627         - Processors: 2* Intel Platinum 8280 2.7 GHz.
628         - RAM Memory: 12* 16GB DDR4-2933.
629         - Disks: 4* 1.92TB SATA SSD.
630     - NICs configuration:
631         - Numa0:
632             - no cards.
633         - Numa1:
634             - no cards.
635 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
636     - Quantity: 1.
637     - Physical connectivity:
638         - IPMI and host management ports.
639         - NIC ports connected into 2-node testbed topologies.
640     - Main HW configuration:
641         - Chassis: SuperMicro AS-1114S-WTRT
642         - Processors: 1* AMD EPYC 7532 2.4 GHz.
643         - RAM Memory: 8* 32GB DDR4-2933.
644         - Disks: 1* 1TB SATA SSD.
645     - NICs configuration:
646         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
647             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
648             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
649             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
650 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
651     - Quantity: 1.
652     - Physical connectivity:
653         - IPMI and host management ports.
654         - NIC ports connected into 2-node testbed topologies.
655     - Main HW configuration:
656         - Chassis: SuperMicro AS-1114S-WTRT
657         - Processors: 1* AMD EPYC 7532 2.4 GHz.
658         - RAM Memory: 8* 32GB DDR4-2933.
659         - Disks: 1* 1TB SATA SSD.
660     - NICs configuration:
661         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
662             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
663             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
664             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
665 17.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
666     - Quantity: 2
667     - Physical connectivity:
668         - IPMI and host management ports.
669         - NIC ports connected into 1-node topologies.
670     - Main HW configuration:
671         - Chassis: GIGABYTE Rack Mount
672         - Motherboard: MT91-FS4-00
673         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
674         - RAM Memory: 16 * 16GB DIMM
675         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
676     - NICs configuration:
677         - Numa0:
678             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
679             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
680         - Numa1:
681             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
682             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
683 18.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
684     - Quantity: 2
685     - Physical connectivity:
686         - IPMI(?) and host management ports.
687         - NIC ports connected into 3-node topology.
688     - Main HW configuration:
689         - Chassis: Huawei TaiShan 2280.
690         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
691         - RAM Memory: 8* 16GB DDR4-2400MT/s
692         - Disks: 1* 4TB SATA HDD
693     - NICs configuration:
694         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
695         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
696 19.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
697     - Quantity: 1
698     - Physical connectivity:
699         - IPMI and host management ports.
700         - NIC ports connected into 2-node topologies.
701     - Main HW configuration:
702         - Chassis: Gigabyte R181-T90 1U
703         - Motherboard: MT91-FS1
704         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
705         - RAM Memory: 4* 32GB RDIMM
706         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
707     - NICs configuration:
708         - Numa0:
709             - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
710         - Numa1:
711             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
712 20.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
713     - Quantity: 1
714     - Physical connectivity:
715         - IPMI and host management ports.
716         - NIC ports connected into 2-node and 3-node topologies.
717     - Main HW configuration:
718         - Chassis: SuperMicro SYS-7049GP-TRT.
719         - Motherboard: SuperMicro X11DPG-QT.
720         - Processors: 2* Intel Platinum 8180 2.5 GHz.
721         - RAM Memory: 16* 16GB DDR4-2666MHz.
722         - Disks: 2* 1.6TB 6G SATA SSD.
723     - NICs configuration:
724         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
725             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
726             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
727             - PCIe Slot9 5e:00.xx: empty.
728         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
729             - PCIe Slot6 86:00.xx: empty.
730             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
731             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
732 ```
733
734 ### Naming Convention
735
736 Following naming convention is used within this page to specify physical
737 connectivity and wiring across defined CSIT testbeds:
738
739 ```
740 - testbedname: testbedN.
741 - hostname:
742     - traffic-generator: tN-tgW.
743     - system-under-testX: tN-sutX.
744 - portnames:
745     - tN-tgW-cY/pZ.
746     - tN-sutX-cY/pZ.
747 - where:
748     - N - testbed number.
749     - tgW - server acts as traffic-generator with W index.
750     - sutX - server acts as system-under-test with X index.
751     - Y - PCIe slot number denoting a NIC card number within the host.
752     - Z - port number on the NIC card.
753 ```
754
755 ## Testbeds Configuration
756
757 ### Per Testbed Server Allocation and Naming
758
759 #### 1-Node-Skylake Servers (1n-skx) PROD
760
761 ```
762 - SUT [Server-Type-B6]:
763     - testbedname: testbed11.
764     - hostname: s1-t11-sut1.
765     - IPMI IP: 10.30.50.47
766     - Host IP: 10.30.51.50
767     - portnames:
768         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
769         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
770         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
771         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
772         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
773         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
774         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
775         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
776 - SUT [Server-Type-B6]:
777     - testbedname: testbed12.
778     - hostname: s2-t12-sut1.
779     - IPMI IP: 10.30.50.48
780     - Host IP: 10.30.51.51
781     - portnames:
782         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
783         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
784         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
785         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
786         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
787         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
788         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
789         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
790 ```
791
792 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
793
794 ```
795 - SUT [Server-Type-E11]:
796     - testbedname: testbed13
797     - hostname: s55-t13-sut1
798     - IPMI IP: 10.30.50.70
799     - Host IP: 10.30.51.70
800     - portnames:
801         - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
802         - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
803         - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
804         - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
805         - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
806         - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
807         - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
808         - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
809 - SUT [Server-Type-E11]:
810     - testbedname: testbed14
811     - hostname: s56-t14-sut1
812     - IPMI IP: 10.30.50.71
813     - Host IP: 10.30.51.71
814     - portnames:
815         - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
816         - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
817         - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
818         - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
819         - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
820         - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
821         - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
822         - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
823 ```
824
825 #### 1-Node-Cascadelake Servers (1n-clx) PROD
826
827 ```
828 - SUT [Server-Type-C1]:
829     - testbedname: testbed11.
830     - hostname: s32-t14-sut1.
831     - IPMI IP: 10.30.55.17
832     - Host IP: 10.32.8.17
833     - portnames:
834         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
835         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
836         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
837         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
838         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
839         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
840         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
841         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
842 ```
843
844 #### 2-Node-Skylake Servers (2n-skx) PROD
845
846 ```
847 - SUT [Server-Type-B1]:
848     - testbedname: testbed21.
849     - hostname: s3-t21-sut1.
850     - IPMI IP: 10.30.50.41
851     - Host IP: 10.30.51.44
852     - portnames:
853         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
854         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
855         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
856         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
857         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
858         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
859 - TG [Server-Type-B2]:
860     - testbedname: testbed21.
861     - hostname: s4-t21-tg1.
862     - IPMI IP: 10.30.50.42
863     - Host IP: 10.30.51.45
864     - portnames:
865         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
866         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
867         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
868         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
869         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
870         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
871 - SUT [Server-Type-B1]:
872     - testbedname: testbed22.
873     - hostname: s5-t22-sut1.
874     - IPMI IP: 10.30.50.49
875     - Host IP: 10.30.51.52
876     - portnames:
877         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
878         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
879         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
880         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
881         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
882         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
883 - TG [Server-Type-B2]:
884     - testbedname: testbed22.
885     - hostname: s6-t22-tg1.
886     - IPMI IP: 10.30.50.50
887     - Host IP: 10.30.51.53
888     - portnames:
889         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
890         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
891         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
892         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
893         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
894         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
895 - SUT [Server-Type-B1]:
896     - testbedname: testbed23.
897     - hostname: s7-t23-sut1.
898     - IPMI IP: 10.30.50.51
899     - Host IP: 10.30.51.54
900     - portnames:
901         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
902         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
903         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
904         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
905         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
906         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
907 - TG [Server-Type-B2]:
908     - testbedname: testbed23.
909     - hostname: s8-t23-tg1.
910     - IPMI IP: 10.30.50.52
911     - Host IP: 10.30.51.55
912     - portnames:
913         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
914         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
915         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
916         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
917         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
918         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
919 - SUT [Server-Type-B1]:
920     - testbedname: testbed24.
921     - hostname: s9-t24-sut1.
922     - IPMI IP: 10.30.50.53
923     - Host IP: 10.30.51.56
924     - portnames:
925         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
926         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
927         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
928         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
929         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
930         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
931 - TG [Server-Type-B2]:
932     - testbedname: testbed24.
933     - hostname: s10-t24-tg1.
934     - IPMI IP: 10.30.50.54
935     - Host IP: 10.30.51.57
936     - portnames:
937         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
938         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
939         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
940         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
941         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
942         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
943 ```
944
945 #### 2-Node-Denverton Servers (2n-dnv) PROD
946
947 Note: ServerB28 (TG) is shared between testbed26 & testbed35
948
949 ```
950 - TG [Server-Type-B2]:
951     - testbednames: testbed26 and testbed35.
952     - hostname: s28-t26t35-tg1.
953     - IPMI IP: 10.30.55.10
954     - Host IP: 10.32.8.10
955     - portnames:
956         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
957         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
958         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
959         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
960         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
961         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
962         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
963         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
964         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
965         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
966         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
967         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
968 - SUT [Server-Type-B10]:
969     - testbednames: testbed26.
970     - hostname: s29-t26-sut1.
971     - IPMI IP: 10.30.55.11
972     - Host IP: 10.32.8.11
973     - portnames:
974         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
975         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
976         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
977         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
978 ```
979
980 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
981
982 ```
983 - SUT [Server-Type-B8]:
984     - testbedname: testbed25.
985     - hostname: s25-t25-sut1.
986     - IPMI IP: 10.30.50.58
987     - Host IP: 10.30.51.61
988     - portnames:
989         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
990         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
991         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
992         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
993 - TG [Server-Type-B7]:
994     - testbedname: testbed25.
995     - hostname: s26-t25-tg1.
996     - IPMI IP: 10.30.50.59
997     - Host IP: 10.30.51.62
998     - portnames:
999         - s26-t25-tg1-p1 - 10GE-port1.
1000         - s26-t25-tg1-p2 - 10GE-port2.
1001         - s26-t25-tg1-p3 - 10GE-port3.
1002         - s26-t25-tg1-p4 - 10GE-port4.
1003 ```
1004
1005 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1006
1007 ```
1008 - SUT [Server-Type-C2]:
1009     - testbedname: testbed27.
1010     - hostname: s33-t27-sut1.
1011     - IPMI IP: 10.30.55.18
1012     - Host IP: 10.32.8.18
1013     - portnames:
1014         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1015         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1016         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1017         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1018         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1019         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1020         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1021         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1022         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1023         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1024 - TG [Server-Type-C3]:
1025     - testbedname: testbed27.
1026     - hostname: s34-t27-tg1.
1027     - IPMI IP: 10.30.55.19
1028     - Host IP: 10.32.8.19
1029     - portnames:
1030         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1031         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1032         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1033         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1034         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1035         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1036         - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1037         - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1038         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1039         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1040 - SUT [Server-Type-C2]:
1041     - testbedname: testbed28.
1042     - hostname: s35-t28-sut1.
1043     - IPMI IP: 10.30.55.20
1044     - Host IP: 10.32.8.20
1045     - portnames:
1046         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1047         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1048         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1049         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1050         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1051         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1052         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1053         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1054         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1055         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1056 - TG [Server-Type-C3]:
1057     - testbedname: testbed28.
1058     - hostname: s36-t28-tg1.
1059     - IPMI IP: 10.30.55.21
1060     - Host IP: 10.32.8.21
1061     - portnames:
1062         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1063         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1064         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1065         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1066         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1067         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1068         - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1069         - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1070         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1071         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1072 - SUT [Server-Type-C2]:
1073     - testbedname: testbed29.
1074     - hostname: s37-t29-sut1.
1075     - IPMI IP: 10.30.55.22
1076     - Host IP: 10.32.8.22
1077     - portnames:
1078         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1079         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1080         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1081         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1082         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1083         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1084         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1085         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1086         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1087         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1088 - TG [Server-Type-C3]:
1089     - testbedname: testbed29.
1090     - hostname: s38-t29-tg1.
1091     - IPMI IP: 10.30.55.23
1092     - Host IP: 10.32.8.23
1093     - portnames:
1094         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1095         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1096         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1097         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1098         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1099         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1100         - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1101         - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1102         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1103         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1104 ```
1105
1106 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1107
1108 ```
1109 - SUT [Server-Type-D1]:
1110     - testbedname: testbed210.
1111     - hostname: s60-t210-sut1.
1112     - IPMI IP: 10.30.55.24
1113     - Host IP: 10.32.8.24
1114     - portnames:
1115         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1116         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1117         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1118         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1119         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1120         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1121         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1122         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1123 - TG [Server-Type-D2]:
1124     - testbedname: testbed210.
1125     - hostname: s61-t210-tg1.
1126     - IPMI IP: 10.30.55.25
1127     - Host IP: 10.32.8.25
1128     - portnames:
1129         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1130         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1131         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1132         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1133         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1134         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1135         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1136         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1137 ```
1138
1139 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1140
1141 Note: Server19 (TG) is shared between testbed33 & testbed211
1142
1143 ```
1144 - SUT [Server-Type-E22]:
1145     - testbedname: testbed211.
1146     - hostname: s27-t211-sut1.
1147     - IPMI IP: 10.30.50.69
1148     - Host IP: 10.30.51.69
1149     - portnames:
1150         - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1151         - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1152         - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1153         - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1154 - TG [Server-Type-E31]:
1155     - testbedname: testbed33 and testbed211.
1156     - hostname: s19-t33t211-tg1.
1157     - IPMI IP: 10.30.50.46
1158     - Host IP: 10.30.51.49
1159     - portnames:
1160         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1161         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1162         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1163         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1164         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1165         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1166         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1167         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1168         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1169         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1170         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1171         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1172 ```
1173
1174 #### 3-Node-Skylake Servers (3n-skx) PROD
1175
1176 ```
1177 - ServerB11 [Server-Type-B1]:
1178     - testbedname: testbed31.
1179     - hostname: s11-t31-sut1.
1180     - IPMI IP: 10.30.50.43
1181     - Host IP: 10.30.51.46
1182     - portnames:
1183         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1184         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1185         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1186         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1187         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1188         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1189         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1190         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1191 - ServerB12 [Server-Type-B1]:
1192     - testbedname: testbed31.
1193     - hostname: s12-t31-sut2.
1194     - IPMI IP: 10.30.50.44
1195     - Host IP: 10.30.51.47
1196     - portnames:
1197         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1198         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1199         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1200         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1201         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1202         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1203         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1204         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1205 - ServerB13 [Server-Type-B2]:
1206     - testbedname: testbed31.
1207     - hostname: s13-t31-tg1.
1208     - IPMI IP: 10.30.50.45
1209     - Host IP: 10.30.51.48
1210     - portnames:
1211         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1212         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1213         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1214         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1215         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1216         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1217         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1218         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1219 - ServerB14 [Server-Type-B1]:
1220     - testbedname: testbed32.
1221     - hostname: s14-t32-sut1.
1222     - IPMI IP: 10.30.50.55
1223     - Host IP: 10.30.51.58
1224     - portnames:
1225         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1226         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1227         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1228         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1229         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1230         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1231         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1232         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1233 - ServerB15 [Server-Type-B1]:
1234     - testbedname: testbed32.
1235     - hostname: s15-t32-sut2.
1236     - IPMI IP: 10.30.50.56
1237     - Host IP: 10.30.51.59
1238     - portnames:
1239         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1240         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1241         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1242         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1243         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1244         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1245         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1246         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1247 - ServerB16 [Server-Type-B2]:
1248     - testbedname: testbed32.
1249     - hostname: s16-t32-tg1.
1250     - IPMI IP: 10.30.50.57
1251     - Host IP: 10.30.51.60
1252     - portnames:
1253         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1254         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1255         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1256         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1257         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1258         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1259         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1260         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1261 ```
1262
1263 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1264
1265 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1266
1267 ```
1268 - ServerB22 [Server-Type-B5]:
1269     - testbedname: testbed35.
1270     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1271     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1272     - Host IP: 10.30.51.9
1273     - portnames:
1274         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1275         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1276     - 1GB ports (tbd)
1277 - ServerB23 [Server-Type-B5]:
1278     - testbedname: testbed35.
1279     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1280     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1281     - Host IP: 10.30.51.10
1282     - portnames:
1283         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1284         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1285     - 1GB ports (tbd)
1286 - ServerB24 [Server-Type-B5]:
1287     - testbedname: testbed35.
1288     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1289     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1290     - Host IP: 10.30.51.11
1291     - portnames:
1292         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1293         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1294     - 1GB ports (tbd)
1295 ```
1296
1297 #### 3-Node-Taishan Servers (3n-tsh) PROD
1298
1299 Note: Server19 (TG) is shared between testbed33 & testbed211
1300
1301 ```
1302 - SUT [Server-Type-E21]:
1303     - testbedname: testbed33.
1304     - hostname: s17-t33-sut1.
1305     - IPMI IP: 10.30.50.36
1306     - Host IP: 10.30.51.36
1307     - portnames:
1308         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1309         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1310         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1311         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1312 - SUT [Server-Type-E21]:
1313     - testbedname: testbed33.
1314     - hostname: s18-t33-sut2.
1315     - IPMI IP: 10.30.50.37
1316     - Host IP: 10.30.51.37
1317     - portnames:
1318         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1319         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1320         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1321         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1322 - TG [Server-Type-E31]:
1323     - testbedname: testbed33 and testbed211.
1324     - hostname: s19-t33t211-tg1.
1325     - IPMI IP: 10.30.50.46
1326     - Host IP: 10.30.51.49
1327     - portnames:
1328         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1329         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1330         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1331         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1332         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1333         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1334         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1335         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1336         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1337         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1338         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1339         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1340 ```
1341
1342 #### 3-Node-Denverton Servers (3n-dnv) PROD
1343
1344 ```
1345 - ServerB30 [Server-Type-B10]:
1346     - testbednames: testbed35.
1347     - hostname: s30-t35-sut1.
1348     - IPMI IP: 10.30.55.12
1349     - Host IP: 10.32.8.12
1350     - portnames:
1351         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1352         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1353         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1354         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1355 - ServerB31 [Server-Type-B10]:
1356     - testbednames: testbed35.
1357     - hostname: s31-t35-sut2.
1358     - IPMI IP: 10.30.55.13
1359     - Host IP: 10.32.8.13
1360     - portnames:
1361         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1362         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1363         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1364         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1365 ```
1366
1367 ### Per Testbed Wiring
1368
1369 #### 1-Node-Skylake Wiring (1n-skx) PROD
1370
1371 ```
1372 - testbed11:
1373     - ring1 10GE-ports x710-4p10GE:
1374         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1375     - ring2 10GE-ports x710-4p10GE:
1376         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1377     - ring3 10GE-ports x710-4p10GE:
1378         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1379     - ring4 10GE-ports x710-4p10GE:
1380         - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1381     - ring5 100GE-ports e810-2p100GE:
1382         - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1383     - ring6 100GE-ports e810-2p100GE:
1384         - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1385 - testbed12:
1386     - ring1 10GE-ports x710-4p10GE:
1387         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1388     - ring2 10GE-ports x710-4p10GE:
1389         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1390     - ring3 10GE-ports x710-4p10GE:
1391         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1392     - ring4 10GE-ports x710-4p10GE:
1393         - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1394     - ring5 100GE-ports e810-2p100GE:
1395         - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1396     - ring6 100GE-ports e810-2p100GE:
1397         - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1398 ```
1399
1400 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1401
1402 ```
1403 - testbed13:
1404     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1405         - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1406     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1407         - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1408     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1409         - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1410     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1411         - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1412
1413 - testbed14:
1414     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1415         - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1416     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1417         - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1418     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1419         - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1420     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1421         - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1422 ```
1423
1424 #### 1-Node-Cascadelake Wiring (1n-clx) PROD
1425
1426 ```
1427 - testbed14:
1428     - ring1 10GE-ports x710-4p10GE:
1429         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1430     - ring2 10GE-ports x710-4p10GE:
1431         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1432     - ring3 10GE-ports x710-4p10GE:
1433         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1434     - ring4 10GE-ports x710-4p10GE:
1435         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1436 ```
1437
1438 #### 2-Node-Skylake Wiring (2n-skx) PROD
1439
1440 ```
1441 - testbed21:
1442     - ring1 10GE-ports x710-4p10GE on SUT:
1443         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1444         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1445     - ring2 10GE-ports x710-4p10GE on SUT:
1446         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1447         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1448     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1449         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1450         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1451 - testbed22:
1452     - ring1 10GE-ports x710-4p10GE on SUT:
1453         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1454         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1455     - ring2 10GE-ports x710-4p10GE on SUT:
1456         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1457         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1458     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1459         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1460         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1461 - testbed23:
1462     - ring1 10GE-ports x710-4p10GE on SUT:
1463         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1464         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1465     - ring2 10GE-ports x710-4p10GE on SUT:
1466         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1467         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1468     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1469         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1470         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1471 - testbed24:
1472     - ring1 10GE-ports x710-4p10GE on SUT:
1473         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1474         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1475     - ring2 10GE-ports x710-4p10GE on SUT:
1476         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1477         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1478     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1479         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1480         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1481 ```
1482
1483 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1484
1485 ```
1486 - testbed26:
1487     - ring1 10GE-ports x553 copper port on SUT:
1488         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1489         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1490     - ring2 10GE-ports x553 fiber port on SUT:
1491         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1492         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1493 ```
1494
1495 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1496
1497 ```
1498 - testbed25:
1499     - link1 10GE-port x710-4p10GE on SUT:
1500         - t25-tg1-p1 to t25-sut1-c2/p1.
1501     - link2 10GE-port x710-4p10GE on SUT:
1502         - t25-tg1-p2 to t25-sut1-c2/p2.
1503     - link3 10GE-port x710-4p10GE on SUT:
1504         - t25-tg1-p3 to t25-sut1-c2/p3.
1505     - link4 10GE-port x710-4p10GE on SUT:
1506         - t25-tg1-p4 to t25-sut1-c2/p4.
1507 ```
1508
1509 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1510
1511 ```
1512 - testbed27:
1513     - ring1 10GE-ports x710-4p10GE on SUT:
1514         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1515         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1516     - ring2 10GE-ports x710-4p10GE on SUT:
1517         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1518         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1519     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1520         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1521         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1522     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1523         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1524         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1525     - ring5 100GE-ports e810-2p100GE on SUT:
1526         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1527         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1528 - testbed28:
1529     - ring1 10GE-ports x710-4p10GE on SUT:
1530         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1531         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1532     - ring2 10GE-ports x710-4p10GE on SUT:
1533         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1534         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1535     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1536         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1537         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1538     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1539         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1540         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1541     - ring5 100GE-ports e810-2p100GE on SUT:
1542         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1543         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1544 - testbed29:
1545     - ring1 10GE-ports x710-4p10GE on SUT:
1546         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1547         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1548     - ring2 10GE-ports x710-4p10GE on SUT:
1549         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1550         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1551     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1552         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1553         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1554     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1555         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1556         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1557     - ring6 100GE-ports e810-2p100GE on SUT:
1558         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1559         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1560 ```
1561
1562 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1563
1564 ```
1565 - testbed210:
1566     - ring1 10GE-ports x710-4p10GE on SUT:
1567         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1568         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1569     - ring2 10GE-ports x710-4p10GE on SUT:
1570         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1571         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1572     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1573         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1574         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1575     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1576         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1577         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1578 ```
1579
1580 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1581
1582 ```
1583 - testbed211:
1584     - ring1 10GE-ports x520-2p10GE on SUTs:
1585         - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1586         - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1587 ```
1588
1589 #### 3-Node-Skylake Wiring (3n-skx) PROD
1590
1591 ```
1592 - testbed31:
1593     - ring1 10GE-ports x710-4p10GE on SUTs:
1594         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1595         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1596         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1597     - ring2 10GE-ports x710-4p10GE on SUT:
1598         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1599         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1600         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1601     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1602         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1603         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1604         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1605     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1606         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1607         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1608         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1609     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1610         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1611         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1612 - testbed32:
1613     - ring1 10GE-ports x710-4p10GE on SUTs:
1614         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1615         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1616         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1617     - ring2 10GE-ports x710-4p10GE on SUT:
1618         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1619         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1620         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1621     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1622         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1623         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1624         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1625     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1626         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1627         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1628         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1629     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1630         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1631         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1632 ```
1633
1634 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1635
1636 ```
1637 To be completed.
1638 ```
1639
1640 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1641
1642 ```
1643 - testbed33:
1644     - ring1 10GE-ports x520-2p10GE on SUTs:
1645         - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1646         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1647         - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1648     - ring2 25GE-ports cx4-2p25GE on SUTs:
1649         - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1650         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1651         - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1652 ```
1653
1654 #### 3-Node-Denverton Wiring (3n-dnv) PROD
1655
1656 ```
1657 - testbed35:
1658     - ring1 10GE-ports x553 copper port on SUTs:
1659         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1660         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1661         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1662     - ring2 10GE-ports x553 fiber port on SUTs:
1663         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1664         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1665         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1666 ```
1667
1668 ## Inventory
1669
1670 ### Appliances
1671
1672 ```
1673 1. Ixia PerfectStorm One Appliance
1674     - 1 * PS10GE4NG
1675         - Chassis: PS10GE4NG.
1676         - Motherboard: SuperMicro X11DPG-QT.
1677         - Processors: Quad-Core, Intel Processor.
1678         - HW accelerators: FPGA offload.
1679         - RAM Memory: 64GB.
1680         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1681         - Physical Interfaces: 4 * 10GE SFP+.
1682         - Operating System: Native IxOS.
1683 ```
1684
1685 ### Arm Servers
1686
1687 ```
1688 1. Arm Cortex A-72 servers
1689     - 2 * ThunderX2 (VPP Device)
1690         - Chassis: GIGABYTE Rack Mount
1691         - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1692         - RAM Memory: 16* 16GB DIMM
1693         - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1694     - 1 * ThunderX2 (Performance)
1695         - Chassis: GIGABYTE Rack Mount
1696         - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1697         - RAM Memory: 4* 32GB RDIMM
1698         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1699     - 2 * Huawei TaiShan 2280.
1700         - Chassis: Huawei TaiShan 2280.
1701         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1702         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1703         - Disks: 1* 4TB SATA HDD.
1704 ```
1705
1706 ### Xeon and Atom Servers
1707
1708 ```
1709 1. Intel Xeon servers:
1710     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1711         - Chassis: SuperMicro SYS-7049GP-TRT.
1712         - Motherboard: SuperMicro X11DPG-QT.
1713         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1714         - RAM Memory: 16* 16GB DDR4-2666MHz.
1715         - Disks: 2* 1.6TB 6G SATA SSD.
1716 2. Intel Atom servers with Rangely processors.
1717     - 3 * Netgate XG-2758-1u
1718         - Chassis: Netgate XG-2758-1u
1719         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1720         - RAM Memory: 16GB ECC
1721         - Disks: 150 GB
1722 ```
1723
1724 ### Network Interface Cards
1725
1726 ```
1727 1. 10GE NICs
1728     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1729     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1730     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1731 2. 25GE NICs
1732     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1733 3. 40GE NICs
1734     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1735 4. 100GE NICs
1736     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1737 ```
1738
1739 ### Pluggables and Cables
1740
1741 Pluggables:
1742
1743 ```
1744 1. 10GE SFP+
1745     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1746     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1747 2. 25GE SFP28
1748     - None
1749 3. 40GE QSFP+
1750     - None
1751 4. 100GE
1752     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1753 ```
1754
1755 Standalone cables:
1756
1757 ```
1758 1. 10GE
1759     - None
1760 2. 25GE
1761     - None
1762 3. 40GE QSFP+
1763     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1764 4. 100GE
1765     - None
1766 ```
1767
1768 ### Other Parts