doc update
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
15    1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
16    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
19    1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
20    1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
21 1. [Server Management](#server-management)
22    1. [Requirements](#requirements)
23    1. [Addressing](#addressing)
24    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
25    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
26 1. [Server Specifications](#server-specifications)
27    1. [Server Types](#server-types)
28    1. [Naming Convention](#naming-convention)
29 1. [Testbeds Configuration](#testbeds-configuration)
30    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
31       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
32       1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
33       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
34       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
35       1. [2-Node-Denverton Servers (2n-dnv) PROD](#2-node-denverton-servers-2n-dnv-prod)
36       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
37       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
38       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
39       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
40       1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd)
41       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
42       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
43       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
44       1. [3-Node-Altra Servers (3n-alt) TBD](#3-node-altra-servers-3n-alt-tbd)
45       1. [3-Node-Icelake Servers (3n-icx) TBD](#3-node-icelake-servers-3n-icx-tbd)
46    1. [Per Testbed Wiring](#per-testbed-wiring)
47       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
48       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
49       1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
50       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
51       1. [2-Node-Denverton Wiring (2n-dnv) PROD](#2-node-denverton-wiring-2n-dnv-prod)
52       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
53       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
54       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
55       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
56       1. [2-Node-Icelake Servers (2n-icx) TBD](#2-node-icelake-servers-2n-icx-tbd)
57       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
58       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
59       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
60       1. [3-Node-Altra Wiring (3n-alt) TBD](#3-node-altra-wiring-3n-alt-tbd)
61       1. [3-Node-Icelake Wiring (3n-icx) TBD](#3-node-icelake-wiring-3n-icx-tbd)
62 1. [Inventory](#inventory)
63    1. [Appliances](#appliances)
64    1. [Arm Servers](#arm-servers)
65    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
66    1. [Network Interface Cards](#network-interface-cards)
67    1. [Pluggables and Cables](#pluggables-and-cables)
68    1. [Other Parts](#other-parts)
69
70 ## Purpose
71
72 This note includes specification of the physical testbed infrastructure
73 hosted by LFN FD.io CSIT project.
74
75 ## Testbeds Overview
76
77 ### Summary List
78
79 ```
80  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx
81  1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0
82  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0
83  3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0
84  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0    0
85  5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0    0    0
86  6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0    0
87  7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0
88  8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0    0
89  9. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0    0
90 10. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    0    8
91 11. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0
92 12. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0
93 13. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0    0
94 14. 3-Node-Altra       perf   alt   icx   1    2    .5   0    0    0    0    0    0    0    2    0    0    .5
95 15. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0    0
96 16. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2    0
97 17. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    6    0    6
98 18. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    0    0    2    0    0    0
99                                  Totals: 34   43  21.5   4   19    1    2    3    3    2    4    7    2  14.5
100 ```
101
102 ### 1-Node-Skylake Xeon Intel (1n-skx)
103
104 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
105 ports connected back-to-back ([Server Types](#server-types)).
106 Used for FD.io VPP_Device functional driver tests.
107
108 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
109
110 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
111 ports connected back-to-back ([Server Types](#server-types)).
112 Used for FD.io VPP_Device functional driver tests.
113
114 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
115
116 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
117 NIC ports connected back-to-back ([Server Types](#server-types)).
118
119 Used for FD.io VPP_Device functional driver tests.
120
121 ### 2-Node-Skylake Xeon Intel (2n-skx)
122
123 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
124 (Server-Type-B2) connected in a 2-node circular topology
125 ([Server Types](#server-types)).
126 Used for FD.io performance tests.
127
128 ### 2-Node-Denverton Atom Intel (2n-dnv)
129
130 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
131 TG (Server-Type-B2) connected in a 2-node circular topology
132 ([Server Types](#server-types)).
133 Used for FD.io performance tests.
134
135 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
136
137 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
138 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
139 circular topology ([Server Types](#server-types)).
140 Used for FD.io TCP/IP and HTTP performance tests.
141
142 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
143
144 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
145 one TG (Server-Type-C3) connected in a 2-node circular topology
146 ([Server Types](#server-types)).
147 Used for FD.io performance tests.
148
149 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
150
151 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
152 one TG (Server-Type-D2) connected in a 2-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
155
156 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
157
158 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
159 one TG (Server-Type-E31) connected in a 2-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
162
163 ### 2-Node-Icelake Xeon Intel (2n-icx)
164
165 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
166 one TG (Server-Type-F2) connected in a 2-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
169
170 ### 3-Node-Haswell Xeon Intel (3n-hsw)
171
172 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
173 TG (Server-Type-A2) connected in a 3-node circular topology
174 ([Server Types](#server-types)).
175 Used for FD.io performance tests.
176
177 ### 3-Node-Skylake Xeon Intel (3n-skx)
178
179 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
180 TG (Server-Type-B2) connected in a 3-node circular topology.
181 Used for FD.io performance tests.
182
183 ### 3-Node-Rangeley Atom Testbeds
184
185 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
186 TG (Server-Type-2) connected in a 3-node circular topology
187 ([Server Types](#server-types)).
188 Used for FD.io performance tests.
189
190 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
191
192 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
193 TG (Server-Type-E31) connected in a 3-node circular topology
194 ([Server Types](#server-types)).
195 Used for FD.io performance tests.
196
197 ### 3-Node-Altra Arm Ampere (3n-alt)
198
199 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
200 TG (Server-Type-F4) connected in a 3-node circular topology
201 ([Server Types](#server-types)).
202 Used for FD.io performance tests.
203
204 ### 3-Node-Icelake Xeon Intel (3n-icx)
205
206 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
207 TG (Server-Type-F3) connected in a 3-node circular topology
208 ([Server Types](#server-types)).
209 Used for FD.io performance tests.
210
211 ## Server Management
212
213 ### Requirements
214
215 For management purposes, each server must have following two ports
216 connected to the management network:
217
218 ```
219 - 1GE IPMI port
220   - IPMI - Intelligent Platform Management Interface.
221   - Required for access to embedded server management with WebUI, CLI,
222     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
223 - 1GE/10GE/40GE management port
224   - hostOS management port for general system management.
225 ```
226
227 ### Addressing
228
229 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
230 Management port, which are connected to two different VLANs.
231
232 ```
233 1. LOM (IPMI) VLAN:
234     - Subnet: 10.30.50.0/24
235     - Gateway: 10.30.50.1
236     - Broadcast: 10.30.50.255
237     - DNS1: 199.204.44.24
238     - DNS2: 199.204.47.54
239 2. Management Vlan:
240     - Subnet: 10.30.51.0/24
241     - Gateway: 10.30.51.1
242     - Broadcast: 10.30.51.255
243     - DNS1: 199.204.44.24
244     - DNS2: 199.204.47.54
245 ```
246
247 To access these hosts, VPN connection is required.
248
249 ### LOM (IPMI) VLAN IP Addresses
250
251 Name         | Comment
252 ------------ | -------
253 10.30.50.0   | network
254 10.30.51.1   | Router
255 10.30.50.2   | LF Reserved
256 10.30.50.3   | LF Reserved
257 10.30.50.4   | LF Reserved
258 10.30.50.5   | LF Reserved
259 10.30.50.6   | LF Reserved
260 10.30.50.7   | LF Reserved
261 10.30.50.8   | LF Reserved
262 10.30.50.9   | LF Reserved
263 10.30.50.10  | LF Reserved
264 10.30.50.11  | LF Reserved
265 10.30.50.12  | LF Reserved
266 10.30.50.13  | LF Reserved
267 10.30.50.14  | LF Reserved
268 10.30.50.15  | LF Reserved
269 10.30.50.22  | s42-nomad
270 10.30.50.24  | s43-nomad
271 10.30.50.25  | s44-nomad
272 10.30.50.26  | s45-nomad
273 10.30.50.28  | s41-nomad
274 10.30.50.29  | s39-nomad
275 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
276 10.30.50.30  | s40-nomad
277 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
278 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
279 10.30.50.36  | s17-t33-sut1
280 10.30.50.37  | s18-t33-sut2
281 10.30.50.38  | fdio-marvell-dev
282 10.30.50.39  | s53-nomad
283 10.30.50.40  | s54-nomad
284 10.30.50.41  | s3-t21-sut1
285 10.30.50.42  | s4-t21-tg1
286 10.30.50.43  | s11-t31-sut1
287 10.30.50.44  | s12-t31-sut2
288 10.30.50.45  | s13-t31-tg1
289 10.30.50.46  | s19-t33t211-tg1
290 10.30.50.47  | s1-t11-sut1
291 10.30.50.48  | s2-t12-sut1
292 10.30.50.49  | s5-t22-sut1
293 10.30.50.50  | s6-t22-tg1
294 10.30.50.51  | s7-t23-sut1
295 10.30.50.52  | s8-t23-tg1
296 10.30.50.53  | s9-t24-sut1
297 10.30.50.54  | s10-t24-tg1
298 10.30.50.55  | s14-t32-sut1
299 10.30.50.56  | s15-t32-sut2
300 10.30.50.57  | s16-t32-tg1
301 10.30.50.58  | s25-t25-sut1
302 10.30.50.59  | s26-t25-tg1
303 10.30.50.65  | s52-nomad
304 10.30.50.66  | s51-nomad
305 10.30.50.67  | s49-nomad
306 10.30.50.68  | s50-nomad
307 10.30.50.69  | s27-t211-sut1
308 10.30.50.70  | s55-t13-sut1
309 10.30.50.71  | s56-t14-sut1
310 10.30.50.72  | s62-t34-sut1
311 10.30.50.73  | s63-t34-sut2
312 10.30.50.74  | s64-t34t36-tg1
313 10.30.50.75  | s65-t37-sut1
314 10.30.50.76  | s66-t37-sut2
315 10.30.50.77  | s67-t37-tg1
316 10.30.50.78  | s68-t38-sut1
317 10.30.50.79  | s69-t38-sut2
318 10.30.50.80  | s70-t38-tg1
319 10.30.50.81  | s71-t212-sut1
320 10.30.50.82  | s72-t212-tg1
321 10.30.50.83  | s73-t213-sut1
322 10.30.50.84  | s74-t213-tg1
323 10.30.50.85  | s75-t214-sut1
324 10.30.50.86  | s76-t214-tg1
325 10.30.50.87  | s77-t215-sut1
326 10.30.50.88  | s78-t215-tg1
327 10.30.50.89  | s79-t39t310-tg1
328 10.30.50.90  | s80-t311t312-tg1
329 10.30.50.91  | s58-nomad
330 10.30.50.92  | s59-nomad
331 10.30.50.255 | Broadcast
332 10.30.55.0   | network
333 10.30.55.1   | Router
334 10.30.55.10  | s28-t26t35-tg1
335 10.30.55.11  | s29-t26-sut1
336 10.30.55.12  | s30-t35-sut1
337 10.30.55.13  | s31-t35-sut2
338 10.30.55.14  | s46-nomad
339 10.30.55.15  | s47-nomad
340 10.30.55.16  | s48-nomad
341 10.30.55.17  | s57-nomad
342 10.30.55.18  | s33-t27-sut1
343 10.30.55.19  | s34-t27-tg1
344 10.30.55.20  | s35-t28-sut1
345 10.30.55.21  | s36-t28-tg1
346 10.30.55.22  | s37-t29-sut1
347 10.30.55.23  | s38-t29-tg1
348 10.30.55.24  | s60-t210-sut1
349 10.30.55.25  | s61-t210-tg1
350 10.30.55.255 | Broadcast
351
352 ### Management VLAN IP Addresses
353
354 Name         | Comment
355 -------------| -------
356 10.30.51.0   | network
357 10.30.51.1   | Router
358 10.30.51.2   | LF Reserved
359 10.30.51.3   | LF Reserved
360 10.30.51.4   | LF Reserved
361 10.30.51.5   | LF Reserved
362 10.30.51.6   | LF Reserved
363 10.30.51.7   | LF Reserved
364 10.30.51.8   | LF Reserved
365 10.30.51.15  | LF Reserved
366 10.30.51.22  | s42-nomad
367 10.30.51.24  | s43-nomad
368 10.30.51.25  | s44-nomad
369 10.30.51.26  | s45-nomad
370 10.30.51.28  | s41-nomad
371 10.30.51.29  | s39-nomad
372 10.30.51.30  | s40-nomad
373 10.30.51.36  | s17-t33-sut1
374 10.30.51.37  | s18-t33-sut2
375 10.30.51.38  | fdio-marvell-dev
376 10.30.51.39  | s53-nomad
377 10.30.51.40  | s54-nomad
378 10.30.51.44  | s3-t21-sut1
379 10.30.51.45  | s4-t21-tg1
380 10.30.51.46  | s11-t31-sut1
381 10.30.51.47  | s12-t31-sut2
382 10.30.51.48  | s13-t31-tg1
383 10.30.51.49  | s19-t33t211-tg1
384 10.30.51.50  | s1-t11-sut1
385 10.30.51.51  | s2-t12-sut1
386 10.30.51.52  | s5-t22-sut1
387 10.30.51.53  | s6-t22-tg1
388 10.30.51.54  | s7-t23-sut1
389 10.30.51.55  | s8-t23-tg1
390 10.30.51.56  | s9-t24-sut1
391 10.30.51.57  | s10-t24-tg1
392 10.30.51.58  | s14-t32-sut1
393 10.30.51.59  | s15-t32-sut2
394 10.30.51.60  | s16-t32-tg1
395 10.30.51.61  | s25-t25-sut1
396 10.30.51.62  | s26-t25-tg1
397 10.30.51.65  | s52-nomad
398 10.30.51.66  | s51-nomad
399 10.30.51.67  | s49-nomad
400 10.30.51.68  | s50-nomad
401 10.30.51.69  | s27-t211-sut1
402 10.30.51.70  | s55-t13-sut1
403 10.30.51.71  | s56-t14-sut1
404 10.30.51.72  | s62-t34-sut1
405 10.30.51.73  | s63-t34-sut2
406 10.30.51.74  | s64-t34t36-tg1
407 10.30.51.75  | s65-t37-sut1
408 10.30.51.76  | s66-t37-sut2
409 10.30.51.77  | s67-t37-tg1
410 10.30.51.78  | s68-t38-sut1
411 10.30.51.79  | s69-t38-sut2
412 10.30.51.80  | s70-t38-tg1
413 10.30.51.81  | s71-t212-sut1
414 10.30.51.82  | s72-t212-tg1
415 10.30.51.83  | s73-t213-sut1
416 10.30.51.84  | s74-t213-tg1
417 10.30.51.85  | s75-t214-sut1
418 10.30.51.86  | s76-t214-tg1
419 10.30.51.87  | s77-t215-sut1
420 10.30.51.88  | s78-t215-tg1
421 10.30.51.89  | s79-t39t310-tg1
422 10.30.51.90  | s80-t311t312-tg1
423 10.30.51.91  | s58-nomad
424 10.30.51.92  | s59-nomad
425 10.30.51.255 | Broadcast
426 10.32.8.0    | network
427 10.32.8.1    | Router
428 10.32.8.10   | s28-t26t35-tg1
429 10.32.8.11   | s29-t26-sut1
430 10.32.8.12   | s30-t35-sut1
431 10.32.8.13   | s31-t35-sut2
432 10.32.8.14   | s46-nomad
433 10.32.8.15   | s47-nomad
434 10.32.8.16   | s48-nomad
435 10.32.8.17   | s57-nomad
436 10.32.8.18   | s33-t27-sut1
437 10.32.8.19   | s34-t27-tg1
438 10.32.8.20   | s35-t28-sut1
439 10.32.8.21   | s36-t28-tg1
440 10.32.8.22   | s37-t29-sut1
441 10.32.8.23   | s38-t29-tg1
442 10.32.8.24   | s60-t210-sut1
443 10.32.8.25   | s61-t210-tg1
444 10.32.8.255  | Broadcast
445
446 ## Server Specifications
447
448 ### Server Types
449
450 FD.io CSIT lab contains following server types:
451 ```
452 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
453     - Quantity: 6 servers.
454     - Physical connectivity:
455         - CIMC and host management ports.
456         - NIC ports connected in 3-node topologies.
457     - Main HW configuration:
458         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
459         - Processors: 2* E5-2699v3 2.3 GHz.
460         - RAM Memory: 16* 32GB DDR4-2133MHz.
461         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
462     - NICs configuration:
463         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
464             - PCIe Slot1: empty.
465             - PCIe Slot2: empty.
466             - PCIe Slot3: empty.
467         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
468             - PCIe Slot4: empty.
469             - PCIe Slot5: empty.
470             - PCIe Slot6: empty
471         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
472 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
473     - Quantity: 3 servers.
474     - Physical connectivity:
475         - CIMC and host management ports.
476         - NIC ports connected in 3-node topologies.
477     - Main HW configuration:
478         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
479         - Processors: 2* E5-2699v3 2.3 GHz.
480         - RAM Memory: 16* 32GB DDR4-2133MHz.
481         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
482     - NICs configuration:
483         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
484             - PCIe Slot1: empty.
485             - PCIe Slot2: empty.
486             - PCIe Slot3: empty.
487         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
488             - PCIe Slot4: empty.
489             - PCIe Slot5: empty.
490             - PCIe Slot6: empty
491         - MLOM slot: empty.
492 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
493     - Quantity: 3 servers.
494     - Physical connectivity:
495         - CIMC and host management ports.
496         - no NIC ports, standalone setup.
497     - Main HW configuration:
498         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
499         - Processors: 2* E5-2699v3 2.3 GHz.
500         - RAM Memory: 16* 32GB DDR4-2133MHz.
501         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
502     - NICs configuration:
503         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
504             - no cards.
505         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
506             - no cards.
507         - MLOM slot: empty.
508 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
509     - Quantity: ---
510     - Physical connectivity:
511         - IPMI and host management ports.
512         - NIC ports connected into 2-node and 3-node topologies.
513     - Main HW configuration:
514         - Chassis: SuperMicro SYS-7049GP-TRT.
515         - Motherboard: SuperMicro X11DPG-QT.
516         - Processors: 2* Intel Platinum 8180 2.5 GHz.
517         - RAM Memory: 16* 16GB DDR4-2666MHz.
518         - Disks: 2* 1.6TB 6G SATA SSD.
519     - NICs configuration:
520         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
521             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
522             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
523             - PCIe Slot9 5e:00.xx: empty.
524         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
525             - PCIe Slot6 86:00.xx: empty.
526             - PCIe Slot8 af:00.xx: empty.
527             - PCIe Slot10 d8:00.xx: empty.
528 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
529     - Quantity: ---
530     - Physical connectivity:
531         - IPMI and host management ports.
532         - NIC ports connected into 2-node and 3-node topologies.
533     - Main HW configuration:
534         - Chassis: SuperMicro SYS-7049GP-TRT.
535         - Motherboard: SuperMicro X11DPG-QT.
536         - Processors: 2* Intel Platinum 8180 2.5 GHz.
537         - RAM Memory: 16* 16GB DDR4-2666MHz.
538         - Disks: 2* 1.6TB 6G SATA SSD.
539     - NICs configuration:
540         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
541             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
542             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
543             - PCIe Slot9 5e:00.xx: empty.
544         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
545             - PCIe Slot6 86:00.xx: empty.
546             - PCIe Slot8 af:00.xx: empty.
547             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
548 6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
549     - Quantity: TBD based on testbed allocation.
550     - Physical connectivity:
551         - Management: serial Port (usb) for console
552         - NIC ports connected into 2-node.
553     - Main HW configuration:
554         - Chassis: Netgate XG-2758-1u
555         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
556         - RAM Memory: 16GB ECC
557         - Disks: 150 GB
558     - NICs configuration:
559         - 2x 10Gb Intel 82599ES
560         - 4x 1GB Intel I354
561 7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
562     - Quantity: 2.
563     - Physical connectivity:
564         - IPMI and host management ports.
565         - NIC ports connected into 1-node topologies.
566     - Main HW configuration:
567         - Chassis: SuperMicro SYS-7049GP-TRT.
568         - Motherboard: SuperMicro X11DPG-QT.
569         - Processors: 2* Intel Platinum 8180 2.5 GHz.
570         - RAM Memory: 16* 16GB DDR4-2666MHz.
571         - Disks: 2* 1.6TB 6G SATA SSD.
572     - NICs configuration:
573         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
574             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
575             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
576             - PCIe Slot9 5e:00.xx: empty.
577         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
578             - PCIe Slot6 86:00.xx: empty.
579             - PCIe Slot8 af:00.xx: empty.
580             - PCIe Slot10 d8:00.xx: empty.
581 8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
582     - Quantity: 1.
583     - Physical connectivity:
584         - Host management interface: 10/100/1000-BaseT.
585         - 8-port 10GE SFP+ integrated NIC.
586     - Main HW configuration:
587         - Chassis: PS10GE4NG.
588         - Motherboard: SuperMicro X11DPG-QT.
589         - Processors: Quad-Core, Intel Processor.
590         - HW accelerators: FPGA offload.
591         - RAM Memory: 64GB.
592         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
593         - Physical Interfaces: 4 * 10GE SFP+.
594         - Operating System: Native IxOS.
595     - Interface configuration:
596         - Port-1: 10GE SFP+.
597         - Port-2: 10GE SFP+.
598         - Port-3: 10GE SFP+.
599         - Port-4: 10GE SFP+.
600 9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
601     - Quantity: 1.
602     - Physical connectivity:
603         - IPMI and host management ports.
604         - NIC ports.
605     - Main HW configuration:
606         - Chassis: SuperMicro SYS-7049GP-TRT.
607         - Motherboard: SuperMicro X11DPG-QT.
608         - Processors: 2* Intel Platinum 8180 2.5 GHz.
609         - RAM Memory: 16* 16GB DDR4-2666MHz.
610         - Disks: 2* 1.6TB 6G SATA SSD.
611     - NICs configuration:
612         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
613             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
614             - PCIe Slot4 3b:00.xx: empty.
615             - PCIe Slot9 5e:00.xx: empty.
616         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
617             - PCIe Slot6 86:00.xx: empty.
618             - PCIe Slot8 af:00.xx: empty.
619             - PCIe Slot10 d8:00.xx: empty.
620 10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
621     - Quantity: 4
622     - Physical connectivity:
623         - IPMI and host management ports.
624         - NIC ports.
625     - Main HW configuration:
626         - Chassis: SuperMicro SYS-E300-9A
627         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
628         - RAM Memory: 32GB ECC
629         - Disks: 480 GB
630     - NICs configuration:
631         - 2x 10Gb Intel x553 fiber ports
632         - 2x 10Gb Intel x553 copper ports
633         - 4x 1GB Intel I350 ports
634 11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
635     - Quantity: 1.
636     - Physical connectivity:
637         - IPMI and host management ports.
638         - NIC ports connected into 1-node testbed topologies.
639     - Main HW configuration:
640         - Chassis: SuperMicro SYS-7049GP-TRT.
641         - Motherboard: SuperMicro X11DPG-QT.
642         - Processors: 2* Intel Platinum 8280 2.7 GHz.
643         - RAM Memory: 12* 16GB DDR4-2933.
644         - Disks: 2* 1.92TB SATA SSD.
645     - NICs configuration:
646         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
647             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
648             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
649             - PCIe Slot9 5e:00.xx: empty.
650         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
651             - PCIe Slot6 86:00.xx: empty.
652             - PCIe Slot8 af:00.xx: empty.
653             - PCIe Slot10 d8:00.xx: empty.
654 12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
655     - Quantity: 3
656     - Physical connectivity:
657         - IPMI and host management ports.
658         - NIC ports connected into 2-node testbed topologies.
659     - Main HW configuration:
660         - Chassis: SuperMicro SYS-7049GP-TRT.
661         - Motherboard: SuperMicro X11DPG-QT.
662         - Processors: 2* Intel Gold 6252N 2.3 GHz.
663         - RAM Memory: 12* 16GB DDR4-2933.
664         - Disks: 2* 1.92TB SATA SSD.
665     - NICs configuration:
666         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
667             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
668             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
669             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
670         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
671             - PCIe Slot6 86:00.xx: empty.
672             - PCIe Slot8 af:00.xx: empty.
673             - PCIe Slot10 d8:00.xx: empty.
674 13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
675     - Quantity: 3.
676     - Physical connectivity:
677         - IPMI and host management ports.
678         - NIC ports connected into 2-node testbed topologies.
679     - Main HW configuration:
680         - Chassis: SuperMicro SYS-7049GP-TRT.
681         - Motherboard: SuperMicro X11DPG-QT.
682         - Processors: 2* Intel Platinum 8280 2.7 GHz.
683         - RAM Memory: 12* 16GB DDR4-2933.
684         - Disks: 2* 1.92TB SATA SSD.
685     - NICs configuration:
686         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
687             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
688             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
689             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
690         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
691             - PCIe Slot6 86:00.xx: empty.
692             - PCIe Slot8 af:00.xx: empty.
693             - PCIe Slot10 d8:00.xx: empty.
694 14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
695     - Quantity: 3.
696     - Physical connectivity:
697         - CIMC and host management ports.
698         - no NIC ports, standalone setup.
699     - Main HW configuration:
700         - Chassis: SuperMicro 1029P-WTRT.
701         - Motherboard: SuperMicro X11DDW-NT.
702         - Processors: 2* Intel Platinum 8280 2.7 GHz.
703         - RAM Memory: 12* 16GB DDR4-2933.
704         - Disks: 4* 1.92TB SATA SSD.
705     - NICs configuration:
706         - Numa0:
707             - no cards.
708         - Numa1:
709             - no cards.
710 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
711     - Quantity: 1.
712     - Physical connectivity:
713         - IPMI and host management ports.
714         - NIC ports connected into 2-node testbed topologies.
715     - Main HW configuration:
716         - Chassis: SuperMicro AS-1114S-WTRT
717         - Processors: 1* AMD EPYC 7532 2.4 GHz.
718         - RAM Memory: 8* 32GB DDR4-2933.
719         - Disks: 1* 1TB SATA SSD.
720     - NICs configuration:
721         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
722             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
723             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
724             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
725 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
726     - Quantity: 1.
727     - Physical connectivity:
728         - IPMI and host management ports.
729         - NIC ports connected into 2-node testbed topologies.
730     - Main HW configuration:
731         - Chassis: SuperMicro AS-1114S-WTRT
732         - Processors: 1* AMD EPYC 7532 2.4 GHz.
733         - RAM Memory: 8* 32GB DDR4-2933.
734         - Disks: 1* 1TB SATA SSD.
735     - NICs configuration:
736         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
737             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
738             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
739             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
740 17.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
741     - Quantity: 2
742     - Physical connectivity:
743         - IPMI and host management ports.
744         - NIC ports connected into 1-node topologies.
745     - Main HW configuration:
746         - Chassis: GIGABYTE Rack Mount
747         - Motherboard: MT91-FS4-00
748         - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
749         - RAM Memory: 16 * 16GB DIMM
750         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
751     - NICs configuration:
752         - Numa0:
753             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
754             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
755         - Numa1:
756             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
757             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
758 18.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
759     - Quantity: 2
760     - Physical connectivity:
761         - IPMI(?) and host management ports.
762         - NIC ports connected into 3-node topology.
763     - Main HW configuration:
764         - Chassis: Huawei TaiShan 2280.
765         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
766         - RAM Memory: 8* 16GB DDR4-2400MT/s
767         - Disks: 1* 4TB SATA HDD
768     - NICs configuration:
769         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
770         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
771 19.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
772     - Quantity: 1
773     - Physical connectivity:
774         - IPMI and host management ports.
775         - NIC ports connected into 2-node topologies.
776     - Main HW configuration:
777         - Chassis: Gigabyte R181-T90 1U
778         - Motherboard: MT91-FS1
779         - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
780         - RAM Memory: 4* 32GB RDIMM
781         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
782     - NICs configuration:
783         - Numa0:
784             - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
785         - Numa1:
786             - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
787 20.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
788     - Quantity: 1
789     - Physical connectivity:
790         - IPMI and host management ports.
791         - NIC ports connected into 3-node topologies.
792     - Main HW configuration:
793         - Chassis: TBD
794         - Motherboard: TBD
795         - Processors: n* TBD
796         - RAM Memory: n* TBD
797         - Disks: TBD
798     - NICs configuration:
799         - Numa0:
800             - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
801             - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
802         - Numa1:
803             - PCIe Slotn xx:xx.xx: XL710-QDA2-2p40GE Intel.
804             - PCIe Slotk xx:xx.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
805 21.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
806     - Quantity: 1
807     - Physical connectivity:
808         - IPMI and host management ports.
809         - NIC ports connected into 2-node and 3-node topologies.
810     - Main HW configuration:
811         - Chassis: SuperMicro SYS-7049GP-TRT.
812         - Motherboard: SuperMicro X11DPG-QT.
813         - Processors: 2* Intel Platinum 8180 2.5 GHz.
814         - RAM Memory: 16* 16GB DDR4-2666MHz.
815         - Disks: 2* 1.6TB 6G SATA SSD.
816     - NICs configuration:
817         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
818             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
819             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
820             - PCIe Slot9 5e:00.xx: empty.
821         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
822             - PCIe Slot6 86:00.xx: empty.
823             - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
824             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
825 22. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
826     - Quantity: 8.
827     - Physical connectivity:
828         - IPMI and host management ports.
829         - NIC ports connected into 2-node or 3-node testbed topologies.
830     - Main HW configuration:
831         - Chassis: SuperMicro SYS-740GP-TNRT.
832         - Motherboard: Super X12DPG-QT6.
833         - Processors: 2* Intel Platinum 8358 2.6 GHz.
834         - RAM Memory: 16* 16GB DDR4-3200.
835         - Disks: 2* 960GB SATA SSD.
836     - NICs configuration:
837         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
838             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
839             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
840             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
841         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
842             - PCIe Slot6 86:00.xx: empty.
843             - PCIe Slot8 af:00.xx: empty.
844             - PCIe Slot10 d8:00.xx: empty.
845 23. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
846     - Quantity: 3.
847     - Physical connectivity:
848         - IPMI and host management ports.
849         - NIC ports connected into 2-node testbed topologies.
850     - Main HW configuration:
851         - Chassis: SuperMicro SYS-740GP-TNRT.
852         - Motherboard: Super X12DPG-QT6.
853         - Processors: 2* Intel Platinum 8358 2.6 GHz.
854         - RAM Memory: 16* 16GB DDR4-3200.
855         - Disks: 2* 960GB SATA SSD.
856     - NICs configuration:
857         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
858             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
859             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
860             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
861         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
862             - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
863             - PCIe Slot8 af:00.xx: empty.
864             - PCIe Slot10 d8:00.xx: empty.
865 24. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
866     - Quantity: 3.
867     - Physical connectivity:
868         - IPMI and host management ports.
869         - NIC ports connected into 3-node testbed topologies.
870     - Main HW configuration:
871         - Chassis: SuperMicro SYS-740GP-TNRT.
872         - Motherboard: Super X12DPG-QT6.
873         - Processors: 2* Intel Platinum 8358 2.6 GHz.
874         - RAM Memory: 16* 16GB DDR4-3200.
875         - Disks: 2* 960GB SATA SSD.
876     - NICs configuration:
877         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
878             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
879             - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
880             - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
881         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
882             - PCIe Slot6 86:00.xx: empty.
883             - PCIe Slot8 af:00.xx: empty.
884             - PCIe Slot10 d8:00.xx: empty.
885 25. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
886     - Quantity: 3.
887     - Physical connectivity:
888         - IPMI and host management ports.
889         - NIC ports connected into 2-node and/or 3-node testbed topologies.
890     - Main HW configuration:
891         - Chassis: SuperMicro SYS-740GP-TNRT.
892         - Motherboard: Super X12DPG-QT6.
893         - Processors: 2* Intel Platinum 8358 2.6 GHz.
894         - RAM Memory: 16* 16GB DDR4-3200.
895         - Disks: 2* 960GB SATA SSD.
896     - NICs configuration:
897         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
898             - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
899             - PCIe Slot4 3b:00.xx: empty.
900             - PCIe Slot9 5e:00.xx: empty.
901         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
902             - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
903             - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
904             - PCIe Slot10 d8:00.xx: empty.
905 26. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
906     - Quantity: 2.
907     - Physical connectivity:
908         - IPMI and host management ports.
909     - Main HW configuration:
910         - Chassis: Gigabyte R152-P30-00 1U
911         - Motherboard: MP32-AR1-00
912         - Processors: 1* Ampere(R) Altra(R) Processor (Neoverse N1)
913         - RAM Memory: 4* 16GB RDIMM-3200MHz
914         - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
915 ```
916
917 ### Naming Convention
918
919 Following naming convention is used within this page to specify physical
920 connectivity and wiring across defined CSIT testbeds:
921
922 ```
923 - testbedname: testbedN.
924 - hostname:
925     - traffic-generator: tN-tgW.
926     - system-under-testX: tN-sutX.
927 - portnames:
928     - tN-tgW-cY/pZ.
929     - tN-sutX-cY/pZ.
930 - where:
931     - N - testbed number.
932     - tgW - server acts as traffic-generator with W index.
933     - sutX - server acts as system-under-test with X index.
934     - Y - PCIe slot number denoting a NIC card number within the host.
935     - Z - port number on the NIC card.
936 ```
937
938 ## Testbeds Configuration
939
940 ### Per Testbed Server Allocation and Naming
941
942 #### 1-Node-Skylake Servers (1n-skx) PROD
943
944 ```
945 - SUT [Server-Type-B6]:
946     - testbedname: testbed11.
947     - hostname: s1-t11-sut1.
948     - IPMI IP: 10.30.50.47
949     - Host IP: 10.30.51.50
950     - portnames:
951         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
952         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
953         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
954         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
955         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
956         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
957         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
958         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
959 - SUT [Server-Type-B6]:
960     - testbedname: testbed12.
961     - hostname: s2-t12-sut1.
962     - IPMI IP: 10.30.50.48
963     - Host IP: 10.30.51.51
964     - portnames:
965         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
966         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
967         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
968         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
969         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
970         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
971         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
972         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
973 ```
974
975 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
976
977 ```
978 - SUT [Server-Type-E11]:
979     - testbedname: testbed13
980     - hostname: s55-t13-sut1
981     - IPMI IP: 10.30.50.70
982     - Host IP: 10.30.51.70
983     - portnames:
984         - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
985         - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
986         - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
987         - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
988         - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
989         - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
990         - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
991         - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
992 - SUT [Server-Type-E11]:
993     - testbedname: testbed14
994     - hostname: s56-t14-sut1
995     - IPMI IP: 10.30.50.71
996     - Host IP: 10.30.51.71
997     - portnames:
998         - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
999         - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1000         - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1001         - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1002         - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1003         - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1004         - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
1005         - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
1006 ```
1007
1008 #### 1-Node-Cascadelake Servers (1n-clx) PROD
1009
1010 ```
1011 - SUT [Server-Type-C1]:
1012     - testbedname: testbed11.
1013     - hostname: s32-t14-sut1.
1014     - IPMI IP: 10.30.55.17
1015     - Host IP: 10.32.8.17
1016     - portnames:
1017         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1018         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1019         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1020         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1021         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
1022         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
1023         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
1024         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
1025 ```
1026
1027 #### 2-Node-Skylake Servers (2n-skx) PROD
1028
1029 ```
1030 - SUT [Server-Type-B1]:
1031     - testbedname: testbed21.
1032     - hostname: s3-t21-sut1.
1033     - IPMI IP: 10.30.50.41
1034     - Host IP: 10.30.51.44
1035     - portnames:
1036         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1037         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1038         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1039         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1040         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1041         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1042 - TG [Server-Type-B2]:
1043     - testbedname: testbed21.
1044     - hostname: s4-t21-tg1.
1045     - IPMI IP: 10.30.50.42
1046     - Host IP: 10.30.51.45
1047     - portnames:
1048         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1049         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1050         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1051         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1052         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1053         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1054         - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1055         - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1056         - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1057         - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1058 - SUT [Server-Type-B1]:
1059     - testbedname: testbed22.
1060     - hostname: s5-t22-sut1.
1061     - IPMI IP: 10.30.50.49
1062     - Host IP: 10.30.51.52
1063     - portnames:
1064         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1065         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1066         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1067         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1068         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1069         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1070 - TG [Server-Type-B2]:
1071     - testbedname: testbed22.
1072     - hostname: s6-t22-tg1.
1073     - IPMI IP: 10.30.50.50
1074     - Host IP: 10.30.51.53
1075     - portnames:
1076         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1077         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1078         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1079         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1080         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1081         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1082         - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1083         - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1084         - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1085         - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1086 - SUT [Server-Type-B1]:
1087     - testbedname: testbed23.
1088     - hostname: s7-t23-sut1.
1089     - IPMI IP: 10.30.50.51
1090     - Host IP: 10.30.51.54
1091     - portnames:
1092         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1093         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1094         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1095         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1096         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1097         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1098 - TG [Server-Type-B2]:
1099     - testbedname: testbed23.
1100     - hostname: s8-t23-tg1.
1101     - IPMI IP: 10.30.50.52
1102     - Host IP: 10.30.51.55
1103     - portnames:
1104         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1105         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1106         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1107         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1108         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1109         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1110         - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1111         - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1112         - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1113         - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1114 - SUT [Server-Type-B1]:
1115     - testbedname: testbed24.
1116     - hostname: s9-t24-sut1.
1117     - IPMI IP: 10.30.50.53
1118     - Host IP: 10.30.51.56
1119     - portnames:
1120         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1121         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1122         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1123         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1124         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1125         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1126 - TG [Server-Type-B2]:
1127     - testbedname: testbed24.
1128     - hostname: s10-t24-tg1.
1129     - IPMI IP: 10.30.50.54
1130     - Host IP: 10.30.51.57
1131     - portnames:
1132         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1133         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1134         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1135         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1136         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1137         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1138         - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1139         - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1140         - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1141         - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1142 ```
1143
1144 #### 2-Node-Denverton Servers (2n-dnv) PROD
1145
1146 Note: ServerB28 (TG) is shared between testbed26 & testbed35
1147
1148 ```
1149 - TG [Server-Type-B2]:
1150     - testbednames: testbed26 and testbed35.
1151     - hostname: s28-t26t35-tg1.
1152     - IPMI IP: 10.30.55.10
1153     - Host IP: 10.32.8.10
1154     - portnames:
1155         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
1156         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
1157         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
1158         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
1159         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
1160         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
1161         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
1162         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
1163         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
1164         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
1165         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1166         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1167 - SUT [Server-Type-B10]:
1168     - testbednames: testbed26.
1169     - hostname: s29-t26-sut1.
1170     - IPMI IP: 10.30.55.11
1171     - Host IP: 10.32.8.11
1172     - portnames:
1173         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1174         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1175         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1176         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1177 ```
1178
1179 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1180
1181 ```
1182 - SUT [Server-Type-B8]:
1183     - testbedname: testbed25.
1184     - hostname: s25-t25-sut1.
1185     - IPMI IP: 10.30.50.58
1186     - Host IP: 10.30.51.61
1187     - portnames:
1188         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1189         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1190         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1191         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1192 - TG [Server-Type-B7]:
1193     - testbedname: testbed25.
1194     - hostname: s26-t25-tg1.
1195     - IPMI IP: 10.30.50.59
1196     - Host IP: 10.30.51.62
1197     - portnames:
1198         - s26-t25-tg1-p1 - 10GE-port1.
1199         - s26-t25-tg1-p2 - 10GE-port2.
1200         - s26-t25-tg1-p3 - 10GE-port3.
1201         - s26-t25-tg1-p4 - 10GE-port4.
1202 ```
1203
1204 #### 2-Node-Cascadelake Servers (2n-clx) PROD
1205
1206 ```
1207 - SUT [Server-Type-C2]:
1208     - testbedname: testbed27.
1209     - hostname: s33-t27-sut1.
1210     - IPMI IP: 10.30.55.18
1211     - Host IP: 10.32.8.18
1212     - portnames:
1213         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1214         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1215         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1216         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1217         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1218         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1219         - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1220         - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1221         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1222         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1223 - TG [Server-Type-C3]:
1224     - testbedname: testbed27.
1225     - hostname: s34-t27-tg1.
1226     - IPMI IP: 10.30.55.19
1227     - Host IP: 10.32.8.19
1228     - portnames:
1229         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1230         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1231         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1232         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1233         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1234         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1235         - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1236         - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1237         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1238         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1239 - SUT [Server-Type-C2]:
1240     - testbedname: testbed28.
1241     - hostname: s35-t28-sut1.
1242     - IPMI IP: 10.30.55.20
1243     - Host IP: 10.32.8.20
1244     - portnames:
1245         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1246         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1247         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1248         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1249         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1250         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1251         - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1252         - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1253         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1254         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1255 - TG [Server-Type-C3]:
1256     - testbedname: testbed28.
1257     - hostname: s36-t28-tg1.
1258     - IPMI IP: 10.30.55.21
1259     - Host IP: 10.32.8.21
1260     - portnames:
1261         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1262         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1263         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1264         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1265         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1266         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1267         - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1268         - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1269         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1270         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1271 - SUT [Server-Type-C2]:
1272     - testbedname: testbed29.
1273     - hostname: s37-t29-sut1.
1274     - IPMI IP: 10.30.55.22
1275     - Host IP: 10.32.8.22
1276     - portnames:
1277         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1278         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1279         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1280         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1281         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1282         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1283         - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
1284         - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
1285         - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1286         - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1287 - TG [Server-Type-C3]:
1288     - testbedname: testbed29.
1289     - hostname: s38-t29-tg1.
1290     - IPMI IP: 10.30.55.23
1291     - Host IP: 10.32.8.23
1292     - portnames:
1293         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1294         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1295         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1296         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1297         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1298         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1299         - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
1300         - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
1301         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1302         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1303 ```
1304
1305 #### 2-Node-Zen2 Servers (2n-zn2) PROD
1306
1307 ```
1308 - SUT [Server-Type-D1]:
1309     - testbedname: testbed210.
1310     - hostname: s60-t210-sut1.
1311     - IPMI IP: 10.30.55.24
1312     - Host IP: 10.32.8.24
1313     - portnames:
1314         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1315         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1316         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1317         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1318         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1319         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1320         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1321         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1322 - TG [Server-Type-D2]:
1323     - testbedname: testbed210.
1324     - hostname: s61-t210-tg1.
1325     - IPMI IP: 10.30.55.25
1326     - Host IP: 10.32.8.25
1327     - portnames:
1328         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1329         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1330         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1331         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1332         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1333         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1334         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1335         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1336 ```
1337
1338 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
1339
1340 Note: Server19 (TG) is shared between testbed33 & testbed211
1341
1342 ```
1343 - SUT [Server-Type-E22]:
1344     - testbedname: testbed211.
1345     - hostname: s27-t211-sut1.
1346     - IPMI IP: 10.30.50.69
1347     - Host IP: 10.30.51.69
1348     - portnames:
1349         - s27-t211-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1350         - s27-t211-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1351         - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
1352         - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
1353 - TG [Server-Type-E31]:
1354     - testbedname: testbed33 and testbed211.
1355     - hostname: s19-t33t211-tg1.
1356     - IPMI IP: 10.30.50.46
1357     - Host IP: 10.30.51.49
1358     - portnames:
1359         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1360         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1361         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1362         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1363         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1364         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1365         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1366         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1367         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1368         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1369         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1370         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1371 ```
1372
1373 #### 2-Node-Icelake Servers (2n-icx) TBD
1374
1375 ```
1376 - SUT [Server-Type-F1]:
1377     - testbedname: testbed212.
1378     - hostname: s71-t212-sut1.
1379     - IPMI IP: 10.30.51.81
1380     - Host IP: 10.30.50.81
1381     - portnames:
1382         - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1383         - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1384         - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1385         - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1386         - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1387         - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1388         - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1389         - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1390 - TG [Server-Type-F2]:
1391     - testbedname: testbed212.
1392     - hostname: s72-t212-tg1.
1393     - IPMI IP: 10.30.51.82
1394     - Host IP: 10.30.50.82
1395     - portnames:
1396         - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1397         - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1398         - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1399         - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1400         - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1401         - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1402         - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1403         - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1404         - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1405         - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1406 - SUT [Server-Type-F1]:
1407     - testbedname: testbed213.
1408     - hostname: s73-t213-sut1.
1409     - IPMI IP: 10.30.51.83
1410     - Host IP: 10.30.50.83
1411     - portnames:
1412         - s73-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1413         - s73-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1414         - s73-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1415         - s73-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1416         - s73-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1417         - s73-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1418         - s73-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1419         - s73-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1420 - TG [Server-Type-F2]:
1421     - testbedname: testbed213.
1422     - hostname: s74-t213-tg1.
1423     - IPMI IP: 10.30.51.84
1424     - Host IP: 10.30.50.84
1425     - portnames:
1426         - s74-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1427         - s74-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1428         - s74-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1429         - s74-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1430         - s74-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1431         - s74-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1432         - s74-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1433         - s74-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1434         - s74-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1435         - s74-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1436 - SUT [Server-Type-F1]:
1437     - testbedname: testbed214.
1438     - hostname: s75-t214-sut1.
1439     - IPMI IP: 10.30.51.85
1440     - Host IP: 10.30.50.85
1441     - portnames:
1442         - s75-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1443         - s75-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1444         - s75-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1445         - s75-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1446         - s75-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1447         - s75-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1448         - s75-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1449         - s75-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1450 - TG [Server-Type-F2]:
1451     - testbedname: testbed214.
1452     - hostname: s76-t214-tg1.
1453     - IPMI IP: 10.30.51.86
1454     - Host IP: 10.30.50.86
1455     - portnames:
1456         - s76-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1457         - s76-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1458         - s76-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1459         - s76-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1460         - s76-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1461         - s76-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1462         - s76-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1463         - s76-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1464         - s76-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1465         - s76-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1466 - SUT [Server-Type-F1]:
1467     - testbedname: testbed215.
1468     - hostname: s77-t215-sut1.
1469     - IPMI IP: 10.30.51.87
1470     - Host IP: 10.30.50.87
1471     - portnames:
1472         - s77-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1473         - s77-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1474         - s77-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1475         - s77-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1476         - s77-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1477         - s77-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1478         - s77-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1479         - s77-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1480 - TG [Server-Type-F2]:
1481     - testbedname: testbed215.
1482     - hostname: s78-t215-tg1.
1483     - IPMI IP: 10.30.51.88
1484     - Host IP: 10.30.50.88
1485     - portnames:
1486         - s78-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1487         - s78-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1488         - s78-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1489         - s78-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1490         - s78-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1491         - s78-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1492         - s78-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1493         - s78-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1494         - s78-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1495         - s78-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1496 ```
1497
1498 #### 3-Node-Skylake Servers (3n-skx) PROD
1499
1500 ```
1501 - ServerB11 [Server-Type-B1]:
1502     - testbedname: testbed31.
1503     - hostname: s11-t31-sut1.
1504     - IPMI IP: 10.30.50.43
1505     - Host IP: 10.30.51.46
1506     - portnames:
1507         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1508         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1509         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1510         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1511         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1512         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1513 - ServerB12 [Server-Type-B1]:
1514     - testbedname: testbed31.
1515     - hostname: s12-t31-sut2.
1516     - IPMI IP: 10.30.50.44
1517     - Host IP: 10.30.51.47
1518     - portnames:
1519         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1520         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1521         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1522         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1523         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1524         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1525 - ServerB13 [Server-Type-B2]:
1526     - testbedname: testbed31.
1527     - hostname: s13-t31-tg1.
1528     - IPMI IP: 10.30.50.45
1529     - Host IP: 10.30.51.48
1530     - portnames:
1531         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1532         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1533         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1534         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1535         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1536         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1537         - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1538         - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1539         - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1540         - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1541 - ServerB14 [Server-Type-B1]:
1542     - testbedname: testbed32.
1543     - hostname: s14-t32-sut1.
1544     - IPMI IP: 10.30.50.55
1545     - Host IP: 10.30.51.58
1546     - portnames:
1547         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1548         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1549         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1550         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1551         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1552         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1553 - ServerB15 [Server-Type-B1]:
1554     - testbedname: testbed32.
1555     - hostname: s15-t32-sut2.
1556     - IPMI IP: 10.30.50.56
1557     - Host IP: 10.30.51.59
1558     - portnames:
1559         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1560         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1561         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1562         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1563         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1564         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1565 - ServerB16 [Server-Type-B2]:
1566     - testbedname: testbed32.
1567     - hostname: s16-t32-tg1.
1568     - IPMI IP: 10.30.50.57
1569     - Host IP: 10.30.51.60
1570     - portnames:
1571         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1572         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1573         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1574         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1575         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1576         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1577         - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1578         - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1579         - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1580         - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1581 ```
1582
1583 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1584
1585 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1586
1587 ```
1588 - ServerB22 [Server-Type-B5]:
1589     - testbedname: testbed35.
1590     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1591     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1592     - Host IP: 10.30.51.9
1593     - portnames:
1594         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1595         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1596     - 1GB ports (tbd)
1597 - ServerB23 [Server-Type-B5]:
1598     - testbedname: testbed35.
1599     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1600     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1601     - Host IP: 10.30.51.10
1602     - portnames:
1603         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1604         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1605     - 1GB ports (tbd)
1606 - ServerB24 [Server-Type-B5]:
1607     - testbedname: testbed35.
1608     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1609     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1610     - Host IP: 10.30.51.11
1611     - portnames:
1612         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1613         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1614     - 1GB ports (tbd)
1615 ```
1616
1617 #### 3-Node-Taishan Servers (3n-tsh) PROD
1618
1619 Note: Server19 (TG) is shared between testbed33 & testbed211
1620
1621 ```
1622 - SUT [Server-Type-E21]:
1623     - testbedname: testbed33.
1624     - hostname: s17-t33-sut1.
1625     - IPMI IP: 10.30.50.36
1626     - Host IP: 10.30.51.36
1627     - portnames:
1628         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1629         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1630         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1631         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1632 - SUT [Server-Type-E21]:
1633     - testbedname: testbed33.
1634     - hostname: s18-t33-sut2.
1635     - IPMI IP: 10.30.50.37
1636     - Host IP: 10.30.51.37
1637     - portnames:
1638         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1639         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1640         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1641         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1642 - TG [Server-Type-E31]:
1643     - testbedname: testbed33 and testbed211.
1644     - hostname: s19-t33t211-tg1.
1645     - IPMI IP: 10.30.50.46
1646     - Host IP: 10.30.51.49
1647     - portnames:
1648         - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1649         - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1650         - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1651         - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1652         - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1653         - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1654         - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1655         - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1656         - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1657         - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1658         - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1659         - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1660 ```
1661
1662 #### 3-Node-Altra Servers (3n-alt) TBD
1663
1664 Note: Server64 (TG) is shared between testbed34 & testbed36
1665
1666 ```
1667 - SUT [Server-Type-E23]:
1668     - testbedname: testbed34.
1669     - hostname: s62-t34-sut1.
1670     - IPMI IP: 10.30.50.72
1671     - Host IP: 10.30.51.72
1672     - portnames:
1673         - s62-t34-sut1-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1674         - s62-t34-sut1-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1675         - s62-t34-sut1-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1676         - s62-t34-sut1-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1677 - SUT [Server-Type-E23]:
1678     - testbedname: testbed34.
1679     - hostname: s63-t34-sut2.
1680     - IPMI IP: 10.30.50.73
1681     - Host IP: 10.30.51.73
1682     - portnames:
1683         - s63-t34-sut2-cn/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1684         - s63-t34-sut2-cn/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1685         - s63-t34-sut2-ck/p1 - 100GE-port1 ConnectX5-2p100GE.
1686         - s63-t34-sut2-ck/p2 - 100GE-port1 ConnectX5-2p100GE.
1687 - TG [Server-Type-F4]:
1688     - testbedname: testbed34.
1689     - hostname: s64-t34t36-tg1.
1690     - IPMI IP: 10.30.50.74
1691     - Host IP: 10.30.51.74
1692     - portnames:
1693         - s64-t34-tg1-c1/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1694         - s64-t34-tg1-c1/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1695 ```
1696
1697 #### 3-Node-Denverton Servers (3n-dnv) PROD
1698
1699 ```
1700 - ServerB30 [Server-Type-B10]:
1701     - testbednames: testbed35.
1702     - hostname: s30-t35-sut1.
1703     - IPMI IP: 10.30.55.12
1704     - Host IP: 10.32.8.12
1705     - portnames:
1706         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1707         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1708         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1709         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1710 - ServerB31 [Server-Type-B10]:
1711     - testbednames: testbed35.
1712     - hostname: s31-t35-sut2.
1713     - IPMI IP: 10.30.55.13
1714     - Host IP: 10.32.8.13
1715     - portnames:
1716         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1717         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1718         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1719         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1720 ```
1721
1722 #### 3-Node-Icelake Servers (3n-icx) TBD
1723
1724 ```
1725 - ServerF1 [Server-Type-F1]:
1726     - testbedname: testbed37.
1727     - hostname: s65-t37-sut1.
1728     - IPMI IP: 10.30.50.75
1729     - Host IP: 10.30.51.75
1730     - portnames:
1731         - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1732         - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1733         - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1734         - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1735         - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1736         - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1737         - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1738         - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1739 - ServerF1 [Server-Type-F1]:
1740     - testbedname: testbed37.
1741     - hostname: s66-t37-sut2.
1742     - IPMI IP: 10.30.50.76
1743     - Host IP: 10.30.51.76
1744     - portnames:
1745         - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1746         - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1747         - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1748         - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1749         - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1750         - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1751         - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1752         - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1753 - ServerF3 [Server-Type-F3]:
1754     - testbedname: testbed37.
1755     - hostname: s67-t37-tg1.
1756     - IPMI IP: 10.30.50.77
1757     - Host IP: 10.30.51.77
1758     - portnames:
1759         - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1760         - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1761         - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1762         - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1763         - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1764         - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1765         - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1766         - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1767 - ServerF1 [Server-Type-F1]:
1768     - testbedname: testbed38.
1769     - hostname: s68-t38-sut1.
1770     - IPMI IP: 10.30.50.78
1771     - Host IP: 10.30.51.78
1772     - portnames:
1773         - s68-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1774         - s68-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1775         - s68-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1776         - s68-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1777         - s68-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1778         - s68-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1779         - s68-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1780         - s68-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1781 - ServerF1 [Server-Type-F1]:
1782     - testbedname: testbed38.
1783     - hostname: s69-t38-sut2.
1784     - IPMI IP: 10.30.50.79
1785     - Host IP: 10.30.51.79
1786     - portnames:
1787         - s69-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1788         - s69-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1789         - s69-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1790         - s69-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1791         - s69-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1792         - s69-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1793         - s69-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1794         - s69-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1795 - ServerF3 [Server-Type-F3]:
1796     - testbedname: testbed38.
1797     - hostname: s70-t38-tg1.
1798     - IPMI IP: 10.30.50.80
1799     - Host IP: 10.30.51.80
1800     - portnames:
1801         - s70-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1802         - s70-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1803         - s70-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1804         - s70-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1805         - s70-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1806         - s70-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1807         - s70-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1808         - s70-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1809 ```
1810
1811 ### Per Testbed Wiring
1812
1813 #### 1-Node-Skylake Wiring (1n-skx) PROD
1814
1815 ```
1816 - testbed11:
1817     - ring1 10GE-ports x710-4p10GE:
1818         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1819     - ring2 10GE-ports x710-4p10GE:
1820         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1821     - ring3 10GE-ports x710-4p10GE:
1822         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1823     - ring4 10GE-ports x710-4p10GE:
1824         - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1825     - ring5 100GE-ports e810-2p100GE:
1826         - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1827     - ring6 100GE-ports e810-2p100GE:
1828         - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1829 - testbed12:
1830     - ring1 10GE-ports x710-4p10GE:
1831         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1832     - ring2 10GE-ports x710-4p10GE:
1833         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1834     - ring3 10GE-ports x710-4p10GE:
1835         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1836     - ring4 10GE-ports x710-4p10GE:
1837         - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1838     - ring5 100GE-ports e810-2p100GE:
1839         - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1840     - ring6 100GE-ports e810-2p100GE:
1841         - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1842 ```
1843
1844 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1845
1846 ```
1847 - testbed13:
1848     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1849         - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1850     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1851         - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1852     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1853         - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1854     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1855         - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1856
1857 - testbed14:
1858     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1859         - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1860     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1861         - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1862     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1863         - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1864     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1865         - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1866 ```
1867
1868 #### 2-Node-Skylake Wiring (2n-skx) PROD
1869
1870 ```
1871 - testbed21:
1872     - ring1 10GE-ports x710-4p10GE on SUT:
1873         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1874         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1875     - ring2 10GE-ports x710-4p10GE on SUT:
1876         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1877         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1878     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1879         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1880         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1881     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1882         - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
1883         - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
1884 - testbed22:
1885     - ring1 10GE-ports x710-4p10GE on SUT:
1886         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1887         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1888     - ring2 10GE-ports x710-4p10GE on SUT:
1889         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1890         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1891     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1892         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1893         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1894     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1895         - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
1896         - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
1897 - testbed23:
1898     - ring1 10GE-ports x710-4p10GE on SUT:
1899         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1900         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1901     - ring2 10GE-ports x710-4p10GE on SUT:
1902         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1903         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1904     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1905         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1906         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1907     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1908         - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
1909         - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
1910 - testbed24:
1911     - ring1 10GE-ports x710-4p10GE on SUT:
1912         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1913         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1914     - ring2 10GE-ports x710-4p10GE on SUT:
1915         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1916         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1917     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1918         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1919         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1920     - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1921         - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
1922         - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
1923 ```
1924
1925 #### 2-Node-Denverton Wiring (2n-dnv) PROD
1926
1927 ```
1928 - testbed26:
1929     - ring1 10GE-ports x553 copper port on SUT:
1930         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1931         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1932     - ring2 10GE-ports x553 fiber port on SUT:
1933         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1934         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1935 ```
1936
1937 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1938
1939 ```
1940 - testbed25:
1941     - link1 10GE-port x710-4p10GE on SUT:
1942         - t25-tg1-p1 to t25-sut1-c2/p1.
1943     - link2 10GE-port x710-4p10GE on SUT:
1944         - t25-tg1-p2 to t25-sut1-c2/p2.
1945     - link3 10GE-port x710-4p10GE on SUT:
1946         - t25-tg1-p3 to t25-sut1-c2/p3.
1947     - link4 10GE-port x710-4p10GE on SUT:
1948         - t25-tg1-p4 to t25-sut1-c2/p4.
1949 ```
1950
1951 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1952
1953 ```
1954 - testbed27:
1955     - ring1 10GE-ports x710-4p10GE on SUT:
1956         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1957         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1958     - ring2 10GE-ports x710-4p10GE on SUT:
1959         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1960         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1961     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1962         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1963         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1964     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1965         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1966         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1967     - ring5 100GE-ports e810-2p100GE on SUT:
1968         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1969         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1970 - testbed28:
1971     - ring1 10GE-ports x710-4p10GE on SUT:
1972         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1973         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1974     - ring2 10GE-ports x710-4p10GE on SUT:
1975         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1976         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1977     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1978         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1979         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1980     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1981         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1982         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1983     - ring5 100GE-ports e810-2p100GE on SUT:
1984         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1985         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1986 - testbed29:
1987     - ring1 10GE-ports x710-4p10GE on SUT:
1988         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1989         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1990     - ring2 10GE-ports x710-4p10GE on SUT:
1991         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1992         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1993     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1994         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1995         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1996     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1997         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1998         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1999     - ring6 100GE-ports e810-2p100GE on SUT:
2000         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
2001         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
2002 ```
2003
2004 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
2005
2006 ```
2007 - testbed210:
2008     - ring1 10GE-ports x710-4p10GE on SUT:
2009         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
2010         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
2011     - ring2 10GE-ports x710-4p10GE on SUT:
2012         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
2013         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
2014     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2015         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
2016         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
2017     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
2018         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
2019         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
2020 ```
2021
2022 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
2023
2024 ```
2025 - testbed211:
2026     - ring1 10GE-ports x520-2p10GE on SUTs:
2027         - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
2028         - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
2029 ```
2030
2031 #### 2-Node-Icelake Wiring (2n-icx) TBD
2032
2033 ```
2034 - testbed212:
2035     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2036         - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
2037         - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
2038     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2039         - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
2040         - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
2041         - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
2042         - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
2043     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2044         - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
2045         - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
2046     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2047         - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
2048         - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
2049 - testbed213:
2050     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2051         - s74-t213-tg1-c2/p1 to s73-t213-sut1-c2/p1.
2052         - s73-t213-sut1-c2/p2 to s74-t213-tg1-c2/p2.
2053     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2054         - s74-t213-tg1-c4/p1 to s73-t213-sut1-c4/p1.
2055         - s73-t213-sut1-c4/p2 to s74-t213-tg1-c4/p2.
2056         - s74-t213-tg1-c4/p3 to s73-t213-sut1-c4/p3.
2057         - s73-t213-sut1-c4/p4 to s74-t213-tg1-c4/p4.
2058     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2059         - s74-t213-tg1-c9/p1 to s73-t213-sut1-c9/p1.
2060         - s73-t213-sut1-c9/p2 to s74-t213-tg1-c9/p2.
2061     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2062         - s74-t213-tg1-c6/p1 to s74-t213-tg1-c6/p2.
2063         - s74-t213-tg1-c6/p2 to s74-t213-tg1-c6/p1.
2064 - testbed214:
2065     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2066         - s76-t214-tg1-c2/p1 to s75-t214-sut1-c2/p1.
2067         - s75-t214-sut1-c2/p2 to s76-t214-tg1-c2/p2.
2068     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2069         - s76-t214-tg1-c4/p1 to s75-t214-sut1-c4/p1.
2070         - s75-t214-sut1-c4/p2 to s76-t214-tg1-c4/p2.
2071         - s76-t214-tg1-c4/p3 to s75-t214-sut1-c4/p3.
2072         - s75-t214-sut1-c4/p4 to s76-t214-tg1-c4/p4.
2073     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2074         - s76-t214-tg1-c9/p1 to s75-t214-sut1-c9/p1.
2075         - s75-t214-sut1-c9/p2 to s76-t214-tg1-c9/p2.
2076     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2077         - s76-t214-tg1-c6/p1 to s76-t214-tg1-c6/p2.
2078         - s76-t214-tg1-c6/p2 to s76-t214-tg1-c6/p1.
2079 - testbed215:
2080     - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
2081         - s78-t215-tg1-c2/p1 to s77-t215-sut1-c2/p1.
2082         - s77-t215-sut1-c2/p2 to s78-t215-tg1-c2/p2.
2083     - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
2084         - s78-t215-tg1-c4/p1 to s77-t215-sut1-c4/p1.
2085         - s77-t215-sut1-c4/p2 to s78-t215-tg1-c4/p2.
2086         - s78-t215-tg1-c4/p3 to s77-t215-sut1-c4/p3.
2087         - s77-t215-sut1-c4/p4 to s78-t215-tg1-c4/p4.
2088     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
2089         - s78-t215-tg1-c9/p1 to s77-t215-sut1-c9/p1.
2090         - s77-t215-sut1-c9/p2 to s78-t215-tg1-c9/p2.
2091     - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
2092         - s78-t215-tg1-c6/p1 to s78-t215-tg1-c6/p2.
2093         - s78-t215-tg1-c6/p2 to s78-t215-tg1-c6/p1.
2094 ```
2095
2096 #### 3-Node-Skylake Wiring (3n-skx) PROD
2097
2098 ```
2099 - testbed31:
2100     - ring1 10GE-ports x710-4p10GE on SUTs:
2101         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
2102         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
2103         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
2104     - ring2 10GE-ports x710-4p10GE on SUT:
2105         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
2106         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
2107         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
2108     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2109         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
2110         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
2111         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
2112     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2113         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
2114         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
2115         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
2116     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2117         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
2118         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
2119 - testbed32:
2120     - ring1 10GE-ports x710-4p10GE on SUTs:
2121         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
2122         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
2123         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
2124     - ring2 10GE-ports x710-4p10GE on SUT:
2125         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
2126         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
2127         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
2128     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
2129         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
2130         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
2131         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
2132     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
2133         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
2134         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
2135         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
2136     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
2137         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
2138         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
2139 ```
2140
2141 #### 3-Node-Rangeley Wiring (3n-rng) TODO
2142
2143 ```
2144 To be completed.
2145 ```
2146
2147 #### 3-Node-Taishan Wiring (3n-tsh) PROD
2148
2149 ```
2150 - testbed33:
2151     - ring1 10GE-ports x520-2p10GE on SUTs:
2152         - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
2153         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
2154         - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
2155     - ring2 25GE-ports cx4-2p25GE on SUTs:
2156         - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
2157         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
2158         - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
2159 ```
2160
2161 #### 3-Node-Altra Wiring (3n-alt) TBD
2162
2163 ```
2164 - testbed34:
2165     - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
2166         - s64-t34-tg1-cn/p2 - s62-t34-sut1-cn/p2.
2167         - s62-t34-sut1-cn/p1 - s63-t34-sut2-cn/p2.
2168         - s63-t34-sut2-cn/p1 - s64-t34-tg1-cn/p1.
2169     - ring2 100GE-ports ConnectX5-2p100GE on SUTs:
2170         - s64-t34-tg1-ck/p2 - s62-t34-sut1-ck/p2.
2171         - s62-t34-sut1-ck/p1 - s63-t34-sut2-ckp2.
2172         - s63-t34-sut2-ck/p1 - s64-t34-tg1-ck/p1.
2173 ```
2174
2175 #### 3-Node-Denverton Wiring (3n-dnv) PROD
2176
2177 ```
2178 - testbed35:
2179     - ring1 10GE-ports x553 copper port on SUTs:
2180         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
2181         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
2182         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
2183     - ring2 10GE-ports x553 fiber port on SUTs:
2184         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
2185         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
2186         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
2187 ```
2188
2189 #### 3-Node-Icelake Wiring (3n-icx) PROD
2190
2191 ```
2192 - testbed37:
2193     - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2194         - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
2195         - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
2196         - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
2197     - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2198         - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
2199         - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
2200         - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
2201         - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
2202         - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
2203         - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
2204     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2205         - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
2206         - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
2207         - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
2208 - testbed38:
2209     - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
2210         - s70-t38-tg1-c2/p1 to s68-t38-sut1-c2/p1.
2211         - s68-t38-sut1-c2/p2 to s69-t38-sut2-c2/p2.
2212         - s69-t38-sut2-c2/p1 to s70-t38-tg1-c2/p2.
2213     - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
2214         - s70-t38-tg1-c4/p1 to s68-t38-sut1-c4/p1.
2215         - s68-t38-sut1-c4/p2 to s69-t38-sut2-c4/p2.
2216         - s69-t38-sut2-c4/p1 to s70-t38-tg1-c4/p2.
2217         - s70-t38-tg1-c4/p3 to s68-t38-sut1-c4/p3.
2218         - s68-t38-sut1-c4/p4 to s69-t38-sut2-c4/p4.
2219         - s69-t38-sut2-c4/p3 to s70-t38-tg1-c4/p4.
2220     - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
2221         - s70-t38-tg1-c9/p1 to s68-t38-sut1-c9/p1.
2222         - s68-t38-sut1-c9/p2 to s69-t38-sut2-c9/p2.
2223         - s69-t38-sut2-c9/p1 to s70-t38-tg1-c9/p2.
2224 ```
2225
2226 ## Inventory
2227
2228 ### Appliances
2229
2230 ```
2231 1. Ixia PerfectStorm One Appliance
2232     - 1 * PS10GE4NG
2233         - Chassis: PS10GE4NG.
2234         - Motherboard: SuperMicro X11DPG-QT.
2235         - Processors: Quad-Core, Intel Processor.
2236         - HW accelerators: FPGA offload.
2237         - RAM Memory: 64GB.
2238         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
2239         - Physical Interfaces: 4 * 10GE SFP+.
2240         - Operating System: Native IxOS.
2241 ```
2242
2243 ### Arm Servers
2244
2245 ```
2246 1. Arm Cortex A-72 servers
2247     - 2 * ThunderX2 (VPP Device)
2248         - Chassis: GIGABYTE Rack Mount
2249         - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
2250         - RAM Memory: 16* 16GB DIMM
2251         - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
2252     - 1 * ThunderX2 (Performance)
2253         - Chassis: GIGABYTE Rack Mount
2254         - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
2255         - RAM Memory: 4* 32GB RDIMM
2256         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
2257     - 2 * Huawei TaiShan 2280.
2258         - Chassis: Huawei TaiShan 2280.
2259         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
2260         - RAM Memory: 8* 16GB DDR4-2400MT/s.
2261         - Disks: 1* 4TB SATA HDD.
2262     - 2 * Ampere Altra
2263         - Chassis: TBD
2264         - Processors: TBD
2265         - RAM Memory: TBD
2266         - Disks: TBD
2267 ```
2268
2269 ### Xeon and Atom Servers
2270
2271 ```
2272 1. Intel Xeon servers:
2273     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
2274         - Chassis: SuperMicro SYS-7049GP-TRT.
2275         - Motherboard: SuperMicro X11DPG-QT.
2276         - Processors: 2* Intel Platinum 8180 2.5 GHz.
2277         - RAM Memory: 16* 16GB DDR4-2666MHz.
2278         - Disks: 2* 1.6TB 6G SATA SSD.
2279 2. Intel Atom servers with Rangely processors.
2280     - 3 * Netgate XG-2758-1u
2281         - Chassis: Netgate XG-2758-1u
2282         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
2283         - RAM Memory: 16GB ECC
2284         - Disks: 150 GB
2285 ```
2286
2287 ### Network Interface Cards
2288
2289 ```
2290 1. 10GE NICs
2291     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
2292     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
2293     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
2294 2. 25GE NICs
2295     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
2296 3. 40GE NICs
2297     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
2298 4. 100GE NICs
2299     - 4 * mcx556a-edat NICs (not on site yet, in transit)
2300 ```
2301
2302 ### Pluggables and Cables
2303
2304 Pluggables:
2305
2306 ```
2307 1. 10GE SFP+
2308     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
2309     - 80 * 10G SR optic (generic, "Intel" compatible branded)
2310 2. 25GE SFP28
2311     - None
2312 3. 40GE QSFP+
2313     - None
2314 4. 100GE
2315     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
2316 ```
2317
2318 Standalone cables:
2319
2320 ```
2321 1. 10GE
2322     - None
2323 2. 25GE
2324     - None
2325 3. 40GE QSFP+
2326     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
2327 4. 100GE
2328     - None
2329 ```
2330
2331 ### Other Parts