Infra: Ansible Nomad III
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16    1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19    1. [Requirements](#requirements)
20    1. [Addressing](#addressing)
21    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24    1. [Server Types](#server-types)
25    1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29       1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30       1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32       1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34       1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35       1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38       1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39       1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40    1. [Per Testbed Wiring](#per-testbed-wiring)
41       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42       1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43       1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45       1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47       1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51       1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52       1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54    1. [Appliances](#appliances)
55    1. [Arm Servers](#arm-servers)
56    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57    1. [Network Interface Cards](#network-interface-cards)
58    1. [Pluggables and Cables](#pluggables-and-cables)
59    1. [Other Parts](#other-parts)
60
61 ## Purpose
62
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
65
66 ## Testbeds Overview
67
68 ### Summary List
69
70 ```
71  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72  1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0
73  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0
74  3. 1-Node-Thunderx2   dev    tx2   na    1    1    0    0    0    0    0    0    1    0    0
75  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0
76  5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0
77  6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0
78  7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0
79  8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0
80  9. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0
81 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0
82 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0
83 12. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0
84 13. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2
85 14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0
86                                  Totals: 22   35   18   12   19    1    2    3    1    2    2
87 ```
88
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
90
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
94
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
96
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
100
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
102
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
105
106 Used for FD.io VPP_Device functional driver tests.
107
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
109
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
114
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
116
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
121
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
123
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
128
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
130
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
135
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
137
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
142
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
144
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
148
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
150
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
155
156 ### 3-Node-MACCHIATObin Arm Marvell
157
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
162
163 ### 3-Node-Rangeley Atom Testbeds
164
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
169
170 ## Server Management
171
172 ### Requirements
173
174 For management purposes, each server must have following two ports
175 connected to the management network:
176
177 ```
178 - 1GE IPMI port
179   - IPMI - Intelligent Platform Management Interface.
180   - Required for access to embedded server management with WebUI, CLI,
181     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183   - hostOS management port for general system management.
184 ```
185
186 ### Addressing
187
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
190
191 ```
192 1. LOM (IPMI) VLAN:
193     - Subnet: 10.30.50.0/24
194     - Gateway: 10.30.50.1
195     - Broadcast: 10.30.50.255
196     - DNS1: 199.204.44.24
197     - DNS2: 199.204.47.54
198 2. Management Vlan:
199     - Subnet: 10.30.51.0/24
200     - Gateway: 10.30.51.1
201     - Broadcast: 10.30.51.255
202     - DNS1: 199.204.44.24
203     - DNS2: 199.204.47.54
204 ```
205
206 To access these hosts, VPN connection is required.
207
208 ### LOM (IPMI) VLAN IP Addresses
209
210 Name         | Comment
211 ------------ | -------
212 10.30.50.0   | network
213 10.30.51.1   | Router
214 10.30.50.2   | LF Reserved
215 10.30.50.3   | LF Reserved
216 10.30.50.4   | LF Reserved
217 10.30.50.5   | LF Reserved
218 10.30.50.6   | LF Reserved
219 10.30.50.7   | LF Reserved
220 10.30.50.8   | LF Reserved
221 10.30.50.9   | LF Reserved
222 10.30.50.10  | LF Reserved
223 10.30.50.11  | LF Reserved
224 10.30.50.12  | LF Reserved
225 10.30.50.13  | LF Reserved
226 10.30.50.14  | LF Reserved
227 10.30.50.15  | LF Reserved
228 10.30.50.16  | t1-tg1
229 10.30.50.17  | t1-sut1
230 10.30.50.18  | t1-sut2
231 10.30.50.20  | t2-tg1
232 10.30.50.21  | t2-sut1
233 10.30.50.22  | t2-sut2
234 10.30.50.24  | t3-tg1
235 10.30.50.25  | t3-sut1
236 10.30.50.26  | t3-sut-2
237 10.30.50.28  | s41-nomad
238 10.30.50.29  | s39-nomad
239 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
240 10.30.50.30  | s40-nomad
241 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
242 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
243 10.30.50.32  | s42-nomad (formerly nomad1)
244 10.30.50.33  | s43-nomad (formerly nomad2)
245 10.30.50.36  | s17-t33-sut1
246 10.30.50.37  | s18-t33-sut2
247 10.30.50.41  | s3-t21-sut1
248 10.30.50.42  | s4-t21-tg1
249 10.30.50.43  | s11-t31-sut1
250 10.30.50.44  | s12-t31-sut2
251 10.30.50.45  | s13-t31-tg1
252 10.30.50.46  | s19-t33t34-tg1
253 10.30.50.47  | s1-t11-sut1
254 10.30.50.48  | s2-t12-sut1
255 10.30.50.49  | s5-t22-sut1
256 10.30.50.50  | s6-t22-tg1
257 10.30.50.51  | s7-t23-sut1
258 10.30.50.52  | s8-t23-tg1
259 10.30.50.53  | s9-t24-sut1
260 10.30.50.54  | s10-t24-tg1
261 10.30.50.55  | s14-t32-sut1
262 10.30.50.56  | s15-t32-sut2
263 10.30.50.57  | s16-t32-tg1
264 10.30.50.58  | s25-t25-sut1
265 10.30.50.59  | s26-t25-tg1
266 10.30.50.69  | s27-t13-sut
267 10.30.50.255 | Broadcast
268 n/a          | s20-t34-sut1
269 n/a          | s21-t34-sut2
270 10.30.55.0   | network
271 10.30.55.1   | Router
272 10.30.55.10  | s28-t26t35-tg1
273 10.30.55.11  | s29-t26-sut1
274 10.30.55.12  | s30-t35-sut1
275 10.30.55.13  | s31-t35-sut2
276 10.30.55.14  | s46-nomad (formerly server-type-c4-1)
277 10.30.55.15  | s47-nomad (formerly server-type-c4-2)
278 10.30.55.17  | s32-t14-sut1
279 10.30.55.18  | s33-t27-sut1
280 10.30.55.19  | s34-t27-tg1
281 10.30.55.20  | s35-t28-sut1
282 10.30.55.21  | s36-t28-tg1
283 10.30.55.22  | s37-t29-sut1
284 10.30.55.23  | s38-t29-tg1
285 10.30.55.255 | Broadcast
286
287 ### Management VLAN IP Addresses
288
289 Name                      | Comment
290 ------------------------- | -------
291 10.30.51.0                | network
292 10.30.51.1                | Router
293 10.30.51.2                | LF Reserved
294 10.30.51.3                | LF Reserved
295 10.30.51.4                | LF Reserved
296 10.30.51.5                | LF Reserved
297 10.30.51.6                | LF Reserved
298 10.30.51.7                | LF Reserved
299 10.30.51.8                | LF Reserved
300 10.30.51.9                | s22-t35-sut1 (netgate-1)
301 10.30.51.10               | s23-t35-sut2 (netgate-2)
302 10.30.51.11               | s24-t35-sut3 (netgate-3)
303 10.30.51.12               | softiron-1
304 10.30.51.13               | s44-nomad (formerly nomad1arm)
305 10.30.51.14               | s45-nomad (formerly nomad2arm)
306 10.30.51.15               | LF Reserved
307 10.30.51.16               | t1-tg1
308 10.30.51.17               | t1-sut1
309 10.30.51.18               | t1-sut2
310 10.30.51.20               | t2-tg1
311 10.30.51.21               | t2-sut1
312 10.30.51.22               | t2-sut2
313 10.30.51.24               | t3-tg1
314 10.30.51.25               | t3-sut1
315 10.30.51.26               | t3-sut-2
316 10.30.51.28               | s41-nomad
317 10.30.51.29               | s39-nomad
318 10.30.51.30               | s40-nomad
319 10.30.51.32               | s42-nomad (formerly nomad1)
320 10.30.51.33               | s43-nomad (formerly nomad2)
321 10.30.51.36               | s17-t33-sut1
322 10.30.51.37               | s18-t33-sut2
323 10.30.51.41               | s20-t34-sut1
324 10.30.51.42               | s21-t34-sut2
325 10.30.51.44               | s3-t21-sut1
326 10.30.51.45               | s4-t21-tg1
327 10.30.51.46               | s11-t31-sut1
328 10.30.51.47               | s12-t31-sut2
329 10.30.51.48               | s13-t31-tg1
330 10.30.51.49               | s19-t33t34-tg1
331 10.30.51.50               | s1-t11-sut1
332 10.30.51.51               | s2-t12-sut1
333 10.30.51.52               | s5-t22-sut1
334 10.30.51.53               | s6-t22-tg1
335 10.30.51.54               | s7-t23-sut1
336 10.30.51.55               | s8-t23-tg1
337 10.30.51.56               | s9-t24-sut1
338 10.30.51.57               | s10-t24-tg1
339 10.30.51.58               | s14-t32-sut1
340 10.30.51.59               | s15-t32-sut2
341 10.30.51.60               | s16-t32-tg1
342 10.30.51.61               | s25-t25-sut1
343 10.30.51.62               | s26-t25-tg1
344 10.30.51.69               | s27-t13-sut1
345 10.30.51.70-10.30.51.105  | FREE
346 10.30.51.106-10.30.51.180 | FREE
347 10.30.51.181-10.30.51.254 | FREE
348 10.30.51.255              | Broadcast
349 10.32.8.0                 | network
350 10.32.8.1                 | Router
351 10.32.8.10                | s28-t26t35-tg1
352 10.32.8.11                | s29-t26-sut1
353 10.32.8.12                | s30-t35-sut1
354 10.32.8.13                | s31-t35-sut2
355 10.32.8.14                | s46-nomad (formerly server-type-c4-1)
356 10.32.8.15                | s47-nomad (formerly server-type-c4-2)
357 10.32.8.17                | s32-t14-sut1
358 10.32.8.18                | s33-t27-sut1
359 10.32.8.19                | s34-t27-tg1
360 10.32.8.20                | s35-t28-sut1
361 10.32.8.21                | s36-t28-tg1
362 10.32.8.22                | s37-t29-sut1
363 10.32.8.23                | s38-t29-tg1
364 10.32.8.255               | Broadcast
365
366 ## Server Specifications
367
368 ### Server Types
369
370 FD.io CSIT lab contains following server types:
371 ```
372 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
373     - Quantity: 6 servers.
374     - Physical connectivity:
375         - CIMC and host management ports.
376         - NIC ports connected in 3-node topologies.
377     - Main HW configuration:
378         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
379         - Processors: 2* E5-2699v3 2.3 GHz.
380         - RAM Memory: 16* 32GB DDR4-2133MHz.
381         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
382     - NICs configuration:
383         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
384             - PCIe Slot1: Cisco VIC 1385 2p40GE.
385             - PCIe Slot2: Intel NIC x520 2p10GE.
386             - PCIe Slot3: empty.
387         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
388             - PCIe Slot4: Intel NIC xl710 2p40GE.
389             - PCIe Slot5: Intel NIC x710 2p10GE.
390             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
391         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
392 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
393     - Quantity: 3 servers.
394     - Physical connectivity:
395         - CIMC and host management ports.
396         - NIC ports connected in 3-node topologies.
397     - Main HW configuration:
398         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
399         - Processors: 2* E5-2699v3 2.3 GHz.
400         - RAM Memory: 16* 32GB DDR4-2133MHz.
401         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
402     - NICs configuration:
403         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
404             - PCIe Slot1: Intel NIC xl710 2p40GE.
405             - PCIe Slot2: Intel NIC x710 2p10GE.
406             - PCIe Slot3: Intel NIC x710 2p10GE.
407         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
408             - PCIe Slot4: Intel NIC xl710 2p40GE.
409             - PCIe Slot5: Intel NIC x710 2p10GE.
410             - PCIe Slot6: Intel NIC x710 2p10GE.
411         - MLOM slot: empty.
412 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
413     - Quantity: 3 servers.
414     - Physical connectivity:
415         - CIMC and host management ports.
416         - no NIC ports, standalone setup.
417     - Main HW configuration:
418         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
419         - Processors: 2* E5-2699v3 2.3 GHz.
420         - RAM Memory: 16* 32GB DDR4-2133MHz.
421         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
422     - NICs configuration:
423         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
424             - no cards.
425         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
426             - no cards.
427         - MLOM slot: empty.
428 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
429     - Quantity: ---
430     - Physical connectivity:
431         - IPMI and host management ports.
432         - NIC ports connected into 2-node and 3-node topologies.
433     - Main HW configuration:
434         - Chassis: SuperMicro SYS-7049GP-TRT.
435         - Motherboard: SuperMicro X11DPG-QT.
436         - Processors: 2* Intel Platinum 8180 2.5 GHz.
437         - RAM Memory: 16* 16GB DDR4-2666MHz.
438         - Disks: 2* 1.6TB 6G SATA SSD.
439     - NICs configuration:
440         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
441             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
442             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
443             - PCIe Slot9 5e:00.xx: empty.
444         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
445             - PCIe Slot6 86:00.xx: empty.
446             - PCIe Slot8 af:00.xx: empty.
447             - PCIe Slot10 d8:00.xx: empty.
448 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
449     - Quantity: ---
450     - Physical connectivity:
451         - IPMI and host management ports.
452         - NIC ports connected into 2-node and 3-node topologies.
453     - Main HW configuration:
454         - Chassis: SuperMicro SYS-7049GP-TRT.
455         - Motherboard: SuperMicro X11DPG-QT.
456         - Processors: 2* Intel Platinum 8180 2.5 GHz.
457         - RAM Memory: 16* 16GB DDR4-2666MHz.
458         - Disks: 2* 1.6TB 6G SATA SSD.
459     - NICs configuration:
460         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
461             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
462             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
463             - PCIe Slot9 5e:00.xx: empty.
464         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
465             - PCIe Slot6 86:00.xx: empty.
466             - PCIe Slot8 af:00.xx: empty.
467             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
468 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
469     - Quantity: 2
470     - Physical connectivity:
471         - IPMI(?) and host management ports.
472         - NIC ports connected into 3-node topology.
473     - Main HW configuration:
474         - Chassis: Huawei TaiShan 2280.
475         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
476         - RAM Memory: 8* 16GB DDR4-2400MT/s
477         - Disks: 1* 4TB SATA HDD
478     - NICs configuration:
479         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
480         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
481 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
482     - Quantity: 3
483     - Physical connectivity:
484         - Host management ports.
485         - NIC ports connected into 2-node and 3-node topologies.
486     - Main HW configuration:
487         - Chassis: MACCHIATObin.
488         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
489         - RAM Memory: 1* 16GB DDR4
490         - Disks: 1* 128GB(?) SATA SDD
491     - NICs configuration:
492         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
493 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
494     - Quantity: TBD based on testbed allocation.
495     - Physical connectivity:
496         - Management: serial Port (usb) for console
497         - NIC ports connected into 2-node.
498     - Main HW configuration:
499         - Chassis: Netgate XG-2758-1u
500         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
501         - RAM Memory: 16GB ECC
502         - Disks: 150 GB
503     - NICs configuration:
504         - 2x 10Gb Intel 82599ES
505         - 4x 1GB Intel I354
506 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
507     - Quantity: 2.
508     - Physical connectivity:
509         - IPMI and host management ports.
510         - NIC ports connected into 2-node and 3-node topologies.
511     - Main HW configuration:
512         - Chassis: SuperMicro SYS-7049GP-TRT.
513         - Motherboard: SuperMicro X11DPG-QT.
514         - Processors: 2* Intel Platinum 8180 2.5 GHz.
515         - RAM Memory: 16* 16GB DDR4-2666MHz.
516         - Disks: 2* 1.6TB 6G SATA SSD.
517     - NICs configuration:
518         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
519             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
520             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
521             - PCIe Slot9 5e:00.xx: empty.
522         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
523             - PCIe Slot6 86:00.xx: empty.
524             - PCIe Slot8 af:00.xx: empty.
525             - PCIe Slot10 d8:00.xx: empty.
526 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
527     - Quantity: 1.
528     - Physical connectivity:
529         - Host management interface: 10/100/1000-BaseT.
530         - 8-port 10GE SFP+ integrated NIC.
531     - Main HW configuration:
532         - Chassis: PS10GE4NG.
533         - Motherboard: SuperMicro X11DPG-QT.
534         - Processors: Quad-Core, Intel Processor.
535         - HW accelerators: FPGA offload.
536         - RAM Memory: 64GB.
537         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
538         - Physical Interfaces: 4 * 10GE SFP+.
539         - Operating System: Native IxOS.
540     - Interface configuration:
541         - Port-1: 10GE SFP+.
542         - Port-2: 10GE SFP+.
543         - Port-3: 10GE SFP+.
544         - Port-4: 10GE SFP+.
545 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
546     - Quantity: 1.
547     - Physical connectivity:
548         - IPMI and host management ports.
549         - NIC ports.
550     - Main HW configuration:
551         - Chassis: SuperMicro SYS-7049GP-TRT.
552         - Motherboard: SuperMicro X11DPG-QT.
553         - Processors: 2* Intel Platinum 8180 2.5 GHz.
554         - RAM Memory: 16* 16GB DDR4-2666MHz.
555         - Disks: 2* 1.6TB 6G SATA SSD.
556     - NICs configuration:
557         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
558             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
559             - PCIe Slot4 3b:00.xx: empty.
560             - PCIe Slot9 5e:00.xx: empty.
561         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
562             - PCIe Slot6 86:00.xx: empty.
563             - PCIe Slot8 af:00.xx: empty.
564             - PCIe Slot10 d8:00.xx: empty.
565 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
566     - Quantity: 1
567     - Physical connectivity:
568         - IPMI and host management ports.
569         - NIC ports connected into 1-node topologies.
570     - Main HW configuration:
571         - Chassis: Gigabyte R181-T90 1U
572         - Motheboard: MT91-FS1
573         - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
574         - RAM Memory: 4* 32GB RDIMM
575         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
576     - NICs configuration:
577         - Numa0:
578             - PCIe Slot1 05:00.xx: XL710-QDA2.
579             - PCIe Slot3 08:00.xx: XL710-QDA2.
580         - Numa1:
581             - PCIe Slot6 85:00.xx: XL710-QDA2.
582 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
583     - Quantity: 4
584     - Physical connectivity:
585         - IPMI and host management ports.
586         - NIC ports.
587     - Main HW configuration:
588         - Chassis: SuperMicro SYS-E300-9A
589         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
590         - RAM Memory: 32GB ECC
591         - Disks: 480 GB
592     - NICs configuration:
593         - 2x 10Gb Intel x553 fiber ports
594         - 2x 10Gb Intel x553 copper ports
595         - 4x 1GB Intel I350 ports
596
597 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
598     - Quantity: 1.
599     - Physical connectivity:
600         - IPMI and host management ports.
601         - NIC ports connected into 1-node testbed topologies.
602     - Main HW configuration:
603         - Chassis: SuperMicro SYS-7049GP-TRT.
604         - Motherboard: SuperMicro X11DPG-QT.
605         - Processors: 2* Intel Platinum 8280 2.7 GHz.
606         - RAM Memory: 12* 16GB DDR4-2933.
607         - Disks: 2* 1.92TB SATA SSD.
608     - NICs configuration:
609         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
610             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
611             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
612             - PCIe Slot9 5e:00.xx: empty.
613         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
614             - PCIe Slot6 86:00.xx: empty.
615             - PCIe Slot8 af:00.xx: empty.
616             - PCIe Slot10 d8:00.xx: empty.
617
618 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
619     - Quantity: 3
620     - Physical connectivity:
621         - IPMI and host management ports.
622         - NIC ports connected into 2-node testbed topologies.
623     - Main HW configuration:
624         - Chassis: SuperMicro SYS-7049GP-TRT.
625         - Motherboard: SuperMicro X11DPG-QT.
626         - Processors: 2* Intel Gold 6252N 2.3 GHz.
627         - RAM Memory: 12* 16GB DDR4-2933.
628         - Disks: 2* 1.92TB SATA SSD.
629     - NICs configuration:
630         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
631             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
632             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
633             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
634               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
635         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
636             - PCIe Slot6 86:00.xx: empty.
637             - PCIe Slot8 af:00.xx: empty.
638             - PCIe Slot10 d8:00.xx: empty.
639 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
640     - Quantity: 3.
641     - Physical connectivity:
642         - IPMI and host management ports.
643         - NIC ports connected into 2-node testbed topologies.
644     - Main HW configuration:
645         - Chassis: SuperMicro SYS-7049GP-TRT.
646         - Motherboard: SuperMicro X11DPG-QT.
647         - Processors: 2* Intel Platinum 8280 2.7 GHz.
648         - RAM Memory: 12* 16GB DDR4-2933.
649         - Disks: 2* 1.92TB SATA SSD.
650     - NICs configuration:
651         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
652             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
653             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
654             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
655               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
656         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
657             - PCIe Slot6 86:00.xx: empty.
658             - PCIe Slot8 af:00.xx: empty.
659             - PCIe Slot10 d8:00.xx: empty.
660
661 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
662     - Quantity: 3.
663     - Physical connectivity:
664         - CIMC and host management ports.
665         - no NIC ports, standalone setup.
666     - Main HW configuration:
667         - Chassis: SuperMicro 1029P-WTRT.
668         - Motherboard: SuperMicro X11DDW-NT.
669         - Processors: 2* Intel Platinum 8280 2.7 GHz.
670         - RAM Memory: 12* 16GB DDR4-2933.
671         - Disks: 4* 1.92TB SATA SSD.
672     - NICs configuration:
673         - Numa0:
674             - no cards.
675         - Numa1:
676             - no cards.
677 ```
678
679 ### Naming Convention
680
681 Following naming convention is used within this page to specify physical
682 connectivity and wiring across defined CSIT testbeds:
683
684 ```
685 - testbedname: testbedN.
686 - hostname:
687     - traffic-generator: tN-tgW.
688     - system-under-testX: tN-sutX.
689 - portnames:
690     - tN-tgW-cY/pZ.
691     - tN-sutX-cY/pZ.
692 - where:
693     - N - testbed number.
694     - tgW - server acts as traffic-generator with W index.
695     - sutX - server acts as system-under-test with X index.
696     - Y - PCIe slot number denoting a NIC card number within the host.
697     - Z - port number on the NIC card.
698 ```
699
700 ## Testbeds Configuration
701
702 ### Per Testbed Server Allocation and Naming
703
704 #### 1-Node-Skylake Servers (1n-skx) PROD
705
706 ```
707 - SUT [Server-Type-B6]:
708     - testbedname: testbed11.
709     - hostname: s1-t11-sut1.
710     - IPMI IP: 10.30.50.47
711     - Host IP: 10.30.51.50
712     - portnames:
713         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
714         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
715         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
716         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
717         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
718         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
719         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
720         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
721 - SUT [Server-Type-B6]:
722     - testbedname: testbed12.
723     - hostname: s2-t12-sut1.
724     - IPMI IP: 10.30.50.48
725     - Host IP: 10.30.51.51
726     - portnames:
727         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
728         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
729         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
730         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
731         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
732         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
733         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
734         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
735 ```
736
737 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
738
739 ```
740 - SUT [Server-Type-B9]:
741     - testbedname: testbed13.
742     - hostname: s27-t13-sut1.
743     - IPMI IP: 10.30.50.69
744     - Host IP: 10.30.51.69
745     - portnames:
746         - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
747         - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
748         - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
749         - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
750         - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
751         - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
752 ```
753
754 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
755
756 ```
757 - SUT [Server-Type-C1]:
758     - testbedname: testbed11.
759     - hostname: s32-t14-sut1.
760     - IPMI IP: 10.30.55.17
761     - Host IP: 10.32.8.17
762     - portnames:
763         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
764         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
765         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
766         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
767         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
768         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
769         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
770         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
771 ```
772
773 #### 2-Node-Skylake Servers (2n-skx) PROD
774
775 ```
776 - SUT [Server-Type-B1]:
777     - testbedname: testbed21.
778     - hostname: s3-t21-sut1.
779     - IPMI IP: 10.30.50.41
780     - Host IP: 10.30.51.44
781     - portnames:
782         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
783         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
784         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
785         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
786         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
787         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
788 - TG [Server-Type-B2]:
789     - testbedname: testbed21.
790     - hostname: s4-t21-tg1.
791     - IPMI IP: 10.30.50.42
792     - Host IP: 10.30.51.45
793     - portnames:
794         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
795         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
796         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
797         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
798         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
799         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
800 - SUT [Server-Type-B1]:
801     - testbedname: testbed22.
802     - hostname: s5-t22-sut1.
803     - IPMI IP: 10.30.50.49
804     - Host IP: 10.30.51.52
805     - portnames:
806         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
807         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
808         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
809         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
810         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
811         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
812 - TG [Server-Type-B2]:
813     - testbedname: testbed22.
814     - hostname: s6-t22-tg1.
815     - IPMI IP: 10.30.50.50
816     - Host IP: 10.30.51.53
817     - portnames:
818         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
819         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
820         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
821         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
822         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
823         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
824 - SUT [Server-Type-B1]:
825     - testbedname: testbed23.
826     - hostname: s7-t23-sut1.
827     - IPMI IP: 10.30.50.51
828     - Host IP: 10.30.51.54
829     - portnames:
830         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
831         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
832         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
833         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
834         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
835         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
836 - TG [Server-Type-B2]:
837     - testbedname: testbed23.
838     - hostname: s8-t23-tg1.
839     - IPMI IP: 10.30.50.52
840     - Host IP: 10.30.51.55
841     - portnames:
842         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
843         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
844         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
845         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
846         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
847         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
848 - SUT [Server-Type-B1]:
849     - testbedname: testbed24.
850     - hostname: s9-t24-sut1.
851     - IPMI IP: 10.30.50.53
852     - Host IP: 10.30.51.56
853     - portnames:
854         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
855         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
856         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
857         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
858         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
859         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
860 - TG [Server-Type-B2]:
861     - testbedname: testbed24.
862     - hostname: s10-t24-tg1.
863     - IPMI IP: 10.30.50.54
864     - Host IP: 10.30.51.57
865     - portnames:
866         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
867         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
868         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
869         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
870         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
871         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
872 ```
873
874 #### 2-Node-Denverton Servers (2n-dnv) WIP
875
876 Note: ServerB28 (TG) is shared between testbed26 & testbed35
877
878 ```
879 - TG [Server-Type-B2]:
880     - testbednames: testbed26 and testbed35.
881     - hostname: s28-t26t35-tg1.
882     - IPMI IP: 10.30.55.10
883     - Host IP: 10.32.8.10
884     - portnames:
885         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
886         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
887         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
888         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
889         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
890         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
891         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
892         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
893         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
894         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
895         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
896         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
897 - SUT [Server-Type-B10]:
898     - testbednames: testbed26.
899     - hostname: s29-t26-sut1.
900     - IPMI IP: 10.30.55.11
901     - Host IP: 10.32.8.11
902     - portnames:
903         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
904         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
905         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
906         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
907 ```
908
909 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
910
911 ```
912 - SUT [Server-Type-B8]:
913     - testbedname: testbed25.
914     - hostname: s25-t25-sut1.
915     - IPMI IP: 10.30.50.58
916     - Host IP: 10.30.51.61
917     - portnames:
918         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
919         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
920         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
921         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
922 - TG [Server-Type-B7]:
923     - testbedname: testbed25.
924     - hostname: s26-t25-tg1.
925     - IPMI IP: 10.30.50.59
926     - Host IP: 10.30.51.62
927     - portnames:
928         - s26-t25-tg1-p1 - 10GE-port1.
929         - s26-t25-tg1-p2 - 10GE-port2.
930         - s26-t25-tg1-p3 - 10GE-port3.
931         - s26-t25-tg1-p4 - 10GE-port4.
932 ```
933
934 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
935
936 ```
937 - SUT [Server-Type-C2]:
938     - testbedname: testbed27.
939     - hostname: s33-t27-sut1.
940     - IPMI IP: 10.30.55.18
941     - Host IP: 10.32.8.18
942     - portnames:
943         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
944         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
945         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
946         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
947         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
948         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
949         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
950         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
951 - TG [Server-Type-C3]:
952     - testbedname: testbed27.
953     - hostname: s34-t27-tg1.
954     - IPMI IP: 10.30.55.19
955     - Host IP: 10.32.8.19
956     - portnames:
957         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
958         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
959         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
960         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
961         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
962         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
963         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
964         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
965 - SUT [Server-Type-C2]:
966     - testbedname: testbed28.
967     - hostname: s35-t28-sut1.
968     - IPMI IP: 10.30.55.20
969     - Host IP: 10.32.8.20
970     - portnames:
971         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
972         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
973         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
974         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
975         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
976         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
977         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
978         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
979 - TG [Server-Type-C3]:
980     - testbedname: testbed28.
981     - hostname: s36-t28-tg1.
982     - IPMI IP: 10.30.55.21
983     - Host IP: 10.32.8.21
984     - portnames:
985         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
986         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
987         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
988         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
989         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
990         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
991         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
992         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
993 - SUT [Server-Type-C2]:
994     - testbedname: testbed29.
995     - hostname: s37-t29-sut1.
996     - IPMI IP: 10.30.55.22
997     - Host IP: 10.32.8.22
998     - portnames:
999         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1000         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1001         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1002         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1003         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1004         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1005         - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1006         - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1007 - TG [Server-Type-C3]:
1008     - testbedname: testbed29.
1009     - hostname: s38-t29-tg1.
1010     - IPMI IP: 10.30.55.23
1011     - Host IP: 10.32.8.23
1012     - portnames:
1013         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1014         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1015         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1016         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1017         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1018         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1019         - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1020         - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1021 ```
1022
1023 #### 3-Node-Haswell Servers (3n-hsw) PROD
1024
1025 ```
1026  1. SUT [Server-Type-A1]:
1027     - testbedname: testbed1.
1028     - hostname: t1-sut1.
1029     - CIMC IP: 10.30.50.17
1030     - Host IP: 10.30.51.17
1031     - portnames:
1032         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1033         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1034         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1035         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1036         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1037         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1038         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1039         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1040         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1041         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1042  2. SUT [Server-Type-A1]:
1043     - testbedname: testbed1.
1044     - hostname: t1-sut2.
1045     - CIMC IP: 10.30.50.18
1046     - Host IP: 10.30.51.18
1047     - portnames:
1048         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1049         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1050         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1051         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1052         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1053         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1054         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1055         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1056         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1057         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1058  3. TG [Server-Type-A2]:
1059     - testbedname: testbed1.
1060     - hostname: t1-tg1.
1061     - CIMC IP: 10.30.50.16
1062     - Host IP: 10.30.51.16
1063     - portnames:
1064         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1065         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1066         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1067         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1068         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1069         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1070         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1071         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1072         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1073         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1074         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1075         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1076  4. SUT [Server-Type-A1]:
1077     - testbedname: testbed2.
1078     - hostname: t2-sut1.
1079     - CIMC IP: 10.30.50.21
1080     - Host IP: 10.30.51.21
1081     - portnames:
1082         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1083         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1084         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1085         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1086         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1087         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1088         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1089         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1090         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1091         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1092  5. SUT [Server-Type-A1]:
1093     - testbedname: testbed2.
1094     - hostname: t2-sut2.
1095     - CIMC IP: 10.30.50.22
1096     - Host IP: 10.30.51.22
1097     - portnames:
1098         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1099         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1100         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1101         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1102         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1103         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1104         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1105         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1106         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1107         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1108  6. TG [Server-Type-A2]:
1109     - testbedname: testbed2.
1110     - hostname: t2-tg1.
1111     - CIMC IP: 10.30.50.20
1112     - Host IP: 10.30.51.20
1113     - portnames:
1114         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1115         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1116         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1117         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1118         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1119         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1120         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1121         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1122         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1123         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1124         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1125         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1126  7. SUT [Server-Type-A1]:
1127     - testbedname: testbed3.
1128     - hostname: t3-sut1.
1129     - CIMC IP: 10.30.50.25
1130     - Host IP: 10.30.51.25
1131     - portnames:
1132         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1133         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1134         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1135         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1136         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1137         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1138         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1139         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1140         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1141         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1142  8. SUT [Server-Type-A1]:
1143     - testbedname: testbed3.
1144     - hostname: t3-sut2.
1145     - CIMC IP: 10.30.50.26
1146     - Host IP: 10.30.51.26
1147     - portnames:
1148         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1149         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1150         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1151         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1152         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1153         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1154         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1155         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1156         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1157         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1158  9. TG [Server-Type-A2]:
1159     - testbedname: testbed3.
1160     - hostname: t3-tg1.
1161     - CIMC IP: 10.30.50.24
1162     - Host IP: 10.30.51.24
1163     - portnames:
1164         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1165         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1166         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1167         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1168         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1169         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1170         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1171         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1172         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1173         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1174         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1175         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1176 ```
1177
1178 #### 3-Node-Skylake Servers (3n-skx) PROD
1179
1180 ```
1181 - ServerB11 [Server-Type-B1]:
1182     - testbedname: testbed31.
1183     - hostname: s11-t31-sut1.
1184     - IPMI IP: 10.30.50.43
1185     - Host IP: 10.30.51.46
1186     - portnames:
1187         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1188         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1189         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1190         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1191         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1192         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1193         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1194         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1195 - ServerB12 [Server-Type-B1]:
1196     - testbedname: testbed31.
1197     - hostname: s12-t31-sut2.
1198     - IPMI IP: 10.30.50.44
1199     - Host IP: 10.30.51.47
1200     - portnames:
1201         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1202         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1203         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1204         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1205         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1206         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1207         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1208         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1209 - ServerB13 [Server-Type-B2]:
1210     - testbedname: testbed31.
1211     - hostname: s13-t31-tg1.
1212     - IPMI IP: 10.30.50.45
1213     - Host IP: 10.30.51.48
1214     - portnames:
1215         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1216         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1217         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1218         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1219         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1220         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1221         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1222         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1223 - ServerB14 [Server-Type-B1]:
1224     - testbedname: testbed32.
1225     - hostname: s14-t32-sut1.
1226     - IPMI IP: 10.30.50.55
1227     - Host IP: 10.30.51.58
1228     - portnames:
1229         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1230         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1231         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1232         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1233         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1234         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1235         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1236         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1237 - ServerB15 [Server-Type-B1]:
1238     - testbedname: testbed32.
1239     - hostname: s15-t32-sut2.
1240     - IPMI IP: 10.30.50.56
1241     - Host IP: 10.30.51.59
1242     - portnames:
1243         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1244         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1245         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1246         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1247         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1248         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1249         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1250         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1251 - ServerB16 [Server-Type-B2]:
1252     - testbedname: testbed32.
1253     - hostname: s16-t32-tg1.
1254     - IPMI IP: 10.30.50.57
1255     - Host IP: 10.30.51.60
1256     - portnames:
1257         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1258         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1259         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1260         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1261         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1262         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1263         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1264         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1265 ```
1266
1267 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1268
1269 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1270
1271 ```
1272 - ServerB22 [Server-Type-B5]:
1273     - testbedname: testbed35.
1274     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1275     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1276     - Host IP: 10.30.51.9
1277     - portnames:
1278         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1279         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1280     - 1GB ports (tbd)
1281 - ServerB23 [Server-Type-B5]:
1282     - testbedname: testbed35.
1283     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1284     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1285     - Host IP: 10.30.51.10
1286     - portnames:
1287         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1288         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1289     - 1GB ports (tbd)
1290 - ServerB24 [Server-Type-B5]:
1291     - testbedname: testbed35.
1292     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1293     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1294     - Host IP: 10.30.51.11
1295     - portnames:
1296         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1297         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1298     - 1GB ports (tbd)
1299 ```
1300
1301 #### 3-Node-Taishan Servers (3n-tsh) WIP
1302
1303 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1304
1305 ```
1306 - ServerB17 [Server-Type-B3]:
1307     - testbedname: testbed33.
1308     - hostname: s17-t33-sut1.
1309     - IPMI IP: 10.30.50.36
1310     - Host IP: 10.30.51.36
1311     - portnames:
1312         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1313         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1314         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1315         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1316 - ServerB18 [Server-Type-B3]:
1317     - testbedname: testbed33.
1318     - hostname: s18-t33-sut2.
1319     - IPMI IP: 10.30.50.37
1320     - Host IP: 10.30.51.37
1321     - portnames:
1322         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1323         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1324         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1325         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1326 - ServerB19 [Server-Type-B2]:
1327     - testbednames: testbed33 and testbed34.
1328     - hostname: s19-t33t34-tg1.
1329     - IPMI IP: 10.30.50.46
1330     - Host IP: 10.30.51.49
1331     - portnames:
1332         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1333         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1334         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1335         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1336         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1337         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1338         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1339         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1340         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1341         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1342 - ServerB20 [Server-Type-B4]:
1343     - testbedname: testbed34.
1344     - hostname: s20-t34-sut1.
1345     - IPMI IP: N/A
1346     - Host IP: 10.30.51.41
1347     - portnames:
1348         - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1349         - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1350 - ServerB21 [Server-Type-B4]:
1351     - testbedname: testbed34.
1352     - hostname: s21-t34-sut2.
1353     - IPMI IP: N/A
1354     - Host IP: 10.30.51.42
1355     - portnames:
1356         - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1357         - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1358 ```
1359
1360 #### 3-Node-Denverton Servers (3n-dnv) WIP
1361
1362 ```
1363 - ServerB30 [Server-Type-B10]:
1364     - testbednames: testbed35.
1365     - hostname: s30-t35-sut1.
1366     - IPMI IP: 10.30.55.12
1367     - Host IP: 10.32.8.12
1368     - portnames:
1369         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1370         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1371         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1372         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1373 - ServerB31 [Server-Type-B10]:
1374     - testbednames: testbed35.
1375     - hostname: s31-t35-sut2.
1376     - IPMI IP: 10.30.55.13
1377     - Host IP: 10.32.8.13
1378     - portnames:
1379         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1380         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1381         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1382         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1383 ```
1384
1385 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1386
1387 ```
1388 To be completed.
1389 ```
1390
1391 ### Per Testbed Wiring
1392
1393 #### 1-Node-Skylake Wiring (1n-skx) PROD
1394
1395 ```
1396 - testbed11:
1397     - ring1 10GE-ports x710-4p10GE:
1398         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1399     - ring2 10GE-ports x710-4p10GE:
1400         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1401     - ring3 10GE-ports x710-4p10GE:
1402         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1403     - ring4 10GE-ports x710-4p10GE:
1404         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1405 - testbed12:
1406     - ring1 10GE-ports x710-4p10GE:
1407         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1408     - ring2 10GE-ports x710-4p10GE:
1409         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1410     - ring3 10GE-ports x710-4p10GE:
1411         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1412     - ring4 10GE-ports x710-4p10GE:
1413         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1414 ```
1415
1416 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1417
1418 ```
1419 - testbed13:
1420     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1421         - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1422     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1423         - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1424     - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1425         - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1426 ```
1427
1428 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1429
1430 ```
1431 - testbed14:
1432     - ring1 10GE-ports x710-4p10GE:
1433         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1434     - ring2 10GE-ports x710-4p10GE:
1435         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1436     - ring3 10GE-ports x710-4p10GE:
1437         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1438     - ring4 10GE-ports x710-4p10GE:
1439         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1440 ```
1441
1442 #### 2-Node-Skylake Wiring (2n-skx) PROD
1443
1444 ```
1445 - testbed21:
1446     - ring1 10GE-ports x710-4p10GE on SUT:
1447         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1448         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1449     - ring2 10GE-ports x710-4p10GE on SUT:
1450         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1451         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1452     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1453         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1454         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1455 - testbed22:
1456     - ring1 10GE-ports x710-4p10GE on SUT:
1457         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1458         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1459     - ring2 10GE-ports x710-4p10GE on SUT:
1460         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1461         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1462     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1463         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1464         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1465 - testbed23:
1466     - ring1 10GE-ports x710-4p10GE on SUT:
1467         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1468         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1469     - ring2 10GE-ports x710-4p10GE on SUT:
1470         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1471         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1472     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1473         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1474         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1475 - testbed24:
1476     - ring1 10GE-ports x710-4p10GE on SUT:
1477         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1478         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1479     - ring2 10GE-ports x710-4p10GE on SUT:
1480         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1481         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1482     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1483         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1484         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1485 ```
1486
1487 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1488
1489 ```
1490 - testbed26:
1491     - ring1 10GE-ports x553 copper port on SUT:
1492         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1493         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1494     - ring2 10GE-ports x553 fiber port on SUT:
1495         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1496         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1497 ```
1498
1499 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1500
1501 ```
1502 - testbed25:
1503     - link1 10GE-port x710-4p10GE on SUT:
1504         - t25-tg1-p1 to t25-sut1-c2/p1.
1505     - link2 10GE-port x710-4p10GE on SUT:
1506         - t25-tg1-p2 to t25-sut1-c2/p2.
1507     - link3 10GE-port x710-4p10GE on SUT:
1508         - t25-tg1-p3 to t25-sut1-c2/p3.
1509     - link4 10GE-port x710-4p10GE on SUT:
1510         - t25-tg1-p4 to t25-sut1-c2/p4.
1511 ```
1512
1513 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1514
1515 ```
1516 - testbed27:
1517     - ring1 10GE-ports x710-4p10GE on SUT:
1518         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1519         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1520     - ring2 10GE-ports x710-4p10GE on SUT:
1521         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1522         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1523     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1524         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1525         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1526     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1527         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1528         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1529 - testbed28:
1530     - ring1 10GE-ports x710-4p10GE on SUT:
1531         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1532         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1533     - ring2 10GE-ports x710-4p10GE on SUT:
1534         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1535         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1536     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1537         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1538         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1539     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1540         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1541         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1542 - testbed29:
1543     - ring1 10GE-ports x710-4p10GE on SUT:
1544         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1545         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1546     - ring2 10GE-ports x710-4p10GE on SUT:
1547         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1548         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1549     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1550         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1551         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1552     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1553         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1554         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1555 ```
1556
1557 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1558
1559 ```
1560  1. testbed1:
1561     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1562         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1563         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1564         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1565     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1566         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1567         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1568         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1569     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1570         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1571         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1572         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1573     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1574         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1575         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1576         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1577     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1578         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1579         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1580         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1581     - TG loopback ports Intel NIC x710 2p10GE
1582         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1583
1584  2. testbed2:
1585     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1586         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1587         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1588         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1589     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1590         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1591         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1592         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1593     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1594         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1595         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1596         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1597     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1598         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1599         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1600         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1601     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1602         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1603         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1604         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1605     - TG loopback ports Intel NIC x710 2p10GE
1606         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1607
1608  3. testbed3:
1609     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1610         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1611         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1612         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1613     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1614         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1615         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1616         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1617     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1618         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1619         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1620         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1621     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1622         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1623         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1624         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1625     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1626         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1627         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1628         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1629     - TG loopback ports Intel NIC x710 2p10GE
1630         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1631 ```
1632
1633 #### 3-Node-Skylake Wiring (3n-skx) PROD
1634
1635 ```
1636 - testbed31:
1637     - ring1 10GE-ports x710-4p10GE on SUTs:
1638         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1639         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1640         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1641     - ring2 10GE-ports x710-4p10GE on SUT:
1642         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1643         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1644         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1645     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1646         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1647         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1648         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1649     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1650         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1651         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1652         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1653     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1654         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1655         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1656 - testbed32:
1657     - ring1 10GE-ports x710-4p10GE on SUTs:
1658         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1659         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1660         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1661     - ring2 10GE-ports x710-4p10GE on SUT:
1662         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1663         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1664         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1665     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1666         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1667         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1668         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1669     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1670         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1671         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1672         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1673     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1674         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1675         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1676 ```
1677
1678 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1679
1680 ```
1681 To be completed.
1682 ```
1683
1684 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1685
1686 ```
1687 - testbed33:
1688     - ring1 10GE-ports x520-2p10GE on SUTs:
1689         - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1690         - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1691         - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1692     - ring2 25GE-ports cx4-2p25GE on SUTs:
1693         - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1694         - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1695         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1696 ```
1697
1698 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1699
1700 ```
1701 - testbed34:
1702     - ring1 10GE-ports Marvell on SUTs:
1703         - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1704         - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1705         - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1706 ```
1707
1708 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1709
1710 ```
1711 - testbed35:
1712     - ring1 10GE-ports x553 copper port on SUTs:
1713         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1714         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1715         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1716     - ring2 10GE-ports x553 fiber port on SUTs:
1717         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1718         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1719         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1720 ```
1721
1722 ## Inventory
1723
1724 ### Appliances
1725
1726 ```
1727 1. Ixia PerfectStorm One Appliance
1728     - 1 * PS10GE4NG
1729         - Chassis: PS10GE4NG.
1730         - Motherboard: SuperMicro X11DPG-QT.
1731         - Processors: Quad-Core, Intel Processor.
1732         - HW accelerators: FPGA offload.
1733         - RAM Memory: 64GB.
1734         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1735         - Physical Interfaces: 4 * 10GE SFP+.
1736         - Operating System: Native IxOS.
1737 ```
1738
1739 ### Arm Servers
1740
1741 ```
1742 1. Arm Cortex A-72 servers
1743     - 1 * ThunderX2
1744         - Chassis: Marvell ThunderX2
1745         - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1746         - RAM Memory: 4* 32GB RDIMM
1747         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1748     - 2 * Huawei TaiShan 2280.
1749         - Chassis: Huawei TaiShan 2280.
1750         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1751         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1752         - Disks: 1* 4TB SATA HDD.
1753     - 3 * MACCHIATObin
1754         - Chassis: MACCHIATObin.
1755         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1756         - RAM Memory: 1* 16GB DDR4.
1757         - Disks: 1* 128GB(?) SATA SDD.
1758 ```
1759
1760 ### Xeon and Atom Servers
1761
1762 ```
1763 1. Intel Xeon servers:
1764     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1765         - Chassis: SuperMicro SYS-7049GP-TRT.
1766         - Motherboard: SuperMicro X11DPG-QT.
1767         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1768         - RAM Memory: 16* 16GB DDR4-2666MHz.
1769         - Disks: 2* 1.6TB 6G SATA SSD.
1770 2. Intel Atom servers with Rangely processors.
1771     - 3 * Netgate XG-2758-1u
1772         - Chassis: Netgate XG-2758-1u
1773         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1774         - RAM Memory: 16GB ECC
1775         - Disks: 150 GB
1776 ```
1777
1778 ### Network Interface Cards
1779
1780 ```
1781 1. 10GE NICs
1782     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1783     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1784     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1785 2. 25GE NICs
1786     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1787 3. 40GE NICs
1788     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1789 4. 100GE NICs
1790     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1791 ```
1792
1793 ### Pluggables and Cables
1794
1795 Pluggables:
1796
1797 ```
1798 1. 10GE SFP+
1799     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1800     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1801 2. 25GE SFP28
1802     - None
1803 3. 40GE QSFP+
1804     - None
1805 4. 100GE
1806     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1807 ```
1808
1809 Standalone cables:
1810
1811 ```
1812 1. 10GE
1813     - None
1814 2. 25GE
1815     - None
1816 3. 40GE QSFP+
1817     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1818 4. 100GE
1819     - None
1820 ```
1821
1822 ### Other Parts