docs: update arm hardware testbed specifications
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
15    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19    1. [Requirements](#requirements)
20    1. [Addressing](#addressing)
21    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24    1. [Server Types](#server-types)
25    1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29       1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
31       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32       1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34       1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35       1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup])
36       1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
37       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
38       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
39       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-wip)
40    1. [Per Testbed Wiring](#per-testbed-wiring)
41       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42       1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43       1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45       1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48       1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup])
49       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
50       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
51       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
52       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-wip)
53 1. [Inventory](#inventory)
54    1. [Appliances](#appliances)
55    1. [Arm Servers](#arm-servers)
56    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57    1. [Network Interface Cards](#network-interface-cards)
58    1. [Pluggables and Cables](#pluggables-and-cables)
59    1. [Other Parts](#other-parts)
60
61 ## Purpose
62
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
65
66 ## Testbeds Overview
67
68 ### Summary List
69
70 ```
71  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
72  1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0    0
73  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0
74  3. 1-Node-Thunderx2   idle   tx2   na    1    1    0    0    0    0    0    0    1    0    0    0
75  4. 1-Node-Thunderx2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0
76  5. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    1    0
77  6. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0
78  7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0
79  8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0
80  9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    6    0
81 10. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0    0
82 11. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0
83 12. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0
84 13. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0
85 14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0
86 15. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    2
87                                  Totals: 27   36 16.5   12 18.5    1    2    3    3    2    7    2
88 ```
89
90 ### 1-Node-Skylake Xeon Intel (1n-skx)
91
92 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
93 ports connected back-to-back ([Server Types](#server-types)).
94 Used for FD.io VPP_Device functional driver tests.
95
96 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
97
98 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
99 ports connected back-to-back ([Server Types](#server-types)).
100 Used for FD.io VPP_Device functional driver tests.
101
102 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
103
104 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
105 NIC ports connected back-to-back ([Server Types](#server-types)).
106
107 Used for FD.io VPP_Device functional driver tests.
108
109 ### 2-Node-Skylake Xeon Intel (2n-skx)
110
111 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
112 (Server-Type-B2) connected in a 2-node circular topology
113 ([Server Types](#server-types)).
114 Used for FD.io performance tests.
115
116 ### 2-Node-Denverton Atom Intel (2n-dnv)
117
118 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
119 TG (Server-Type-B2) connected in a 2-node circular topology
120 ([Server Types](#server-types)).
121 Used for FD.io performance tests.
122
123 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
124
125 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
126 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
127 circular topology ([Server Types](#server-types)).
128 Used for FD.io TCP/IP and HTTP performance tests.
129
130 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
131
132 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
133 one TG (Server-Type-C3) connected in a 2-node circular topology
134 ([Server Types](#server-types)).
135 Used for FD.io performance tests.
136
137 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
138
139 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
140 one TG (Server-Type-D2) connected in a 2-node circular topology
141 ([Server Types](#server-types)).
142 Used for FD.io performance tests.
143
144 ### 3-Node-Haswell Xeon Intel (3n-hsw)
145
146 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
147 TG (Server-Type-A2) connected in a 3-node circular topology
148 ([Server Types](#server-types)).
149 Used for FD.io performance tests.
150
151 ### 3-Node-Skylake Xeon Intel (3n-skx)
152
153 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
154 TG (Server-Type-B2) connected in a 3-node circular topology.
155 Used for FD.io performance tests.
156
157 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
158
159 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
160 TG (Server-Type-B2) connected in a 3-node circular topology
161 ([Server Types](#server-types)).
162 Used for FD.io performance tests.
163
164 ### 3-Node-Rangeley Atom Testbeds
165
166 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
167 TG (Server-Type-2) connected in a 3-node circular topology
168 ([Server Types](#server-types)).
169 Used for FD.io performance tests.
170
171 ## Server Management
172
173 ### Requirements
174
175 For management purposes, each server must have following two ports
176 connected to the management network:
177
178 ```
179 - 1GE IPMI port
180   - IPMI - Intelligent Platform Management Interface.
181   - Required for access to embedded server management with WebUI, CLI,
182     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
183 - 1GE/10GE/40GE management port
184   - hostOS management port for general system management.
185 ```
186
187 ### Addressing
188
189 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
190 Management port, which are connected to two different VLANs.
191
192 ```
193 1. LOM (IPMI) VLAN:
194     - Subnet: 10.30.50.0/24
195     - Gateway: 10.30.50.1
196     - Broadcast: 10.30.50.255
197     - DNS1: 199.204.44.24
198     - DNS2: 199.204.47.54
199 2. Management Vlan:
200     - Subnet: 10.30.51.0/24
201     - Gateway: 10.30.51.1
202     - Broadcast: 10.30.51.255
203     - DNS1: 199.204.44.24
204     - DNS2: 199.204.47.54
205 ```
206
207 To access these hosts, VPN connection is required.
208
209 ### LOM (IPMI) VLAN IP Addresses
210
211 Name         | Comment
212 ------------ | -------
213 10.30.50.0   | network
214 10.30.51.1   | Router
215 10.30.50.2   | LF Reserved
216 10.30.50.3   | LF Reserved
217 10.30.50.4   | LF Reserved
218 10.30.50.5   | LF Reserved
219 10.30.50.6   | LF Reserved
220 10.30.50.7   | LF Reserved
221 10.30.50.8   | LF Reserved
222 10.30.50.9   | LF Reserved
223 10.30.50.10  | LF Reserved
224 10.30.50.11  | LF Reserved
225 10.30.50.12  | LF Reserved
226 10.30.50.13  | LF Reserved
227 10.30.50.14  | LF Reserved
228 10.30.50.15  | LF Reserved
229 10.30.50.16  | t1-tg1
230 10.30.50.17  | t1-sut1
231 10.30.50.18  | t1-sut2
232 10.30.50.20  | t2-tg1
233 10.30.50.21  | t2-sut1
234 10.30.50.22  | t2-sut2
235 10.30.50.24  | t3-tg1
236 10.30.50.25  | t3-sut1
237 10.30.50.26  | t3-sut-2
238 10.30.50.28  | s41-nomad
239 10.30.50.29  | s39-nomad
240 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
241 10.30.50.30  | s40-nomad
242 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
243 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
244 10.30.50.32  | s42-nomad (formerly nomad1)
245 10.30.50.33  | s43-nomad (formerly nomad2)
246 10.30.50.34  | s44-nomad (formerly nomad3)
247 10.30.50.35  | s45-nomad (formerly nomad4)
248 10.30.50.36  | s17-t33-sut1
249 10.30.50.37  | s18-t33-sut2
250 10.30.50.38  | fdio-marvell-dev
251 10.30.50.39  | s53-nomad
252 10.30.50.40  | s54-nomad
253 10.30.50.41  | s3-t21-sut1
254 10.30.50.42  | s4-t21-tg1
255 10.30.50.43  | s11-t31-sut1
256 10.30.50.44  | s12-t31-sut2
257 10.30.50.45  | s13-t31-tg1
258 10.30.50.46  | s19-t33t34-tg1
259 10.30.50.47  | s1-t11-sut1
260 10.30.50.48  | s2-t12-sut1
261 10.30.50.49  | s5-t22-sut1
262 10.30.50.50  | s6-t22-tg1
263 10.30.50.51  | s7-t23-sut1
264 10.30.50.52  | s8-t23-tg1
265 10.30.50.53  | s9-t24-sut1
266 10.30.50.54  | s10-t24-tg1
267 10.30.50.55  | s14-t32-sut1
268 10.30.50.56  | s15-t32-sut2
269 10.30.50.57  | s16-t32-tg1
270 10.30.50.58  | s25-t25-sut1
271 10.30.50.59  | s26-t25-tg1
272 10.30.50.65  | s52-nomad
273 10.30.50.66  | s51-nomad
274 10.30.50.67  | s49-nomad
275 10.30.50.68  | s50-nomad
276 10.30.50.69  | s27-t13-sut
277 10.30.50.70  | s55-t36-sut1
278 10.30.50.71  | s56-t37-sut1
279 10.30.50.255 | Broadcast
280 n/a          | s20-t34-sut1
281 n/a          | s21-t34-sut2
282 10.30.55.0   | network
283 10.30.55.1   | Router
284 10.30.55.10  | s28-t26t35-tg1
285 10.30.55.11  | s29-t26-sut1
286 10.30.55.12  | s30-t35-sut1
287 10.30.55.13  | s31-t35-sut2
288 10.30.55.14  | s46-nomad (formerly server-type-c4-1)
289 10.30.55.15  | s47-nomad (formerly server-type-c4-2)
290 10.30.55.16  | s48-nomad (formerly server-type-c4-3)
291 10.30.55.17  | s32-t14-sut1
292 10.30.55.18  | s33-t27-sut1
293 10.30.55.19  | s34-t27-tg1
294 10.30.55.20  | s35-t28-sut1
295 10.30.55.21  | s36-t28-tg1
296 10.30.55.22  | s37-t29-sut1
297 10.30.55.23  | s38-t29-tg1
298 10.30.55.24  | s60-t210-sut1
299 10.30.55.25  | s61-t210-tg1
300 10.30.55.255 | Broadcast
301
302 ### Management VLAN IP Addresses
303
304 Name                      | Comment
305 ------------------------- | -------
306 10.30.51.0                | network
307 10.30.51.1                | Router
308 10.30.51.2                | LF Reserved
309 10.30.51.3                | LF Reserved
310 10.30.51.4                | LF Reserved
311 10.30.51.5                | LF Reserved
312 10.30.51.6                | LF Reserved
313 10.30.51.7                | LF Reserved
314 10.30.51.8                | LF Reserved
315 10.30.51.9                | s22-t35-sut1 (netgate-1)
316 10.30.51.10               | s23-t35-sut2 (netgate-2)
317 10.30.51.11               | s24-t35-sut3 (netgate-3)
318 10.30.51.12               | softiron-1 (decommissioned)
319 10.30.51.13               | softiron-2 (decommissioned)
320 10.30.51.14               | softiron-3 (decommissioned)
321 10.30.51.15               | LF Reserved
322 10.30.51.16               | t1-tg1
323 10.30.51.17               | t1-sut1
324 10.30.51.18               | t1-sut2
325 10.30.51.20               | t2-tg1
326 10.30.51.21               | t2-sut1
327 10.30.51.22               | t2-sut2
328 10.30.51.24               | t3-tg1
329 10.30.51.25               | t3-sut1
330 10.30.51.26               | t3-sut-2
331 10.30.51.28               | s41-nomad
332 10.30.51.29               | s39-nomad
333 10.30.51.30               | s40-nomad
334 10.30.51.32               | s42-nomad (formerly nomad1)
335 10.30.51.33               | s43-nomad (formerly nomad2)
336 10.30.51.34               | s44-nomad (formerly nomad3)
337 10.30.51.35               | s45-nomad (formerly nomad4)
338 10.30.51.36               | s17-t33-sut1
339 10.30.51.37               | s18-t33-sut2
340 10.30.51.38               | fdio-marvell-dev
341 10.30.51.39               | s53-nomad
342 10.30.51.40               | s54-nomad
343 10.30.51.41               | s20-t34-sut1 (decommissioned)
344 10.30.51.42               | s21-t34-sut2 (decommissioned)
345 10.30.51.43               | fdio-mcbin3 (decommissioned)
346 10.30.51.44               | s3-t21-sut1
347 10.30.51.45               | s4-t21-tg1
348 10.30.51.46               | s11-t31-sut1
349 10.30.51.47               | s12-t31-sut2
350 10.30.51.48               | s13-t31-tg1
351 10.30.51.49               | s19-t33t34-tg1
352 10.30.51.50               | s1-t11-sut1
353 10.30.51.51               | s2-t12-sut1
354 10.30.51.52               | s5-t22-sut1
355 10.30.51.53               | s6-t22-tg1
356 10.30.51.54               | s7-t23-sut1
357 10.30.51.55               | s8-t23-tg1
358 10.30.51.56               | s9-t24-sut1
359 10.30.51.57               | s10-t24-tg1
360 10.30.51.58               | s14-t32-sut1
361 10.30.51.59               | s15-t32-sut2
362 10.30.51.60               | s16-t32-tg1
363 10.30.51.61               | s25-t25-sut1
364 10.30.51.62               | s26-t25-tg1
365 10.30.51.65               | s52-nomad
366 10.30.51.66               | s51-nomad
367 10.30.51.67               | s49-nomad
368 10.30.51.68               | s50-nomad
369 10.30.51.69               | s27-t13-sut1
370 10.30.51.70               | s55-t36-sut1
371 10.30.51.71               | s56-t37-sut1
372 10.30.51.72-10.30.51.105  | FREE
373 10.30.51.106-10.30.51.180 | FREE
374 10.30.51.181-10.30.51.254 | FREE
375 10.30.51.255              | Broadcast
376 10.32.8.0                 | network
377 10.32.8.1                 | Router
378 10.32.8.10                | s28-t26t35-tg1
379 10.32.8.11                | s29-t26-sut1
380 10.32.8.12                | s30-t35-sut1
381 10.32.8.13                | s31-t35-sut2
382 10.32.8.14                | s46-nomad (formerly server-type-c4-1)
383 10.32.8.15                | s47-nomad (formerly server-type-c4-2)
384 10.32.8.16                | s48-nomad (formerly server-type-c4-3)
385 10.32.8.17                | s32-t14-sut1
386 10.32.8.18                | s33-t27-sut1
387 10.32.8.19                | s34-t27-tg1
388 10.32.8.20                | s35-t28-sut1
389 10.32.8.21                | s36-t28-tg1
390 10.32.8.22                | s37-t29-sut1
391 10.32.8.23                | s38-t29-tg1
392 10.32.8.24                | s60-t210-sut1
393 10.32.8.25                | s61-t210-tg1
394 10.32.8.255               | Broadcast
395
396 ## Server Specifications
397
398 ### Server Types
399
400 FD.io CSIT lab contains following server types:
401 ```
402 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
403     - Quantity: 6 servers.
404     - Physical connectivity:
405         - CIMC and host management ports.
406         - NIC ports connected in 3-node topologies.
407     - Main HW configuration:
408         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
409         - Processors: 2* E5-2699v3 2.3 GHz.
410         - RAM Memory: 16* 32GB DDR4-2133MHz.
411         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
412     - NICs configuration:
413         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
414             - PCIe Slot1: Cisco VIC 1385 2p40GE.
415             - PCIe Slot2: Intel NIC x520 2p10GE.
416             - PCIe Slot3: empty.
417         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
418             - PCIe Slot4: Intel NIC xl710 2p40GE.
419             - PCIe Slot5: Intel NIC x710 2p10GE.
420             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
421         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
422 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
423     - Quantity: 3 servers.
424     - Physical connectivity:
425         - CIMC and host management ports.
426         - NIC ports connected in 3-node topologies.
427     - Main HW configuration:
428         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
429         - Processors: 2* E5-2699v3 2.3 GHz.
430         - RAM Memory: 16* 32GB DDR4-2133MHz.
431         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
432     - NICs configuration:
433         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
434             - PCIe Slot1: Intel NIC xl710 2p40GE.
435             - PCIe Slot2: Intel NIC x710 2p10GE.
436             - PCIe Slot3: Intel NIC x710 2p10GE.
437         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
438             - PCIe Slot4: Intel NIC xl710 2p40GE.
439             - PCIe Slot5: Intel NIC x710 2p10GE.
440             - PCIe Slot6: Intel NIC x710 2p10GE.
441         - MLOM slot: empty.
442 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
443     - Quantity: 3 servers.
444     - Physical connectivity:
445         - CIMC and host management ports.
446         - no NIC ports, standalone setup.
447     - Main HW configuration:
448         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
449         - Processors: 2* E5-2699v3 2.3 GHz.
450         - RAM Memory: 16* 32GB DDR4-2133MHz.
451         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
452     - NICs configuration:
453         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
454             - no cards.
455         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
456             - no cards.
457         - MLOM slot: empty.
458 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
459     - Quantity: ---
460     - Physical connectivity:
461         - IPMI and host management ports.
462         - NIC ports connected into 2-node and 3-node topologies.
463     - Main HW configuration:
464         - Chassis: SuperMicro SYS-7049GP-TRT.
465         - Motherboard: SuperMicro X11DPG-QT.
466         - Processors: 2* Intel Platinum 8180 2.5 GHz.
467         - RAM Memory: 16* 16GB DDR4-2666MHz.
468         - Disks: 2* 1.6TB 6G SATA SSD.
469     - NICs configuration:
470         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
471             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
472             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
473             - PCIe Slot9 5e:00.xx: empty.
474         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
475             - PCIe Slot6 86:00.xx: empty.
476             - PCIe Slot8 af:00.xx: empty.
477             - PCIe Slot10 d8:00.xx: empty.
478 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
479     - Quantity: ---
480     - Physical connectivity:
481         - IPMI and host management ports.
482         - NIC ports connected into 2-node and 3-node topologies.
483     - Main HW configuration:
484         - Chassis: SuperMicro SYS-7049GP-TRT.
485         - Motherboard: SuperMicro X11DPG-QT.
486         - Processors: 2* Intel Platinum 8180 2.5 GHz.
487         - RAM Memory: 16* 16GB DDR4-2666MHz.
488         - Disks: 2* 1.6TB 6G SATA SSD.
489     - NICs configuration:
490         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
491             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
492             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
493             - PCIe Slot9 5e:00.xx: empty.
494         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
495             - PCIe Slot6 86:00.xx: empty.
496             - PCIe Slot8 af:00.xx: empty.
497             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
498 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
499     - Quantity: 2
500     - Physical connectivity:
501         - IPMI(?) and host management ports.
502         - NIC ports connected into 3-node topology.
503     - Main HW configuration:
504         - Chassis: Huawei TaiShan 2280.
505         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
506         - RAM Memory: 8* 16GB DDR4-2400MT/s
507         - Disks: 1* 4TB SATA HDD
508     - NICs configuration:
509         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
510         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
511 7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
512     - Quantity: TBD based on testbed allocation.
513     - Physical connectivity:
514         - Management: serial Port (usb) for console
515         - NIC ports connected into 2-node.
516     - Main HW configuration:
517         - Chassis: Netgate XG-2758-1u
518         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
519         - RAM Memory: 16GB ECC
520         - Disks: 150 GB
521     - NICs configuration:
522         - 2x 10Gb Intel 82599ES
523         - 4x 1GB Intel I354
524 8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
525     - Quantity: 2.
526     - Physical connectivity:
527         - IPMI and host management ports.
528         - NIC ports connected into 1-node topologies.
529     - Main HW configuration:
530         - Chassis: SuperMicro SYS-7049GP-TRT.
531         - Motherboard: SuperMicro X11DPG-QT.
532         - Processors: 2* Intel Platinum 8180 2.5 GHz.
533         - RAM Memory: 16* 16GB DDR4-2666MHz.
534         - Disks: 2* 1.6TB 6G SATA SSD.
535     - NICs configuration:
536         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
537             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
538             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
539             - PCIe Slot9 5e:00.xx: empty.
540         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
541             - PCIe Slot6 86:00.xx: empty.
542             - PCIe Slot8 af:00.xx: empty.
543             - PCIe Slot10 d8:00.xx: empty.
544 9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
545     - Quantity: 1.
546     - Physical connectivity:
547         - Host management interface: 10/100/1000-BaseT.
548         - 8-port 10GE SFP+ integrated NIC.
549     - Main HW configuration:
550         - Chassis: PS10GE4NG.
551         - Motherboard: SuperMicro X11DPG-QT.
552         - Processors: Quad-Core, Intel Processor.
553         - HW accelerators: FPGA offload.
554         - RAM Memory: 64GB.
555         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
556         - Physical Interfaces: 4 * 10GE SFP+.
557         - Operating System: Native IxOS.
558     - Interface configuration:
559         - Port-1: 10GE SFP+.
560         - Port-2: 10GE SFP+.
561         - Port-3: 10GE SFP+.
562         - Port-4: 10GE SFP+.
563 10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
564     - Quantity: 1.
565     - Physical connectivity:
566         - IPMI and host management ports.
567         - NIC ports.
568     - Main HW configuration:
569         - Chassis: SuperMicro SYS-7049GP-TRT.
570         - Motherboard: SuperMicro X11DPG-QT.
571         - Processors: 2* Intel Platinum 8180 2.5 GHz.
572         - RAM Memory: 16* 16GB DDR4-2666MHz.
573         - Disks: 2* 1.6TB 6G SATA SSD.
574     - NICs configuration:
575         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
576             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
577             - PCIe Slot4 3b:00.xx: empty.
578             - PCIe Slot9 5e:00.xx: empty.
579         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
580             - PCIe Slot6 86:00.xx: empty.
581             - PCIe Slot8 af:00.xx: empty.
582             - PCIe Slot10 d8:00.xx: empty.
583 11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell(Idle).
584     - Quantity: 1
585     - Physical connectivity:
586         - IPMI and host management ports.
587         - NIC ports connected into 1-node topologies.
588     - Main HW configuration:
589         - Chassis: Gigabyte R181-T90 1U
590         - Motherboard: MT91-FS1
591         - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
592         - RAM Memory: 4* 32GB RDIMM
593         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
594     - NICs configuration:
595         - Numa0:
596             - PCIe Slot1 05:00.xx: XL710-QDA2.
597             - PCIe Slot3 08:00.xx: XL710-QDA2.
598         - Numa1:
599             - PCIe Slot6 85:00.xx: XL710-QDA2.
600 12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
601     - Quantity: 4
602     - Physical connectivity:
603         - IPMI and host management ports.
604         - NIC ports.
605     - Main HW configuration:
606         - Chassis: SuperMicro SYS-E300-9A
607         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
608         - RAM Memory: 32GB ECC
609         - Disks: 480 GB
610     - NICs configuration:
611         - 2x 10Gb Intel x553 fiber ports
612         - 2x 10Gb Intel x553 copper ports
613         - 4x 1GB Intel I350 ports
614 13. Server-Type-B11: Purpose - Thunderx2 Arm Marvell SUT for FD.io VPP_Device functional tests.
615     - Quantity: 2
616     - Physical connectivity:
617         - IPMI and host management ports.
618         - NIC ports connected into 1-node topologies.
619     - Main HW configuration:
620         - Chassis: GIGABYTE Rack Mount
621         - Motherboard: MT91-FS4-00
622         - Processors: 2 * Thunderx2 ARMv8 CN9980 2.20 GHz
623         - RAM Memory: 16 * 16GB DIMM
624         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
625     - NICs configuration:
626         - Numa0:
627             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
628             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
629         - Numa1:
630             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
631             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
632
633 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
634     - Quantity: 1.
635     - Physical connectivity:
636         - IPMI and host management ports.
637         - NIC ports connected into 1-node testbed topologies.
638     - Main HW configuration:
639         - Chassis: SuperMicro SYS-7049GP-TRT.
640         - Motherboard: SuperMicro X11DPG-QT.
641         - Processors: 2* Intel Platinum 8280 2.7 GHz.
642         - RAM Memory: 12* 16GB DDR4-2933.
643         - Disks: 2* 1.92TB SATA SSD.
644     - NICs configuration:
645         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
646             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
647             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
648             - PCIe Slot9 5e:00.xx: empty.
649         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
650             - PCIe Slot6 86:00.xx: empty.
651             - PCIe Slot8 af:00.xx: empty.
652             - PCIe Slot10 d8:00.xx: empty.
653 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
654     - Quantity: 3
655     - Physical connectivity:
656         - IPMI and host management ports.
657         - NIC ports connected into 2-node testbed topologies.
658     - Main HW configuration:
659         - Chassis: SuperMicro SYS-7049GP-TRT.
660         - Motherboard: SuperMicro X11DPG-QT.
661         - Processors: 2* Intel Gold 6252N 2.3 GHz.
662         - RAM Memory: 12* 16GB DDR4-2933.
663         - Disks: 2* 1.92TB SATA SSD.
664     - NICs configuration:
665         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
666             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
667             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
668             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
669         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
670             - PCIe Slot6 86:00.xx: empty.
671             - PCIe Slot8 af:00.xx: empty.
672             - PCIe Slot10 d8:00.xx: empty.
673 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
674     - Quantity: 3.
675     - Physical connectivity:
676         - IPMI and host management ports.
677         - NIC ports connected into 2-node testbed topologies.
678     - Main HW configuration:
679         - Chassis: SuperMicro SYS-7049GP-TRT.
680         - Motherboard: SuperMicro X11DPG-QT.
681         - Processors: 2* Intel Platinum 8280 2.7 GHz.
682         - RAM Memory: 12* 16GB DDR4-2933.
683         - Disks: 2* 1.92TB SATA SSD.
684     - NICs configuration:
685         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
686             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
687             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
688             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
689         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
690             - PCIe Slot6 86:00.xx: empty.
691             - PCIe Slot8 af:00.xx: empty.
692             - PCIe Slot10 d8:00.xx: empty.
693 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
694     - Quantity: 3.
695     - Physical connectivity:
696         - CIMC and host management ports.
697         - no NIC ports, standalone setup.
698     - Main HW configuration:
699         - Chassis: SuperMicro 1029P-WTRT.
700         - Motherboard: SuperMicro X11DDW-NT.
701         - Processors: 2* Intel Platinum 8280 2.7 GHz.
702         - RAM Memory: 12* 16GB DDR4-2933.
703         - Disks: 4* 1.92TB SATA SSD.
704     - NICs configuration:
705         - Numa0:
706             - no cards.
707         - Numa1:
708             - no cards.
709
710 18. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
711     - Quantity: 1.
712     - Physical connectivity:
713         - IPMI and host management ports.
714         - NIC ports connected into 2-node testbed topologies.
715     - Main HW configuration:
716         - Chassis: SuperMicro AS-1114S-WTRT
717         - Processors: 1* AMD EPYC 7532 2.4 GHz.
718         - RAM Memory: 8* 32GB DDR4-2933.
719         - Disks: 1* 1TB SATA SSD.
720     - NICs configuration:
721         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
722             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
723             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
724             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
725 19. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
726     - Quantity: 1.
727     - Physical connectivity:
728         - IPMI and host management ports.
729         - NIC ports connected into 2-node testbed topologies.
730     - Main HW configuration:
731         - Chassis: SuperMicro AS-1114S-WTRT
732         - Processors: 1* AMD EPYC 7532 2.4 GHz.
733         - RAM Memory: 8* 32GB DDR4-2933.
734         - Disks: 1* 1TB SATA SSD.
735     - NICs configuration:
736         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
737             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
738             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
739             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
740 ```
741
742 ### Naming Convention
743
744 Following naming convention is used within this page to specify physical
745 connectivity and wiring across defined CSIT testbeds:
746
747 ```
748 - testbedname: testbedN.
749 - hostname:
750     - traffic-generator: tN-tgW.
751     - system-under-testX: tN-sutX.
752 - portnames:
753     - tN-tgW-cY/pZ.
754     - tN-sutX-cY/pZ.
755 - where:
756     - N - testbed number.
757     - tgW - server acts as traffic-generator with W index.
758     - sutX - server acts as system-under-test with X index.
759     - Y - PCIe slot number denoting a NIC card number within the host.
760     - Z - port number on the NIC card.
761 ```
762
763 ## Testbeds Configuration
764
765 ### Per Testbed Server Allocation and Naming
766
767 #### 1-Node-Skylake Servers (1n-skx) PROD
768
769 ```
770 - SUT [Server-Type-B6]:
771     - testbedname: testbed11.
772     - hostname: s1-t11-sut1.
773     - IPMI IP: 10.30.50.47
774     - Host IP: 10.30.51.50
775     - portnames:
776         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
777         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
778         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
779         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
780         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
781         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
782         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
783         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
784 - SUT [Server-Type-B6]:
785     - testbedname: testbed12.
786     - hostname: s2-t12-sut1.
787     - IPMI IP: 10.30.50.48
788     - Host IP: 10.30.51.51
789     - portnames:
790         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
791         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
792         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
793         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
794         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
795         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
796         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
797         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
798 ```
799
800 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
801
802 ```
803 - SUT [Server-Type-B11]:
804     - testbedname: testbed36
805     - hostname: s55-t36-sut1
806     - IPMI IP: 10.30.50.70
807     - Host IP: 10.30.51.70
808     - portnames:
809         - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
810         - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
811         - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
812         - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
813         - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
814         - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
815         - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
816         - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
817
818 - SUT [Server-Type-B11]:
819     - testbedname: testbed37
820     - hostname: s56-t37-sut1
821     - IPMI IP: 10.30.50.71
822     - Host IP: 10.30.51.71
823     - portnames:
824         - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
825         - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
826         - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
827         - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
828         - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
829         - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
830         - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
831         - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
832 ```
833
834 #### 1-Node-Cascadelake Servers (1n-clx) PROD
835
836 ```
837 - SUT [Server-Type-C1]:
838     - testbedname: testbed11.
839     - hostname: s32-t14-sut1.
840     - IPMI IP: 10.30.55.17
841     - Host IP: 10.32.8.17
842     - portnames:
843         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
844         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
845         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
846         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
847         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
848         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
849         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
850         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
851 ```
852
853 #### 2-Node-Skylake Servers (2n-skx) PROD
854
855 ```
856 - SUT [Server-Type-B1]:
857     - testbedname: testbed21.
858     - hostname: s3-t21-sut1.
859     - IPMI IP: 10.30.50.41
860     - Host IP: 10.30.51.44
861     - portnames:
862         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
863         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
864         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
865         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
866         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
867         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
868 - TG [Server-Type-B2]:
869     - testbedname: testbed21.
870     - hostname: s4-t21-tg1.
871     - IPMI IP: 10.30.50.42
872     - Host IP: 10.30.51.45
873     - portnames:
874         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
875         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
876         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
877         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
878         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
879         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
880 - SUT [Server-Type-B1]:
881     - testbedname: testbed22.
882     - hostname: s5-t22-sut1.
883     - IPMI IP: 10.30.50.49
884     - Host IP: 10.30.51.52
885     - portnames:
886         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
887         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
888         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
889         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
890         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
891         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
892 - TG [Server-Type-B2]:
893     - testbedname: testbed22.
894     - hostname: s6-t22-tg1.
895     - IPMI IP: 10.30.50.50
896     - Host IP: 10.30.51.53
897     - portnames:
898         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
899         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
900         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
901         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
902         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
903         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
904 - SUT [Server-Type-B1]:
905     - testbedname: testbed23.
906     - hostname: s7-t23-sut1.
907     - IPMI IP: 10.30.50.51
908     - Host IP: 10.30.51.54
909     - portnames:
910         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
911         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
912         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
913         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
914         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
915         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
916 - TG [Server-Type-B2]:
917     - testbedname: testbed23.
918     - hostname: s8-t23-tg1.
919     - IPMI IP: 10.30.50.52
920     - Host IP: 10.30.51.55
921     - portnames:
922         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
923         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
924         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
925         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
926         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
927         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
928 - SUT [Server-Type-B1]:
929     - testbedname: testbed24.
930     - hostname: s9-t24-sut1.
931     - IPMI IP: 10.30.50.53
932     - Host IP: 10.30.51.56
933     - portnames:
934         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
935         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
936         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
937         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
938         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
939         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
940 - TG [Server-Type-B2]:
941     - testbedname: testbed24.
942     - hostname: s10-t24-tg1.
943     - IPMI IP: 10.30.50.54
944     - Host IP: 10.30.51.57
945     - portnames:
946         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
947         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
948         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
949         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
950         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
951         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
952 ```
953
954 #### 2-Node-Denverton Servers (2n-dnv) WIP
955
956 Note: ServerB28 (TG) is shared between testbed26 & testbed35
957
958 ```
959 - TG [Server-Type-B2]:
960     - testbednames: testbed26 and testbed35.
961     - hostname: s28-t26t35-tg1.
962     - IPMI IP: 10.30.55.10
963     - Host IP: 10.32.8.10
964     - portnames:
965         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
966         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
967         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
968         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
969         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
970         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
971         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
972         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
973         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
974         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
975         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
976         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
977 - SUT [Server-Type-B10]:
978     - testbednames: testbed26.
979     - hostname: s29-t26-sut1.
980     - IPMI IP: 10.30.55.11
981     - Host IP: 10.32.8.11
982     - portnames:
983         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
984         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
985         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
986         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
987 ```
988
989 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
990
991 ```
992 - SUT [Server-Type-B8]:
993     - testbedname: testbed25.
994     - hostname: s25-t25-sut1.
995     - IPMI IP: 10.30.50.58
996     - Host IP: 10.30.51.61
997     - portnames:
998         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
999         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1000         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1001         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1002 - TG [Server-Type-B7]:
1003     - testbedname: testbed25.
1004     - hostname: s26-t25-tg1.
1005     - IPMI IP: 10.30.50.59
1006     - Host IP: 10.30.51.62
1007     - portnames:
1008         - s26-t25-tg1-p1 - 10GE-port1.
1009         - s26-t25-tg1-p2 - 10GE-port2.
1010         - s26-t25-tg1-p3 - 10GE-port3.
1011         - s26-t25-tg1-p4 - 10GE-port4.
1012 ```
1013
1014 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
1015
1016 ```
1017 - SUT [Server-Type-C2]:
1018     - testbedname: testbed27.
1019     - hostname: s33-t27-sut1.
1020     - IPMI IP: 10.30.55.18
1021     - Host IP: 10.32.8.18
1022     - portnames:
1023         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1024         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1025         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1026         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1027         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1028         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1029         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1030         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1031 - TG [Server-Type-C3]:
1032     - testbedname: testbed27.
1033     - hostname: s34-t27-tg1.
1034     - IPMI IP: 10.30.55.19
1035     - Host IP: 10.32.8.19
1036     - portnames:
1037         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1038         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1039         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1040         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1041         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1042         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1043         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1044         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1045 - SUT [Server-Type-C2]:
1046     - testbedname: testbed28.
1047     - hostname: s35-t28-sut1.
1048     - IPMI IP: 10.30.55.20
1049     - Host IP: 10.32.8.20
1050     - portnames:
1051         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1052         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1053         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1054         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1055         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1056         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1057         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1058         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1059 - TG [Server-Type-C3]:
1060     - testbedname: testbed28.
1061     - hostname: s36-t28-tg1.
1062     - IPMI IP: 10.30.55.21
1063     - Host IP: 10.32.8.21
1064     - portnames:
1065         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1066         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1067         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1068         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1069         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1070         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1071         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1072         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1073 - SUT [Server-Type-C2]:
1074     - testbedname: testbed29.
1075     - hostname: s37-t29-sut1.
1076     - IPMI IP: 10.30.55.22
1077     - Host IP: 10.32.8.22
1078     - portnames:
1079         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1080         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1081         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1082         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1083         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1084         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1085         - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1086         - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1087 - TG [Server-Type-C3]:
1088     - testbedname: testbed29.
1089     - hostname: s38-t29-tg1.
1090     - IPMI IP: 10.30.55.23
1091     - Host IP: 10.32.8.23
1092     - portnames:
1093         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1094         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1095         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1096         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1097         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1098         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1099         - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1100         - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1101 ```
1102
1103 #### 2-Node-Zen2 Servers (2n-zn2) SETUP
1104
1105 ```
1106 - SUT [Server-Type-D1]:
1107     - testbedname: testbed210.
1108     - hostname: s60-t210-sut1.
1109     - IPMI IP: 10.30.55.24
1110     - Host IP: 10.32.8.24
1111     - portnames:
1112         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1113         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1114         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1115         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1116         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1117         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1118         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1119         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1120 - TG [Server-Type-D2]:
1121     - testbedname: testbed210.
1122     - hostname: s61-t210-tg1.
1123     - IPMI IP: 10.30.55.25
1124     - Host IP: 10.32.8.25
1125     - portnames:
1126         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1127         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1128         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1129         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1130         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1131         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1132         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1133         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1134 ```
1135
1136 #### 3-Node-Haswell Servers (3n-hsw) PROD
1137
1138 ```
1139  1. SUT [Server-Type-A1]:
1140     - testbedname: testbed1.
1141     - hostname: t1-sut1.
1142     - CIMC IP: 10.30.50.17
1143     - Host IP: 10.30.51.17
1144     - portnames:
1145         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1146         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1147         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1148         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1149         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1150         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1151         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1152         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1153         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1154         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1155  2. SUT [Server-Type-A1]:
1156     - testbedname: testbed1.
1157     - hostname: t1-sut2.
1158     - CIMC IP: 10.30.50.18
1159     - Host IP: 10.30.51.18
1160     - portnames:
1161         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1162         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1163         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1164         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1165         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1166         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1167         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1168         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1169         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1170         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1171  3. TG [Server-Type-A2]:
1172     - testbedname: testbed1.
1173     - hostname: t1-tg1.
1174     - CIMC IP: 10.30.50.16
1175     - Host IP: 10.30.51.16
1176     - portnames:
1177         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1178         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1179         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1180         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1181         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1182         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1183         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1184         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1185         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1186         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1187         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1188         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1189  4. SUT [Server-Type-A1]:
1190     - testbedname: testbed2.
1191     - hostname: t2-sut1.
1192     - CIMC IP: 10.30.50.21
1193     - Host IP: 10.30.51.21
1194     - portnames:
1195         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1196         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1197         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1198         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1199         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1200         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1201         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1202         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1203         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1204         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1205  5. SUT [Server-Type-A1]:
1206     - testbedname: testbed2.
1207     - hostname: t2-sut2.
1208     - CIMC IP: 10.30.50.22
1209     - Host IP: 10.30.51.22
1210     - portnames:
1211         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1212         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1213         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1214         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1215         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1216         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1217         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1218         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1219         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1220         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1221  6. TG [Server-Type-A2]:
1222     - testbedname: testbed2.
1223     - hostname: t2-tg1.
1224     - CIMC IP: 10.30.50.20
1225     - Host IP: 10.30.51.20
1226     - portnames:
1227         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1228         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1229         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1230         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1231         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1232         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1233         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1234         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1235         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1236         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1237         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1238         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1239  7. SUT [Server-Type-A1]:
1240     - testbedname: testbed3.
1241     - hostname: t3-sut1.
1242     - CIMC IP: 10.30.50.25
1243     - Host IP: 10.30.51.25
1244     - portnames:
1245         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1246         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1247         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1248         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1249         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1250         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1251         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1252         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1253         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1254         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1255  8. SUT [Server-Type-A1]:
1256     - testbedname: testbed3.
1257     - hostname: t3-sut2.
1258     - CIMC IP: 10.30.50.26
1259     - Host IP: 10.30.51.26
1260     - portnames:
1261         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1262         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1263         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1264         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1265         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1266         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1267         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1268         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1269         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1270         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1271  9. TG [Server-Type-A2]:
1272     - testbedname: testbed3.
1273     - hostname: t3-tg1.
1274     - CIMC IP: 10.30.50.24
1275     - Host IP: 10.30.51.24
1276     - portnames:
1277         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1278         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1279         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1280         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1281         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1282         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1283         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1284         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1285         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1286         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1287         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1288         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1289 ```
1290
1291 #### 3-Node-Skylake Servers (3n-skx) PROD
1292
1293 ```
1294 - ServerB11 [Server-Type-B1]:
1295     - testbedname: testbed31.
1296     - hostname: s11-t31-sut1.
1297     - IPMI IP: 10.30.50.43
1298     - Host IP: 10.30.51.46
1299     - portnames:
1300         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1301         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1302         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1303         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1304         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1305         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1306         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1307         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1308 - ServerB12 [Server-Type-B1]:
1309     - testbedname: testbed31.
1310     - hostname: s12-t31-sut2.
1311     - IPMI IP: 10.30.50.44
1312     - Host IP: 10.30.51.47
1313     - portnames:
1314         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1315         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1316         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1317         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1318         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1319         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1320         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1321         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1322 - ServerB13 [Server-Type-B2]:
1323     - testbedname: testbed31.
1324     - hostname: s13-t31-tg1.
1325     - IPMI IP: 10.30.50.45
1326     - Host IP: 10.30.51.48
1327     - portnames:
1328         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1329         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1330         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1331         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1332         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1333         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1334         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1335         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1336 - ServerB14 [Server-Type-B1]:
1337     - testbedname: testbed32.
1338     - hostname: s14-t32-sut1.
1339     - IPMI IP: 10.30.50.55
1340     - Host IP: 10.30.51.58
1341     - portnames:
1342         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1343         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1344         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1345         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1346         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1347         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1348         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1349         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1350 - ServerB15 [Server-Type-B1]:
1351     - testbedname: testbed32.
1352     - hostname: s15-t32-sut2.
1353     - IPMI IP: 10.30.50.56
1354     - Host IP: 10.30.51.59
1355     - portnames:
1356         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1357         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1358         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1359         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1360         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1361         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1362         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1363         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1364 - ServerB16 [Server-Type-B2]:
1365     - testbedname: testbed32.
1366     - hostname: s16-t32-tg1.
1367     - IPMI IP: 10.30.50.57
1368     - Host IP: 10.30.51.60
1369     - portnames:
1370         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1371         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1372         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1373         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1374         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1375         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1376         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1377         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1378 ```
1379
1380 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1381
1382 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1383
1384 ```
1385 - ServerB22 [Server-Type-B5]:
1386     - testbedname: testbed35.
1387     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1388     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1389     - Host IP: 10.30.51.9
1390     - portnames:
1391         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1392         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1393     - 1GB ports (tbd)
1394 - ServerB23 [Server-Type-B5]:
1395     - testbedname: testbed35.
1396     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1397     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1398     - Host IP: 10.30.51.10
1399     - portnames:
1400         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1401         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1402     - 1GB ports (tbd)
1403 - ServerB24 [Server-Type-B5]:
1404     - testbedname: testbed35.
1405     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1406     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1407     - Host IP: 10.30.51.11
1408     - portnames:
1409         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1410         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1411     - 1GB ports (tbd)
1412 ```
1413
1414 #### 3-Node-Taishan Servers (3n-tsh) PROD
1415
1416 ```
1417 - ServerB17 [Server-Type-B3]:
1418     - testbedname: testbed33.
1419     - hostname: s17-t33-sut1.
1420     - IPMI IP: 10.30.50.36
1421     - Host IP: 10.30.51.36
1422     - portnames:
1423         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1424         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1425         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1426         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1427 - ServerB18 [Server-Type-B3]:
1428     - testbedname: testbed33.
1429     - hostname: s18-t33-sut2.
1430     - IPMI IP: 10.30.50.37
1431     - Host IP: 10.30.51.37
1432     - portnames:
1433         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1434         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1435         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1436         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1437 - ServerB19 [Server-Type-B2]:
1438     - testbedname: testbed33 and testbed34.
1439     - hostname: s19-t33t34-tg1.
1440     - IPMI IP: 10.30.50.46
1441     - Host IP: 10.30.51.49
1442     - portnames:
1443         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1444         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1445         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1446         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1447         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1448         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1449         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1450         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1451         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1452         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1453 ```
1454
1455 #### 3-Node-Denverton Servers (3n-dnv) WIP
1456
1457 ```
1458 - ServerB30 [Server-Type-B10]:
1459     - testbednames: testbed35.
1460     - hostname: s30-t35-sut1.
1461     - IPMI IP: 10.30.55.12
1462     - Host IP: 10.32.8.12
1463     - portnames:
1464         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1465         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1466         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1467         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1468 - ServerB31 [Server-Type-B10]:
1469     - testbednames: testbed35.
1470     - hostname: s31-t35-sut2.
1471     - IPMI IP: 10.30.55.13
1472     - Host IP: 10.32.8.13
1473     - portnames:
1474         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1475         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1476         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1477         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1478 ```
1479
1480 ### Per Testbed Wiring
1481
1482 #### 1-Node-Skylake Wiring (1n-skx) PROD
1483
1484 ```
1485 - testbed11:
1486     - ring1 10GE-ports x710-4p10GE:
1487         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1488     - ring2 10GE-ports x710-4p10GE:
1489         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1490     - ring3 10GE-ports x710-4p10GE:
1491         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1492     - ring4 10GE-ports x710-4p10GE:
1493         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1494 - testbed12:
1495     - ring1 10GE-ports x710-4p10GE:
1496         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1497     - ring2 10GE-ports x710-4p10GE:
1498         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1499     - ring3 10GE-ports x710-4p10GE:
1500         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1501     - ring4 10GE-ports x710-4p10GE:
1502         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1503 ```
1504
1505 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1506
1507 ```
1508 - testbed36:
1509     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1510         - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
1511     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1512         - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
1513     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1514         - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
1515     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1516         - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
1517
1518 - testbed37:
1519     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1520         - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
1521     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1522         - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
1523     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1524         - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
1525     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1526         - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
1527 ```
1528
1529 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1530
1531 ```
1532 - testbed14:
1533     - ring1 10GE-ports x710-4p10GE:
1534         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1535     - ring2 10GE-ports x710-4p10GE:
1536         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1537     - ring3 10GE-ports x710-4p10GE:
1538         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1539     - ring4 10GE-ports x710-4p10GE:
1540         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1541 ```
1542
1543 #### 2-Node-Skylake Wiring (2n-skx) PROD
1544
1545 ```
1546 - testbed21:
1547     - ring1 10GE-ports x710-4p10GE on SUT:
1548         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1549         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1550     - ring2 10GE-ports x710-4p10GE on SUT:
1551         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1552         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1553     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1554         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1555         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1556 - testbed22:
1557     - ring1 10GE-ports x710-4p10GE on SUT:
1558         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1559         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1560     - ring2 10GE-ports x710-4p10GE on SUT:
1561         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1562         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1563     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1564         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1565         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1566 - testbed23:
1567     - ring1 10GE-ports x710-4p10GE on SUT:
1568         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1569         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1570     - ring2 10GE-ports x710-4p10GE on SUT:
1571         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1572         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1573     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1574         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1575         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1576 - testbed24:
1577     - ring1 10GE-ports x710-4p10GE on SUT:
1578         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1579         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1580     - ring2 10GE-ports x710-4p10GE on SUT:
1581         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1582         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1583     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1584         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1585         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1586 ```
1587
1588 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1589
1590 ```
1591 - testbed26:
1592     - ring1 10GE-ports x553 copper port on SUT:
1593         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1594         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1595     - ring2 10GE-ports x553 fiber port on SUT:
1596         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1597         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1598 ```
1599
1600 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1601
1602 ```
1603 - testbed25:
1604     - link1 10GE-port x710-4p10GE on SUT:
1605         - t25-tg1-p1 to t25-sut1-c2/p1.
1606     - link2 10GE-port x710-4p10GE on SUT:
1607         - t25-tg1-p2 to t25-sut1-c2/p2.
1608     - link3 10GE-port x710-4p10GE on SUT:
1609         - t25-tg1-p3 to t25-sut1-c2/p3.
1610     - link4 10GE-port x710-4p10GE on SUT:
1611         - t25-tg1-p4 to t25-sut1-c2/p4.
1612 ```
1613
1614 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1615
1616 ```
1617 - testbed27:
1618     - ring1 10GE-ports x710-4p10GE on SUT:
1619         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1620         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1621     - ring2 10GE-ports x710-4p10GE on SUT:
1622         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1623         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1624     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1625         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1626         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1627     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1628         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1629         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1630 - testbed28:
1631     - ring1 10GE-ports x710-4p10GE on SUT:
1632         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1633         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1634     - ring2 10GE-ports x710-4p10GE on SUT:
1635         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1636         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1637     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1638         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1639         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1640     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1641         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1642         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1643 - testbed29:
1644     - ring1 10GE-ports x710-4p10GE on SUT:
1645         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1646         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1647     - ring2 10GE-ports x710-4p10GE on SUT:
1648         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1649         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1650     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1651         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1652         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1653     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1654         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1655         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1656 ```
1657
1658 #### 2-Node-Zen2 Wiring (2n-zen2) SETUP
1659
1660 ```
1661 - testbed210:
1662     - ring1 10GE-ports x710-4p10GE on SUT:
1663         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1664         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1665     - ring2 10GE-ports x710-4p10GE on SUT:
1666         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1667         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1668     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1669         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1670         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1671     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1672         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1673         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1674 ```
1675
1676 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1677
1678 ```
1679  1. testbed1:
1680     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1681         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1682         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1683         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1684     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1685         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1686         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1687         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1688     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1689         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1690         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1691         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1692     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1693         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1694         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1695         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1696     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1697         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1698         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1699         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1700     - TG loopback ports Intel NIC x710 2p10GE
1701         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1702
1703  2. testbed2:
1704     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1705         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1706         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1707         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1708     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1709         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1710         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1711         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1712     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1713         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1714         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1715         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1716     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1717         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1718         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1719         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1720     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1721         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1722         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1723         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1724     - TG loopback ports Intel NIC x710 2p10GE
1725         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1726
1727  3. testbed3:
1728     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1729         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1730         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1731         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1732     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1733         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1734         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1735         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1736     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1737         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1738         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1739         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1740     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1741         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1742         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1743         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1744     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1745         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1746         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1747         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1748     - TG loopback ports Intel NIC x710 2p10GE
1749         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1750 ```
1751
1752 #### 3-Node-Skylake Wiring (3n-skx) PROD
1753
1754 ```
1755 - testbed31:
1756     - ring1 10GE-ports x710-4p10GE on SUTs:
1757         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1758         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1759         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1760     - ring2 10GE-ports x710-4p10GE on SUT:
1761         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1762         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1763         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1764     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1765         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1766         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1767         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1768     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1769         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1770         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1771         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1772     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1773         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1774         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1775 - testbed32:
1776     - ring1 10GE-ports x710-4p10GE on SUTs:
1777         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1778         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1779         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1780     - ring2 10GE-ports x710-4p10GE on SUT:
1781         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1782         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1783         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1784     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1785         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1786         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1787         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1788     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1789         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1790         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1791         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1792     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1793         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1794         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1795 ```
1796
1797 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1798
1799 ```
1800 To be completed.
1801 ```
1802
1803 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1804
1805 ```
1806 - testbed33:
1807     - ring1 10GE-ports x520-2p10GE on SUTs:
1808         - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1809         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1810         - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
1811     - ring2 25GE-ports cx4-2p25GE on SUTs:
1812         - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1813         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1814         - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
1815 ```
1816
1817 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1818
1819 ```
1820 - testbed35:
1821     - ring1 10GE-ports x553 copper port on SUTs:
1822         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1823         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1824         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1825     - ring2 10GE-ports x553 fiber port on SUTs:
1826         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1827         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1828         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1829 ```
1830
1831 ## Inventory
1832
1833 ### Appliances
1834
1835 ```
1836 1. Ixia PerfectStorm One Appliance
1837     - 1 * PS10GE4NG
1838         - Chassis: PS10GE4NG.
1839         - Motherboard: SuperMicro X11DPG-QT.
1840         - Processors: Quad-Core, Intel Processor.
1841         - HW accelerators: FPGA offload.
1842         - RAM Memory: 64GB.
1843         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1844         - Physical Interfaces: 4 * 10GE SFP+.
1845         - Operating System: Native IxOS.
1846 ```
1847
1848 ### Arm Servers
1849
1850 ```
1851 1. Arm Cortex A-72 servers
1852     - 2 * ThunderX2 (VPP Device)
1853         - Chassis: GIGABYTE Rack Mount
1854         - Processors: 2* ThunderX2 CN9980 ~ 128* ThunderX2
1855         - RAM Memory: 16* 16GB DIMM
1856         - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1857     - 1 * ThunderX2 (Idle)
1858         - Chassis: Marvell ThunderX2
1859         - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1860         - RAM Memory: 4* 32GB RDIMM
1861         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1862     - 2 * Huawei TaiShan 2280.
1863         - Chassis: Huawei TaiShan 2280.
1864         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1865         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1866         - Disks: 1* 4TB SATA HDD.
1867 ```
1868
1869 ### Xeon and Atom Servers
1870
1871 ```
1872 1. Intel Xeon servers:
1873     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1874         - Chassis: SuperMicro SYS-7049GP-TRT.
1875         - Motherboard: SuperMicro X11DPG-QT.
1876         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1877         - RAM Memory: 16* 16GB DDR4-2666MHz.
1878         - Disks: 2* 1.6TB 6G SATA SSD.
1879 2. Intel Atom servers with Rangely processors.
1880     - 3 * Netgate XG-2758-1u
1881         - Chassis: Netgate XG-2758-1u
1882         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1883         - RAM Memory: 16GB ECC
1884         - Disks: 150 GB
1885 ```
1886
1887 ### Network Interface Cards
1888
1889 ```
1890 1. 10GE NICs
1891     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1892     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1893     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1894 2. 25GE NICs
1895     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1896 3. 40GE NICs
1897     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1898 4. 100GE NICs
1899     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1900 ```
1901
1902 ### Pluggables and Cables
1903
1904 Pluggables:
1905
1906 ```
1907 1. 10GE SFP+
1908     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1909     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1910 2. 25GE SFP28
1911     - None
1912 3. 40GE QSFP+
1913     - None
1914 4. 100GE
1915     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1916 ```
1917
1918 Standalone cables:
1919
1920 ```
1921 1. 10GE
1922     - None
1923 2. 25GE
1924     - None
1925 3. 40GE QSFP+
1926     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1927 4. 100GE
1928     - None
1929 ```
1930
1931 ### Other Parts
1932
1933 None.