1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
10 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
11 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
12 1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
13 1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
14 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
15 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16 1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
17 1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
18 1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
19 1. [Server Management](#server-management)
20 1. [Requirements](#requirements)
21 1. [Addressing](#addressing)
22 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25 1. [Server Types](#server-types)
26 1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30 1. [1-Node-ThunderX2 Servers (1n-tx2) PROD](#1-node-thunderx2-servers-1n-tx2-prod)
31 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
33 1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
34 1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
35 1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
36 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
37 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38 1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
39 1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
40 1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
41 1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
42 1. [Per Testbed Wiring](#per-testbed-wiring)
43 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44 1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
45 1. [1-Node-Cascadelake Wiring (1n-clx) PROD](#1-node-cascadelake-wiring-1n-clx-prod)
46 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
48 1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
49 1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
50 1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
51 1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
52 1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
53 1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
54 1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
55 1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
56 1. [Inventory](#inventory)
57 1. [Appliances](#appliances)
58 1. [Arm Servers](#arm-servers)
59 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60 1. [Network Interface Cards](#network-interface-cards)
61 1. [Pluggables and Cables](#pluggables-and-cables)
62 1. [Other Parts](#other-parts)
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
74 #. Type Purpose SUT TG #TB #SUT #TG #skx #ps1 #rng #tx2 #tsh #alt #clx #zn2 #icx #snr
75 1. 1-Node-Skylake nomad skx na 5 5 0 5 0 0 0 0 0 0 0 0 0
76 2. 1-Node-Cascadelake nomad clx na 1 1 0 0 0 0 0 0 0 1 0 0 0
77 3. 1-Node-AmpereAltra nomad alt na 2 2 0 0 0 0 0 0 2 0 0 0 0
78 4. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 1 1 0 0 0 0 0 0 0 0
79 5. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 6 0 0 0
80 6. 2-Node-ThunderX2 perf tx2 skx 1 1 .5 .5 0 0 1 0 0 0 0 0 0
81 7. 2-Node-Icelake perf icx icx 4 4 4 0 0 0 0 0 0 0 0 8 0
82 8. 3-Node-Rangeley perf rng skx 1 3 1 0 0 2 0 0 0 0 0 0 0
83 9. 3-Node-Taishan perf tsh skx 1 2 .5 .5 0 0 0 2 0 0 0 0 0
84 10. 3-Node-Altra perf alt icx 1 2 1 0 0 0 0 0 2 0 0 1 0
85 11. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 2 0 0
86 12. 3-Node-Icelake perf icx icx 2 4 2 0 0 0 0 0 0 0 0 6 0
87 13. 3-Node-SnowRidge perf snr icx 1 2 .5 0 0 0 0 0 0 0 0 .5 2
88 Totals: 23 31 14.5 7 1 2 1 2 4 7 2 15.5 2
91 ### 1-Node-Skylake Xeon Intel (1n-skx)
93 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
94 ports connected back-to-back ([Server Types](#server-types)).
95 Used for FD.io VPP_Device functional driver tests.
97 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
99 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
100 ports connected back-to-back ([Server Types](#server-types)).
101 Used for FD.io VPP_Device functional driver tests.
103 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
105 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
106 NIC ports connected back-to-back ([Server Types](#server-types)).
108 Used for FD.io VPP_Device functional driver tests.
110 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
112 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
113 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
114 circular topology ([Server Types](#server-types)).
115 Used for FD.io TCP/IP and HTTP performance tests.
117 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
119 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
120 one TG (Server-Type-C3) connected in a 2-node circular topology
121 ([Server Types](#server-types)).
122 Used for FD.io performance tests.
124 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
126 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
127 one TG (Server-Type-D2) connected in a 2-node circular topology
128 ([Server Types](#server-types)).
129 Used for FD.io performance tests.
131 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
133 Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
134 one TG (Server-Type-E31) connected in a 2-node circular topology
135 ([Server Types](#server-types)).
136 Used for FD.io performance tests.
138 ### 2-Node-Icelake Xeon Intel (2n-icx)
140 Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
141 one TG (Server-Type-F2) connected in a 2-node circular topology
142 ([Server Types](#server-types)).
143 Used for FD.io performance tests.
145 ### 3-Node-Rangeley Atom Testbeds
147 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
148 TG (Server-Type-2) connected in a 3-node circular topology
149 ([Server Types](#server-types)).
150 Used for FD.io performance tests.
152 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
154 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
155 TG (Server-Type-E31) connected in a 3-node circular topology
156 ([Server Types](#server-types)).
157 Used for FD.io performance tests.
159 ### 3-Node-Altra Arm Ampere (3n-alt)
161 Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
162 TG (Server-Type-F4) connected in a 3-node circular topology
163 ([Server Types](#server-types)).
164 Used for FD.io performance tests.
166 ### 3-Node-Icelake Xeon Intel (3n-icx)
168 Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
169 TG (Server-Type-F3) connected in a 3-node circular topology
170 ([Server Types](#server-types)).
171 Used for FD.io performance tests.
173 ### 3-Node-SnowRidge Atom Intel (3n-snr)
175 Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
176 TG (Server-Type-F4) connected in a 3-node circular topology
177 ([Server Types](#server-types)).
178 Used for FD.io performance tests.
185 For management purposes, each server must have following two ports
186 connected to the management network:
190 - IPMI - Intelligent Platform Management Interface.
191 - Required for access to embedded server management with WebUI, CLI,
192 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
193 - 1GE/10GE/40GE management port
194 - hostOS management port for general system management.
199 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
200 Management port, which are connected to two different VLANs.
204 - Subnet: 10.30.50.0/24
205 - Gateway: 10.30.50.1
206 - Broadcast: 10.30.50.255
207 - DNS1: 199.204.44.24
208 - DNS2: 199.204.47.54
210 - Subnet: 10.30.51.0/24
211 - Gateway: 10.30.51.1
212 - Broadcast: 10.30.51.255
213 - DNS1: 199.204.44.24
214 - DNS2: 199.204.47.54
217 To access these hosts, VPN connection is required.
219 ## Server Specifications
223 FD.io CSIT lab contains following server types:
225 1. Server-Type-B2: Purpose - Skylake Xeon hosts for FD.io builds and data processing.
227 - Physical connectivity:
228 - IPMI and host management ports.
229 - Main HW configuration:
230 - Chassis: SuperMicro SYS-7049GP-TRT.
231 - Motherboard: SuperMicro X11DPG-QT.
232 - Processors: 2* Intel Platinum 8180 2.5 GHz.
233 - RAM Memory: 16* 16GB DDR4-2666MHz.
234 - Disks: 2* 1.6TB 6G SATA SSD.
235 - NICs configuration:
236 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
237 - PCIe Slot2 18:00.xx: empty.
238 - PCIe Slot4 3b:00.xx: empty.
239 - PCIe Slot9 5e:00.xx: empty.
240 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
241 - PCIe Slot6 86:00.xx: empty.
242 - PCIe Slot8 af:00.xx: empty.
243 - PCIe Slot10 d8:00.xx: empty.
244 2. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
246 - Physical connectivity:
247 - IPMI and host management ports.
248 - NIC ports connected into 1-node topologies.
249 - Main HW configuration:
250 - Chassis: SuperMicro SYS-7049GP-TRT.
251 - Motherboard: SuperMicro X11DPG-QT.
252 - Processors: 2* Intel Platinum 8180 2.5 GHz.
253 - RAM Memory: 16* 16GB DDR4-2666MHz.
254 - Disks: 2* 1.6TB 6G SATA SSD.
255 - NICs configuration:
256 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
257 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
258 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
259 - PCIe Slot9 5e:00.xx: empty.
260 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
261 - PCIe Slot6 86:00.xx: empty.
262 - PCIe Slot8 af:00.xx: empty.
263 - PCIe Slot10 d8:00.xx: empty.
264 3. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
266 - Physical connectivity:
267 - Host management interface: 10/100/1000-BaseT.
268 - 8-port 10GE SFP+ integrated NIC.
269 - Main HW configuration:
270 - Chassis: PS10GE4NG.
271 - Motherboard: SuperMicro X11DPG-QT.
272 - Processors: Quad-Core, Intel Processor.
273 - HW accelerators: FPGA offload.
275 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
276 - Physical Interfaces: 4 * 10GE SFP+.
277 - Operating System: Native IxOS.
278 - Interface configuration:
283 4. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
285 - Physical connectivity:
286 - IPMI and host management ports.
288 - Main HW configuration:
289 - Chassis: SuperMicro SYS-7049GP-TRT.
290 - Motherboard: SuperMicro X11DPG-QT.
291 - Processors: 2* Intel Platinum 8180 2.5 GHz.
292 - RAM Memory: 16* 16GB DDR4-2666MHz.
293 - Disks: 2* 1.6TB 6G SATA SSD.
294 - NICs configuration:
295 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
296 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
297 - PCIe Slot4 3b:00.xx: empty.
298 - PCIe Slot9 5e:00.xx: empty.
299 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
300 - PCIe Slot6 86:00.xx: empty.
301 - PCIe Slot8 af:00.xx: empty.
302 - PCIe Slot10 d8:00.xx: empty.
303 5. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
305 - Physical connectivity:
306 - IPMI and host management ports.
307 - NIC ports connected into 1-node testbed topologies.
308 - Main HW configuration:
309 - Chassis: SuperMicro SYS-7049GP-TRT.
310 - Motherboard: SuperMicro X11DPG-QT.
311 - Processors: 2* Intel Platinum 8280 2.7 GHz.
312 - RAM Memory: 12* 16GB DDR4-2933.
313 - Disks: 2* 1.92TB SATA SSD.
314 - NICs configuration:
315 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
316 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
317 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
318 - PCIe Slot9 5e:00.xx: empty.
319 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
320 - PCIe Slot6 86:00.xx: empty.
321 - PCIe Slot8 af:00.xx: empty.
322 - PCIe Slot10 d8:00.xx: empty.
323 6. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
325 - Physical connectivity:
326 - IPMI and host management ports.
327 - NIC ports connected into 2-node testbed topologies.
328 - Main HW configuration:
329 - Chassis: SuperMicro SYS-7049GP-TRT.
330 - Motherboard: SuperMicro X11DPG-QT.
331 - Processors: 2* Intel Gold 6252N 2.3 GHz.
332 - RAM Memory: 12* 16GB DDR4-2933.
333 - Disks: 2* 1.92TB SATA SSD.
334 - NICs configuration:
335 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
336 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
337 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
338 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
339 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
340 - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
341 - PCIe Slot8 af:00.xx: empty.
342 - PCIe Slot10 d8:00.xx: empty.
343 7. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
345 - Physical connectivity:
346 - IPMI and host management ports.
347 - NIC ports connected into 2-node testbed topologies.
348 - Main HW configuration:
349 - Chassis: SuperMicro SYS-7049GP-TRT.
350 - Motherboard: SuperMicro X11DPG-QT.
351 - Processors: 2* Intel Platinum 8280 2.7 GHz.
352 - RAM Memory: 12* 16GB DDR4-2933.
353 - Disks: 2* 1.92TB SATA SSD.
354 - NICs configuration:
355 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
356 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
357 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
358 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
359 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
360 - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
361 - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
362 - PCIe Slot10 d8:00.xx: empty.
363 8. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
365 - Physical connectivity:
366 - IPMI and host management ports.
367 - no NIC ports, standalone setup.
368 - Main HW configuration:
369 - Chassis: SuperMicro 1029P-WTRT.
370 - Motherboard: SuperMicro X11DDW-NT.
371 - Processors: 2* Intel Platinum 8280 2.7 GHz.
372 - RAM Memory: 12* 16GB DDR4-2933.
373 - Disks: 4* 1.92TB SATA SSD.
374 - NICs configuration:
379 9. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
381 - Physical connectivity:
382 - IPMI and host management ports.
383 - NIC ports connected into 2-node testbed topologies.
384 - Main HW configuration:
385 - Chassis: SuperMicro AS-1114S-WTRT
386 - Processors: 1* AMD EPYC 7532 2.4 GHz.
387 - RAM Memory: 8* 32GB DDR4-2933.
388 - Disks: 1* 1TB SATA SSD.
389 - NICs configuration:
390 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
391 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
392 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
393 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
394 10. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
396 - Physical connectivity:
397 - IPMI and host management ports.
398 - NIC ports connected into 2-node testbed topologies.
399 - Main HW configuration:
400 - Chassis: SuperMicro AS-1114S-WTRT
401 - Processors: 1* AMD EPYC 7532 2.4 GHz.
402 - RAM Memory: 8* 32GB DDR4-2933.
403 - Disks: 1* 1TB SATA SSD.
404 - NICs configuration:
405 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
406 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
407 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
408 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
409 11. Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
411 - Physical connectivity:
412 - IPMI and host management ports.
413 - NIC ports connected into 1-node topologies.
414 - Main HW configuration:
415 - Chassis: GIGABYTE Rack Mount
416 - Motherboard: MT91-FS4-00
417 - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
418 - RAM Memory: 16 * 16GB DIMM
419 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
420 - NICs configuration:
422 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
423 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
425 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
426 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
427 12. Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
429 - Physical connectivity:
430 - IPMI(?) and host management ports.
431 - NIC ports connected into 3-node topology.
432 - Main HW configuration:
433 - Chassis: Huawei TaiShan 2280.
434 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
435 - RAM Memory: 8* 16GB DDR4-2400MT/s
436 - Disks: 1* 4TB SATA HDD
437 - NICs configuration:
438 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
439 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
440 13. Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
442 - Physical connectivity:
443 - IPMI and host management ports.
444 - NIC ports connected into 2-node topologies.
445 - Main HW configuration:
446 - Chassis: Gigabyte R181-T90 1U
447 - Motherboard: MT91-FS1
448 - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
449 - RAM Memory: 4* 32GB RDIMM
450 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
451 - NICs configuration:
455 - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
456 14. Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
458 - Physical connectivity:
459 - IPMI and host management ports.
460 - NIC ports connected into 3-node topologies.
461 - Main HW configuration:
462 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
463 - Motherboard: Mt.Jade Motherboard
464 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
465 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
466 - RAM Memory: 16* 8GB DDR4-3200MT/s
467 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
468 - NICs configuration:
470 - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
473 15. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
475 - Physical connectivity:
476 - IPMI and host management ports.
477 - Main HW configuration:
478 - Chassis: Gigabyte R152-P30-00 1U
479 - Motherboard: MP32-AR1-00
480 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
481 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
482 - RAM Memory: 12* 16GB DDR4-3200MT/s
483 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
484 16. Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
486 - Physical connectivity:
487 - IPMI and host management ports.
488 - NIC ports connected into 2-node and 3-node topologies.
489 - Main HW configuration:
490 - Chassis: SuperMicro SYS-7049GP-TRT.
491 - Motherboard: SuperMicro X11DPG-QT.
492 - Processors: 2* Intel Platinum 8180 2.5 GHz.
493 - RAM Memory: 16* 16GB DDR4-2666MHz.
494 - Disks: 2* 1.6TB 6G SATA SSD.
495 - NICs configuration:
496 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
497 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
498 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
499 - PCIe Slot9 5e:00.xx: empty.
500 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
501 - PCIe Slot6 86:00.xx: empty.
502 - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
503 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
504 17. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
506 - Physical connectivity:
507 - IPMI and host management ports.
508 - NIC ports connected into 2-node or 3-node testbed topologies.
509 - Main HW configuration:
510 - Chassis: SuperMicro SYS-740GP-TNRT.
511 - Motherboard: Super X12DPG-QT6.
512 - Processors: 2* Intel Platinum 8358 2.6 GHz.
513 - RAM Memory: 16* 16GB DDR4-3200.
514 - Disks: 2* 960GB SATA SSD.
515 - NICs configuration:
516 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
517 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
518 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
519 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
520 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
521 - PCIe Slot6 86:00.xx: empty.
522 - PCIe Slot8 af:00.xx: empty.
523 - PCIe Slot10 d8:00.xx: empty.
524 18. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
526 - Physical connectivity:
527 - IPMI and host management ports.
528 - NIC ports connected into 2-node testbed topologies.
529 - Main HW configuration:
530 - Chassis: SuperMicro SYS-740GP-TNRT.
531 - Motherboard: Super X12DPG-QT6.
532 - Processors: 2* Intel Platinum 8358 2.6 GHz.
533 - RAM Memory: 16* 16GB DDR4-3200.
534 - Disks: 2* 960GB SATA SSD.
535 - NICs configuration:
536 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
537 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
538 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
539 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
540 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
541 - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
542 - PCIe Slot8 af:00.xx: empty.
543 - PCIe Slot10 d8:00.xx: empty.
544 19. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
546 - Physical connectivity:
547 - IPMI and host management ports.
548 - NIC ports connected into 3-node testbed topologies.
549 - Main HW configuration:
550 - Chassis: SuperMicro SYS-740GP-TNRT.
551 - Motherboard: Super X12DPG-QT6.
552 - Processors: 2* Intel Platinum 8358 2.6 GHz.
553 - RAM Memory: 16* 16GB DDR4-3200.
554 - Disks: 2* 960GB SATA SSD.
555 - NICs configuration:
556 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
557 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
558 - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
559 - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
560 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
561 - PCIe Slot6 86:00.xx: empty.
562 - PCIe Slot8 af:00.xx: empty.
563 - PCIe Slot10 d8:00.xx: empty.
564 20. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
566 - Physical connectivity:
567 - IPMI and host management ports.
568 - NIC ports connected into 2-node and/or 3-node testbed topologies.
569 - Main HW configuration:
570 - Chassis: SuperMicro SYS-740GP-TNRT.
571 - Motherboard: Super X12DPG-QT6.
572 - Processors: 2* Intel Platinum 8358 2.6 GHz.
573 - RAM Memory: 16* 16GB DDR4-3200.
574 - Disks: 2* 960GB SATA SSD.
575 - NICs configuration:
576 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
577 - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
578 - PCIe Slot4 3b:00.xx: empty.
579 - PCIe Slot9 5e:00.xx: empty.
580 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
581 - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
582 - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
583 - PCIe Slot10 d8:00.xx: empty.
584 21. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
586 - Physical connectivity:
587 - IPMI and host management ports.
588 - NIC ports connected into 3-node testbed topology.
589 - Main HW configuration:
590 - Chassis: Intel JACOBSVILLE SDP.
591 - Motherboard: Intel JACOBSVILLE E63448-400.
592 - Processors: 1* Intel Atom P5362B 2.2 GHz.
593 - RAM Memory: 2* 16GB DDR4-2933.
594 - Disks: ?* ? SATA SSD.
595 - NICs configuration:
596 - Numa0: (x16, PCIe3.0 lane)
597 - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
600 ### Naming Convention
602 Following naming convention is used within this page to specify physical
603 connectivity and wiring across defined CSIT testbeds:
606 - testbedname: testbedN.
608 - traffic-generator: tN-tgW.
609 - system-under-testX: tN-sutX.
614 - N - testbed number.
615 - tgW - server acts as traffic-generator with W index.
616 - sutX - server acts as system-under-test with X index.
617 - Y - PCIe slot number denoting a NIC card number within the host.
618 - Z - port number on the NIC card.
621 ## Testbeds Configuration
623 ### Per Testbed Server Allocation and Naming
625 #### 1-Node-Skylake Servers (1n-skx) PROD
628 - SUT [Server-Type-B6]:
629 - testbedname: testbed11.
630 - hostname: s1-t11-sut1.
631 - IPMI IP: 10.30.50.47
632 - Host IP: 10.30.51.50
634 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
635 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
636 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
637 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
638 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
639 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
640 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
641 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
642 - SUT [Server-Type-B6]:
643 - testbedname: testbed12.
644 - hostname: s2-t12-sut1.
645 - IPMI IP: 10.30.50.48
646 - Host IP: 10.30.51.51
648 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
649 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
650 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
651 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
652 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
653 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
654 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
655 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
658 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
661 - SUT [Server-Type-E11]:
662 - testbedname: testbed13
663 - hostname: s55-t13-sut1
664 - IPMI IP: 10.30.50.70
665 - Host IP: 10.30.51.70
667 - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
668 - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
669 - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
670 - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
671 - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
672 - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
673 - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
674 - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
675 - SUT [Server-Type-E11]:
676 - testbedname: testbed14
677 - hostname: s56-t14-sut1
678 - IPMI IP: 10.30.50.71
679 - Host IP: 10.30.51.71
681 - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
682 - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
683 - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
684 - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
685 - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
686 - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
687 - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
688 - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
691 #### 1-Node-Cascadelake Servers (1n-clx) PROD
694 - SUT [Server-Type-C1]:
695 - testbedname: testbed11.
696 - hostname: s32-t14-sut1.
697 - IPMI IP: 10.30.55.17
698 - Host IP: 10.32.8.17
700 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
701 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
702 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
703 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
704 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
705 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
706 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
707 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
710 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
713 - SUT [Server-Type-B8]:
714 - testbedname: testbed25.
715 - hostname: s25-t25-sut1.
716 - IPMI IP: 10.30.50.58
717 - Host IP: 10.30.51.61
719 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
720 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
721 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
722 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
723 - TG [Server-Type-B7]:
724 - testbedname: testbed25.
725 - hostname: s26-t25-tg1.
726 - IPMI IP: 10.30.50.59
727 - Host IP: 10.30.51.62
729 - s26-t25-tg1-p1 - 10GE-port1.
730 - s26-t25-tg1-p2 - 10GE-port2.
731 - s26-t25-tg1-p3 - 10GE-port3.
732 - s26-t25-tg1-p4 - 10GE-port4.
735 #### 2-Node-Cascadelake Servers (2n-clx) PROD
738 - SUT [Server-Type-C2]:
739 - testbedname: testbed27.
740 - hostname: s33-t27-sut1.
741 - IPMI IP: 10.30.55.18
742 - Host IP: 10.32.8.18
744 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
745 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
746 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
747 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
748 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
749 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
750 - s33-t27-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
751 - s33-t27-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
752 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
753 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
754 - TG [Server-Type-C3]:
755 - testbedname: testbed27.
756 - hostname: s34-t27-tg1.
757 - IPMI IP: 10.30.55.19
758 - Host IP: 10.32.8.19
760 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
761 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
762 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
763 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
764 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
765 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
766 - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
767 - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
768 - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
769 - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
770 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
771 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
772 - SUT [Server-Type-C2]:
773 - testbedname: testbed28.
774 - hostname: s35-t28-sut1.
775 - IPMI IP: 10.30.55.20
776 - Host IP: 10.32.8.20
778 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
779 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
780 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
781 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
782 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
783 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
784 - s35-t28-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
785 - s35-t28-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
786 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
787 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
788 - TG [Server-Type-C3]:
789 - testbedname: testbed28.
790 - hostname: s36-t28-tg1.
791 - IPMI IP: 10.30.55.21
792 - Host IP: 10.32.8.21
794 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
795 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
796 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
797 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
798 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
799 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
800 - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
801 - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
802 - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
803 - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
804 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
805 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
806 - SUT [Server-Type-C2]:
807 - testbedname: testbed29.
808 - hostname: s37-t29-sut1.
809 - IPMI IP: 10.30.55.22
810 - Host IP: 10.32.8.22
812 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
813 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
814 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
815 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
816 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
817 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
818 - s37-t29-sut1-c6/p1 - 100GE-port1 e810-2p100GE.
819 - s37-t29-sut1-c6/p2 - 100GE-port2 e810-2p100GE.
820 - s37-t29-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
821 - s37-t29-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
822 - TG [Server-Type-C3]:
823 - testbedname: testbed29.
824 - hostname: s38-t29-tg1.
825 - IPMI IP: 10.30.55.23
826 - Host IP: 10.32.8.23
828 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
829 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
830 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
831 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
832 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
833 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
834 - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
835 - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
836 - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
837 - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
840 #### 2-Node-Zen2 Servers (2n-zn2) PROD
843 - SUT [Server-Type-D1]:
844 - testbedname: testbed210.
845 - hostname: s60-t210-sut1.
846 - IPMI IP: 10.30.55.24
847 - Host IP: 10.32.8.24
849 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
850 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
851 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
852 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
853 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
854 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
855 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
856 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
857 - TG [Server-Type-D2]:
858 - testbedname: testbed210.
859 - hostname: s61-t210-tg1.
860 - IPMI IP: 10.30.55.25
861 - Host IP: 10.32.8.25
863 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
864 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
865 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
866 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
867 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
868 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
869 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
870 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
873 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
875 Note: Server19 (TG) is shared between testbed33 & testbed211
878 - SUT [Server-Type-E22]:
879 - testbedname: testbed211.
880 - hostname: s27-t211-sut1.
881 - IPMI IP: 10.30.50.69
882 - Host IP: 10.30.51.69
884 - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
885 - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
886 - TG [Server-Type-E31]:
887 - testbedname: testbed33 and testbed211.
888 - hostname: s19-t33t211-tg1.
889 - IPMI IP: 10.30.50.46
890 - Host IP: 10.30.51.49
892 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
893 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
894 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
895 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
896 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
897 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
898 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
899 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
900 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
901 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
902 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
903 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
906 #### 2-Node-Icelake Servers (2n-icx) PROD
909 - SUT [Server-Type-F1]:
910 - testbedname: testbed212.
911 - hostname: s71-t212-sut1.
912 - IPMI IP: 10.30.51.81
913 - Host IP: 10.30.50.81
915 - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
916 - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
917 - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
918 - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
919 - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
920 - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
921 - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
922 - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
923 - TG [Server-Type-F2]:
924 - testbedname: testbed212.
925 - hostname: s72-t212-tg1.
926 - IPMI IP: 10.30.51.82
927 - Host IP: 10.30.50.82
929 - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
930 - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
931 - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
932 - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
933 - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
934 - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
935 - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
936 - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
937 - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
938 - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
939 - SUT [Server-Type-F1]:
940 - testbedname: testbed213.
941 - hostname: s83-t213-sut1.
942 - IPMI IP: 10.30.51.83
943 - Host IP: 10.30.50.83
945 - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
946 - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
947 - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
948 - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
949 - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
950 - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
951 - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
952 - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
953 - TG [Server-Type-F2]:
954 - testbedname: testbed213.
955 - hostname: s84-t213-tg1.
956 - IPMI IP: 10.30.51.84
957 - Host IP: 10.30.50.84
959 - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
960 - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
961 - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
962 - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
963 - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
964 - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
965 - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
966 - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
967 - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
968 - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
969 - SUT [Server-Type-F1]:
970 - testbedname: testbed214.
971 - hostname: s85-t214-sut1.
972 - IPMI IP: 10.30.51.85
973 - Host IP: 10.30.50.85
975 - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
976 - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
977 - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
978 - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
979 - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
980 - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
981 - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
982 - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
983 - TG [Server-Type-F2]:
984 - testbedname: testbed214.
985 - hostname: s86-t214-tg1.
986 - IPMI IP: 10.30.51.86
987 - Host IP: 10.30.50.86
989 - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
990 - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
991 - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
992 - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
993 - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
994 - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
995 - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
996 - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
997 - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
998 - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
999 - SUT [Server-Type-F1]:
1000 - testbedname: testbed215.
1001 - hostname: s87-t215-sut1.
1002 - IPMI IP: 10.30.51.87
1003 - Host IP: 10.30.50.87
1005 - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1006 - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1007 - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1008 - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1009 - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1010 - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1011 - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1012 - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1013 - TG [Server-Type-F2]:
1014 - testbedname: testbed215.
1015 - hostname: s88-t215-tg1.
1016 - IPMI IP: 10.30.51.88
1017 - Host IP: 10.30.50.88
1019 - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1020 - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1021 - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1022 - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1023 - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1024 - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1025 - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1026 - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1027 - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1028 - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1031 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1033 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1036 - ServerB22 [Server-Type-B5]:
1037 - testbedname: testbed35.
1038 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1039 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1040 - Host IP: 10.30.51.9
1042 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1043 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1045 - ServerB23 [Server-Type-B5]:
1046 - testbedname: testbed35.
1047 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1048 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1049 - Host IP: 10.30.51.10
1051 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1052 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1054 - ServerB24 [Server-Type-B5]:
1055 - testbedname: testbed35.
1056 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1057 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1058 - Host IP: 10.30.51.11
1060 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1061 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1065 #### 3-Node-Taishan Servers (3n-tsh) PROD
1067 Note: Server19 (TG) is shared between testbed33 & testbed211
1070 - SUT [Server-Type-E21]:
1071 - testbedname: testbed33.
1072 - hostname: s17-t33-sut1.
1073 - IPMI IP: 10.30.50.36
1074 - Host IP: 10.30.51.36
1076 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1077 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1078 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1079 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1080 - SUT [Server-Type-E21]:
1081 - testbedname: testbed33.
1082 - hostname: s18-t33-sut2.
1083 - IPMI IP: 10.30.50.37
1084 - Host IP: 10.30.51.37
1086 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1087 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1088 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1089 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1090 - TG [Server-Type-E31]:
1091 - testbedname: testbed33 and testbed211.
1092 - hostname: s19-t33t211-tg1.
1093 - IPMI IP: 10.30.50.46
1094 - Host IP: 10.30.51.49
1096 - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1097 - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1098 - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1099 - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1100 - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1101 - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1102 - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1103 - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1104 - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1105 - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1106 - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1107 - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1110 #### 3-Node-Altra Servers (3n-alt) PROD
1113 - SUT [Server-Type-E23]:
1114 - testbedname: testbed34.
1115 - hostname: s62-t34-sut1.
1116 - IPMI IP: 10.30.50.72
1117 - Host IP: 10.30.51.72
1119 - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1120 - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1121 - SUT [Server-Type-E23]:
1122 - testbedname: testbed34.
1123 - hostname: s63-t34-sut2.
1124 - IPMI IP: 10.30.50.73
1125 - Host IP: 10.30.51.73
1127 - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1128 - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1129 - TG [Server-Type-F4]:
1130 - testbedname: testbed34.
1131 - hostname: s64-t34-tg1.
1132 - IPMI IP: 10.30.50.74
1133 - Host IP: 10.30.51.74
1135 - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1136 - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1137 - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
1138 - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
1139 - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1140 - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1141 - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1142 - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1143 - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1144 - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1147 #### 3-Node-Icelake Servers (3n-icx) PROD
1150 - ServerF1 [Server-Type-F1]:
1151 - testbedname: testbed37.
1152 - hostname: s65-t37-sut1.
1153 - IPMI IP: 10.30.50.75
1154 - Host IP: 10.30.51.75
1156 - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1157 - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1158 - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1159 - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1160 - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1161 - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1162 - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1163 - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1164 - ServerF1 [Server-Type-F1]:
1165 - testbedname: testbed37.
1166 - hostname: s66-t37-sut2.
1167 - IPMI IP: 10.30.50.76
1168 - Host IP: 10.30.51.76
1170 - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1171 - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1172 - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1173 - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1174 - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1175 - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1176 - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1177 - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1178 - ServerF3 [Server-Type-F3]:
1179 - testbedname: testbed37.
1180 - hostname: s67-t37-tg1.
1181 - IPMI IP: 10.30.50.77
1182 - Host IP: 10.30.51.77
1184 - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1185 - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1186 - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1187 - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1188 - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1189 - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1190 - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1191 - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1192 - ServerF1 [Server-Type-F1]:
1193 - testbedname: testbed38.
1194 - hostname: s78-t38-sut1.
1195 - IPMI IP: 10.30.50.78
1196 - Host IP: 10.30.51.78
1198 - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1199 - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1200 - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1201 - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1202 - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1203 - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1204 - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1205 - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1206 - ServerF1 [Server-Type-F1]:
1207 - testbedname: testbed38.
1208 - hostname: s79-t38-sut2.
1209 - IPMI IP: 10.30.50.79
1210 - Host IP: 10.30.51.79
1212 - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1213 - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1214 - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1215 - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1216 - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1217 - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1218 - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1219 - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1220 - ServerF3 [Server-Type-F3]:
1221 - testbedname: testbed38.
1222 - hostname: s80-t38-tg1.
1223 - IPMI IP: 10.30.50.80
1224 - Host IP: 10.30.51.80
1226 - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1227 - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1228 - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1229 - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1230 - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1231 - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1232 - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
1233 - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
1236 #### 3-Node-SnowRidge Servers (3n-snr) PROD
1239 - ServerG1 [Server-Type-G1]:
1240 - testbedname: testbed39.
1241 - hostname: s93-t39-sut1.
1242 - IPMI IP: 10.30.50.93
1243 - Host IP: 10.30.51.93
1245 - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1246 - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1247 - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
1248 - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
1249 - ServerG1 [Server-Type-G1]:
1250 - testbedname: testbed39.
1251 - hostname: s94-t39-sut2.
1252 - IPMI IP: 10.30.50.94
1253 - Host IP: 10.30.51.94
1255 - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1256 - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1257 - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1258 - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1259 - ServerF4 [Server-Type-F4]:
1260 - testbedname: testbed39.
1261 - hostname: s89-t39t310-tg1.
1262 - IPMI IP: 10.30.50.89
1263 - Host IP: 10.30.51.89
1265 - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
1266 - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
1267 - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
1268 - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
1271 ### Per Testbed Wiring
1273 #### 1-Node-Skylake Wiring (1n-skx) PROD
1277 - ring1 10GE-ports x710-4p10GE:
1278 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1279 - ring2 10GE-ports x710-4p10GE:
1280 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1281 - ring3 10GE-ports x710-4p10GE:
1282 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1283 - ring4 10GE-ports x710-4p10GE:
1284 - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
1285 - ring5 100GE-ports e810-2p100GE:
1286 - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
1287 - ring6 100GE-ports e810-2p100GE:
1288 - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
1290 - ring1 10GE-ports x710-4p10GE:
1291 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1292 - ring2 10GE-ports x710-4p10GE:
1293 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1294 - ring3 10GE-ports x710-4p10GE:
1295 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1296 - ring4 10GE-ports x710-4p10GE:
1297 - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
1298 - ring5 100GE-ports e810-2p100GE:
1299 - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
1300 - ring6 100GE-ports e810-2p100GE:
1301 - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
1304 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
1308 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1309 - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
1310 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1311 - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
1312 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1313 - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
1314 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1315 - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
1318 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1319 - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
1320 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1321 - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
1322 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1323 - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
1324 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1325 - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
1328 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1332 - link1 10GE-port x710-4p10GE on SUT:
1333 - t25-tg1-p1 to t25-sut1-c2/p1.
1334 - link2 10GE-port x710-4p10GE on SUT:
1335 - t25-tg1-p2 to t25-sut1-c2/p2.
1336 - link3 10GE-port x710-4p10GE on SUT:
1337 - t25-tg1-p3 to t25-sut1-c2/p3.
1338 - link4 10GE-port x710-4p10GE on SUT:
1339 - t25-tg1-p4 to t25-sut1-c2/p4.
1342 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1346 - ring1 10GE-ports x710-4p10GE on SUT:
1347 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1348 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1349 - ring2 10GE-ports x710-4p10GE on SUT:
1350 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1351 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1352 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1353 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1354 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1355 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1356 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1357 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1358 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1359 - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
1360 - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
1361 - ring6 100GE-ports e810-2p100GE on TG:
1362 - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
1363 - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
1365 - ring1 10GE-ports x710-4p10GE on SUT:
1366 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1367 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1368 - ring2 10GE-ports x710-4p10GE on SUT:
1369 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1370 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1371 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1372 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1373 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1374 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1375 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1376 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1377 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1378 - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
1379 - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
1380 - ring6 100GE-ports e810-2p100GE on TG:
1381 - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
1382 - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
1384 - ring1 10GE-ports x710-4p10GE on SUT:
1385 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1386 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1387 - ring2 10GE-ports x710-4p10GE on SUT:
1388 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1389 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1390 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1391 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1392 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1393 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1394 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1395 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1396 - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
1397 - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
1398 - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
1401 #### 2-Node-Zen2 Wiring (2n-zn2) PROD
1405 - ring1 10GE-ports x710-4p10GE on SUT:
1406 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1407 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1408 - ring2 10GE-ports x710-4p10GE on SUT:
1409 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1410 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1411 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1412 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1413 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1414 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1415 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1416 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1419 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
1423 - ring1 10GE-ports x520-2p10GE on SUTs:
1424 - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
1425 - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
1428 #### 2-Node-Icelake Wiring (2n-icx) PROD
1432 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1433 - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
1434 - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
1435 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1436 - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
1437 - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
1438 - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
1439 - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
1440 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1441 - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
1442 - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
1443 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1444 - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
1445 - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
1447 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1448 - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
1449 - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
1450 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1451 - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
1452 - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
1453 - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
1454 - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
1455 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1456 - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
1457 - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
1458 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1459 - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
1460 - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
1462 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1463 - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
1464 - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
1465 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1466 - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
1467 - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
1468 - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
1469 - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
1470 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1471 - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
1472 - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
1473 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1474 - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
1475 - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
1477 - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
1478 - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
1479 - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
1480 - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
1481 - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
1482 - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
1483 - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
1484 - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
1485 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
1486 - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
1487 - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
1488 - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
1489 - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
1490 - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
1493 #### 3-Node-Rangeley Wiring (3n-rng) VERIFY
1499 #### 3-Node-Taishan Wiring (3n-tsh) PROD
1503 - ring1 10GE-ports x520-2p10GE on SUTs:
1504 - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
1505 - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
1506 - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
1507 - ring2 25GE-ports cx4-2p25GE on SUTs:
1508 - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
1509 - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
1510 - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
1513 #### 3-Node-Altra Wiring (3n-alt) PROD
1517 - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
1518 - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
1519 - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
1520 - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
1523 #### 3-Node-Icelake Wiring (3n-icx) PROD
1527 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1528 - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
1529 - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
1530 - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
1531 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1532 - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
1533 - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
1534 - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
1535 - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
1536 - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
1537 - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
1538 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1539 - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
1540 - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
1541 - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
1543 - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
1544 - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
1545 - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
1546 - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
1547 - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
1548 - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
1549 - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
1550 - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
1551 - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
1552 - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
1553 - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
1554 - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
1555 - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
1556 - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
1557 - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
1560 #### 3-Node-SnowRidge Wiring (3n-snr) PROD
1564 - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
1565 - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
1566 - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
1567 - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
1568 - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
1569 - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
1570 - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
1578 1. Ixia PerfectStorm One Appliance
1580 - Chassis: PS10GE4NG.
1581 - Motherboard: SuperMicro X11DPG-QT.
1582 - Processors: Quad-Core, Intel Processor.
1583 - HW accelerators: FPGA offload.
1585 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1586 - Physical Interfaces: 4 * 10GE SFP+.
1587 - Operating System: Native IxOS.
1593 1. Arm Cortex A-72 servers
1594 - 2 * ThunderX2 (VPP Device)
1595 - Chassis: GIGABYTE Rack Mount
1596 - Processors: 2* ThunderX2 CN9980 ~ 32* ThunderX2
1597 - RAM Memory: 16* 16GB DIMM
1598 - Disks: 2* 480GB 6G SATA SSD SAMSUNG MZ7LH480
1599 - 1 * ThunderX2 (Performance)
1600 - Chassis: GIGABYTE Rack Mount
1601 - Processors: 2* ThunderX2 CN9975 ~ 28* ThunderX2.
1602 - RAM Memory: 4* 32GB RDIMM
1603 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1604 - 2 * Huawei TaiShan 2280.
1605 - Chassis: Huawei TaiShan 2280.
1606 - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
1607 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1608 - Disks: 1* 4TB SATA HDD.
1609 2. Arm Neoverse N1 servers
1610 - 2 * Ampere Altra (Performance)
1611 - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
1612 - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
1613 - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
1614 - RAM Memory: 16* 8GB DDR4-3200MT/s
1615 - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
1616 - 2 * Ampere Altra (Build)
1617 - Chassis: Gigabyte R152-P30-00 1U
1618 - Motherboard: MP32-AR1-00
1619 - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
1620 - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
1621 - RAM Memory: 12* 16GB DDR4-3200MT/s
1622 - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
1625 ### Xeon and Atom Servers
1628 1. Intel Xeon servers:
1629 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1630 - Chassis: SuperMicro SYS-7049GP-TRT.
1631 - Motherboard: SuperMicro X11DPG-QT.
1632 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1633 - RAM Memory: 16* 16GB DDR4-2666MHz.
1634 - Disks: 2* 1.6TB 6G SATA SSD.
1635 2. Intel Atom servers with Rangely processors.
1636 - 3 * Netgate XG-2758-1u
1637 - Chassis: Netgate XG-2758-1u
1638 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1639 - RAM Memory: 16GB ECC
1643 ### Network Interface Cards
1656 ### Pluggables and Cables