Update 1n-tx2 testbed docs for new thx2 servers
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
15    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17    1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
18    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
19 1. [Server Management](#server-management)
20    1. [Requirements](#requirements)
21    1. [Addressing](#addressing)
22    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25    1. [Server Types](#server-types)
26    1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30       1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
31       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
33       1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
34       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
35       1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
36       1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup])
37       1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
38       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
39       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
40       1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
41       1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
42    1. [Per Testbed Wiring](#per-testbed-wiring)
43       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44       1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
45       1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
46       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
47       1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
48       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
49       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
50       1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup])
51       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
52       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
53       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
54       1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
55       1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
56 1. [Inventory](#inventory)
57    1. [Appliances](#appliances)
58    1. [Arm Servers](#arm-servers)
59    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60    1. [Network Interface Cards](#network-interface-cards)
61    1. [Pluggables and Cables](#pluggables-and-cables)
62    1. [Other Parts](#other-parts)
63
64 ## Purpose
65
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
68
69 ## Testbeds Overview
70
71 ### Summary List
72
73 ```
74  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb #clx #zn2
75  1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0    0    0
76  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0
77  3. 1-Node-Thunderx2   idle   tx2   na    1    1    0    0    0    0    0    0    1    0    0    0    0
78  4. 1-Node-Thunderx2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0
79  5. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0
80  6. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0    0
81  7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0
82  8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0
83  9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0
84 10. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0    0    0
85 11. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0
86 12. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0
87 13. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0    0    0
88 14. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2    0    0
89 15. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0
90 16. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2
91                                  Totals: 28   38   18   12   19    1    2    3    3    2    2    7    2
92 ```
93
94 ### 1-Node-Skylake Xeon Intel (1n-skx)
95
96 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
97 ports connected back-to-back ([Server Types](#server-types)).
98 Used for FD.io VPP_Device functional driver tests.
99
100 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
101
102 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
103 ports connected back-to-back ([Server Types](#server-types)).
104 Used for FD.io VPP_Device functional driver tests.
105
106 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
107
108 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
109 NIC ports connected back-to-back ([Server Types](#server-types)).
110
111 Used for FD.io VPP_Device functional driver tests.
112
113 ### 2-Node-Skylake Xeon Intel (2n-skx)
114
115 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
116 (Server-Type-B2) connected in a 2-node circular topology
117 ([Server Types](#server-types)).
118 Used for FD.io performance tests.
119
120 ### 2-Node-Denverton Atom Intel (2n-dnv)
121
122 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
123 TG (Server-Type-B2) connected in a 2-node circular topology
124 ([Server Types](#server-types)).
125 Used for FD.io performance tests.
126
127 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
128
129 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
130 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
131 circular topology ([Server Types](#server-types)).
132 Used for FD.io TCP/IP and HTTP performance tests.
133
134 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
135
136 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
137 one TG (Server-Type-C3) connected in a 2-node circular topology
138 ([Server Types](#server-types)).
139 Used for FD.io performance tests.
140
141 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
142
143 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
144 one TG (Server-Type-D2) connected in a 2-node circular topology
145 ([Server Types](#server-types)).
146 Used for FD.io performance tests.
147
148 ### 3-Node-Haswell Xeon Intel (3n-hsw)
149
150 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
151 TG (Server-Type-A2) connected in a 3-node circular topology
152 ([Server Types](#server-types)).
153 Used for FD.io performance tests.
154
155 ### 3-Node-Skylake Xeon Intel (3n-skx)
156
157 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
158 TG (Server-Type-B2) connected in a 3-node circular topology.
159 Used for FD.io performance tests.
160
161 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
162
163 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
164 TG (Server-Type-B2) connected in a 3-node circular topology
165 ([Server Types](#server-types)).
166 Used for FD.io performance tests.
167
168 ### 3-Node-MACCHIATObin Arm Marvell
169
170 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
171 one TG (Server-Type-B2) connected in a 3-node circular topology
172 ([Server Types](#server-types)).
173 Used for FD.io performance tests.
174
175 ### 3-Node-Rangeley Atom Testbeds
176
177 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
178 TG (Server-Type-2) connected in a 3-node circular topology
179 ([Server Types](#server-types)).
180 Used for FD.io performance tests.
181
182 ## Server Management
183
184 ### Requirements
185
186 For management purposes, each server must have following two ports
187 connected to the management network:
188
189 ```
190 - 1GE IPMI port
191   - IPMI - Intelligent Platform Management Interface.
192   - Required for access to embedded server management with WebUI, CLI,
193     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
194 - 1GE/10GE/40GE management port
195   - hostOS management port for general system management.
196 ```
197
198 ### Addressing
199
200 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
201 Management port, which are connected to two different VLANs.
202
203 ```
204 1. LOM (IPMI) VLAN:
205     - Subnet: 10.30.50.0/24
206     - Gateway: 10.30.50.1
207     - Broadcast: 10.30.50.255
208     - DNS1: 199.204.44.24
209     - DNS2: 199.204.47.54
210 2. Management Vlan:
211     - Subnet: 10.30.51.0/24
212     - Gateway: 10.30.51.1
213     - Broadcast: 10.30.51.255
214     - DNS1: 199.204.44.24
215     - DNS2: 199.204.47.54
216 ```
217
218 To access these hosts, VPN connection is required.
219
220 ### LOM (IPMI) VLAN IP Addresses
221
222 Name         | Comment
223 ------------ | -------
224 10.30.50.0   | network
225 10.30.51.1   | Router
226 10.30.50.2   | LF Reserved
227 10.30.50.3   | LF Reserved
228 10.30.50.4   | LF Reserved
229 10.30.50.5   | LF Reserved
230 10.30.50.6   | LF Reserved
231 10.30.50.7   | LF Reserved
232 10.30.50.8   | LF Reserved
233 10.30.50.9   | LF Reserved
234 10.30.50.10  | LF Reserved
235 10.30.50.11  | LF Reserved
236 10.30.50.12  | LF Reserved
237 10.30.50.13  | LF Reserved
238 10.30.50.14  | LF Reserved
239 10.30.50.15  | LF Reserved
240 10.30.50.16  | t1-tg1
241 10.30.50.17  | t1-sut1
242 10.30.50.18  | t1-sut2
243 10.30.50.20  | t2-tg1
244 10.30.50.21  | t2-sut1
245 10.30.50.22  | t2-sut2
246 10.30.50.24  | t3-tg1
247 10.30.50.25  | t3-sut1
248 10.30.50.26  | t3-sut-2
249 10.30.50.28  | s41-nomad
250 10.30.50.29  | s39-nomad
251 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
252 10.30.50.30  | s40-nomad
253 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
254 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
255 10.30.50.32  | s42-nomad (formerly nomad1)
256 10.30.50.33  | s43-nomad (formerly nomad2)
257 10.30.50.34  | s44-nomad (formerly nomad3)
258 10.30.50.35  | s45-nomad (formerly nomad4)
259 10.30.50.36  | s17-t33-sut1
260 10.30.50.37  | s18-t33-sut2
261 10.30.50.38  | fdio-marvell-dev
262 10.30.50.39  | s53-nomad
263 10.30.50.40  | s54-nomad
264 10.30.50.41  | s3-t21-sut1
265 10.30.50.42  | s4-t21-tg1
266 10.30.50.43  | s11-t31-sut1
267 10.30.50.44  | s12-t31-sut2
268 10.30.50.45  | s13-t31-tg1
269 10.30.50.46  | s19-t33t34-tg1
270 10.30.50.47  | s1-t11-sut1
271 10.30.50.48  | s2-t12-sut1
272 10.30.50.49  | s5-t22-sut1
273 10.30.50.50  | s6-t22-tg1
274 10.30.50.51  | s7-t23-sut1
275 10.30.50.52  | s8-t23-tg1
276 10.30.50.53  | s9-t24-sut1
277 10.30.50.54  | s10-t24-tg1
278 10.30.50.55  | s14-t32-sut1
279 10.30.50.56  | s15-t32-sut2
280 10.30.50.57  | s16-t32-tg1
281 10.30.50.58  | s25-t25-sut1
282 10.30.50.59  | s26-t25-tg1
283 10.30.50.65  | s52-nomad
284 10.30.50.66  | s51-nomad (out of order)
285 10.30.50.67  | s49-nomad
286 10.30.50.68  | s50-nomad (out of order)
287 10.30.50.69  | s27-t13-sut
288 10.30.50.70  | s55-t36-sut1
289 10.30.50.71  | s56-t37-sut1
290 10.30.50.255 | Broadcast
291 n/a          | s20-t34-sut1
292 n/a          | s21-t34-sut2
293 10.30.55.0   | network
294 10.30.55.1   | Router
295 10.30.55.10  | s28-t26t35-tg1
296 10.30.55.11  | s29-t26-sut1
297 10.30.55.12  | s30-t35-sut1
298 10.30.55.13  | s31-t35-sut2
299 10.30.55.14  | s46-nomad (formerly server-type-c4-1)
300 10.30.55.15  | s47-nomad (formerly server-type-c4-2)
301 10.30.55.16  | s48-nomad (formerly server-type-c4-3)
302 10.30.55.17  | s32-t14-sut1
303 10.30.55.18  | s33-t27-sut1
304 10.30.55.19  | s34-t27-tg1
305 10.30.55.20  | s35-t28-sut1
306 10.30.55.21  | s36-t28-tg1
307 10.30.55.22  | s37-t29-sut1
308 10.30.55.23  | s38-t29-tg1
309 10.30.55.24  | s60-t210-sut1
310 10.30.55.25  | s61-t210-tg1
311 10.30.55.255 | Broadcast
312
313 ### Management VLAN IP Addresses
314
315 Name                      | Comment
316 ------------------------- | -------
317 10.30.51.0                | network
318 10.30.51.1                | Router
319 10.30.51.2                | LF Reserved
320 10.30.51.3                | LF Reserved
321 10.30.51.4                | LF Reserved
322 10.30.51.5                | LF Reserved
323 10.30.51.6                | LF Reserved
324 10.30.51.7                | LF Reserved
325 10.30.51.8                | LF Reserved
326 10.30.51.9                | s22-t35-sut1 (netgate-1)
327 10.30.51.10               | s23-t35-sut2 (netgate-2)
328 10.30.51.11               | s24-t35-sut3 (netgate-3)
329 10.30.51.12               | softiron-1
330 10.30.51.13               | softiron-2
331 10.30.51.14               | softiron-3
332 10.30.51.15               | LF Reserved
333 10.30.51.16               | t1-tg1
334 10.30.51.17               | t1-sut1
335 10.30.51.18               | t1-sut2
336 10.30.51.20               | t2-tg1
337 10.30.51.21               | t2-sut1
338 10.30.51.22               | t2-sut2
339 10.30.51.24               | t3-tg1
340 10.30.51.25               | t3-sut1
341 10.30.51.26               | t3-sut-2
342 10.30.51.28               | s41-nomad
343 10.30.51.29               | s39-nomad
344 10.30.51.30               | s40-nomad
345 10.30.51.32               | s42-nomad (formerly nomad1)
346 10.30.51.33               | s43-nomad (formerly nomad2)
347 10.30.51.34               | s44-nomad (formerly nomad3)
348 10.30.51.35               | s45-nomad (formerly nomad4)
349 10.30.51.36               | s17-t33-sut1
350 10.30.51.37               | s18-t33-sut2
351 10.30.51.38               | fdio-marvell-dev
352 10.30.51.39               | s53-nomad
353 10.30.51.40               | s54-nomad
354 10.30.51.41               | s20-t34-sut1
355 10.30.51.42               | s21-t34-sut2
356 10.30.51.44               | s3-t21-sut1
357 10.30.51.45               | s4-t21-tg1
358 10.30.51.46               | s11-t31-sut1
359 10.30.51.47               | s12-t31-sut2
360 10.30.51.48               | s13-t31-tg1
361 10.30.51.49               | s19-t33t34-tg1
362 10.30.51.50               | s1-t11-sut1
363 10.30.51.51               | s2-t12-sut1
364 10.30.51.52               | s5-t22-sut1
365 10.30.51.53               | s6-t22-tg1
366 10.30.51.54               | s7-t23-sut1
367 10.30.51.55               | s8-t23-tg1
368 10.30.51.56               | s9-t24-sut1
369 10.30.51.57               | s10-t24-tg1
370 10.30.51.58               | s14-t32-sut1
371 10.30.51.59               | s15-t32-sut2
372 10.30.51.60               | s16-t32-tg1
373 10.30.51.61               | s25-t25-sut1
374 10.30.51.62               | s26-t25-tg1
375 10.30.51.65               | s52-nomad
376 10.30.51.66               | s51-nomad
377 10.30.51.67               | s49-nomad
378 10.30.51.68               | s50-nomad
379 10.30.51.69               | s27-t13-sut1
380 10.30.51.70               | s55-t36-sut1
381 10.30.51.71               | s56-t37-sut1
382 10.30.51.72-10.30.51.105  | FREE
383 10.30.51.106-10.30.51.180 | FREE
384 10.30.51.181-10.30.51.254 | FREE
385 10.30.51.255              | Broadcast
386 10.32.8.0                 | network
387 10.32.8.1                 | Router
388 10.32.8.10                | s28-t26t35-tg1
389 10.32.8.11                | s29-t26-sut1
390 10.32.8.12                | s30-t35-sut1
391 10.32.8.13                | s31-t35-sut2
392 10.32.8.14                | s46-nomad (formerly server-type-c4-1)
393 10.32.8.15                | s47-nomad (formerly server-type-c4-2)
394 10.32.8.16                | s48-nomad (formerly server-type-c4-3)
395 10.32.8.17                | s32-t14-sut1
396 10.32.8.18                | s33-t27-sut1
397 10.32.8.19                | s34-t27-tg1
398 10.32.8.20                | s35-t28-sut1
399 10.32.8.21                | s36-t28-tg1
400 10.32.8.22                | s37-t29-sut1
401 10.32.8.23                | s38-t29-tg1
402 10.32.8.24                | s60-t210-sut1
403 10.32.8.25                | s61-t210-tg1
404 10.32.8.255               | Broadcast
405
406 ## Server Specifications
407
408 ### Server Types
409
410 FD.io CSIT lab contains following server types:
411 ```
412 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
413     - Quantity: 6 servers.
414     - Physical connectivity:
415         - CIMC and host management ports.
416         - NIC ports connected in 3-node topologies.
417     - Main HW configuration:
418         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
419         - Processors: 2* E5-2699v3 2.3 GHz.
420         - RAM Memory: 16* 32GB DDR4-2133MHz.
421         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
422     - NICs configuration:
423         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
424             - PCIe Slot1: Cisco VIC 1385 2p40GE.
425             - PCIe Slot2: Intel NIC x520 2p10GE.
426             - PCIe Slot3: empty.
427         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
428             - PCIe Slot4: Intel NIC xl710 2p40GE.
429             - PCIe Slot5: Intel NIC x710 2p10GE.
430             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
431         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
432 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
433     - Quantity: 3 servers.
434     - Physical connectivity:
435         - CIMC and host management ports.
436         - NIC ports connected in 3-node topologies.
437     - Main HW configuration:
438         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
439         - Processors: 2* E5-2699v3 2.3 GHz.
440         - RAM Memory: 16* 32GB DDR4-2133MHz.
441         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
442     - NICs configuration:
443         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
444             - PCIe Slot1: Intel NIC xl710 2p40GE.
445             - PCIe Slot2: Intel NIC x710 2p10GE.
446             - PCIe Slot3: Intel NIC x710 2p10GE.
447         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
448             - PCIe Slot4: Intel NIC xl710 2p40GE.
449             - PCIe Slot5: Intel NIC x710 2p10GE.
450             - PCIe Slot6: Intel NIC x710 2p10GE.
451         - MLOM slot: empty.
452 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
453     - Quantity: 3 servers.
454     - Physical connectivity:
455         - CIMC and host management ports.
456         - no NIC ports, standalone setup.
457     - Main HW configuration:
458         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
459         - Processors: 2* E5-2699v3 2.3 GHz.
460         - RAM Memory: 16* 32GB DDR4-2133MHz.
461         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
462     - NICs configuration:
463         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
464             - no cards.
465         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
466             - no cards.
467         - MLOM slot: empty.
468 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
469     - Quantity: ---
470     - Physical connectivity:
471         - IPMI and host management ports.
472         - NIC ports connected into 2-node and 3-node topologies.
473     - Main HW configuration:
474         - Chassis: SuperMicro SYS-7049GP-TRT.
475         - Motherboard: SuperMicro X11DPG-QT.
476         - Processors: 2* Intel Platinum 8180 2.5 GHz.
477         - RAM Memory: 16* 16GB DDR4-2666MHz.
478         - Disks: 2* 1.6TB 6G SATA SSD.
479     - NICs configuration:
480         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
481             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
482             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
483             - PCIe Slot9 5e:00.xx: empty.
484         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
485             - PCIe Slot6 86:00.xx: empty.
486             - PCIe Slot8 af:00.xx: empty.
487             - PCIe Slot10 d8:00.xx: empty.
488 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
489     - Quantity: ---
490     - Physical connectivity:
491         - IPMI and host management ports.
492         - NIC ports connected into 2-node and 3-node topologies.
493     - Main HW configuration:
494         - Chassis: SuperMicro SYS-7049GP-TRT.
495         - Motherboard: SuperMicro X11DPG-QT.
496         - Processors: 2* Intel Platinum 8180 2.5 GHz.
497         - RAM Memory: 16* 16GB DDR4-2666MHz.
498         - Disks: 2* 1.6TB 6G SATA SSD.
499     - NICs configuration:
500         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
501             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
502             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
503             - PCIe Slot9 5e:00.xx: empty.
504         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
505             - PCIe Slot6 86:00.xx: empty.
506             - PCIe Slot8 af:00.xx: empty.
507             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
508 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
509     - Quantity: 2
510     - Physical connectivity:
511         - IPMI(?) and host management ports.
512         - NIC ports connected into 3-node topology.
513     - Main HW configuration:
514         - Chassis: Huawei TaiShan 2280.
515         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
516         - RAM Memory: 8* 16GB DDR4-2400MT/s
517         - Disks: 1* 4TB SATA HDD
518     - NICs configuration:
519         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
520         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
521 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
522     - Quantity: 3
523     - Physical connectivity:
524         - Host management ports.
525         - NIC ports connected into 2-node and 3-node topologies.
526     - Main HW configuration:
527         - Chassis: MACCHIATObin.
528         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
529         - RAM Memory: 1* 16GB DDR4
530         - Disks: 1* 128GB(?) SATA SDD
531     - NICs configuration:
532         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
533 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
534     - Quantity: TBD based on testbed allocation.
535     - Physical connectivity:
536         - Management: serial Port (usb) for console
537         - NIC ports connected into 2-node.
538     - Main HW configuration:
539         - Chassis: Netgate XG-2758-1u
540         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
541         - RAM Memory: 16GB ECC
542         - Disks: 150 GB
543     - NICs configuration:
544         - 2x 10Gb Intel 82599ES
545         - 4x 1GB Intel I354
546 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
547     - Quantity: 2.
548     - Physical connectivity:
549         - IPMI and host management ports.
550         - NIC ports connected into 1-node topologies.
551     - Main HW configuration:
552         - Chassis: SuperMicro SYS-7049GP-TRT.
553         - Motherboard: SuperMicro X11DPG-QT.
554         - Processors: 2* Intel Platinum 8180 2.5 GHz.
555         - RAM Memory: 16* 16GB DDR4-2666MHz.
556         - Disks: 2* 1.6TB 6G SATA SSD.
557     - NICs configuration:
558         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
559             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
560             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
561             - PCIe Slot9 5e:00.xx: empty.
562         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
563             - PCIe Slot6 86:00.xx: empty.
564             - PCIe Slot8 af:00.xx: empty.
565             - PCIe Slot10 d8:00.xx: empty.
566 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
567     - Quantity: 1.
568     - Physical connectivity:
569         - Host management interface: 10/100/1000-BaseT.
570         - 8-port 10GE SFP+ integrated NIC.
571     - Main HW configuration:
572         - Chassis: PS10GE4NG.
573         - Motherboard: SuperMicro X11DPG-QT.
574         - Processors: Quad-Core, Intel Processor.
575         - HW accelerators: FPGA offload.
576         - RAM Memory: 64GB.
577         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
578         - Physical Interfaces: 4 * 10GE SFP+.
579         - Operating System: Native IxOS.
580     - Interface configuration:
581         - Port-1: 10GE SFP+.
582         - Port-2: 10GE SFP+.
583         - Port-3: 10GE SFP+.
584         - Port-4: 10GE SFP+.
585 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
586     - Quantity: 1.
587     - Physical connectivity:
588         - IPMI and host management ports.
589         - NIC ports.
590     - Main HW configuration:
591         - Chassis: SuperMicro SYS-7049GP-TRT.
592         - Motherboard: SuperMicro X11DPG-QT.
593         - Processors: 2* Intel Platinum 8180 2.5 GHz.
594         - RAM Memory: 16* 16GB DDR4-2666MHz.
595         - Disks: 2* 1.6TB 6G SATA SSD.
596     - NICs configuration:
597         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
598             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
599             - PCIe Slot4 3b:00.xx: empty.
600             - PCIe Slot9 5e:00.xx: empty.
601         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
602             - PCIe Slot6 86:00.xx: empty.
603             - PCIe Slot8 af:00.xx: empty.
604             - PCIe Slot10 d8:00.xx: empty.
605 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell(Idle).
606     - Quantity: 1
607     - Physical connectivity:
608         - IPMI and host management ports.
609         - NIC ports connected into 1-node topologies.
610     - Main HW configuration:
611         - Chassis: Gigabyte R181-T90 1U
612         - Motherboard: MT91-FS1
613         - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
614         - RAM Memory: 4* 32GB RDIMM
615         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
616     - NICs configuration:
617         - Numa0:
618             - PCIe Slot1 05:00.xx: XL710-QDA2.
619             - PCIe Slot3 08:00.xx: XL710-QDA2.
620         - Numa1:
621             - PCIe Slot6 85:00.xx: XL710-QDA2.
622 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
623     - Quantity: 4
624     - Physical connectivity:
625         - IPMI and host management ports.
626         - NIC ports.
627     - Main HW configuration:
628         - Chassis: SuperMicro SYS-E300-9A
629         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
630         - RAM Memory: 32GB ECC
631         - Disks: 480 GB
632     - NICs configuration:
633         - 2x 10Gb Intel x553 fiber ports
634         - 2x 10Gb Intel x553 copper ports
635         - 4x 1GB Intel I350 ports
636
637 14. Server-Type-B11: Purpose - Thunderx2 Arm Marvell SUT for FD.io VPP_Device functional tests.
638     - Quantity: 2
639     - Physical connectivity:
640         - IPMI and host management ports.
641         - NIC ports connected into 1-node topologies.
642     - Main HW configuration:
643         - Chassis: GIGABYTE Rack Mount
644         - Motherboard: MT91-FS4-00
645         - Processors: 2 * Thunderx2 ARMv8 CN9980 2.20 GHz
646         - RAM Memory: 16 * 16GB DIMM
647         - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
648     - NICs configuration:
649         - Numa0:
650             - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
651             - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
652         - Numa1:
653             - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
654             - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
655
656 15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
657     - Quantity: 1.
658     - Physical connectivity:
659         - IPMI and host management ports.
660         - NIC ports connected into 1-node testbed topologies.
661     - Main HW configuration:
662         - Chassis: SuperMicro SYS-7049GP-TRT.
663         - Motherboard: SuperMicro X11DPG-QT.
664         - Processors: 2* Intel Platinum 8280 2.7 GHz.
665         - RAM Memory: 12* 16GB DDR4-2933.
666         - Disks: 2* 1.92TB SATA SSD.
667     - NICs configuration:
668         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
669             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
670             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
671             - PCIe Slot9 5e:00.xx: empty.
672         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
673             - PCIe Slot6 86:00.xx: empty.
674             - PCIe Slot8 af:00.xx: empty.
675             - PCIe Slot10 d8:00.xx: empty.
676
677 16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
678     - Quantity: 3
679     - Physical connectivity:
680         - IPMI and host management ports.
681         - NIC ports connected into 2-node testbed topologies.
682     - Main HW configuration:
683         - Chassis: SuperMicro SYS-7049GP-TRT.
684         - Motherboard: SuperMicro X11DPG-QT.
685         - Processors: 2* Intel Gold 6252N 2.3 GHz.
686         - RAM Memory: 12* 16GB DDR4-2933.
687         - Disks: 2* 1.92TB SATA SSD.
688     - NICs configuration:
689         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
690             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
691             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
692             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
693         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
694             - PCIe Slot6 86:00.xx: empty.
695             - PCIe Slot8 af:00.xx: empty.
696             - PCIe Slot10 d8:00.xx: empty.
697 17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
698     - Quantity: 3.
699     - Physical connectivity:
700         - IPMI and host management ports.
701         - NIC ports connected into 2-node testbed topologies.
702     - Main HW configuration:
703         - Chassis: SuperMicro SYS-7049GP-TRT.
704         - Motherboard: SuperMicro X11DPG-QT.
705         - Processors: 2* Intel Platinum 8280 2.7 GHz.
706         - RAM Memory: 12* 16GB DDR4-2933.
707         - Disks: 2* 1.92TB SATA SSD.
708     - NICs configuration:
709         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
710             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
711             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
712             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
713         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
714             - PCIe Slot6 86:00.xx: empty.
715             - PCIe Slot8 af:00.xx: empty.
716             - PCIe Slot10 d8:00.xx: empty.
717
718 18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
719     - Quantity: 3.
720     - Physical connectivity:
721         - CIMC and host management ports.
722         - no NIC ports, standalone setup.
723     - Main HW configuration:
724         - Chassis: SuperMicro 1029P-WTRT.
725         - Motherboard: SuperMicro X11DDW-NT.
726         - Processors: 2* Intel Platinum 8280 2.7 GHz.
727         - RAM Memory: 12* 16GB DDR4-2933.
728         - Disks: 4* 1.92TB SATA SSD.
729     - NICs configuration:
730         - Numa0:
731             - no cards.
732         - Numa1:
733             - no cards.
734 19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
735     - Quantity: 1.
736     - Physical connectivity:
737         - IPMI and host management ports.
738         - NIC ports connected into 2-node testbed topologies.
739     - Main HW configuration:
740         - Chassis: SuperMicro AS-1114S-WTRT
741         - Processors: 1* AMD EPYC 7532 2.4 GHz.
742         - RAM Memory: 8* 32GB DDR4-2933.
743         - Disks: 1* 1TB SATA SSD.
744     - NICs configuration:
745         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
746             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
747             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
748             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
749 20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
750     - Quantity: 1.
751     - Physical connectivity:
752         - IPMI and host management ports.
753         - NIC ports connected into 2-node testbed topologies.
754     - Main HW configuration:
755         - Chassis: SuperMicro AS-1114S-WTRT
756         - Processors: 1* AMD EPYC 7532 2.4 GHz.
757         - RAM Memory: 8* 32GB DDR4-2933.
758         - Disks: 1* 1TB SATA SSD.
759     - NICs configuration:
760         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
761             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
762             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
763             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
764 ```
765
766 ### Naming Convention
767
768 Following naming convention is used within this page to specify physical
769 connectivity and wiring across defined CSIT testbeds:
770
771 ```
772 - testbedname: testbedN.
773 - hostname:
774     - traffic-generator: tN-tgW.
775     - system-under-testX: tN-sutX.
776 - portnames:
777     - tN-tgW-cY/pZ.
778     - tN-sutX-cY/pZ.
779 - where:
780     - N - testbed number.
781     - tgW - server acts as traffic-generator with W index.
782     - sutX - server acts as system-under-test with X index.
783     - Y - PCIe slot number denoting a NIC card number within the host.
784     - Z - port number on the NIC card.
785 ```
786
787 ## Testbeds Configuration
788
789 ### Per Testbed Server Allocation and Naming
790
791 #### 1-Node-Skylake Servers (1n-skx) PROD
792
793 ```
794 - SUT [Server-Type-B6]:
795     - testbedname: testbed11.
796     - hostname: s1-t11-sut1.
797     - IPMI IP: 10.30.50.47
798     - Host IP: 10.30.51.50
799     - portnames:
800         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
801         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
802         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
803         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
804         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
805         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
806         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
807         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
808 - SUT [Server-Type-B6]:
809     - testbedname: testbed12.
810     - hostname: s2-t12-sut1.
811     - IPMI IP: 10.30.50.48
812     - Host IP: 10.30.51.51
813     - portnames:
814         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
815         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
816         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
817         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
818         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
819         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
820         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
821         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
822 ```
823
824 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
825
826 ```
827 - SUT [Server-Type-B11]:
828     - testbedname: testbed36
829     - hostname: s55-t36-sut1
830     - IPMI IP: 10.30.50.70
831     - Host IP: 10.30.51.70
832     - portnames:
833         - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
834         - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
835         - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
836         - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
837         - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
838         - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
839         - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
840         - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
841
842 - SUT [Server-Type-B11]:
843     - testbedname: testbed37
844     - hostname: s56-t37-sut1
845     - IPMI IP: 10.30.50.71
846     - Host IP: 10.30.51.71
847     - portnames:
848         - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
849         - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
850         - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
851         - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
852         - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
853         - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
854         - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
855         - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
856 ```
857
858 #### 1-Node-Cascadelake Servers (1n-clx) PROD
859
860 ```
861 - SUT [Server-Type-C1]:
862     - testbedname: testbed11.
863     - hostname: s32-t14-sut1.
864     - IPMI IP: 10.30.55.17
865     - Host IP: 10.32.8.17
866     - portnames:
867         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
868         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
869         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
870         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
871         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
872         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
873         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
874         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
875 ```
876
877 #### 2-Node-Skylake Servers (2n-skx) PROD
878
879 ```
880 - SUT [Server-Type-B1]:
881     - testbedname: testbed21.
882     - hostname: s3-t21-sut1.
883     - IPMI IP: 10.30.50.41
884     - Host IP: 10.30.51.44
885     - portnames:
886         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
887         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
888         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
889         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
890         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
891         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
892 - TG [Server-Type-B2]:
893     - testbedname: testbed21.
894     - hostname: s4-t21-tg1.
895     - IPMI IP: 10.30.50.42
896     - Host IP: 10.30.51.45
897     - portnames:
898         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
899         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
900         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
901         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
902         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
903         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
904 - SUT [Server-Type-B1]:
905     - testbedname: testbed22.
906     - hostname: s5-t22-sut1.
907     - IPMI IP: 10.30.50.49
908     - Host IP: 10.30.51.52
909     - portnames:
910         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
911         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
912         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
913         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
914         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
915         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
916 - TG [Server-Type-B2]:
917     - testbedname: testbed22.
918     - hostname: s6-t22-tg1.
919     - IPMI IP: 10.30.50.50
920     - Host IP: 10.30.51.53
921     - portnames:
922         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
923         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
924         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
925         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
926         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
927         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
928 - SUT [Server-Type-B1]:
929     - testbedname: testbed23.
930     - hostname: s7-t23-sut1.
931     - IPMI IP: 10.30.50.51
932     - Host IP: 10.30.51.54
933     - portnames:
934         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
935         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
936         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
937         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
938         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
939         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
940 - TG [Server-Type-B2]:
941     - testbedname: testbed23.
942     - hostname: s8-t23-tg1.
943     - IPMI IP: 10.30.50.52
944     - Host IP: 10.30.51.55
945     - portnames:
946         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
947         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
948         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
949         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
950         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
951         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
952 - SUT [Server-Type-B1]:
953     - testbedname: testbed24.
954     - hostname: s9-t24-sut1.
955     - IPMI IP: 10.30.50.53
956     - Host IP: 10.30.51.56
957     - portnames:
958         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
959         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
960         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
961         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
962         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
963         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
964 - TG [Server-Type-B2]:
965     - testbedname: testbed24.
966     - hostname: s10-t24-tg1.
967     - IPMI IP: 10.30.50.54
968     - Host IP: 10.30.51.57
969     - portnames:
970         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
971         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
972         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
973         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
974         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
975         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
976 ```
977
978 #### 2-Node-Denverton Servers (2n-dnv) WIP
979
980 Note: ServerB28 (TG) is shared between testbed26 & testbed35
981
982 ```
983 - TG [Server-Type-B2]:
984     - testbednames: testbed26 and testbed35.
985     - hostname: s28-t26t35-tg1.
986     - IPMI IP: 10.30.55.10
987     - Host IP: 10.32.8.10
988     - portnames:
989         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
990         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
991         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
992         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
993         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
994         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
995         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
996         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
997         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
998         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
999         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1000         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1001 - SUT [Server-Type-B10]:
1002     - testbednames: testbed26.
1003     - hostname: s29-t26-sut1.
1004     - IPMI IP: 10.30.55.11
1005     - Host IP: 10.32.8.11
1006     - portnames:
1007         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1008         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1009         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1010         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1011 ```
1012
1013 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1014
1015 ```
1016 - SUT [Server-Type-B8]:
1017     - testbedname: testbed25.
1018     - hostname: s25-t25-sut1.
1019     - IPMI IP: 10.30.50.58
1020     - Host IP: 10.30.51.61
1021     - portnames:
1022         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1023         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1024         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1025         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1026 - TG [Server-Type-B7]:
1027     - testbedname: testbed25.
1028     - hostname: s26-t25-tg1.
1029     - IPMI IP: 10.30.50.59
1030     - Host IP: 10.30.51.62
1031     - portnames:
1032         - s26-t25-tg1-p1 - 10GE-port1.
1033         - s26-t25-tg1-p2 - 10GE-port2.
1034         - s26-t25-tg1-p3 - 10GE-port3.
1035         - s26-t25-tg1-p4 - 10GE-port4.
1036 ```
1037
1038 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
1039
1040 ```
1041 - SUT [Server-Type-C2]:
1042     - testbedname: testbed27.
1043     - hostname: s33-t27-sut1.
1044     - IPMI IP: 10.30.55.18
1045     - Host IP: 10.32.8.18
1046     - portnames:
1047         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1048         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1049         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1050         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1051         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1052         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1053         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1054         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1055 - TG [Server-Type-C3]:
1056     - testbedname: testbed27.
1057     - hostname: s34-t27-tg1.
1058     - IPMI IP: 10.30.55.19
1059     - Host IP: 10.32.8.19
1060     - portnames:
1061         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1062         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1063         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1064         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1065         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1066         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1067         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1068         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1069 - SUT [Server-Type-C2]:
1070     - testbedname: testbed28.
1071     - hostname: s35-t28-sut1.
1072     - IPMI IP: 10.30.55.20
1073     - Host IP: 10.32.8.20
1074     - portnames:
1075         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1076         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1077         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1078         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1079         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1080         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1081         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1082         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1083 - TG [Server-Type-C3]:
1084     - testbedname: testbed28.
1085     - hostname: s36-t28-tg1.
1086     - IPMI IP: 10.30.55.21
1087     - Host IP: 10.32.8.21
1088     - portnames:
1089         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1090         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1091         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1092         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1093         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1094         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1095         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1096         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1097 - SUT [Server-Type-C2]:
1098     - testbedname: testbed29.
1099     - hostname: s37-t29-sut1.
1100     - IPMI IP: 10.30.55.22
1101     - Host IP: 10.32.8.22
1102     - portnames:
1103         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1104         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1105         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1106         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1107         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1108         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1109         - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1110         - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1111 - TG [Server-Type-C3]:
1112     - testbedname: testbed29.
1113     - hostname: s38-t29-tg1.
1114     - IPMI IP: 10.30.55.23
1115     - Host IP: 10.32.8.23
1116     - portnames:
1117         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1118         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1119         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1120         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1121         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1122         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1123         - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1124         - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1125 ```
1126
1127 #### 2-Node-Zen2 Servers (2n-zn2) SETUP
1128
1129 ```
1130 - SUT [Server-Type-D1]:
1131     - testbedname: testbed210.
1132     - hostname: s60-t210-sut1.
1133     - IPMI IP: 10.30.55.24
1134     - Host IP: 10.32.8.24
1135     - portnames:
1136         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1137         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1138         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1139         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1140         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1141         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1142         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1143         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1144 - TG [Server-Type-D2]:
1145     - testbedname: testbed210.
1146     - hostname: s61-t210-tg1.
1147     - IPMI IP: 10.30.55.25
1148     - Host IP: 10.32.8.25
1149     - portnames:
1150         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1151         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1152         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1153         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1154         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1155         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1156         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1157         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1158 ```
1159
1160 #### 3-Node-Haswell Servers (3n-hsw) PROD
1161
1162 ```
1163  1. SUT [Server-Type-A1]:
1164     - testbedname: testbed1.
1165     - hostname: t1-sut1.
1166     - CIMC IP: 10.30.50.17
1167     - Host IP: 10.30.51.17
1168     - portnames:
1169         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1170         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1171         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1172         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1173         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1174         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1175         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1176         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1177         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1178         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1179  2. SUT [Server-Type-A1]:
1180     - testbedname: testbed1.
1181     - hostname: t1-sut2.
1182     - CIMC IP: 10.30.50.18
1183     - Host IP: 10.30.51.18
1184     - portnames:
1185         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1186         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1187         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1188         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1189         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1190         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1191         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1192         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1193         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1194         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1195  3. TG [Server-Type-A2]:
1196     - testbedname: testbed1.
1197     - hostname: t1-tg1.
1198     - CIMC IP: 10.30.50.16
1199     - Host IP: 10.30.51.16
1200     - portnames:
1201         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1202         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1203         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1204         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1205         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1206         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1207         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1208         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1209         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1210         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1211         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1212         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1213  4. SUT [Server-Type-A1]:
1214     - testbedname: testbed2.
1215     - hostname: t2-sut1.
1216     - CIMC IP: 10.30.50.21
1217     - Host IP: 10.30.51.21
1218     - portnames:
1219         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1220         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1221         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1222         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1223         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1224         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1225         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1226         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1227         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1228         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1229  5. SUT [Server-Type-A1]:
1230     - testbedname: testbed2.
1231     - hostname: t2-sut2.
1232     - CIMC IP: 10.30.50.22
1233     - Host IP: 10.30.51.22
1234     - portnames:
1235         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1236         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1237         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1238         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1239         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1240         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1241         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1242         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1243         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1244         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1245  6. TG [Server-Type-A2]:
1246     - testbedname: testbed2.
1247     - hostname: t2-tg1.
1248     - CIMC IP: 10.30.50.20
1249     - Host IP: 10.30.51.20
1250     - portnames:
1251         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1252         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1253         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1254         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1255         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1256         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1257         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1258         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1259         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1260         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1261         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1262         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1263  7. SUT [Server-Type-A1]:
1264     - testbedname: testbed3.
1265     - hostname: t3-sut1.
1266     - CIMC IP: 10.30.50.25
1267     - Host IP: 10.30.51.25
1268     - portnames:
1269         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1270         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1271         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1272         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1273         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1274         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1275         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1276         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1277         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1278         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1279  8. SUT [Server-Type-A1]:
1280     - testbedname: testbed3.
1281     - hostname: t3-sut2.
1282     - CIMC IP: 10.30.50.26
1283     - Host IP: 10.30.51.26
1284     - portnames:
1285         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1286         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1287         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1288         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1289         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1290         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1291         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1292         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1293         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1294         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1295  9. TG [Server-Type-A2]:
1296     - testbedname: testbed3.
1297     - hostname: t3-tg1.
1298     - CIMC IP: 10.30.50.24
1299     - Host IP: 10.30.51.24
1300     - portnames:
1301         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1302         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1303         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1304         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1305         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1306         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1307         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1308         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1309         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1310         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1311         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1312         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1313 ```
1314
1315 #### 3-Node-Skylake Servers (3n-skx) PROD
1316
1317 ```
1318 - ServerB11 [Server-Type-B1]:
1319     - testbedname: testbed31.
1320     - hostname: s11-t31-sut1.
1321     - IPMI IP: 10.30.50.43
1322     - Host IP: 10.30.51.46
1323     - portnames:
1324         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1325         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1326         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1327         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1328         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1329         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1330         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1331         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1332 - ServerB12 [Server-Type-B1]:
1333     - testbedname: testbed31.
1334     - hostname: s12-t31-sut2.
1335     - IPMI IP: 10.30.50.44
1336     - Host IP: 10.30.51.47
1337     - portnames:
1338         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1339         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1340         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1341         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1342         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1343         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1344         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1345         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1346 - ServerB13 [Server-Type-B2]:
1347     - testbedname: testbed31.
1348     - hostname: s13-t31-tg1.
1349     - IPMI IP: 10.30.50.45
1350     - Host IP: 10.30.51.48
1351     - portnames:
1352         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1353         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1354         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1355         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1356         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1357         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1358         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1359         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1360 - ServerB14 [Server-Type-B1]:
1361     - testbedname: testbed32.
1362     - hostname: s14-t32-sut1.
1363     - IPMI IP: 10.30.50.55
1364     - Host IP: 10.30.51.58
1365     - portnames:
1366         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1367         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1368         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1369         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1370         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1371         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1372         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1373         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1374 - ServerB15 [Server-Type-B1]:
1375     - testbedname: testbed32.
1376     - hostname: s15-t32-sut2.
1377     - IPMI IP: 10.30.50.56
1378     - Host IP: 10.30.51.59
1379     - portnames:
1380         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1381         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1382         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1383         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1384         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1385         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1386         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1387         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1388 - ServerB16 [Server-Type-B2]:
1389     - testbedname: testbed32.
1390     - hostname: s16-t32-tg1.
1391     - IPMI IP: 10.30.50.57
1392     - Host IP: 10.30.51.60
1393     - portnames:
1394         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1395         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1396         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1397         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1398         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1399         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1400         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1401         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1402 ```
1403
1404 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1405
1406 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1407
1408 ```
1409 - ServerB22 [Server-Type-B5]:
1410     - testbedname: testbed35.
1411     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1412     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1413     - Host IP: 10.30.51.9
1414     - portnames:
1415         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1416         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1417     - 1GB ports (tbd)
1418 - ServerB23 [Server-Type-B5]:
1419     - testbedname: testbed35.
1420     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1421     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1422     - Host IP: 10.30.51.10
1423     - portnames:
1424         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1425         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1426     - 1GB ports (tbd)
1427 - ServerB24 [Server-Type-B5]:
1428     - testbedname: testbed35.
1429     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1430     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1431     - Host IP: 10.30.51.11
1432     - portnames:
1433         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1434         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1435     - 1GB ports (tbd)
1436 ```
1437
1438 #### 3-Node-Taishan Servers (3n-tsh) WIP
1439
1440 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1441
1442 ```
1443 - ServerB17 [Server-Type-B3]:
1444     - testbedname: testbed33.
1445     - hostname: s17-t33-sut1.
1446     - IPMI IP: 10.30.50.36
1447     - Host IP: 10.30.51.36
1448     - portnames:
1449         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1450         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1451         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1452         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1453 - ServerB18 [Server-Type-B3]:
1454     - testbedname: testbed33.
1455     - hostname: s18-t33-sut2.
1456     - IPMI IP: 10.30.50.37
1457     - Host IP: 10.30.51.37
1458     - portnames:
1459         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1460         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1461         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1462         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1463 - ServerB19 [Server-Type-B2]:
1464     - testbednames: testbed33 and testbed34.
1465     - hostname: s19-t33t34-tg1.
1466     - IPMI IP: 10.30.50.46
1467     - Host IP: 10.30.51.49
1468     - portnames:
1469         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1470         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1471         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1472         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1473         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1474         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1475         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1476         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1477         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1478         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1479 - ServerB20 [Server-Type-B4]:
1480     - testbedname: testbed34.
1481     - hostname: s20-t34-sut1.
1482     - IPMI IP: N/A
1483     - Host IP: 10.30.51.41
1484     - portnames:
1485         - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1486         - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1487 - ServerB21 [Server-Type-B4]:
1488     - testbedname: testbed34.
1489     - hostname: s21-t34-sut2.
1490     - IPMI IP: N/A
1491     - Host IP: 10.30.51.42
1492     - portnames:
1493         - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1494         - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1495 ```
1496
1497 #### 3-Node-Denverton Servers (3n-dnv) WIP
1498
1499 ```
1500 - ServerB30 [Server-Type-B10]:
1501     - testbednames: testbed35.
1502     - hostname: s30-t35-sut1.
1503     - IPMI IP: 10.30.55.12
1504     - Host IP: 10.32.8.12
1505     - portnames:
1506         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1507         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1508         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1509         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1510 - ServerB31 [Server-Type-B10]:
1511     - testbednames: testbed35.
1512     - hostname: s31-t35-sut2.
1513     - IPMI IP: 10.30.55.13
1514     - Host IP: 10.32.8.13
1515     - portnames:
1516         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1517         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1518         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1519         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1520 ```
1521
1522 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1523
1524 ```
1525 To be completed.
1526 ```
1527
1528 ### Per Testbed Wiring
1529
1530 #### 1-Node-Skylake Wiring (1n-skx) PROD
1531
1532 ```
1533 - testbed11:
1534     - ring1 10GE-ports x710-4p10GE:
1535         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1536     - ring2 10GE-ports x710-4p10GE:
1537         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1538     - ring3 10GE-ports x710-4p10GE:
1539         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1540     - ring4 10GE-ports x710-4p10GE:
1541         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1542 - testbed12:
1543     - ring1 10GE-ports x710-4p10GE:
1544         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1545     - ring2 10GE-ports x710-4p10GE:
1546         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1547     - ring3 10GE-ports x710-4p10GE:
1548         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1549     - ring4 10GE-ports x710-4p10GE:
1550         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1551 ```
1552
1553 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1554
1555 ```
1556 - testbed36:
1557     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1558         - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
1559     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1560         - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
1561     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1562         - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
1563     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1564         - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
1565
1566 - testbed37:
1567     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1568         - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
1569     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1570         - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
1571     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1572         - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
1573     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1574         - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
1575 ```
1576
1577 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1578
1579 ```
1580 - testbed14:
1581     - ring1 10GE-ports x710-4p10GE:
1582         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1583     - ring2 10GE-ports x710-4p10GE:
1584         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1585     - ring3 10GE-ports x710-4p10GE:
1586         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1587     - ring4 10GE-ports x710-4p10GE:
1588         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1589 ```
1590
1591 #### 2-Node-Skylake Wiring (2n-skx) PROD
1592
1593 ```
1594 - testbed21:
1595     - ring1 10GE-ports x710-4p10GE on SUT:
1596         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1597         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1598     - ring2 10GE-ports x710-4p10GE on SUT:
1599         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1600         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1601     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1602         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1603         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1604 - testbed22:
1605     - ring1 10GE-ports x710-4p10GE on SUT:
1606         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1607         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1608     - ring2 10GE-ports x710-4p10GE on SUT:
1609         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1610         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1611     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1612         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1613         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1614 - testbed23:
1615     - ring1 10GE-ports x710-4p10GE on SUT:
1616         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1617         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1618     - ring2 10GE-ports x710-4p10GE on SUT:
1619         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1620         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1621     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1622         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1623         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1624 - testbed24:
1625     - ring1 10GE-ports x710-4p10GE on SUT:
1626         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1627         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1628     - ring2 10GE-ports x710-4p10GE on SUT:
1629         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1630         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1631     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1632         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1633         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1634 ```
1635
1636 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1637
1638 ```
1639 - testbed26:
1640     - ring1 10GE-ports x553 copper port on SUT:
1641         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1642         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1643     - ring2 10GE-ports x553 fiber port on SUT:
1644         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1645         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1646 ```
1647
1648 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1649
1650 ```
1651 - testbed25:
1652     - link1 10GE-port x710-4p10GE on SUT:
1653         - t25-tg1-p1 to t25-sut1-c2/p1.
1654     - link2 10GE-port x710-4p10GE on SUT:
1655         - t25-tg1-p2 to t25-sut1-c2/p2.
1656     - link3 10GE-port x710-4p10GE on SUT:
1657         - t25-tg1-p3 to t25-sut1-c2/p3.
1658     - link4 10GE-port x710-4p10GE on SUT:
1659         - t25-tg1-p4 to t25-sut1-c2/p4.
1660 ```
1661
1662 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1663
1664 ```
1665 - testbed27:
1666     - ring1 10GE-ports x710-4p10GE on SUT:
1667         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1668         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1669     - ring2 10GE-ports x710-4p10GE on SUT:
1670         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1671         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1672     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1673         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1674         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1675     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1676         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1677         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1678 - testbed28:
1679     - ring1 10GE-ports x710-4p10GE on SUT:
1680         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1681         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1682     - ring2 10GE-ports x710-4p10GE on SUT:
1683         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1684         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1685     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1686         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1687         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1688     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1689         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1690         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1691 - testbed29:
1692     - ring1 10GE-ports x710-4p10GE on SUT:
1693         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1694         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1695     - ring2 10GE-ports x710-4p10GE on SUT:
1696         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1697         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1698     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1699         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1700         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1701     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1702         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1703         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1704 ```
1705
1706 #### 2-Node-Zen2 Wiring (2n-zen2) SETUP
1707
1708 ```
1709 - testbed210:
1710     - ring1 10GE-ports x710-4p10GE on SUT:
1711         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1712         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1713     - ring2 10GE-ports x710-4p10GE on SUT:
1714         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1715         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1716     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1717         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1718         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1719     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1720         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1721         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1722 ```
1723
1724 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1725
1726 ```
1727  1. testbed1:
1728     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1729         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1730         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1731         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1732     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1733         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1734         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1735         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1736     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1737         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1738         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1739         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1740     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1741         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1742         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1743         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1744     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1745         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1746         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1747         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1748     - TG loopback ports Intel NIC x710 2p10GE
1749         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1750
1751  2. testbed2:
1752     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1753         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1754         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1755         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1756     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1757         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1758         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1759         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1760     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1761         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1762         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1763         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1764     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1765         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1766         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1767         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1768     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1769         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1770         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1771         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1772     - TG loopback ports Intel NIC x710 2p10GE
1773         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1774
1775  3. testbed3:
1776     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1777         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1778         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1779         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1780     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1781         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1782         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1783         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1784     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1785         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1786         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1787         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1788     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1789         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1790         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1791         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1792     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1793         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1794         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1795         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1796     - TG loopback ports Intel NIC x710 2p10GE
1797         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1798 ```
1799
1800 #### 3-Node-Skylake Wiring (3n-skx) PROD
1801
1802 ```
1803 - testbed31:
1804     - ring1 10GE-ports x710-4p10GE on SUTs:
1805         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1806         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1807         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1808     - ring2 10GE-ports x710-4p10GE on SUT:
1809         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1810         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1811         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1812     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1813         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1814         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1815         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1816     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1817         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1818         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1819         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1820     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1821         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1822         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1823 - testbed32:
1824     - ring1 10GE-ports x710-4p10GE on SUTs:
1825         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1826         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1827         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1828     - ring2 10GE-ports x710-4p10GE on SUT:
1829         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1830         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1831         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1832     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1833         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1834         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1835         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1836     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1837         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1838         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1839         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1840     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1841         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1842         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1843 ```
1844
1845 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1846
1847 ```
1848 To be completed.
1849 ```
1850
1851 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1852
1853 ```
1854 - testbed33:
1855     - ring1 10GE-ports x520-2p10GE on SUTs:
1856         - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1857         - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1858         - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1859     - ring2 25GE-ports cx4-2p25GE on SUTs:
1860         - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1861         - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1862         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1863 ```
1864
1865 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1866
1867 ```
1868 - testbed34:
1869     - ring1 10GE-ports Marvell on SUTs:
1870         - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1871         - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1872         - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1873 ```
1874
1875 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1876
1877 ```
1878 - testbed35:
1879     - ring1 10GE-ports x553 copper port on SUTs:
1880         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1881         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1882         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1883     - ring2 10GE-ports x553 fiber port on SUTs:
1884         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1885         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1886         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1887 ```
1888
1889 ## Inventory
1890
1891 ### Appliances
1892
1893 ```
1894 1. Ixia PerfectStorm One Appliance
1895     - 1 * PS10GE4NG
1896         - Chassis: PS10GE4NG.
1897         - Motherboard: SuperMicro X11DPG-QT.
1898         - Processors: Quad-Core, Intel Processor.
1899         - HW accelerators: FPGA offload.
1900         - RAM Memory: 64GB.
1901         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1902         - Physical Interfaces: 4 * 10GE SFP+.
1903         - Operating System: Native IxOS.
1904 ```
1905
1906 ### Arm Servers
1907
1908 ```
1909 1. Arm Cortex A-72 servers
1910     - 2 * ThunderX2 (VPP Device)
1911         - Chassis: GIGABYTE Rack Mount
1912         - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2
1913         - RAM Memory: 250GB
1914         - Disks: 500GB
1915     - 1 * ThunderX2 (Idle)
1916         - Chassis: Marvell ThunderX2
1917         - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1918         - RAM Memory: 4* 32GB RDIMM
1919         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1920     - 2 * Huawei TaiShan 2280.
1921         - Chassis: Huawei TaiShan 2280.
1922         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1923         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1924         - Disks: 1* 4TB SATA HDD.
1925     - 3 * MACCHIATObin
1926         - Chassis: MACCHIATObin.
1927         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1928         - RAM Memory: 1* 16GB DDR4.
1929         - Disks: 1* 128GB(?) SATA SDD.
1930 ```
1931
1932 ### Xeon and Atom Servers
1933
1934 ```
1935 1. Intel Xeon servers:
1936     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1937         - Chassis: SuperMicro SYS-7049GP-TRT.
1938         - Motherboard: SuperMicro X11DPG-QT.
1939         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1940         - RAM Memory: 16* 16GB DDR4-2666MHz.
1941         - Disks: 2* 1.6TB 6G SATA SSD.
1942 2. Intel Atom servers with Rangely processors.
1943     - 3 * Netgate XG-2758-1u
1944         - Chassis: Netgate XG-2758-1u
1945         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1946         - RAM Memory: 16GB ECC
1947         - Disks: 150 GB
1948 ```
1949
1950 ### Network Interface Cards
1951
1952 ```
1953 1. 10GE NICs
1954     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1955     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1956     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1957 2. 25GE NICs
1958     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1959 3. 40GE NICs
1960     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1961 4. 100GE NICs
1962     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1963 ```
1964
1965 ### Pluggables and Cables
1966
1967 Pluggables:
1968
1969 ```
1970 1. 10GE SFP+
1971     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1972     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1973 2. 25GE SFP28
1974     - None
1975 3. 40GE QSFP+
1976     - None
1977 4. 100GE
1978     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1979 ```
1980
1981 Standalone cables:
1982
1983 ```
1984 1. 10GE
1985     - None
1986 2. 25GE
1987     - None
1988 3. 40GE QSFP+
1989     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1990 4. 100GE
1991     - None
1992 ```
1993
1994 ### Other Parts