1 # FD.io CSIT Testbed Specifications
4 1. [Testbeds Overview](#testbeds-overview)
5 1. [Summary List](#summary-list)
6 1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7 1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8 1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9 1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10 1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11 1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12 1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13 1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14 1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
15 1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16 1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17 1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
18 1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
19 1. [Server Management](#server-management)
20 1. [Requirements](#requirements)
21 1. [Addressing](#addressing)
22 1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23 1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25 1. [Server Types](#server-types)
26 1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28 1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29 1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30 1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
31 1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32 1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
33 1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
34 1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
35 1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
36 1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup])
37 1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
38 1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
39 1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
40 1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
41 1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
42 1. [Per Testbed Wiring](#per-testbed-wiring)
43 1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44 1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
45 1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
46 1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
47 1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
48 1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
49 1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
50 1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup])
51 1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
52 1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
53 1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
54 1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
55 1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
56 1. [Inventory](#inventory)
57 1. [Appliances](#appliances)
58 1. [Arm Servers](#arm-servers)
59 1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60 1. [Network Interface Cards](#network-interface-cards)
61 1. [Pluggables and Cables](#pluggables-and-cables)
62 1. [Other Parts](#other-parts)
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
74 #. CSIT_tb Purpose SUT TG #TB #SUT #TG #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb #clx #zn2
75 1. 1-Node-VIRL dev hsw --- 3 3 0 3 0 0 0 0 0 0 0 0 0
76 2. 1-Node-Skylake dev skx na 2 2 0 0 2 0 0 0 0 0 0 0 0
77 3. 1-Node-Thunderx2 idle tx2 na 1 1 0 0 0 0 0 0 1 0 0 0 0
78 4. 1-Node-Thunderx2 dev tx2 na 2 2 0 0 0 0 0 0 2 0 0 0 0
79 5. 1-Node-Cascadelake dev clx lcx 1 1 0 0 0 0 0 0 0 0 0 1 0
80 6. 2-Node-Skylake perf skx skx 4 4 4 0 8 0 0 0 0 0 0 0 0
81 7. 2-Node-Denverton perf dnv skx 1 1 1 0 .5 0 0 1 0 0 0 0 0
82 8. 2-Node-IxiaPS1L47 tcp skx ps1 1 1 1 0 1 1 0 0 0 0 0 0 0
83 9. 2-Node-Cascadelake perf clx clx 3 3 3 0 0 0 0 0 0 0 0 6 0
84 10. 3-Node-Haswell perf hsw hsw 3 6 3 9 0 0 0 0 0 0 0 0 0
85 11. 3-Node-Skylake perf skx skx 2 4 2 0 6 0 0 0 0 0 0 0 0
86 12. 3-Node-Rangeley perf rng skx 1 3 1 0 0 0 2 0 0 0 0 0 0
87 13. 3-Node-Taishan perf tsh skx 1 2 1 0 .5 0 0 0 0 2 0 0 0
88 14. 3-Node-Mcbin perf mcb skx 1 2 1 0 .5 0 0 0 0 0 2 0 0
89 15. 3-Node-Denverton perf dnv skx 1 2 1 0 .5 0 0 2 0 0 0 0 0
90 16. 2-Node-Zen2 perf zn2 zn2 1 1 1 0 0 0 0 0 0 0 0 0 2
91 Totals: 28 38 18 12 19 1 2 3 3 2 2 7 2
94 ### 1-Node-Skylake Xeon Intel (1n-skx)
96 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
97 ports connected back-to-back ([Server Types](#server-types)).
98 Used for FD.io VPP_Device functional driver tests.
100 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
102 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
103 ports connected back-to-back ([Server Types](#server-types)).
104 Used for FD.io VPP_Device functional driver tests.
106 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
108 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
109 NIC ports connected back-to-back ([Server Types](#server-types)).
111 Used for FD.io VPP_Device functional driver tests.
113 ### 2-Node-Skylake Xeon Intel (2n-skx)
115 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
116 (Server-Type-B2) connected in a 2-node circular topology
117 ([Server Types](#server-types)).
118 Used for FD.io performance tests.
120 ### 2-Node-Denverton Atom Intel (2n-dnv)
122 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
123 TG (Server-Type-B2) connected in a 2-node circular topology
124 ([Server Types](#server-types)).
125 Used for FD.io performance tests.
127 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
129 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
130 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
131 circular topology ([Server Types](#server-types)).
132 Used for FD.io TCP/IP and HTTP performance tests.
134 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
136 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
137 one TG (Server-Type-C3) connected in a 2-node circular topology
138 ([Server Types](#server-types)).
139 Used for FD.io performance tests.
141 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
143 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
144 one TG (Server-Type-D2) connected in a 2-node circular topology
145 ([Server Types](#server-types)).
146 Used for FD.io performance tests.
148 ### 3-Node-Haswell Xeon Intel (3n-hsw)
150 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
151 TG (Server-Type-A2) connected in a 3-node circular topology
152 ([Server Types](#server-types)).
153 Used for FD.io performance tests.
155 ### 3-Node-Skylake Xeon Intel (3n-skx)
157 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
158 TG (Server-Type-B2) connected in a 3-node circular topology.
159 Used for FD.io performance tests.
161 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
163 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
164 TG (Server-Type-B2) connected in a 3-node circular topology
165 ([Server Types](#server-types)).
166 Used for FD.io performance tests.
168 ### 3-Node-MACCHIATObin Arm Marvell
170 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
171 one TG (Server-Type-B2) connected in a 3-node circular topology
172 ([Server Types](#server-types)).
173 Used for FD.io performance tests.
175 ### 3-Node-Rangeley Atom Testbeds
177 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
178 TG (Server-Type-2) connected in a 3-node circular topology
179 ([Server Types](#server-types)).
180 Used for FD.io performance tests.
186 For management purposes, each server must have following two ports
187 connected to the management network:
191 - IPMI - Intelligent Platform Management Interface.
192 - Required for access to embedded server management with WebUI, CLI,
193 SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
194 - 1GE/10GE/40GE management port
195 - hostOS management port for general system management.
200 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
201 Management port, which are connected to two different VLANs.
205 - Subnet: 10.30.50.0/24
206 - Gateway: 10.30.50.1
207 - Broadcast: 10.30.50.255
208 - DNS1: 199.204.44.24
209 - DNS2: 199.204.47.54
211 - Subnet: 10.30.51.0/24
212 - Gateway: 10.30.51.1
213 - Broadcast: 10.30.51.255
214 - DNS1: 199.204.44.24
215 - DNS2: 199.204.47.54
218 To access these hosts, VPN connection is required.
220 ### LOM (IPMI) VLAN IP Addresses
223 ------------ | -------
226 10.30.50.2 | LF Reserved
227 10.30.50.3 | LF Reserved
228 10.30.50.4 | LF Reserved
229 10.30.50.5 | LF Reserved
230 10.30.50.6 | LF Reserved
231 10.30.50.7 | LF Reserved
232 10.30.50.8 | LF Reserved
233 10.30.50.9 | LF Reserved
234 10.30.50.10 | LF Reserved
235 10.30.50.11 | LF Reserved
236 10.30.50.12 | LF Reserved
237 10.30.50.13 | LF Reserved
238 10.30.50.14 | LF Reserved
239 10.30.50.15 | LF Reserved
241 10.30.50.17 | t1-sut1
242 10.30.50.18 | t1-sut2
244 10.30.50.21 | t2-sut1
245 10.30.50.22 | t2-sut2
247 10.30.50.25 | t3-sut1
248 10.30.50.26 | t3-sut-2
249 10.30.50.28 | s41-nomad
250 10.30.50.29 | s39-nomad
251 10.30.51.29 | s22-t35-sut1 screen -r /dev/ttyusb0
252 10.30.50.30 | s40-nomad
253 10.30.51.30 | s23-t35-sut2 screen -r /dev/ttyusb1
254 10.30.51.30 | s24-t35-sut3 screen -r /dev/ttyusb2
255 10.30.50.32 | s42-nomad (formerly nomad1)
256 10.30.50.33 | s43-nomad (formerly nomad2)
257 10.30.50.34 | s44-nomad (formerly nomad3)
258 10.30.50.35 | s45-nomad (formerly nomad4)
259 10.30.50.36 | s17-t33-sut1
260 10.30.50.37 | s18-t33-sut2
261 10.30.50.38 | fdio-marvell-dev
262 10.30.50.39 | s53-nomad
263 10.30.50.40 | s54-nomad
264 10.30.50.41 | s3-t21-sut1
265 10.30.50.42 | s4-t21-tg1
266 10.30.50.43 | s11-t31-sut1
267 10.30.50.44 | s12-t31-sut2
268 10.30.50.45 | s13-t31-tg1
269 10.30.50.46 | s19-t33t34-tg1
270 10.30.50.47 | s1-t11-sut1
271 10.30.50.48 | s2-t12-sut1
272 10.30.50.49 | s5-t22-sut1
273 10.30.50.50 | s6-t22-tg1
274 10.30.50.51 | s7-t23-sut1
275 10.30.50.52 | s8-t23-tg1
276 10.30.50.53 | s9-t24-sut1
277 10.30.50.54 | s10-t24-tg1
278 10.30.50.55 | s14-t32-sut1
279 10.30.50.56 | s15-t32-sut2
280 10.30.50.57 | s16-t32-tg1
281 10.30.50.58 | s25-t25-sut1
282 10.30.50.59 | s26-t25-tg1
283 10.30.50.65 | s52-nomad
284 10.30.50.66 | s51-nomad (out of order)
285 10.30.50.67 | s49-nomad
286 10.30.50.68 | s50-nomad (out of order)
287 10.30.50.69 | s27-t13-sut
288 10.30.50.70 | s55-t36-sut1
289 10.30.50.71 | s56-t37-sut1
290 10.30.50.255 | Broadcast
295 10.30.55.10 | s28-t26t35-tg1
296 10.30.55.11 | s29-t26-sut1
297 10.30.55.12 | s30-t35-sut1
298 10.30.55.13 | s31-t35-sut2
299 10.30.55.14 | s46-nomad (formerly server-type-c4-1)
300 10.30.55.15 | s47-nomad (formerly server-type-c4-2)
301 10.30.55.16 | s48-nomad (formerly server-type-c4-3)
302 10.30.55.17 | s32-t14-sut1
303 10.30.55.18 | s33-t27-sut1
304 10.30.55.19 | s34-t27-tg1
305 10.30.55.20 | s35-t28-sut1
306 10.30.55.21 | s36-t28-tg1
307 10.30.55.22 | s37-t29-sut1
308 10.30.55.23 | s38-t29-tg1
309 10.30.55.24 | s60-t210-sut1
310 10.30.55.25 | s61-t210-tg1
311 10.30.55.255 | Broadcast
313 ### Management VLAN IP Addresses
316 ------------------------- | -------
319 10.30.51.2 | LF Reserved
320 10.30.51.3 | LF Reserved
321 10.30.51.4 | LF Reserved
322 10.30.51.5 | LF Reserved
323 10.30.51.6 | LF Reserved
324 10.30.51.7 | LF Reserved
325 10.30.51.8 | LF Reserved
326 10.30.51.9 | s22-t35-sut1 (netgate-1)
327 10.30.51.10 | s23-t35-sut2 (netgate-2)
328 10.30.51.11 | s24-t35-sut3 (netgate-3)
329 10.30.51.12 | softiron-1
330 10.30.51.13 | softiron-2
331 10.30.51.14 | softiron-3
332 10.30.51.15 | LF Reserved
334 10.30.51.17 | t1-sut1
335 10.30.51.18 | t1-sut2
337 10.30.51.21 | t2-sut1
338 10.30.51.22 | t2-sut2
340 10.30.51.25 | t3-sut1
341 10.30.51.26 | t3-sut-2
342 10.30.51.28 | s41-nomad
343 10.30.51.29 | s39-nomad
344 10.30.51.30 | s40-nomad
345 10.30.51.32 | s42-nomad (formerly nomad1)
346 10.30.51.33 | s43-nomad (formerly nomad2)
347 10.30.51.34 | s44-nomad (formerly nomad3)
348 10.30.51.35 | s45-nomad (formerly nomad4)
349 10.30.51.36 | s17-t33-sut1
350 10.30.51.37 | s18-t33-sut2
351 10.30.51.38 | fdio-marvell-dev
352 10.30.51.39 | s53-nomad
353 10.30.51.40 | s54-nomad
354 10.30.51.41 | s20-t34-sut1
355 10.30.51.42 | s21-t34-sut2
356 10.30.51.44 | s3-t21-sut1
357 10.30.51.45 | s4-t21-tg1
358 10.30.51.46 | s11-t31-sut1
359 10.30.51.47 | s12-t31-sut2
360 10.30.51.48 | s13-t31-tg1
361 10.30.51.49 | s19-t33t34-tg1
362 10.30.51.50 | s1-t11-sut1
363 10.30.51.51 | s2-t12-sut1
364 10.30.51.52 | s5-t22-sut1
365 10.30.51.53 | s6-t22-tg1
366 10.30.51.54 | s7-t23-sut1
367 10.30.51.55 | s8-t23-tg1
368 10.30.51.56 | s9-t24-sut1
369 10.30.51.57 | s10-t24-tg1
370 10.30.51.58 | s14-t32-sut1
371 10.30.51.59 | s15-t32-sut2
372 10.30.51.60 | s16-t32-tg1
373 10.30.51.61 | s25-t25-sut1
374 10.30.51.62 | s26-t25-tg1
375 10.30.51.65 | s52-nomad
376 10.30.51.66 | s51-nomad
377 10.30.51.67 | s49-nomad
378 10.30.51.68 | s50-nomad
379 10.30.51.69 | s27-t13-sut1
380 10.30.51.70 | s55-t36-sut1
381 10.30.51.71 | s56-t37-sut1
382 10.30.51.72-10.30.51.105 | FREE
383 10.30.51.106-10.30.51.180 | FREE
384 10.30.51.181-10.30.51.254 | FREE
385 10.30.51.255 | Broadcast
388 10.32.8.10 | s28-t26t35-tg1
389 10.32.8.11 | s29-t26-sut1
390 10.32.8.12 | s30-t35-sut1
391 10.32.8.13 | s31-t35-sut2
392 10.32.8.14 | s46-nomad (formerly server-type-c4-1)
393 10.32.8.15 | s47-nomad (formerly server-type-c4-2)
394 10.32.8.16 | s48-nomad (formerly server-type-c4-3)
395 10.32.8.17 | s32-t14-sut1
396 10.32.8.18 | s33-t27-sut1
397 10.32.8.19 | s34-t27-tg1
398 10.32.8.20 | s35-t28-sut1
399 10.32.8.21 | s36-t28-tg1
400 10.32.8.22 | s37-t29-sut1
401 10.32.8.23 | s38-t29-tg1
402 10.32.8.24 | s60-t210-sut1
403 10.32.8.25 | s61-t210-tg1
404 10.32.8.255 | Broadcast
406 ## Server Specifications
410 FD.io CSIT lab contains following server types:
412 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
413 - Quantity: 6 servers.
414 - Physical connectivity:
415 - CIMC and host management ports.
416 - NIC ports connected in 3-node topologies.
417 - Main HW configuration:
418 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
419 - Processors: 2* E5-2699v3 2.3 GHz.
420 - RAM Memory: 16* 32GB DDR4-2133MHz.
421 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
422 - NICs configuration:
423 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
424 - PCIe Slot1: Cisco VIC 1385 2p40GE.
425 - PCIe Slot2: Intel NIC x520 2p10GE.
427 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
428 - PCIe Slot4: Intel NIC xl710 2p40GE.
429 - PCIe Slot5: Intel NIC x710 2p10GE.
430 - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
431 - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
432 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
433 - Quantity: 3 servers.
434 - Physical connectivity:
435 - CIMC and host management ports.
436 - NIC ports connected in 3-node topologies.
437 - Main HW configuration:
438 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
439 - Processors: 2* E5-2699v3 2.3 GHz.
440 - RAM Memory: 16* 32GB DDR4-2133MHz.
441 - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
442 - NICs configuration:
443 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
444 - PCIe Slot1: Intel NIC xl710 2p40GE.
445 - PCIe Slot2: Intel NIC x710 2p10GE.
446 - PCIe Slot3: Intel NIC x710 2p10GE.
447 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
448 - PCIe Slot4: Intel NIC xl710 2p40GE.
449 - PCIe Slot5: Intel NIC x710 2p10GE.
450 - PCIe Slot6: Intel NIC x710 2p10GE.
452 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
453 - Quantity: 3 servers.
454 - Physical connectivity:
455 - CIMC and host management ports.
456 - no NIC ports, standalone setup.
457 - Main HW configuration:
458 - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
459 - Processors: 2* E5-2699v3 2.3 GHz.
460 - RAM Memory: 16* 32GB DDR4-2133MHz.
461 - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
462 - NICs configuration:
463 - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
465 - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
468 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
470 - Physical connectivity:
471 - IPMI and host management ports.
472 - NIC ports connected into 2-node and 3-node topologies.
473 - Main HW configuration:
474 - Chassis: SuperMicro SYS-7049GP-TRT.
475 - Motherboard: SuperMicro X11DPG-QT.
476 - Processors: 2* Intel Platinum 8180 2.5 GHz.
477 - RAM Memory: 16* 16GB DDR4-2666MHz.
478 - Disks: 2* 1.6TB 6G SATA SSD.
479 - NICs configuration:
480 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
481 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
482 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
483 - PCIe Slot9 5e:00.xx: empty.
484 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
485 - PCIe Slot6 86:00.xx: empty.
486 - PCIe Slot8 af:00.xx: empty.
487 - PCIe Slot10 d8:00.xx: empty.
488 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
490 - Physical connectivity:
491 - IPMI and host management ports.
492 - NIC ports connected into 2-node and 3-node topologies.
493 - Main HW configuration:
494 - Chassis: SuperMicro SYS-7049GP-TRT.
495 - Motherboard: SuperMicro X11DPG-QT.
496 - Processors: 2* Intel Platinum 8180 2.5 GHz.
497 - RAM Memory: 16* 16GB DDR4-2666MHz.
498 - Disks: 2* 1.6TB 6G SATA SSD.
499 - NICs configuration:
500 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
501 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
502 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
503 - PCIe Slot9 5e:00.xx: empty.
504 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
505 - PCIe Slot6 86:00.xx: empty.
506 - PCIe Slot8 af:00.xx: empty.
507 - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
508 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
510 - Physical connectivity:
511 - IPMI(?) and host management ports.
512 - NIC ports connected into 3-node topology.
513 - Main HW configuration:
514 - Chassis: Huawei TaiShan 2280.
515 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
516 - RAM Memory: 8* 16GB DDR4-2400MT/s
517 - Disks: 1* 4TB SATA HDD
518 - NICs configuration:
519 - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
520 - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
521 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
523 - Physical connectivity:
524 - Host management ports.
525 - NIC ports connected into 2-node and 3-node topologies.
526 - Main HW configuration:
527 - Chassis: MACCHIATObin.
528 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
529 - RAM Memory: 1* 16GB DDR4
530 - Disks: 1* 128GB(?) SATA SDD
531 - NICs configuration:
532 - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
533 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
534 - Quantity: TBD based on testbed allocation.
535 - Physical connectivity:
536 - Management: serial Port (usb) for console
537 - NIC ports connected into 2-node.
538 - Main HW configuration:
539 - Chassis: Netgate XG-2758-1u
540 - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
541 - RAM Memory: 16GB ECC
543 - NICs configuration:
544 - 2x 10Gb Intel 82599ES
546 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
548 - Physical connectivity:
549 - IPMI and host management ports.
550 - NIC ports connected into 1-node topologies.
551 - Main HW configuration:
552 - Chassis: SuperMicro SYS-7049GP-TRT.
553 - Motherboard: SuperMicro X11DPG-QT.
554 - Processors: 2* Intel Platinum 8180 2.5 GHz.
555 - RAM Memory: 16* 16GB DDR4-2666MHz.
556 - Disks: 2* 1.6TB 6G SATA SSD.
557 - NICs configuration:
558 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
559 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
560 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
561 - PCIe Slot9 5e:00.xx: empty.
562 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
563 - PCIe Slot6 86:00.xx: empty.
564 - PCIe Slot8 af:00.xx: empty.
565 - PCIe Slot10 d8:00.xx: empty.
566 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
568 - Physical connectivity:
569 - Host management interface: 10/100/1000-BaseT.
570 - 8-port 10GE SFP+ integrated NIC.
571 - Main HW configuration:
572 - Chassis: PS10GE4NG.
573 - Motherboard: SuperMicro X11DPG-QT.
574 - Processors: Quad-Core, Intel Processor.
575 - HW accelerators: FPGA offload.
577 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
578 - Physical Interfaces: 4 * 10GE SFP+.
579 - Operating System: Native IxOS.
580 - Interface configuration:
585 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
587 - Physical connectivity:
588 - IPMI and host management ports.
590 - Main HW configuration:
591 - Chassis: SuperMicro SYS-7049GP-TRT.
592 - Motherboard: SuperMicro X11DPG-QT.
593 - Processors: 2* Intel Platinum 8180 2.5 GHz.
594 - RAM Memory: 16* 16GB DDR4-2666MHz.
595 - Disks: 2* 1.6TB 6G SATA SSD.
596 - NICs configuration:
597 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
598 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
599 - PCIe Slot4 3b:00.xx: empty.
600 - PCIe Slot9 5e:00.xx: empty.
601 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
602 - PCIe Slot6 86:00.xx: empty.
603 - PCIe Slot8 af:00.xx: empty.
604 - PCIe Slot10 d8:00.xx: empty.
605 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell(Idle).
607 - Physical connectivity:
608 - IPMI and host management ports.
609 - NIC ports connected into 1-node topologies.
610 - Main HW configuration:
611 - Chassis: Gigabyte R181-T90 1U
612 - Motherboard: MT91-FS1
613 - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
614 - RAM Memory: 4* 32GB RDIMM
615 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
616 - NICs configuration:
618 - PCIe Slot1 05:00.xx: XL710-QDA2.
619 - PCIe Slot3 08:00.xx: XL710-QDA2.
621 - PCIe Slot6 85:00.xx: XL710-QDA2.
622 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
624 - Physical connectivity:
625 - IPMI and host management ports.
627 - Main HW configuration:
628 - Chassis: SuperMicro SYS-E300-9A
629 - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
630 - RAM Memory: 32GB ECC
632 - NICs configuration:
633 - 2x 10Gb Intel x553 fiber ports
634 - 2x 10Gb Intel x553 copper ports
635 - 4x 1GB Intel I350 ports
637 14. Server-Type-B11: Purpose - Thunderx2 Arm Marvell SUT for FD.io VPP_Device functional tests.
639 - Physical connectivity:
640 - IPMI and host management ports.
641 - NIC ports connected into 1-node topologies.
642 - Main HW configuration:
643 - Chassis: GIGABYTE Rack Mount
644 - Motherboard: MT91-FS4-00
645 - Processors: 2 * Thunderx2 ARMv8 CN9980 2.20 GHz
646 - RAM Memory: 16 * 16GB DIMM
647 - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
648 - NICs configuration:
650 - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
651 - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
653 - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
654 - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
656 15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
658 - Physical connectivity:
659 - IPMI and host management ports.
660 - NIC ports connected into 1-node testbed topologies.
661 - Main HW configuration:
662 - Chassis: SuperMicro SYS-7049GP-TRT.
663 - Motherboard: SuperMicro X11DPG-QT.
664 - Processors: 2* Intel Platinum 8280 2.7 GHz.
665 - RAM Memory: 12* 16GB DDR4-2933.
666 - Disks: 2* 1.92TB SATA SSD.
667 - NICs configuration:
668 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
669 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
670 - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
671 - PCIe Slot9 5e:00.xx: empty.
672 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
673 - PCIe Slot6 86:00.xx: empty.
674 - PCIe Slot8 af:00.xx: empty.
675 - PCIe Slot10 d8:00.xx: empty.
677 16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
679 - Physical connectivity:
680 - IPMI and host management ports.
681 - NIC ports connected into 2-node testbed topologies.
682 - Main HW configuration:
683 - Chassis: SuperMicro SYS-7049GP-TRT.
684 - Motherboard: SuperMicro X11DPG-QT.
685 - Processors: 2* Intel Gold 6252N 2.3 GHz.
686 - RAM Memory: 12* 16GB DDR4-2933.
687 - Disks: 2* 1.92TB SATA SSD.
688 - NICs configuration:
689 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
690 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
691 - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
692 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
693 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
694 - PCIe Slot6 86:00.xx: empty.
695 - PCIe Slot8 af:00.xx: empty.
696 - PCIe Slot10 d8:00.xx: empty.
697 17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
699 - Physical connectivity:
700 - IPMI and host management ports.
701 - NIC ports connected into 2-node testbed topologies.
702 - Main HW configuration:
703 - Chassis: SuperMicro SYS-7049GP-TRT.
704 - Motherboard: SuperMicro X11DPG-QT.
705 - Processors: 2* Intel Platinum 8280 2.7 GHz.
706 - RAM Memory: 12* 16GB DDR4-2933.
707 - Disks: 2* 1.92TB SATA SSD.
708 - NICs configuration:
709 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
710 - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
711 - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
712 - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
713 - Numa1: (x16, x16, x16 PCIe3.0 lanes)
714 - PCIe Slot6 86:00.xx: empty.
715 - PCIe Slot8 af:00.xx: empty.
716 - PCIe Slot10 d8:00.xx: empty.
718 18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
720 - Physical connectivity:
721 - CIMC and host management ports.
722 - no NIC ports, standalone setup.
723 - Main HW configuration:
724 - Chassis: SuperMicro 1029P-WTRT.
725 - Motherboard: SuperMicro X11DDW-NT.
726 - Processors: 2* Intel Platinum 8280 2.7 GHz.
727 - RAM Memory: 12* 16GB DDR4-2933.
728 - Disks: 4* 1.92TB SATA SSD.
729 - NICs configuration:
734 19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
736 - Physical connectivity:
737 - IPMI and host management ports.
738 - NIC ports connected into 2-node testbed topologies.
739 - Main HW configuration:
740 - Chassis: SuperMicro AS-1114S-WTRT
741 - Processors: 1* AMD EPYC 7532 2.4 GHz.
742 - RAM Memory: 8* 32GB DDR4-2933.
743 - Disks: 1* 1TB SATA SSD.
744 - NICs configuration:
745 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
746 - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
747 - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
748 - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
749 20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
751 - Physical connectivity:
752 - IPMI and host management ports.
753 - NIC ports connected into 2-node testbed topologies.
754 - Main HW configuration:
755 - Chassis: SuperMicro AS-1114S-WTRT
756 - Processors: 1* AMD EPYC 7532 2.4 GHz.
757 - RAM Memory: 8* 32GB DDR4-2933.
758 - Disks: 1* 1TB SATA SSD.
759 - NICs configuration:
760 - Numa0: (x16, x16, x16 PCIe3.0 lanes)
761 - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
762 - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
763 - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
766 ### Naming Convention
768 Following naming convention is used within this page to specify physical
769 connectivity and wiring across defined CSIT testbeds:
772 - testbedname: testbedN.
774 - traffic-generator: tN-tgW.
775 - system-under-testX: tN-sutX.
780 - N - testbed number.
781 - tgW - server acts as traffic-generator with W index.
782 - sutX - server acts as system-under-test with X index.
783 - Y - PCIe slot number denoting a NIC card number within the host.
784 - Z - port number on the NIC card.
787 ## Testbeds Configuration
789 ### Per Testbed Server Allocation and Naming
791 #### 1-Node-Skylake Servers (1n-skx) PROD
794 - SUT [Server-Type-B6]:
795 - testbedname: testbed11.
796 - hostname: s1-t11-sut1.
797 - IPMI IP: 10.30.50.47
798 - Host IP: 10.30.51.50
800 - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
801 - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
802 - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
803 - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
804 - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
805 - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
806 - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
807 - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
808 - SUT [Server-Type-B6]:
809 - testbedname: testbed12.
810 - hostname: s2-t12-sut1.
811 - IPMI IP: 10.30.50.48
812 - Host IP: 10.30.51.51
814 - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
815 - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
816 - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
817 - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
818 - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
819 - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
820 - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
821 - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
824 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
827 - SUT [Server-Type-B11]:
828 - testbedname: testbed36
829 - hostname: s55-t36-sut1
830 - IPMI IP: 10.30.50.70
831 - Host IP: 10.30.51.70
833 - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
834 - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
835 - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
836 - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
837 - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
838 - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
839 - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
840 - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
842 - SUT [Server-Type-B11]:
843 - testbedname: testbed37
844 - hostname: s56-t37-sut1
845 - IPMI IP: 10.30.50.71
846 - Host IP: 10.30.51.71
848 - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
849 - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
850 - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
851 - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
852 - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
853 - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
854 - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
855 - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
858 #### 1-Node-Cascadelake Servers (1n-clx) PROD
861 - SUT [Server-Type-C1]:
862 - testbedname: testbed11.
863 - hostname: s32-t14-sut1.
864 - IPMI IP: 10.30.55.17
865 - Host IP: 10.32.8.17
867 - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
868 - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
869 - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
870 - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
871 - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
872 - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
873 - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
874 - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
877 #### 2-Node-Skylake Servers (2n-skx) PROD
880 - SUT [Server-Type-B1]:
881 - testbedname: testbed21.
882 - hostname: s3-t21-sut1.
883 - IPMI IP: 10.30.50.41
884 - Host IP: 10.30.51.44
886 - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
887 - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
888 - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
889 - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
890 - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
891 - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
892 - TG [Server-Type-B2]:
893 - testbedname: testbed21.
894 - hostname: s4-t21-tg1.
895 - IPMI IP: 10.30.50.42
896 - Host IP: 10.30.51.45
898 - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
899 - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
900 - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
901 - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
902 - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
903 - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
904 - SUT [Server-Type-B1]:
905 - testbedname: testbed22.
906 - hostname: s5-t22-sut1.
907 - IPMI IP: 10.30.50.49
908 - Host IP: 10.30.51.52
910 - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
911 - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
912 - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
913 - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
914 - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
915 - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
916 - TG [Server-Type-B2]:
917 - testbedname: testbed22.
918 - hostname: s6-t22-tg1.
919 - IPMI IP: 10.30.50.50
920 - Host IP: 10.30.51.53
922 - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
923 - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
924 - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
925 - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
926 - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
927 - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
928 - SUT [Server-Type-B1]:
929 - testbedname: testbed23.
930 - hostname: s7-t23-sut1.
931 - IPMI IP: 10.30.50.51
932 - Host IP: 10.30.51.54
934 - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
935 - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
936 - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
937 - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
938 - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
939 - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
940 - TG [Server-Type-B2]:
941 - testbedname: testbed23.
942 - hostname: s8-t23-tg1.
943 - IPMI IP: 10.30.50.52
944 - Host IP: 10.30.51.55
946 - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
947 - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
948 - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
949 - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
950 - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
951 - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
952 - SUT [Server-Type-B1]:
953 - testbedname: testbed24.
954 - hostname: s9-t24-sut1.
955 - IPMI IP: 10.30.50.53
956 - Host IP: 10.30.51.56
958 - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
959 - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
960 - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
961 - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
962 - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
963 - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
964 - TG [Server-Type-B2]:
965 - testbedname: testbed24.
966 - hostname: s10-t24-tg1.
967 - IPMI IP: 10.30.50.54
968 - Host IP: 10.30.51.57
970 - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
971 - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
972 - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
973 - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
974 - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
975 - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
978 #### 2-Node-Denverton Servers (2n-dnv) WIP
980 Note: ServerB28 (TG) is shared between testbed26 & testbed35
983 - TG [Server-Type-B2]:
984 - testbednames: testbed26 and testbed35.
985 - hostname: s28-t26t35-tg1.
986 - IPMI IP: 10.30.55.10
987 - Host IP: 10.32.8.10
989 - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
990 - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
991 - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
992 - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
993 - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
994 - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
995 - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
996 - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
997 - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
998 - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
999 - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
1000 - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
1001 - SUT [Server-Type-B10]:
1002 - testbednames: testbed26.
1003 - hostname: s29-t26-sut1.
1004 - IPMI IP: 10.30.55.11
1005 - Host IP: 10.32.8.11
1007 - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
1008 - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
1009 - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
1010 - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
1013 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
1016 - SUT [Server-Type-B8]:
1017 - testbedname: testbed25.
1018 - hostname: s25-t25-sut1.
1019 - IPMI IP: 10.30.50.58
1020 - Host IP: 10.30.51.61
1022 - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1023 - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1024 - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1025 - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1026 - TG [Server-Type-B7]:
1027 - testbedname: testbed25.
1028 - hostname: s26-t25-tg1.
1029 - IPMI IP: 10.30.50.59
1030 - Host IP: 10.30.51.62
1032 - s26-t25-tg1-p1 - 10GE-port1.
1033 - s26-t25-tg1-p2 - 10GE-port2.
1034 - s26-t25-tg1-p3 - 10GE-port3.
1035 - s26-t25-tg1-p4 - 10GE-port4.
1038 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
1041 - SUT [Server-Type-C2]:
1042 - testbedname: testbed27.
1043 - hostname: s33-t27-sut1.
1044 - IPMI IP: 10.30.55.18
1045 - Host IP: 10.32.8.18
1047 - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1048 - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1049 - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1050 - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1051 - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1052 - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1053 - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1054 - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1055 - TG [Server-Type-C3]:
1056 - testbedname: testbed27.
1057 - hostname: s34-t27-tg1.
1058 - IPMI IP: 10.30.55.19
1059 - Host IP: 10.32.8.19
1061 - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1062 - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1063 - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1064 - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1065 - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1066 - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1067 - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1068 - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1069 - SUT [Server-Type-C2]:
1070 - testbedname: testbed28.
1071 - hostname: s35-t28-sut1.
1072 - IPMI IP: 10.30.55.20
1073 - Host IP: 10.32.8.20
1075 - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1076 - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1077 - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1078 - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1079 - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1080 - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1081 - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1082 - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1083 - TG [Server-Type-C3]:
1084 - testbedname: testbed28.
1085 - hostname: s36-t28-tg1.
1086 - IPMI IP: 10.30.55.21
1087 - Host IP: 10.32.8.21
1089 - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1090 - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1091 - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1092 - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1093 - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1094 - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1095 - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1096 - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1097 - SUT [Server-Type-C2]:
1098 - testbedname: testbed29.
1099 - hostname: s37-t29-sut1.
1100 - IPMI IP: 10.30.55.22
1101 - Host IP: 10.32.8.22
1103 - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1104 - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1105 - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1106 - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1107 - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1108 - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1109 - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1110 - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1111 - TG [Server-Type-C3]:
1112 - testbedname: testbed29.
1113 - hostname: s38-t29-tg1.
1114 - IPMI IP: 10.30.55.23
1115 - Host IP: 10.32.8.23
1117 - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1118 - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1119 - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1120 - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1121 - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1122 - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1123 - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1124 - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1127 #### 2-Node-Zen2 Servers (2n-zn2) SETUP
1130 - SUT [Server-Type-D1]:
1131 - testbedname: testbed210.
1132 - hostname: s60-t210-sut1.
1133 - IPMI IP: 10.30.55.24
1134 - Host IP: 10.32.8.24
1136 - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1137 - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1138 - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1139 - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1140 - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1141 - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1142 - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1143 - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1144 - TG [Server-Type-D2]:
1145 - testbedname: testbed210.
1146 - hostname: s61-t210-tg1.
1147 - IPMI IP: 10.30.55.25
1148 - Host IP: 10.32.8.25
1150 - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1151 - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1152 - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1153 - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1154 - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1155 - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1156 - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1157 - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1160 #### 3-Node-Haswell Servers (3n-hsw) PROD
1163 1. SUT [Server-Type-A1]:
1164 - testbedname: testbed1.
1165 - hostname: t1-sut1.
1166 - CIMC IP: 10.30.50.17
1167 - Host IP: 10.30.51.17
1169 - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1170 - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1171 - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1172 - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1173 - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1174 - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1175 - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1176 - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1177 - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1178 - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1179 2. SUT [Server-Type-A1]:
1180 - testbedname: testbed1.
1181 - hostname: t1-sut2.
1182 - CIMC IP: 10.30.50.18
1183 - Host IP: 10.30.51.18
1185 - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1186 - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1187 - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1188 - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1189 - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1190 - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1191 - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1192 - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1193 - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1194 - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1195 3. TG [Server-Type-A2]:
1196 - testbedname: testbed1.
1198 - CIMC IP: 10.30.50.16
1199 - Host IP: 10.30.51.16
1201 - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1202 - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1203 - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1204 - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1205 - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1206 - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1207 - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1208 - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1209 - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1210 - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1211 - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1212 - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1213 4. SUT [Server-Type-A1]:
1214 - testbedname: testbed2.
1215 - hostname: t2-sut1.
1216 - CIMC IP: 10.30.50.21
1217 - Host IP: 10.30.51.21
1219 - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1220 - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1221 - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1222 - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1223 - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1224 - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1225 - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1226 - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1227 - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1228 - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1229 5. SUT [Server-Type-A1]:
1230 - testbedname: testbed2.
1231 - hostname: t2-sut2.
1232 - CIMC IP: 10.30.50.22
1233 - Host IP: 10.30.51.22
1235 - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1236 - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1237 - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1238 - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1239 - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1240 - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1241 - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1242 - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1243 - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1244 - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1245 6. TG [Server-Type-A2]:
1246 - testbedname: testbed2.
1248 - CIMC IP: 10.30.50.20
1249 - Host IP: 10.30.51.20
1251 - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1252 - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1253 - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1254 - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1255 - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1256 - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1257 - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1258 - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1259 - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1260 - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1261 - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1262 - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1263 7. SUT [Server-Type-A1]:
1264 - testbedname: testbed3.
1265 - hostname: t3-sut1.
1266 - CIMC IP: 10.30.50.25
1267 - Host IP: 10.30.51.25
1269 - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1270 - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1271 - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1272 - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1273 - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1274 - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1275 - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1276 - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1277 - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1278 - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1279 8. SUT [Server-Type-A1]:
1280 - testbedname: testbed3.
1281 - hostname: t3-sut2.
1282 - CIMC IP: 10.30.50.26
1283 - Host IP: 10.30.51.26
1285 - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1286 - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1287 - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1288 - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1289 - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1290 - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1291 - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1292 - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1293 - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1294 - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1295 9. TG [Server-Type-A2]:
1296 - testbedname: testbed3.
1298 - CIMC IP: 10.30.50.24
1299 - Host IP: 10.30.51.24
1301 - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1302 - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1303 - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1304 - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1305 - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1306 - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1307 - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1308 - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1309 - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1310 - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1311 - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1312 - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1315 #### 3-Node-Skylake Servers (3n-skx) PROD
1318 - ServerB11 [Server-Type-B1]:
1319 - testbedname: testbed31.
1320 - hostname: s11-t31-sut1.
1321 - IPMI IP: 10.30.50.43
1322 - Host IP: 10.30.51.46
1324 - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1325 - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1326 - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1327 - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1328 - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1329 - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1330 - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1331 - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1332 - ServerB12 [Server-Type-B1]:
1333 - testbedname: testbed31.
1334 - hostname: s12-t31-sut2.
1335 - IPMI IP: 10.30.50.44
1336 - Host IP: 10.30.51.47
1338 - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1339 - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1340 - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1341 - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1342 - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1343 - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1344 - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1345 - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1346 - ServerB13 [Server-Type-B2]:
1347 - testbedname: testbed31.
1348 - hostname: s13-t31-tg1.
1349 - IPMI IP: 10.30.50.45
1350 - Host IP: 10.30.51.48
1352 - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1353 - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1354 - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1355 - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1356 - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1357 - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1358 - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1359 - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1360 - ServerB14 [Server-Type-B1]:
1361 - testbedname: testbed32.
1362 - hostname: s14-t32-sut1.
1363 - IPMI IP: 10.30.50.55
1364 - Host IP: 10.30.51.58
1366 - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1367 - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1368 - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1369 - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1370 - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1371 - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1372 - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1373 - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1374 - ServerB15 [Server-Type-B1]:
1375 - testbedname: testbed32.
1376 - hostname: s15-t32-sut2.
1377 - IPMI IP: 10.30.50.56
1378 - Host IP: 10.30.51.59
1380 - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1381 - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1382 - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1383 - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1384 - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1385 - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1386 - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1387 - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1388 - ServerB16 [Server-Type-B2]:
1389 - testbedname: testbed32.
1390 - hostname: s16-t32-tg1.
1391 - IPMI IP: 10.30.50.57
1392 - Host IP: 10.30.51.60
1394 - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1395 - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1396 - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1397 - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1398 - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1399 - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1400 - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1401 - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1404 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1406 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1409 - ServerB22 [Server-Type-B5]:
1410 - testbedname: testbed35.
1411 - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1412 - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1413 - Host IP: 10.30.51.9
1415 - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1416 - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1418 - ServerB23 [Server-Type-B5]:
1419 - testbedname: testbed35.
1420 - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1421 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1422 - Host IP: 10.30.51.10
1424 - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1425 - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1427 - ServerB24 [Server-Type-B5]:
1428 - testbedname: testbed35.
1429 - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1430 - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1431 - Host IP: 10.30.51.11
1433 - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1434 - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1438 #### 3-Node-Taishan Servers (3n-tsh) WIP
1440 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1443 - ServerB17 [Server-Type-B3]:
1444 - testbedname: testbed33.
1445 - hostname: s17-t33-sut1.
1446 - IPMI IP: 10.30.50.36
1447 - Host IP: 10.30.51.36
1449 - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1450 - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1451 - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1452 - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1453 - ServerB18 [Server-Type-B3]:
1454 - testbedname: testbed33.
1455 - hostname: s18-t33-sut2.
1456 - IPMI IP: 10.30.50.37
1457 - Host IP: 10.30.51.37
1459 - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1460 - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1461 - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1462 - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1463 - ServerB19 [Server-Type-B2]:
1464 - testbednames: testbed33 and testbed34.
1465 - hostname: s19-t33t34-tg1.
1466 - IPMI IP: 10.30.50.46
1467 - Host IP: 10.30.51.49
1469 - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1470 - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1471 - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1472 - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1473 - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1474 - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1475 - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1476 - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1477 - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1478 - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1479 - ServerB20 [Server-Type-B4]:
1480 - testbedname: testbed34.
1481 - hostname: s20-t34-sut1.
1483 - Host IP: 10.30.51.41
1485 - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1486 - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1487 - ServerB21 [Server-Type-B4]:
1488 - testbedname: testbed34.
1489 - hostname: s21-t34-sut2.
1491 - Host IP: 10.30.51.42
1493 - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1494 - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1497 #### 3-Node-Denverton Servers (3n-dnv) WIP
1500 - ServerB30 [Server-Type-B10]:
1501 - testbednames: testbed35.
1502 - hostname: s30-t35-sut1.
1503 - IPMI IP: 10.30.55.12
1504 - Host IP: 10.32.8.12
1506 - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1507 - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1508 - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1509 - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1510 - ServerB31 [Server-Type-B10]:
1511 - testbednames: testbed35.
1512 - hostname: s31-t35-sut2.
1513 - IPMI IP: 10.30.55.13
1514 - Host IP: 10.32.8.13
1516 - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1517 - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1518 - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1519 - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1522 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1528 ### Per Testbed Wiring
1530 #### 1-Node-Skylake Wiring (1n-skx) PROD
1534 - ring1 10GE-ports x710-4p10GE:
1535 - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1536 - ring2 10GE-ports x710-4p10GE:
1537 - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1538 - ring3 10GE-ports x710-4p10GE:
1539 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1540 - ring4 10GE-ports x710-4p10GE:
1541 - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1543 - ring1 10GE-ports x710-4p10GE:
1544 - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1545 - ring2 10GE-ports x710-4p10GE:
1546 - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1547 - ring3 10GE-ports x710-4p10GE:
1548 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1549 - ring4 10GE-ports x710-4p10GE:
1550 - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1553 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1557 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1558 - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
1559 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1560 - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
1561 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1562 - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
1563 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1564 - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
1567 - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1568 - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
1569 - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1570 - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
1571 - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1572 - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
1573 - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
1574 - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
1577 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1581 - ring1 10GE-ports x710-4p10GE:
1582 - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1583 - ring2 10GE-ports x710-4p10GE:
1584 - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1585 - ring3 10GE-ports x710-4p10GE:
1586 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1587 - ring4 10GE-ports x710-4p10GE:
1588 - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1591 #### 2-Node-Skylake Wiring (2n-skx) PROD
1595 - ring1 10GE-ports x710-4p10GE on SUT:
1596 - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1597 - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1598 - ring2 10GE-ports x710-4p10GE on SUT:
1599 - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1600 - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1601 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1602 - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1603 - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1605 - ring1 10GE-ports x710-4p10GE on SUT:
1606 - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1607 - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1608 - ring2 10GE-ports x710-4p10GE on SUT:
1609 - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1610 - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1611 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1612 - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1613 - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1615 - ring1 10GE-ports x710-4p10GE on SUT:
1616 - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1617 - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1618 - ring2 10GE-ports x710-4p10GE on SUT:
1619 - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1620 - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1621 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1622 - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1623 - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1625 - ring1 10GE-ports x710-4p10GE on SUT:
1626 - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1627 - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1628 - ring2 10GE-ports x710-4p10GE on SUT:
1629 - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1630 - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1631 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1632 - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1633 - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1636 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1640 - ring1 10GE-ports x553 copper port on SUT:
1641 - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1642 - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1643 - ring2 10GE-ports x553 fiber port on SUT:
1644 - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1645 - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1648 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1652 - link1 10GE-port x710-4p10GE on SUT:
1653 - t25-tg1-p1 to t25-sut1-c2/p1.
1654 - link2 10GE-port x710-4p10GE on SUT:
1655 - t25-tg1-p2 to t25-sut1-c2/p2.
1656 - link3 10GE-port x710-4p10GE on SUT:
1657 - t25-tg1-p3 to t25-sut1-c2/p3.
1658 - link4 10GE-port x710-4p10GE on SUT:
1659 - t25-tg1-p4 to t25-sut1-c2/p4.
1662 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1666 - ring1 10GE-ports x710-4p10GE on SUT:
1667 - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1668 - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1669 - ring2 10GE-ports x710-4p10GE on SUT:
1670 - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1671 - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1672 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1673 - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1674 - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1675 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1676 - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1677 - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1679 - ring1 10GE-ports x710-4p10GE on SUT:
1680 - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1681 - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1682 - ring2 10GE-ports x710-4p10GE on SUT:
1683 - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1684 - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1685 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1686 - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1687 - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1688 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1689 - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1690 - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1692 - ring1 10GE-ports x710-4p10GE on SUT:
1693 - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1694 - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1695 - ring2 10GE-ports x710-4p10GE on SUT:
1696 - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1697 - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1698 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1699 - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1700 - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1701 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1702 - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1703 - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1706 #### 2-Node-Zen2 Wiring (2n-zen2) SETUP
1710 - ring1 10GE-ports x710-4p10GE on SUT:
1711 - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1712 - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1713 - ring2 10GE-ports x710-4p10GE on SUT:
1714 - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1715 - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1716 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1717 - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1718 - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1719 - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1720 - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1721 - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1724 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1728 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1729 - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1730 - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1731 - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1732 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1733 - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1734 - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1735 - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1736 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1737 - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1738 - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1739 - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1740 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1741 - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1742 - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1743 - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1744 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1745 - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1746 - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1747 - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1748 - TG loopback ports Intel NIC x710 2p10GE
1749 - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1752 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1753 - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1754 - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1755 - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1756 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1757 - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1758 - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1759 - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1760 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1761 - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1762 - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1763 - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1764 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1765 - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1766 - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1767 - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1768 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1769 - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1770 - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1771 - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1772 - TG loopback ports Intel NIC x710 2p10GE
1773 - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1776 - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1777 - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1778 - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1779 - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1780 - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1781 - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1782 - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1783 - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1784 - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1785 - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1786 - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1787 - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1788 - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1789 - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1790 - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1791 - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1792 - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1793 - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1794 - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1795 - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1796 - TG loopback ports Intel NIC x710 2p10GE
1797 - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1800 #### 3-Node-Skylake Wiring (3n-skx) PROD
1804 - ring1 10GE-ports x710-4p10GE on SUTs:
1805 - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1806 - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1807 - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1808 - ring2 10GE-ports x710-4p10GE on SUT:
1809 - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1810 - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1811 - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1812 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1813 - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1814 - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1815 - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1816 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1817 - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1818 - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1819 - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1820 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1821 - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1822 - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1824 - ring1 10GE-ports x710-4p10GE on SUTs:
1825 - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1826 - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1827 - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1828 - ring2 10GE-ports x710-4p10GE on SUT:
1829 - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1830 - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1831 - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1832 - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1833 - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1834 - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1835 - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1836 - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1837 - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1838 - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1839 - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1840 - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1841 - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1842 - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1845 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1851 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1855 - ring1 10GE-ports x520-2p10GE on SUTs:
1856 - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1857 - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1858 - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1859 - ring2 25GE-ports cx4-2p25GE on SUTs:
1860 - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1861 - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1862 - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1865 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1869 - ring1 10GE-ports Marvell on SUTs:
1870 - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1871 - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1872 - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1875 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1879 - ring1 10GE-ports x553 copper port on SUTs:
1880 - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1881 - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1882 - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1883 - ring2 10GE-ports x553 fiber port on SUTs:
1884 - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1885 - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1886 - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1894 1. Ixia PerfectStorm One Appliance
1896 - Chassis: PS10GE4NG.
1897 - Motherboard: SuperMicro X11DPG-QT.
1898 - Processors: Quad-Core, Intel Processor.
1899 - HW accelerators: FPGA offload.
1901 - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1902 - Physical Interfaces: 4 * 10GE SFP+.
1903 - Operating System: Native IxOS.
1909 1. Arm Cortex A-72 servers
1910 - 2 * ThunderX2 (VPP Device)
1911 - Chassis: GIGABYTE Rack Mount
1912 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2
1915 - 1 * ThunderX2 (Idle)
1916 - Chassis: Marvell ThunderX2
1917 - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1918 - RAM Memory: 4* 32GB RDIMM
1919 - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1920 - 2 * Huawei TaiShan 2280.
1921 - Chassis: Huawei TaiShan 2280.
1922 - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1923 - RAM Memory: 8* 16GB DDR4-2400MT/s.
1924 - Disks: 1* 4TB SATA HDD.
1926 - Chassis: MACCHIATObin.
1927 - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1928 - RAM Memory: 1* 16GB DDR4.
1929 - Disks: 1* 128GB(?) SATA SDD.
1932 ### Xeon and Atom Servers
1935 1. Intel Xeon servers:
1936 - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1937 - Chassis: SuperMicro SYS-7049GP-TRT.
1938 - Motherboard: SuperMicro X11DPG-QT.
1939 - Processors: 2* Intel Platinum 8180 2.5 GHz.
1940 - RAM Memory: 16* 16GB DDR4-2666MHz.
1941 - Disks: 2* 1.6TB 6G SATA SSD.
1942 2. Intel Atom servers with Rangely processors.
1943 - 3 * Netgate XG-2758-1u
1944 - Chassis: Netgate XG-2758-1u
1945 - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1946 - RAM Memory: 16GB ECC
1950 ### Network Interface Cards
1954 - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1955 - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1956 - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1958 - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1960 - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1962 - 4 * mcx556a-edat NICs (not on site yet, in transit)
1965 ### Pluggables and Cables
1971 - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1972 - 80 * 10G SR optic (generic, "Intel" compatible branded)
1978 - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1989 - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable