Infra: Ansible Nomad
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
14    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
15    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
16    1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
17    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
18 1. [Server Management](#server-management)
19    1. [Requirements](#requirements)
20    1. [Addressing](#addressing)
21    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
22    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
23 1. [Server Specifications](#server-specifications)
24    1. [Server Types](#server-types)
25    1. [Naming Convention](#naming-convention)
26 1. [Testbeds Configuration](#testbeds-configuration)
27    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
28       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
29       1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
30       1. [1-Node-Cascadelake Servers (1n-clx) SETUP](#1-node-cascadelake-servers-1n-clx-setup)
31       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
32       1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
33       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
34       1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
35       1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
36       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
37       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
38       1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
39       1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
40    1. [Per Testbed Wiring](#per-testbed-wiring)
41       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
42       1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
43       1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
44       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
45       1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
46       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
47       1. [2-Node-Cascadelake Wiring (2n-clx) SETUP](#2-node-cascadelake-wiring-2n-clx-setup)
48       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
49       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
50       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
51       1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
52       1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
53 1. [Inventory](#inventory)
54    1. [Appliances](#appliances)
55    1. [Arm Servers](#arm-servers)
56    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
57    1. [Network Interface Cards](#network-interface-cards)
58    1. [Pluggables and Cables](#pluggables-and-cables)
59    1. [Other Parts](#other-parts)
60
61 ## Purpose
62
63 This note includes specification of the physical testbed infrastructure
64 hosted by LFN FD.io CSIT project.
65
66 ## Testbeds Overview
67
68 ### Summary List
69
70 ```
71  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb
72  1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0
73  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0
74  3. 1-Node-Thunderx2   dev    tx2   na    1    1    0    0    0    0    0    0    1    0    0
75  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0
76  5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0
77  6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0
78  7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0
79  8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0
80  9. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0
81 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0
82 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0
83 12. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0
84 13. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2
85 14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0
86                                  Totals: 22   35   18   12   19    1    2    3    1    2    2
87 ```
88
89 ### 1-Node-Skylake Xeon Intel (1n-skx)
90
91 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
92 ports connected back-to-back ([Server Types](#server-types)).
93 Used for FD.io VPP_Device functional driver tests.
94
95 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
96
97 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
98 ports connected back-to-back ([Server Types](#server-types)).
99 Used for FD.io VPP_Device functional driver tests.
100
101 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
102
103 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
104 NIC ports connected back-to-back ([Server Types](#server-types)).
105
106 Used for FD.io VPP_Device functional driver tests.
107
108 ### 2-Node-Skylake Xeon Intel (2n-skx)
109
110 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
111 (Server-Type-B2) connected in a 2-node circular topology
112 ([Server Types](#server-types)).
113 Used for FD.io performance tests.
114
115 ### 2-Node-Denverton Atom Intel (2n-dnv)
116
117 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
118 TG (Server-Type-B2) connected in a 2-node circular topology
119 ([Server Types](#server-types)).
120 Used for FD.io performance tests.
121
122 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
123
124 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
125 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
126 circular topology ([Server Types](#server-types)).
127 Used for FD.io TCP/IP and HTTP performance tests.
128
129 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
130
131 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
132 one TG (Server-Type-C3) connected in a 2-node circular topology
133 ([Server Types](#server-types)).
134 Used for FD.io performance tests.
135
136 ### 3-Node-Haswell Xeon Intel (3n-hsw)
137
138 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
139 TG (Server-Type-A2) connected in a 3-node circular topology
140 ([Server Types](#server-types)).
141 Used for FD.io performance tests.
142
143 ### 3-Node-Skylake Xeon Intel (3n-skx)
144
145 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
146 TG (Server-Type-B2) connected in a 3-node circular topology.
147 Used for FD.io performance tests.
148
149 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
150
151 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
152 TG (Server-Type-B2) connected in a 3-node circular topology
153 ([Server Types](#server-types)).
154 Used for FD.io performance tests.
155
156 ### 3-Node-MACCHIATObin Arm Marvell
157
158 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
159 one TG (Server-Type-B2) connected in a 3-node circular topology
160 ([Server Types](#server-types)).
161 Used for FD.io performance tests.
162
163 ### 3-Node-Rangeley Atom Testbeds
164
165 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
166 TG (Server-Type-2) connected in a 3-node circular topology
167 ([Server Types](#server-types)).
168 Used for FD.io performance tests.
169
170 ## Server Management
171
172 ### Requirements
173
174 For management purposes, each server must have following two ports
175 connected to the management network:
176
177 ```
178 - 1GE IPMI port
179   - IPMI - Intelligent Platform Management Interface.
180   - Required for access to embedded server management with WebUI, CLI,
181     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
182 - 1GE/10GE/40GE management port
183   - hostOS management port for general system management.
184 ```
185
186 ### Addressing
187
188 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
189 Management port, which are connected to two different VLANs.
190
191 ```
192 1. LOM (IPMI) VLAN:
193     - Subnet: 10.30.50.0/24
194     - Gateway: 10.30.50.1
195     - Broadcast: 10.30.50.255
196     - DNS1: 199.204.44.24
197     - DNS2: 199.204.47.54
198 2. Management Vlan:
199     - Subnet: 10.30.51.0/24
200     - Gateway: 10.30.51.1
201     - Broadcast: 10.30.51.255
202     - DNS1: 199.204.44.24
203     - DNS2: 199.204.47.54
204 ```
205
206 To access these hosts, VPN connection is required.
207
208 ### LOM (IPMI) VLAN IP Addresses
209
210 Name         | Comment
211 ------------ | -------
212 10.30.50.0   | network
213 10.30.51.1   | Router
214 10.30.50.2   | LF Reserved
215 10.30.50.3   | LF Reserved
216 10.30.50.4   | LF Reserved
217 10.30.50.5   | LF Reserved
218 10.30.50.6   | LF Reserved
219 10.30.50.7   | LF Reserved
220 10.30.50.8   | LF Reserved
221 10.30.50.9   | LF Reserved
222 10.30.50.10  | LF Reserved
223 10.30.50.11  | LF Reserved
224 10.30.50.12  | LF Reserved
225 10.30.50.13  | LF Reserved
226 10.30.50.14  | LF Reserved
227 10.30.50.15  | LF Reserved
228 10.30.50.16  | t1-tg1
229 10.30.50.17  | t1-sut1
230 10.30.50.18  | t1-sut2
231 10.30.50.20  | t2-tg1
232 10.30.50.21  | t2-sut1
233 10.30.50.22  | t2-sut2
234 10.30.50.24  | t3-tg1
235 10.30.50.25  | t3-sut1
236 10.30.50.26  | t3-sut-2
237 10.30.50.28  | s41-nomad
238 10.30.50.29  | s39-nomad
239 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
240 10.30.50.30  | s40-nomad
241 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
242 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
243 10.30.50.32  | s42-nomad (formerly nomad1)
244 10.30.50.33  | s43-nomad (formerly nomad2)
245 10.30.50.34  | s44-nomad (formerly nomad3)
246 10.30.50.35  | s45-nomad (formerly nomad4)
247 10.30.50.36  | s17-t33-sut1
248 10.30.50.37  | s18-t33-sut2
249 10.30.50.41  | s3-t21-sut1
250 10.30.50.42  | s4-t21-tg1
251 10.30.50.43  | s11-t31-sut1
252 10.30.50.44  | s12-t31-sut2
253 10.30.50.45  | s13-t31-tg1
254 10.30.50.46  | s19-t33t34-tg1
255 10.30.50.47  | s1-t11-sut1
256 10.30.50.48  | s2-t12-sut1
257 10.30.50.49  | s5-t22-sut1
258 10.30.50.50  | s6-t22-tg1
259 10.30.50.51  | s7-t23-sut1
260 10.30.50.52  | s8-t23-tg1
261 10.30.50.53  | s9-t24-sut1
262 10.30.50.54  | s10-t24-tg1
263 10.30.50.55  | s14-t32-sut1
264 10.30.50.56  | s15-t32-sut2
265 10.30.50.57  | s16-t32-tg1
266 10.30.50.58  | s25-t25-sut1
267 10.30.50.59  | s26-t25-tg1
268 10.30.50.66  | s51-nomad
269 10.30.50.67  | s49-nomad
270 10.30.50.68  | s50-nomad
271 10.30.50.69  | s27-t13-sut
272 10.30.50.255 | Broadcast
273 n/a          | s20-t34-sut1
274 n/a          | s21-t34-sut2
275 10.30.55.0   | network
276 10.30.55.1   | Router
277 10.30.55.10  | s28-t26t35-tg1
278 10.30.55.11  | s29-t26-sut1
279 10.30.55.12  | s30-t35-sut1
280 10.30.55.13  | s31-t35-sut2
281 10.30.55.14  | s46-nomad (formerly server-type-c4-1)
282 10.30.55.15  | s47-nomad (formerly server-type-c4-2)
283 10.30.55.16  | s48-nomad (formerly server-type-c4-3)
284 10.30.55.17  | s32-t14-sut1
285 10.30.55.18  | s33-t27-sut1
286 10.30.55.19  | s34-t27-tg1
287 10.30.55.20  | s35-t28-sut1
288 10.30.55.21  | s36-t28-tg1
289 10.30.55.22  | s37-t29-sut1
290 10.30.55.23  | s38-t29-tg1
291 10.30.55.255 | Broadcast
292
293 ### Management VLAN IP Addresses
294
295 Name                      | Comment
296 ------------------------- | -------
297 10.30.51.0                | network
298 10.30.51.1                | Router
299 10.30.51.2                | LF Reserved
300 10.30.51.3                | LF Reserved
301 10.30.51.4                | LF Reserved
302 10.30.51.5                | LF Reserved
303 10.30.51.6                | LF Reserved
304 10.30.51.7                | LF Reserved
305 10.30.51.8                | LF Reserved
306 10.30.51.9                | s22-t35-sut1 (netgate-1)
307 10.30.51.10               | s23-t35-sut2 (netgate-2)
308 10.30.51.11               | s24-t35-sut3 (netgate-3)
309 10.30.51.12               | softiron-1
310 10.30.51.13               | softiron-2
311 10.30.51.14               | softiron-3
312 10.30.51.15               | LF Reserved
313 10.30.51.16               | t1-tg1
314 10.30.51.17               | t1-sut1
315 10.30.51.18               | t1-sut2
316 10.30.51.20               | t2-tg1
317 10.30.51.21               | t2-sut1
318 10.30.51.22               | t2-sut2
319 10.30.51.24               | t3-tg1
320 10.30.51.25               | t3-sut1
321 10.30.51.26               | t3-sut-2
322 10.30.51.28               | s41-nomad
323 10.30.51.29               | s39-nomad
324 10.30.51.30               | s40-nomad
325 10.30.51.32               | s42-nomad (formerly nomad1)
326 10.30.51.33               | s43-nomad (formerly nomad2)
327 10.30.51.34               | s44-nomad (formerly nomad3)
328 10.30.51.35               | s45-nomad (formerly nomad4)
329 10.30.51.36               | s17-t33-sut1
330 10.30.51.37               | s18-t33-sut2
331 10.30.51.41               | s20-t34-sut1
332 10.30.51.42               | s21-t34-sut2
333 10.30.51.44               | s3-t21-sut1
334 10.30.51.45               | s4-t21-tg1
335 10.30.51.46               | s11-t31-sut1
336 10.30.51.47               | s12-t31-sut2
337 10.30.51.48               | s13-t31-tg1
338 10.30.51.49               | s19-t33t34-tg1
339 10.30.51.50               | s1-t11-sut1
340 10.30.51.51               | s2-t12-sut1
341 10.30.51.52               | s5-t22-sut1
342 10.30.51.53               | s6-t22-tg1
343 10.30.51.54               | s7-t23-sut1
344 10.30.51.55               | s8-t23-tg1
345 10.30.51.56               | s9-t24-sut1
346 10.30.51.57               | s10-t24-tg1
347 10.30.51.58               | s14-t32-sut1
348 10.30.51.59               | s15-t32-sut2
349 10.30.51.60               | s16-t32-tg1
350 10.30.51.61               | s25-t25-sut1
351 10.30.51.62               | s26-t25-tg1
352 10.30.51.66               | s51-nomad
353 10.30.51.67               | s49-nomad
354 10.30.51.68               | s50-nomad
355 10.30.51.69               | s27-t13-sut1
356 10.30.51.70-10.30.51.105  | FREE
357 10.30.51.106-10.30.51.180 | FREE
358 10.30.51.181-10.30.51.254 | FREE
359 10.30.51.255              | Broadcast
360 10.32.8.0                 | network
361 10.32.8.1                 | Router
362 10.32.8.10                | s28-t26t35-tg1
363 10.32.8.11                | s29-t26-sut1
364 10.32.8.12                | s30-t35-sut1
365 10.32.8.13                | s31-t35-sut2
366 10.32.8.14                | s46-nomad (formerly server-type-c4-1)
367 10.32.8.15                | s47-nomad (formerly server-type-c4-2)
368 10.32.8.16                | s48-nomad (formerly server-type-c4-3)
369 10.32.8.17                | s32-t14-sut1
370 10.32.8.18                | s33-t27-sut1
371 10.32.8.19                | s34-t27-tg1
372 10.32.8.20                | s35-t28-sut1
373 10.32.8.21                | s36-t28-tg1
374 10.32.8.22                | s37-t29-sut1
375 10.32.8.23                | s38-t29-tg1
376 10.32.8.255               | Broadcast
377
378 ## Server Specifications
379
380 ### Server Types
381
382 FD.io CSIT lab contains following server types:
383 ```
384 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
385     - Quantity: 6 servers.
386     - Physical connectivity:
387         - CIMC and host management ports.
388         - NIC ports connected in 3-node topologies.
389     - Main HW configuration:
390         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
391         - Processors: 2* E5-2699v3 2.3 GHz.
392         - RAM Memory: 16* 32GB DDR4-2133MHz.
393         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
394     - NICs configuration:
395         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
396             - PCIe Slot1: Cisco VIC 1385 2p40GE.
397             - PCIe Slot2: Intel NIC x520 2p10GE.
398             - PCIe Slot3: empty.
399         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
400             - PCIe Slot4: Intel NIC xl710 2p40GE.
401             - PCIe Slot5: Intel NIC x710 2p10GE.
402             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
403         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
404 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
405     - Quantity: 3 servers.
406     - Physical connectivity:
407         - CIMC and host management ports.
408         - NIC ports connected in 3-node topologies.
409     - Main HW configuration:
410         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
411         - Processors: 2* E5-2699v3 2.3 GHz.
412         - RAM Memory: 16* 32GB DDR4-2133MHz.
413         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
414     - NICs configuration:
415         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
416             - PCIe Slot1: Intel NIC xl710 2p40GE.
417             - PCIe Slot2: Intel NIC x710 2p10GE.
418             - PCIe Slot3: Intel NIC x710 2p10GE.
419         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
420             - PCIe Slot4: Intel NIC xl710 2p40GE.
421             - PCIe Slot5: Intel NIC x710 2p10GE.
422             - PCIe Slot6: Intel NIC x710 2p10GE.
423         - MLOM slot: empty.
424 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
425     - Quantity: 3 servers.
426     - Physical connectivity:
427         - CIMC and host management ports.
428         - no NIC ports, standalone setup.
429     - Main HW configuration:
430         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
431         - Processors: 2* E5-2699v3 2.3 GHz.
432         - RAM Memory: 16* 32GB DDR4-2133MHz.
433         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
434     - NICs configuration:
435         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
436             - no cards.
437         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
438             - no cards.
439         - MLOM slot: empty.
440 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
441     - Quantity: ---
442     - Physical connectivity:
443         - IPMI and host management ports.
444         - NIC ports connected into 2-node and 3-node topologies.
445     - Main HW configuration:
446         - Chassis: SuperMicro SYS-7049GP-TRT.
447         - Motherboard: SuperMicro X11DPG-QT.
448         - Processors: 2* Intel Platinum 8180 2.5 GHz.
449         - RAM Memory: 16* 16GB DDR4-2666MHz.
450         - Disks: 2* 1.6TB 6G SATA SSD.
451     - NICs configuration:
452         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
453             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
454             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
455             - PCIe Slot9 5e:00.xx: empty.
456         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
457             - PCIe Slot6 86:00.xx: empty.
458             - PCIe Slot8 af:00.xx: empty.
459             - PCIe Slot10 d8:00.xx: empty.
460 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
461     - Quantity: ---
462     - Physical connectivity:
463         - IPMI and host management ports.
464         - NIC ports connected into 2-node and 3-node topologies.
465     - Main HW configuration:
466         - Chassis: SuperMicro SYS-7049GP-TRT.
467         - Motherboard: SuperMicro X11DPG-QT.
468         - Processors: 2* Intel Platinum 8180 2.5 GHz.
469         - RAM Memory: 16* 16GB DDR4-2666MHz.
470         - Disks: 2* 1.6TB 6G SATA SSD.
471     - NICs configuration:
472         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
473             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
474             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
475             - PCIe Slot9 5e:00.xx: empty.
476         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
477             - PCIe Slot6 86:00.xx: empty.
478             - PCIe Slot8 af:00.xx: empty.
479             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
480 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
481     - Quantity: 2
482     - Physical connectivity:
483         - IPMI(?) and host management ports.
484         - NIC ports connected into 3-node topology.
485     - Main HW configuration:
486         - Chassis: Huawei TaiShan 2280.
487         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
488         - RAM Memory: 8* 16GB DDR4-2400MT/s
489         - Disks: 1* 4TB SATA HDD
490     - NICs configuration:
491         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
492         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
493 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
494     - Quantity: 3
495     - Physical connectivity:
496         - Host management ports.
497         - NIC ports connected into 2-node and 3-node topologies.
498     - Main HW configuration:
499         - Chassis: MACCHIATObin.
500         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
501         - RAM Memory: 1* 16GB DDR4
502         - Disks: 1* 128GB(?) SATA SDD
503     - NICs configuration:
504         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
505 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
506     - Quantity: TBD based on testbed allocation.
507     - Physical connectivity:
508         - Management: serial Port (usb) for console
509         - NIC ports connected into 2-node.
510     - Main HW configuration:
511         - Chassis: Netgate XG-2758-1u
512         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
513         - RAM Memory: 16GB ECC
514         - Disks: 150 GB
515     - NICs configuration:
516         - 2x 10Gb Intel 82599ES
517         - 4x 1GB Intel I354
518 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
519     - Quantity: 2.
520     - Physical connectivity:
521         - IPMI and host management ports.
522         - NIC ports connected into 2-node and 3-node topologies.
523     - Main HW configuration:
524         - Chassis: SuperMicro SYS-7049GP-TRT.
525         - Motherboard: SuperMicro X11DPG-QT.
526         - Processors: 2* Intel Platinum 8180 2.5 GHz.
527         - RAM Memory: 16* 16GB DDR4-2666MHz.
528         - Disks: 2* 1.6TB 6G SATA SSD.
529     - NICs configuration:
530         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
531             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
532             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
533             - PCIe Slot9 5e:00.xx: empty.
534         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
535             - PCIe Slot6 86:00.xx: empty.
536             - PCIe Slot8 af:00.xx: empty.
537             - PCIe Slot10 d8:00.xx: empty.
538 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
539     - Quantity: 1.
540     - Physical connectivity:
541         - Host management interface: 10/100/1000-BaseT.
542         - 8-port 10GE SFP+ integrated NIC.
543     - Main HW configuration:
544         - Chassis: PS10GE4NG.
545         - Motherboard: SuperMicro X11DPG-QT.
546         - Processors: Quad-Core, Intel Processor.
547         - HW accelerators: FPGA offload.
548         - RAM Memory: 64GB.
549         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
550         - Physical Interfaces: 4 * 10GE SFP+.
551         - Operating System: Native IxOS.
552     - Interface configuration:
553         - Port-1: 10GE SFP+.
554         - Port-2: 10GE SFP+.
555         - Port-3: 10GE SFP+.
556         - Port-4: 10GE SFP+.
557 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
558     - Quantity: 1.
559     - Physical connectivity:
560         - IPMI and host management ports.
561         - NIC ports.
562     - Main HW configuration:
563         - Chassis: SuperMicro SYS-7049GP-TRT.
564         - Motherboard: SuperMicro X11DPG-QT.
565         - Processors: 2* Intel Platinum 8180 2.5 GHz.
566         - RAM Memory: 16* 16GB DDR4-2666MHz.
567         - Disks: 2* 1.6TB 6G SATA SSD.
568     - NICs configuration:
569         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
570             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
571             - PCIe Slot4 3b:00.xx: empty.
572             - PCIe Slot9 5e:00.xx: empty.
573         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
574             - PCIe Slot6 86:00.xx: empty.
575             - PCIe Slot8 af:00.xx: empty.
576             - PCIe Slot10 d8:00.xx: empty.
577 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
578     - Quantity: 1
579     - Physical connectivity:
580         - IPMI and host management ports.
581         - NIC ports connected into 1-node topologies.
582     - Main HW configuration:
583         - Chassis: Gigabyte R181-T90 1U
584         - Motheboard: MT91-FS1
585         - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
586         - RAM Memory: 4* 32GB RDIMM
587         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
588     - NICs configuration:
589         - Numa0:
590             - PCIe Slot1 05:00.xx: XL710-QDA2.
591             - PCIe Slot3 08:00.xx: XL710-QDA2.
592         - Numa1:
593             - PCIe Slot6 85:00.xx: XL710-QDA2.
594 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
595     - Quantity: 4
596     - Physical connectivity:
597         - IPMI and host management ports.
598         - NIC ports.
599     - Main HW configuration:
600         - Chassis: SuperMicro SYS-E300-9A
601         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
602         - RAM Memory: 32GB ECC
603         - Disks: 480 GB
604     - NICs configuration:
605         - 2x 10Gb Intel x553 fiber ports
606         - 2x 10Gb Intel x553 copper ports
607         - 4x 1GB Intel I350 ports
608
609 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
610     - Quantity: 1.
611     - Physical connectivity:
612         - IPMI and host management ports.
613         - NIC ports connected into 1-node testbed topologies.
614     - Main HW configuration:
615         - Chassis: SuperMicro SYS-7049GP-TRT.
616         - Motherboard: SuperMicro X11DPG-QT.
617         - Processors: 2* Intel Platinum 8280 2.7 GHz.
618         - RAM Memory: 12* 16GB DDR4-2933.
619         - Disks: 2* 1.92TB SATA SSD.
620     - NICs configuration:
621         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
622             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
623             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
624             - PCIe Slot9 5e:00.xx: empty.
625         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
626             - PCIe Slot6 86:00.xx: empty.
627             - PCIe Slot8 af:00.xx: empty.
628             - PCIe Slot10 d8:00.xx: empty.
629
630 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
631     - Quantity: 3
632     - Physical connectivity:
633         - IPMI and host management ports.
634         - NIC ports connected into 2-node testbed topologies.
635     - Main HW configuration:
636         - Chassis: SuperMicro SYS-7049GP-TRT.
637         - Motherboard: SuperMicro X11DPG-QT.
638         - Processors: 2* Intel Gold 6252N 2.3 GHz.
639         - RAM Memory: 12* 16GB DDR4-2933.
640         - Disks: 2* 1.92TB SATA SSD.
641     - NICs configuration:
642         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
643             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
644             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
645             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
646               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
647         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
648             - PCIe Slot6 86:00.xx: empty.
649             - PCIe Slot8 af:00.xx: empty.
650             - PCIe Slot10 d8:00.xx: empty.
651 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
652     - Quantity: 3.
653     - Physical connectivity:
654         - IPMI and host management ports.
655         - NIC ports connected into 2-node testbed topologies.
656     - Main HW configuration:
657         - Chassis: SuperMicro SYS-7049GP-TRT.
658         - Motherboard: SuperMicro X11DPG-QT.
659         - Processors: 2* Intel Platinum 8280 2.7 GHz.
660         - RAM Memory: 12* 16GB DDR4-2933.
661         - Disks: 2* 1.92TB SATA SSD.
662     - NICs configuration:
663         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
664             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
665             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
666             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
667               - Only 4 of mcx556a-edat ConnectX5-2p100GE NICs are in the lab, so only two out of three 2-node testbeds are equipped with them.
668         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
669             - PCIe Slot6 86:00.xx: empty.
670             - PCIe Slot8 af:00.xx: empty.
671             - PCIe Slot10 d8:00.xx: empty.
672
673 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
674     - Quantity: 3.
675     - Physical connectivity:
676         - CIMC and host management ports.
677         - no NIC ports, standalone setup.
678     - Main HW configuration:
679         - Chassis: SuperMicro 1029P-WTRT.
680         - Motherboard: SuperMicro X11DDW-NT.
681         - Processors: 2* Intel Platinum 8280 2.7 GHz.
682         - RAM Memory: 12* 16GB DDR4-2933.
683         - Disks: 4* 1.92TB SATA SSD.
684     - NICs configuration:
685         - Numa0:
686             - no cards.
687         - Numa1:
688             - no cards.
689 ```
690
691 ### Naming Convention
692
693 Following naming convention is used within this page to specify physical
694 connectivity and wiring across defined CSIT testbeds:
695
696 ```
697 - testbedname: testbedN.
698 - hostname:
699     - traffic-generator: tN-tgW.
700     - system-under-testX: tN-sutX.
701 - portnames:
702     - tN-tgW-cY/pZ.
703     - tN-sutX-cY/pZ.
704 - where:
705     - N - testbed number.
706     - tgW - server acts as traffic-generator with W index.
707     - sutX - server acts as system-under-test with X index.
708     - Y - PCIe slot number denoting a NIC card number within the host.
709     - Z - port number on the NIC card.
710 ```
711
712 ## Testbeds Configuration
713
714 ### Per Testbed Server Allocation and Naming
715
716 #### 1-Node-Skylake Servers (1n-skx) PROD
717
718 ```
719 - SUT [Server-Type-B6]:
720     - testbedname: testbed11.
721     - hostname: s1-t11-sut1.
722     - IPMI IP: 10.30.50.47
723     - Host IP: 10.30.51.50
724     - portnames:
725         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
726         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
727         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
728         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
729         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
730         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
731         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
732         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
733 - SUT [Server-Type-B6]:
734     - testbedname: testbed12.
735     - hostname: s2-t12-sut1.
736     - IPMI IP: 10.30.50.48
737     - Host IP: 10.30.51.51
738     - portnames:
739         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
740         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
741         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
742         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
743         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
744         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
745         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
746         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
747 ```
748
749 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
750
751 ```
752 - SUT [Server-Type-B9]:
753     - testbedname: testbed13.
754     - hostname: s27-t13-sut1.
755     - IPMI IP: 10.30.50.69
756     - Host IP: 10.30.51.69
757     - portnames:
758         - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
759         - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
760         - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
761         - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
762         - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
763         - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
764 ```
765
766 #### 1-Node-Cascadelake Servers (1n-clx) SETUP
767
768 ```
769 - SUT [Server-Type-C1]:
770     - testbedname: testbed11.
771     - hostname: s32-t14-sut1.
772     - IPMI IP: 10.30.55.17
773     - Host IP: 10.32.8.17
774     - portnames:
775         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
776         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
777         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
778         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
779         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
780         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
781         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
782         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
783 ```
784
785 #### 2-Node-Skylake Servers (2n-skx) PROD
786
787 ```
788 - SUT [Server-Type-B1]:
789     - testbedname: testbed21.
790     - hostname: s3-t21-sut1.
791     - IPMI IP: 10.30.50.41
792     - Host IP: 10.30.51.44
793     - portnames:
794         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
795         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
796         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
797         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
798         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
799         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
800 - TG [Server-Type-B2]:
801     - testbedname: testbed21.
802     - hostname: s4-t21-tg1.
803     - IPMI IP: 10.30.50.42
804     - Host IP: 10.30.51.45
805     - portnames:
806         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
807         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
808         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
809         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
810         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
811         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
812 - SUT [Server-Type-B1]:
813     - testbedname: testbed22.
814     - hostname: s5-t22-sut1.
815     - IPMI IP: 10.30.50.49
816     - Host IP: 10.30.51.52
817     - portnames:
818         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
819         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
820         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
821         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
822         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
823         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
824 - TG [Server-Type-B2]:
825     - testbedname: testbed22.
826     - hostname: s6-t22-tg1.
827     - IPMI IP: 10.30.50.50
828     - Host IP: 10.30.51.53
829     - portnames:
830         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
831         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
832         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
833         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
834         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
835         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
836 - SUT [Server-Type-B1]:
837     - testbedname: testbed23.
838     - hostname: s7-t23-sut1.
839     - IPMI IP: 10.30.50.51
840     - Host IP: 10.30.51.54
841     - portnames:
842         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
843         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
844         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
845         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
846         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
847         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
848 - TG [Server-Type-B2]:
849     - testbedname: testbed23.
850     - hostname: s8-t23-tg1.
851     - IPMI IP: 10.30.50.52
852     - Host IP: 10.30.51.55
853     - portnames:
854         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
855         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
856         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
857         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
858         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
859         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
860 - SUT [Server-Type-B1]:
861     - testbedname: testbed24.
862     - hostname: s9-t24-sut1.
863     - IPMI IP: 10.30.50.53
864     - Host IP: 10.30.51.56
865     - portnames:
866         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
867         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
868         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
869         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
870         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
871         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
872 - TG [Server-Type-B2]:
873     - testbedname: testbed24.
874     - hostname: s10-t24-tg1.
875     - IPMI IP: 10.30.50.54
876     - Host IP: 10.30.51.57
877     - portnames:
878         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
879         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
880         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
881         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
882         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
883         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
884 ```
885
886 #### 2-Node-Denverton Servers (2n-dnv) WIP
887
888 Note: ServerB28 (TG) is shared between testbed26 & testbed35
889
890 ```
891 - TG [Server-Type-B2]:
892     - testbednames: testbed26 and testbed35.
893     - hostname: s28-t26t35-tg1.
894     - IPMI IP: 10.30.55.10
895     - Host IP: 10.32.8.10
896     - portnames:
897         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
898         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
899         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
900         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
901         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
902         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
903         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
904         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
905         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
906         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
907         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
908         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
909 - SUT [Server-Type-B10]:
910     - testbednames: testbed26.
911     - hostname: s29-t26-sut1.
912     - IPMI IP: 10.30.55.11
913     - Host IP: 10.32.8.11
914     - portnames:
915         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
916         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
917         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
918         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
919 ```
920
921 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
922
923 ```
924 - SUT [Server-Type-B8]:
925     - testbedname: testbed25.
926     - hostname: s25-t25-sut1.
927     - IPMI IP: 10.30.50.58
928     - Host IP: 10.30.51.61
929     - portnames:
930         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
931         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
932         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
933         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
934 - TG [Server-Type-B7]:
935     - testbedname: testbed25.
936     - hostname: s26-t25-tg1.
937     - IPMI IP: 10.30.50.59
938     - Host IP: 10.30.51.62
939     - portnames:
940         - s26-t25-tg1-p1 - 10GE-port1.
941         - s26-t25-tg1-p2 - 10GE-port2.
942         - s26-t25-tg1-p3 - 10GE-port3.
943         - s26-t25-tg1-p4 - 10GE-port4.
944 ```
945
946 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
947
948 ```
949 - SUT [Server-Type-C2]:
950     - testbedname: testbed27.
951     - hostname: s33-t27-sut1.
952     - IPMI IP: 10.30.55.18
953     - Host IP: 10.32.8.18
954     - portnames:
955         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
956         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
957         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
958         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
959         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
960         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
961         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
962         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
963 - TG [Server-Type-C3]:
964     - testbedname: testbed27.
965     - hostname: s34-t27-tg1.
966     - IPMI IP: 10.30.55.19
967     - Host IP: 10.32.8.19
968     - portnames:
969         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
970         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
971         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
972         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
973         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
974         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
975         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
976         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
977 - SUT [Server-Type-C2]:
978     - testbedname: testbed28.
979     - hostname: s35-t28-sut1.
980     - IPMI IP: 10.30.55.20
981     - Host IP: 10.32.8.20
982     - portnames:
983         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
984         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
985         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
986         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
987         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
988         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
989         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
990         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
991 - TG [Server-Type-C3]:
992     - testbedname: testbed28.
993     - hostname: s36-t28-tg1.
994     - IPMI IP: 10.30.55.21
995     - Host IP: 10.32.8.21
996     - portnames:
997         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
998         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
999         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1000         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1001         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1002         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1003         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1004         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1005 - SUT [Server-Type-C2]:
1006     - testbedname: testbed29.
1007     - hostname: s37-t29-sut1.
1008     - IPMI IP: 10.30.55.22
1009     - Host IP: 10.32.8.22
1010     - portnames:
1011         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1012         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1013         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1014         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1015         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1016         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1017         - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1018         - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1019 - TG [Server-Type-C3]:
1020     - testbedname: testbed29.
1021     - hostname: s38-t29-tg1.
1022     - IPMI IP: 10.30.55.23
1023     - Host IP: 10.32.8.23
1024     - portnames:
1025         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1026         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1027         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1028         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1029         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1030         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1031         - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1032         - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1033 ```
1034
1035 #### 3-Node-Haswell Servers (3n-hsw) PROD
1036
1037 ```
1038  1. SUT [Server-Type-A1]:
1039     - testbedname: testbed1.
1040     - hostname: t1-sut1.
1041     - CIMC IP: 10.30.50.17
1042     - Host IP: 10.30.51.17
1043     - portnames:
1044         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1045         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1046         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1047         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1048         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1049         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1050         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1051         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1052         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1053         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1054  2. SUT [Server-Type-A1]:
1055     - testbedname: testbed1.
1056     - hostname: t1-sut2.
1057     - CIMC IP: 10.30.50.18
1058     - Host IP: 10.30.51.18
1059     - portnames:
1060         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1061         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1062         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1063         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1064         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1065         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1066         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1067         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1068         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1069         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1070  3. TG [Server-Type-A2]:
1071     - testbedname: testbed1.
1072     - hostname: t1-tg1.
1073     - CIMC IP: 10.30.50.16
1074     - Host IP: 10.30.51.16
1075     - portnames:
1076         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1077         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1078         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1079         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1080         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1081         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1082         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1083         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1084         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1085         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1086         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1087         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1088  4. SUT [Server-Type-A1]:
1089     - testbedname: testbed2.
1090     - hostname: t2-sut1.
1091     - CIMC IP: 10.30.50.21
1092     - Host IP: 10.30.51.21
1093     - portnames:
1094         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1095         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1096         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1097         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1098         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1099         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1100         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1101         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1102         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1103         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1104  5. SUT [Server-Type-A1]:
1105     - testbedname: testbed2.
1106     - hostname: t2-sut2.
1107     - CIMC IP: 10.30.50.22
1108     - Host IP: 10.30.51.22
1109     - portnames:
1110         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1111         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1112         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1113         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1114         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1115         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1116         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1117         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1118         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1119         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1120  6. TG [Server-Type-A2]:
1121     - testbedname: testbed2.
1122     - hostname: t2-tg1.
1123     - CIMC IP: 10.30.50.20
1124     - Host IP: 10.30.51.20
1125     - portnames:
1126         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1127         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1128         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1129         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1130         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1131         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1132         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1133         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1134         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1135         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1136         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1137         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1138  7. SUT [Server-Type-A1]:
1139     - testbedname: testbed3.
1140     - hostname: t3-sut1.
1141     - CIMC IP: 10.30.50.25
1142     - Host IP: 10.30.51.25
1143     - portnames:
1144         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1145         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1146         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1147         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1148         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1149         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1150         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1151         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1152         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1153         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1154  8. SUT [Server-Type-A1]:
1155     - testbedname: testbed3.
1156     - hostname: t3-sut2.
1157     - CIMC IP: 10.30.50.26
1158     - Host IP: 10.30.51.26
1159     - portnames:
1160         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1161         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1162         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1163         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1164         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1165         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1166         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1167         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1168         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1169         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1170  9. TG [Server-Type-A2]:
1171     - testbedname: testbed3.
1172     - hostname: t3-tg1.
1173     - CIMC IP: 10.30.50.24
1174     - Host IP: 10.30.51.24
1175     - portnames:
1176         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1177         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1178         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1179         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1180         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1181         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1182         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1183         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1184         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1185         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1186         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1187         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1188 ```
1189
1190 #### 3-Node-Skylake Servers (3n-skx) PROD
1191
1192 ```
1193 - ServerB11 [Server-Type-B1]:
1194     - testbedname: testbed31.
1195     - hostname: s11-t31-sut1.
1196     - IPMI IP: 10.30.50.43
1197     - Host IP: 10.30.51.46
1198     - portnames:
1199         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1200         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1201         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1202         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1203         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1204         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1205         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1206         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1207 - ServerB12 [Server-Type-B1]:
1208     - testbedname: testbed31.
1209     - hostname: s12-t31-sut2.
1210     - IPMI IP: 10.30.50.44
1211     - Host IP: 10.30.51.47
1212     - portnames:
1213         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1214         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1215         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1216         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1217         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1218         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1219         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1220         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1221 - ServerB13 [Server-Type-B2]:
1222     - testbedname: testbed31.
1223     - hostname: s13-t31-tg1.
1224     - IPMI IP: 10.30.50.45
1225     - Host IP: 10.30.51.48
1226     - portnames:
1227         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1228         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1229         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1230         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1231         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1232         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1233         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1234         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1235 - ServerB14 [Server-Type-B1]:
1236     - testbedname: testbed32.
1237     - hostname: s14-t32-sut1.
1238     - IPMI IP: 10.30.50.55
1239     - Host IP: 10.30.51.58
1240     - portnames:
1241         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1242         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1243         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1244         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1245         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1246         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1247         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1248         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1249 - ServerB15 [Server-Type-B1]:
1250     - testbedname: testbed32.
1251     - hostname: s15-t32-sut2.
1252     - IPMI IP: 10.30.50.56
1253     - Host IP: 10.30.51.59
1254     - portnames:
1255         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1256         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1257         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1258         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1259         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1260         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1261         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1262         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1263 - ServerB16 [Server-Type-B2]:
1264     - testbedname: testbed32.
1265     - hostname: s16-t32-tg1.
1266     - IPMI IP: 10.30.50.57
1267     - Host IP: 10.30.51.60
1268     - portnames:
1269         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1270         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1271         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1272         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1273         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1274         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1275         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1276         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1277 ```
1278
1279 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1280
1281 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1282
1283 ```
1284 - ServerB22 [Server-Type-B5]:
1285     - testbedname: testbed35.
1286     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1287     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1288     - Host IP: 10.30.51.9
1289     - portnames:
1290         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1291         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1292     - 1GB ports (tbd)
1293 - ServerB23 [Server-Type-B5]:
1294     - testbedname: testbed35.
1295     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1296     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1297     - Host IP: 10.30.51.10
1298     - portnames:
1299         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1300         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1301     - 1GB ports (tbd)
1302 - ServerB24 [Server-Type-B5]:
1303     - testbedname: testbed35.
1304     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1305     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1306     - Host IP: 10.30.51.11
1307     - portnames:
1308         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1309         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1310     - 1GB ports (tbd)
1311 ```
1312
1313 #### 3-Node-Taishan Servers (3n-tsh) WIP
1314
1315 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1316
1317 ```
1318 - ServerB17 [Server-Type-B3]:
1319     - testbedname: testbed33.
1320     - hostname: s17-t33-sut1.
1321     - IPMI IP: 10.30.50.36
1322     - Host IP: 10.30.51.36
1323     - portnames:
1324         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1325         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1326         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1327         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1328 - ServerB18 [Server-Type-B3]:
1329     - testbedname: testbed33.
1330     - hostname: s18-t33-sut2.
1331     - IPMI IP: 10.30.50.37
1332     - Host IP: 10.30.51.37
1333     - portnames:
1334         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1335         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1336         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1337         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1338 - ServerB19 [Server-Type-B2]:
1339     - testbednames: testbed33 and testbed34.
1340     - hostname: s19-t33t34-tg1.
1341     - IPMI IP: 10.30.50.46
1342     - Host IP: 10.30.51.49
1343     - portnames:
1344         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1345         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1346         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1347         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1348         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1349         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1350         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1351         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1352         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1353         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1354 - ServerB20 [Server-Type-B4]:
1355     - testbedname: testbed34.
1356     - hostname: s20-t34-sut1.
1357     - IPMI IP: N/A
1358     - Host IP: 10.30.51.41
1359     - portnames:
1360         - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1361         - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1362 - ServerB21 [Server-Type-B4]:
1363     - testbedname: testbed34.
1364     - hostname: s21-t34-sut2.
1365     - IPMI IP: N/A
1366     - Host IP: 10.30.51.42
1367     - portnames:
1368         - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1369         - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1370 ```
1371
1372 #### 3-Node-Denverton Servers (3n-dnv) WIP
1373
1374 ```
1375 - ServerB30 [Server-Type-B10]:
1376     - testbednames: testbed35.
1377     - hostname: s30-t35-sut1.
1378     - IPMI IP: 10.30.55.12
1379     - Host IP: 10.32.8.12
1380     - portnames:
1381         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1382         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1383         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1384         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1385 - ServerB31 [Server-Type-B10]:
1386     - testbednames: testbed35.
1387     - hostname: s31-t35-sut2.
1388     - IPMI IP: 10.30.55.13
1389     - Host IP: 10.32.8.13
1390     - portnames:
1391         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1392         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1393         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1394         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1395 ```
1396
1397 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1398
1399 ```
1400 To be completed.
1401 ```
1402
1403 ### Per Testbed Wiring
1404
1405 #### 1-Node-Skylake Wiring (1n-skx) PROD
1406
1407 ```
1408 - testbed11:
1409     - ring1 10GE-ports x710-4p10GE:
1410         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1411     - ring2 10GE-ports x710-4p10GE:
1412         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1413     - ring3 10GE-ports x710-4p10GE:
1414         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1415     - ring4 10GE-ports x710-4p10GE:
1416         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1417 - testbed12:
1418     - ring1 10GE-ports x710-4p10GE:
1419         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1420     - ring2 10GE-ports x710-4p10GE:
1421         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1422     - ring3 10GE-ports x710-4p10GE:
1423         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1424     - ring4 10GE-ports x710-4p10GE:
1425         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1426 ```
1427
1428 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1429
1430 ```
1431 - testbed13:
1432     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1433         - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1434     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1435         - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1436     - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1437         - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1438 ```
1439
1440 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1441
1442 ```
1443 - testbed14:
1444     - ring1 10GE-ports x710-4p10GE:
1445         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1446     - ring2 10GE-ports x710-4p10GE:
1447         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1448     - ring3 10GE-ports x710-4p10GE:
1449         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1450     - ring4 10GE-ports x710-4p10GE:
1451         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1452 ```
1453
1454 #### 2-Node-Skylake Wiring (2n-skx) PROD
1455
1456 ```
1457 - testbed21:
1458     - ring1 10GE-ports x710-4p10GE on SUT:
1459         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1460         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1461     - ring2 10GE-ports x710-4p10GE on SUT:
1462         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1463         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1464     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1465         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1466         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1467 - testbed22:
1468     - ring1 10GE-ports x710-4p10GE on SUT:
1469         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1470         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1471     - ring2 10GE-ports x710-4p10GE on SUT:
1472         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1473         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1474     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1475         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1476         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1477 - testbed23:
1478     - ring1 10GE-ports x710-4p10GE on SUT:
1479         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1480         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1481     - ring2 10GE-ports x710-4p10GE on SUT:
1482         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1483         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1484     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1485         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1486         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1487 - testbed24:
1488     - ring1 10GE-ports x710-4p10GE on SUT:
1489         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1490         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1491     - ring2 10GE-ports x710-4p10GE on SUT:
1492         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1493         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1494     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1495         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1496         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1497 ```
1498
1499 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1500
1501 ```
1502 - testbed26:
1503     - ring1 10GE-ports x553 copper port on SUT:
1504         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1505         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1506     - ring2 10GE-ports x553 fiber port on SUT:
1507         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1508         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1509 ```
1510
1511 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1512
1513 ```
1514 - testbed25:
1515     - link1 10GE-port x710-4p10GE on SUT:
1516         - t25-tg1-p1 to t25-sut1-c2/p1.
1517     - link2 10GE-port x710-4p10GE on SUT:
1518         - t25-tg1-p2 to t25-sut1-c2/p2.
1519     - link3 10GE-port x710-4p10GE on SUT:
1520         - t25-tg1-p3 to t25-sut1-c2/p3.
1521     - link4 10GE-port x710-4p10GE on SUT:
1522         - t25-tg1-p4 to t25-sut1-c2/p4.
1523 ```
1524
1525 #### 2-Node-Cascadelake Wiring (2n-clx) SETUP
1526
1527 ```
1528 - testbed27:
1529     - ring1 10GE-ports x710-4p10GE on SUT:
1530         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1531         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1532     - ring2 10GE-ports x710-4p10GE on SUT:
1533         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1534         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1535     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1536         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1537         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1538     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1539         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1540         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1541 - testbed28:
1542     - ring1 10GE-ports x710-4p10GE on SUT:
1543         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1544         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1545     - ring2 10GE-ports x710-4p10GE on SUT:
1546         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1547         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1548     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1549         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1550         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1551     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1552         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1553         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1554 - testbed29:
1555     - ring1 10GE-ports x710-4p10GE on SUT:
1556         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1557         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1558     - ring2 10GE-ports x710-4p10GE on SUT:
1559         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1560         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1561     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1562         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1563         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1564     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1565         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1566         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1567 ```
1568
1569 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1570
1571 ```
1572  1. testbed1:
1573     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1574         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1575         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1576         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1577     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1578         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1579         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1580         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1581     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1582         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1583         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1584         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1585     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1586         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1587         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1588         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1589     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1590         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1591         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1592         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1593     - TG loopback ports Intel NIC x710 2p10GE
1594         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1595
1596  2. testbed2:
1597     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1598         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1599         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1600         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1601     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1602         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1603         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1604         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1605     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1606         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1607         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1608         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1609     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1610         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1611         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1612         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1613     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1614         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1615         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1616         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1617     - TG loopback ports Intel NIC x710 2p10GE
1618         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1619
1620  3. testbed3:
1621     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1622         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1623         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1624         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1625     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1626         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1627         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1628         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1629     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1630         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1631         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1632         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1633     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1634         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1635         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1636         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1637     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1638         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1639         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1640         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1641     - TG loopback ports Intel NIC x710 2p10GE
1642         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1643 ```
1644
1645 #### 3-Node-Skylake Wiring (3n-skx) PROD
1646
1647 ```
1648 - testbed31:
1649     - ring1 10GE-ports x710-4p10GE on SUTs:
1650         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1651         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1652         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1653     - ring2 10GE-ports x710-4p10GE on SUT:
1654         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1655         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1656         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1657     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1658         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1659         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1660         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1661     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1662         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1663         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1664         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1665     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1666         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1667         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1668 - testbed32:
1669     - ring1 10GE-ports x710-4p10GE on SUTs:
1670         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1671         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1672         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1673     - ring2 10GE-ports x710-4p10GE on SUT:
1674         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1675         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1676         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1677     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1678         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1679         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1680         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1681     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1682         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1683         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1684         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1685     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1686         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1687         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1688 ```
1689
1690 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1691
1692 ```
1693 To be completed.
1694 ```
1695
1696 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1697
1698 ```
1699 - testbed33:
1700     - ring1 10GE-ports x520-2p10GE on SUTs:
1701         - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1702         - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1703         - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1704     - ring2 25GE-ports cx4-2p25GE on SUTs:
1705         - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1706         - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1707         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1708 ```
1709
1710 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1711
1712 ```
1713 - testbed34:
1714     - ring1 10GE-ports Marvell on SUTs:
1715         - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1716         - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1717         - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1718 ```
1719
1720 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1721
1722 ```
1723 - testbed35:
1724     - ring1 10GE-ports x553 copper port on SUTs:
1725         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1726         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1727         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1728     - ring2 10GE-ports x553 fiber port on SUTs:
1729         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1730         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1731         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1732 ```
1733
1734 ## Inventory
1735
1736 ### Appliances
1737
1738 ```
1739 1. Ixia PerfectStorm One Appliance
1740     - 1 * PS10GE4NG
1741         - Chassis: PS10GE4NG.
1742         - Motherboard: SuperMicro X11DPG-QT.
1743         - Processors: Quad-Core, Intel Processor.
1744         - HW accelerators: FPGA offload.
1745         - RAM Memory: 64GB.
1746         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1747         - Physical Interfaces: 4 * 10GE SFP+.
1748         - Operating System: Native IxOS.
1749 ```
1750
1751 ### Arm Servers
1752
1753 ```
1754 1. Arm Cortex A-72 servers
1755     - 1 * ThunderX2
1756         - Chassis: Marvell ThunderX2
1757         - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1758         - RAM Memory: 4* 32GB RDIMM
1759         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1760     - 2 * Huawei TaiShan 2280.
1761         - Chassis: Huawei TaiShan 2280.
1762         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1763         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1764         - Disks: 1* 4TB SATA HDD.
1765     - 3 * MACCHIATObin
1766         - Chassis: MACCHIATObin.
1767         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1768         - RAM Memory: 1* 16GB DDR4.
1769         - Disks: 1* 128GB(?) SATA SDD.
1770 ```
1771
1772 ### Xeon and Atom Servers
1773
1774 ```
1775 1. Intel Xeon servers:
1776     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1777         - Chassis: SuperMicro SYS-7049GP-TRT.
1778         - Motherboard: SuperMicro X11DPG-QT.
1779         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1780         - RAM Memory: 16* 16GB DDR4-2666MHz.
1781         - Disks: 2* 1.6TB 6G SATA SSD.
1782 2. Intel Atom servers with Rangely processors.
1783     - 3 * Netgate XG-2758-1u
1784         - Chassis: Netgate XG-2758-1u
1785         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1786         - RAM Memory: 16GB ECC
1787         - Disks: 150 GB
1788 ```
1789
1790 ### Network Interface Cards
1791
1792 ```
1793 1. 10GE NICs
1794     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1795     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1796     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1797 2. 25GE NICs
1798     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1799 3. 40GE NICs
1800     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1801 4. 100GE NICs
1802     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1803 ```
1804
1805 ### Pluggables and Cables
1806
1807 Pluggables:
1808
1809 ```
1810 1. 10GE SFP+
1811     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1812     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1813 2. 25GE SFP28
1814     - None
1815 3. 40GE QSFP+
1816     - None
1817 4. 100GE
1818     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1819 ```
1820
1821 Standalone cables:
1822
1823 ```
1824 1. 10GE
1825     - None
1826 2. 25GE
1827     - None
1828 3. 40GE QSFP+
1829     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1830 4. 100GE
1831     - None
1832 ```
1833
1834 ### Other Parts