Added amd 2n-zen2 testbed specification
[csit.git] / docs / lab / testbed_specifications.md
1 # FD.io CSIT Testbed Specifications
2
3 1. [Purpose](#purpose)
4 1. [Testbeds Overview](#testbeds-overview)
5    1. [Summary List](#summary-list)
6    1. [1-Node-Skylake Xeon Intel (1n-skx)](#1-node-skylake-xeon-intel-1n-skx)
7    1. [1-Node-ThunderX2 Arm Marvell (1n-tx2)](#1-node-thunderx2-arm-marvell-1n-tx2)
8    1. [1-Node-Cascadelake Xeon Intel (1n-clx)](#1-node-cascadelake-xeon-intel-1n-clx)
9    1. [2-Node-Skylake Xeon Intel (2n-skx)](#2-node-skylake-xeon-intel-2n-skx)
10    1. [2-Node-Denverton Atom Intel (2n-dnv)](#2-node-denverton-atom-intel-2n-dnv)
11    1. [2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)](#2-node-ixiaps1l47-ixia-psone-l47-2n-ps1)
12    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
13    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
14    1. [3-Node-Haswell Xeon Intel (3n-skx)](#3-node-haswell-xeon-intel-3n-skx)
15    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
16    1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
17    1. [3-Node-MACCHIATObin Arm Marvell](#3-node-macchiatobin-arm-marvell)
18    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
19 1. [Server Management](#server-management)
20    1. [Requirements](#requirements)
21    1. [Addressing](#addressing)
22    1. [LOM (IPMI) VLAN IP Addresses](#lom-ipmi-vlan-ip-addresses)
23    1. [Management VLAN IP Addresses](#management-vlan-ip-addresses)
24 1. [Server Specifications](#server-specifications)
25    1. [Server Types](#server-types)
26    1. [Naming Convention](#naming-convention)
27 1. [Testbeds Configuration](#testbeds-configuration)
28    1. [Per Testbed Server Allocation and Naming](#per-testbed-server-allocation-and-naming)
29       1. [1-Node-Skylake Servers (1n-skx) PROD](#1-node-skylake-servers-1n-skx-prod)
30       1. [1-Node-Thunderx2 Servers (1n-tx2) WIP](#1-node-thunderx2-servers-1n-tx2-wip)
31       1. [1-Node-Cascadelake Servers (1n-clx) PROD](#1-node-cascadelake-servers-1n-clx-prod)
32       1. [2-Node-Skylake Servers (2n-skx) PROD](#2-node-skylake-servers-2n-skx-prod)
33       1. [2-Node-Denverton Servers (2n-dnv) TODO](#2-node-denverton-servers-2n-dnv-todo)
34       1. [2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY](#2-node-ixiaps1l47-servers-2n-ps1-verify)
35       1. [2-Node-Cascadelake Servers (2n-clx) SETUP](#2-node-cascadelake-servers-2n-clx-setup)
36       1. [2-Node-Zen2 Servers (2n-zn2) SETUP](#2-node-zen2-servers-2n-zn2-setup])
37       1. [3-Node-Haswell Servers (3n-hsw) PROD](#3-node-haswell-servers-3n-hsw-prod)
38       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
39       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
40       1. [3-Node-Taishan Servers (3n-tsh) WIP](#3-node-taishan-servers-3n-tsh-wip)
41       1. [3-Node-Mcbin Servers (3n-mcb) TODO](#3-node-mcbin-servers-3n-mcb-todo)
42    1. [Per Testbed Wiring](#per-testbed-wiring)
43       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
44       1. [1-Node-Thunderx2 Wiring (1n-tx2) WIP](#1-node-thunderx2-wiring-1n-tx2-wip)
45       1. [1-Node-Cascadelake Wiring (1n-clx) SETUP](#1-node-cascadelake-wiring-1n-clx-setup)
46       1. [2-Node-Skylake Wiring (2n-skx) PROD](#2-node-skylake-wiring-2n-skx-prod)
47       1. [2-Node-Denverton Wiring (2n-dnv) TODO](#2-node-denverton-wiring-2n-dnv-todo)
48       1. [2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY](#2-node-ixiaps1l47-wiring-2n-ps1-verify)
49       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
50       1. [2-Node-Zen2 Wiring (2n-zen2) SETUP](#2-node-zen2-wiring-2n-zen2-setup])
51       1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
52       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
53       1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
54       1. [3-Node-Taishan Wiring (3n-tsh) WIP](#3-node-taishan-wiring-3n-tsh-wip)
55       1. [3-Node-Mcbin Wiring (3n-mcb) WIP](#3-node-mcbin-wiring-3n-mcb-wip)
56 1. [Inventory](#inventory)
57    1. [Appliances](#appliances)
58    1. [Arm Servers](#arm-servers)
59    1. [Xeon and Atom Servers](#xeon-and-atom-servers)
60    1. [Network Interface Cards](#network-interface-cards)
61    1. [Pluggables and Cables](#pluggables-and-cables)
62    1. [Other Parts](#other-parts)
63
64 ## Purpose
65
66 This note includes specification of the physical testbed infrastructure
67 hosted by LFN FD.io CSIT project.
68
69 ## Testbeds Overview
70
71 ### Summary List
72
73 ```
74  #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #mcb #clx #zn2
75  1. 1-Node-VIRL        dev    hsw   ---   3    3    0    3    0    0    0    0    0    0    0    0    0
76  2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0
77  3. 1-Node-Thunderx2   dev    tx2   na    1    1    0    0    0    0    0    0    1    0    0    0    0
78  4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0
79  5. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0    0
80  6. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0
81  7. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0
82  8. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0
83  9. 3-Node-Haswell     perf   hsw   hsw   3    6    3    9    0    0    0    0    0    0    0    0    0
84 10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0
85 11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0
86 12. 3-Node-Taishan     perf   tsh   skx   1    2    1    0    .5   0    0    0    0    2    0    0    0
87 13. 3-Node-Mcbin       perf   mcb   skx   1    2    1    0    .5   0    0    0    0    0    2    0    0
88 14. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0
89 15. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2
90                                  Totals: 22   35   18   12   19    1    2    3    1    2    2    7    2
91 ```
92
93 ### 1-Node-Skylake Xeon Intel (1n-skx)
94
95 Each 1-Node-Skylake testbed includes one SUT (Server-Type-B6) with NIC
96 ports connected back-to-back ([Server Types](#server-types)).
97 Used for FD.io VPP_Device functional driver tests.
98
99 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
100
101 Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) with NIC
102 ports connected back-to-back ([Server Types](#server-types)).
103 Used for FD.io VPP_Device functional driver tests.
104
105 ### 1-Node-Cascadelake Xeon Intel (1n-clx)
106
107 Each 1-Node-Cascadelake testbed includes one SUT (Server-Type-C1) with
108 NIC ports connected back-to-back ([Server Types](#server-types)).
109
110 Used for FD.io VPP_Device functional driver tests.
111
112 ### 2-Node-Skylake Xeon Intel (2n-skx)
113
114 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B1) and one TG
115 (Server-Type-B2) connected in a 2-node circular topology
116 ([Server Types](#server-types)).
117 Used for FD.io performance tests.
118
119 ### 2-Node-Denverton Atom Intel (2n-dnv)
120
121 Each 2-Node-Skylake testbed includes one SUT (Server-Type-B10) and one
122 TG (Server-Type-B2) connected in a 2-node circular topology
123 ([Server Types](#server-types)).
124 Used for FD.io performance tests.
125
126 ### 2-Node-IxiaPS1L47 Ixia PSOne L47 (2n-ps1)
127
128 Each 2-Node-IxiaPS1L47 testbed includes one SUT (Server-Type-B1) and one
129 TG (Ixia PSOne appliance) with 10GE interfaces connected in a 2-node
130 circular topology ([Server Types](#server-types)).
131 Used for FD.io TCP/IP and HTTP performance tests.
132
133 ### 2-Node-Cascadelake Xeon Intel (2n-clx)
134
135 Each 2-Node-Cascadelake testbed includes one SUT (Server-Type-C2) and
136 one TG (Server-Type-C3) connected in a 2-node circular topology
137 ([Server Types](#server-types)).
138 Used for FD.io performance tests.
139
140 ### 2-Node-Zen2 EPYC AMD (2n-zn2)
141
142 Each 2-Node-Zen2 testbed includes one SUT (Server-Type-D1) and
143 one TG (Server-Type-D2) connected in a 2-node circular topology
144 ([Server Types](#server-types)).
145 Used for FD.io performance tests.
146
147 ### 3-Node-Haswell Xeon Intel (3n-hsw)
148
149 Each 3-Node-Haswell testbed includes two SUTs (Server-Type-A1) and one
150 TG (Server-Type-A2) connected in a 3-node circular topology
151 ([Server Types](#server-types)).
152 Used for FD.io performance tests.
153
154 ### 3-Node-Skylake Xeon Intel (3n-skx)
155
156 Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
157 TG (Server-Type-B2) connected in a 3-node circular topology.
158 Used for FD.io performance tests.
159
160 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
161
162 Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
163 TG (Server-Type-B2) connected in a 3-node circular topology
164 ([Server Types](#server-types)).
165 Used for FD.io performance tests.
166
167 ### 3-Node-MACCHIATObin Arm Marvell
168
169 Each 3-Node-MACCHIATObin testbed includes two SUTs (Server-Type-B4) and
170 one TG (Server-Type-B2) connected in a 3-node circular topology
171 ([Server Types](#server-types)).
172 Used for FD.io performance tests.
173
174 ### 3-Node-Rangeley Atom Testbeds
175
176 Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
177 TG (Server-Type-2) connected in a 3-node circular topology
178 ([Server Types](#server-types)).
179 Used for FD.io performance tests.
180
181 ## Server Management
182
183 ### Requirements
184
185 For management purposes, each server must have following two ports
186 connected to the management network:
187
188 ```
189 - 1GE IPMI port
190   - IPMI - Intelligent Platform Management Interface.
191   - Required for access to embedded server management with WebUI, CLI,
192     SNMPv3, IPMIv2.0, for firmware (BIOS) and OS updates.
193 - 1GE/10GE/40GE management port
194   - hostOS management port for general system management.
195 ```
196
197 ### Addressing
198
199 Each server has a LOM (Lights-Out-Management e.g. SM IPMI) and a
200 Management port, which are connected to two different VLANs.
201
202 ```
203 1. LOM (IPMI) VLAN:
204     - Subnet: 10.30.50.0/24
205     - Gateway: 10.30.50.1
206     - Broadcast: 10.30.50.255
207     - DNS1: 199.204.44.24
208     - DNS2: 199.204.47.54
209 2. Management Vlan:
210     - Subnet: 10.30.51.0/24
211     - Gateway: 10.30.51.1
212     - Broadcast: 10.30.51.255
213     - DNS1: 199.204.44.24
214     - DNS2: 199.204.47.54
215 ```
216
217 To access these hosts, VPN connection is required.
218
219 ### LOM (IPMI) VLAN IP Addresses
220
221 Name         | Comment
222 ------------ | -------
223 10.30.50.0   | network
224 10.30.51.1   | Router
225 10.30.50.2   | LF Reserved
226 10.30.50.3   | LF Reserved
227 10.30.50.4   | LF Reserved
228 10.30.50.5   | LF Reserved
229 10.30.50.6   | LF Reserved
230 10.30.50.7   | LF Reserved
231 10.30.50.8   | LF Reserved
232 10.30.50.9   | LF Reserved
233 10.30.50.10  | LF Reserved
234 10.30.50.11  | LF Reserved
235 10.30.50.12  | LF Reserved
236 10.30.50.13  | LF Reserved
237 10.30.50.14  | LF Reserved
238 10.30.50.15  | LF Reserved
239 10.30.50.16  | t1-tg1
240 10.30.50.17  | t1-sut1
241 10.30.50.18  | t1-sut2
242 10.30.50.20  | t2-tg1
243 10.30.50.21  | t2-sut1
244 10.30.50.22  | t2-sut2
245 10.30.50.24  | t3-tg1
246 10.30.50.25  | t3-sut1
247 10.30.50.26  | t3-sut-2
248 10.30.50.28  | s41-nomad
249 10.30.50.29  | s39-nomad
250 10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
251 10.30.50.30  | s40-nomad
252 10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
253 10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
254 10.30.50.32  | s42-nomad (formerly nomad1)
255 10.30.50.33  | s43-nomad (formerly nomad2)
256 10.30.50.34  | s44-nomad (formerly nomad3)
257 10.30.50.35  | s45-nomad (formerly nomad4)
258 10.30.50.36  | s17-t33-sut1
259 10.30.50.37  | s18-t33-sut2
260 10.30.50.38  | fdio-marvell-dev
261 10.30.50.39  | s53-nomad
262 10.30.50.40  | s54-nomad
263 10.30.50.41  | s3-t21-sut1
264 10.30.50.42  | s4-t21-tg1
265 10.30.50.43  | s11-t31-sut1
266 10.30.50.44  | s12-t31-sut2
267 10.30.50.45  | s13-t31-tg1
268 10.30.50.46  | s19-t33t34-tg1
269 10.30.50.47  | s1-t11-sut1
270 10.30.50.48  | s2-t12-sut1
271 10.30.50.49  | s5-t22-sut1
272 10.30.50.50  | s6-t22-tg1
273 10.30.50.51  | s7-t23-sut1
274 10.30.50.52  | s8-t23-tg1
275 10.30.50.53  | s9-t24-sut1
276 10.30.50.54  | s10-t24-tg1
277 10.30.50.55  | s14-t32-sut1
278 10.30.50.56  | s15-t32-sut2
279 10.30.50.57  | s16-t32-tg1
280 10.30.50.58  | s25-t25-sut1
281 10.30.50.59  | s26-t25-tg1
282 10.30.50.65  | s52-nomad
283 10.30.50.66  | s51-nomad (out of order)
284 10.30.50.67  | s49-nomad
285 10.30.50.68  | s50-nomad (out of order)
286 10.30.50.69  | s27-t13-sut
287 10.30.50.255 | Broadcast
288 n/a          | s20-t34-sut1
289 n/a          | s21-t34-sut2
290 10.30.55.0   | network
291 10.30.55.1   | Router
292 10.30.55.10  | s28-t26t35-tg1
293 10.30.55.11  | s29-t26-sut1
294 10.30.55.12  | s30-t35-sut1
295 10.30.55.13  | s31-t35-sut2
296 10.30.55.14  | s46-nomad (formerly server-type-c4-1)
297 10.30.55.15  | s47-nomad (formerly server-type-c4-2)
298 10.30.55.16  | s48-nomad (formerly server-type-c4-3)
299 10.30.55.17  | s32-t14-sut1
300 10.30.55.18  | s33-t27-sut1
301 10.30.55.19  | s34-t27-tg1
302 10.30.55.20  | s35-t28-sut1
303 10.30.55.21  | s36-t28-tg1
304 10.30.55.22  | s37-t29-sut1
305 10.30.55.23  | s38-t29-tg1
306 10.30.55.24  | s60-t210-sut1
307 10.30.55.25  | s61-t210-tg1
308 10.30.55.255 | Broadcast
309
310 ### Management VLAN IP Addresses
311
312 Name                      | Comment
313 ------------------------- | -------
314 10.30.51.0                | network
315 10.30.51.1                | Router
316 10.30.51.2                | LF Reserved
317 10.30.51.3                | LF Reserved
318 10.30.51.4                | LF Reserved
319 10.30.51.5                | LF Reserved
320 10.30.51.6                | LF Reserved
321 10.30.51.7                | LF Reserved
322 10.30.51.8                | LF Reserved
323 10.30.51.9                | s22-t35-sut1 (netgate-1)
324 10.30.51.10               | s23-t35-sut2 (netgate-2)
325 10.30.51.11               | s24-t35-sut3 (netgate-3)
326 10.30.51.12               | softiron-1
327 10.30.51.13               | softiron-2
328 10.30.51.14               | softiron-3
329 10.30.51.15               | LF Reserved
330 10.30.51.16               | t1-tg1
331 10.30.51.17               | t1-sut1
332 10.30.51.18               | t1-sut2
333 10.30.51.20               | t2-tg1
334 10.30.51.21               | t2-sut1
335 10.30.51.22               | t2-sut2
336 10.30.51.24               | t3-tg1
337 10.30.51.25               | t3-sut1
338 10.30.51.26               | t3-sut-2
339 10.30.51.28               | s41-nomad
340 10.30.51.29               | s39-nomad
341 10.30.51.30               | s40-nomad
342 10.30.51.32               | s42-nomad (formerly nomad1)
343 10.30.51.33               | s43-nomad (formerly nomad2)
344 10.30.51.34               | s44-nomad (formerly nomad3)
345 10.30.51.35               | s45-nomad (formerly nomad4)
346 10.30.51.36               | s17-t33-sut1
347 10.30.51.37               | s18-t33-sut2
348 10.30.51.38               | fdio-marvell-dev
349 10.30.51.39               | s53-nomad
350 10.30.51.40               | s54-nomad
351 10.30.51.41               | s20-t34-sut1
352 10.30.51.42               | s21-t34-sut2
353 10.30.51.44               | s3-t21-sut1
354 10.30.51.45               | s4-t21-tg1
355 10.30.51.46               | s11-t31-sut1
356 10.30.51.47               | s12-t31-sut2
357 10.30.51.48               | s13-t31-tg1
358 10.30.51.49               | s19-t33t34-tg1
359 10.30.51.50               | s1-t11-sut1
360 10.30.51.51               | s2-t12-sut1
361 10.30.51.52               | s5-t22-sut1
362 10.30.51.53               | s6-t22-tg1
363 10.30.51.54               | s7-t23-sut1
364 10.30.51.55               | s8-t23-tg1
365 10.30.51.56               | s9-t24-sut1
366 10.30.51.57               | s10-t24-tg1
367 10.30.51.58               | s14-t32-sut1
368 10.30.51.59               | s15-t32-sut2
369 10.30.51.60               | s16-t32-tg1
370 10.30.51.61               | s25-t25-sut1
371 10.30.51.62               | s26-t25-tg1
372 10.30.51.65               | s52-nomad
373 10.30.51.66               | s51-nomad
374 10.30.51.67               | s49-nomad
375 10.30.51.68               | s50-nomad
376 10.30.51.69               | s27-t13-sut1
377 10.30.51.70-10.30.51.105  | FREE
378 10.30.51.106-10.30.51.180 | FREE
379 10.30.51.181-10.30.51.254 | FREE
380 10.30.51.255              | Broadcast
381 10.32.8.0                 | network
382 10.32.8.1                 | Router
383 10.32.8.10                | s28-t26t35-tg1
384 10.32.8.11                | s29-t26-sut1
385 10.32.8.12                | s30-t35-sut1
386 10.32.8.13                | s31-t35-sut2
387 10.32.8.14                | s46-nomad (formerly server-type-c4-1)
388 10.32.8.15                | s47-nomad (formerly server-type-c4-2)
389 10.32.8.16                | s48-nomad (formerly server-type-c4-3)
390 10.32.8.17                | s32-t14-sut1
391 10.32.8.18                | s33-t27-sut1
392 10.32.8.19                | s34-t27-tg1
393 10.32.8.20                | s35-t28-sut1
394 10.32.8.21                | s36-t28-tg1
395 10.32.8.22                | s37-t29-sut1
396 10.32.8.23                | s38-t29-tg1
397 10.32.8.24                | s60-t210-sut1
398 10.32.8.25                | s61-t210-tg1
399 10.32.8.255               | Broadcast
400
401 ## Server Specifications
402
403 ### Server Types
404
405 FD.io CSIT lab contains following server types:
406 ```
407 1. Server-Type-A1: Purpose - Haswell Xeon SUT (Systems Under Test) for FD.io performance testing.
408     - Quantity: 6 servers.
409     - Physical connectivity:
410         - CIMC and host management ports.
411         - NIC ports connected in 3-node topologies.
412     - Main HW configuration:
413         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
414         - Processors: 2* E5-2699v3 2.3 GHz.
415         - RAM Memory: 16* 32GB DDR4-2133MHz.
416         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
417     - NICs configuration:
418         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 PCIe3.0 lanes)
419             - PCIe Slot1: Cisco VIC 1385 2p40GE.
420             - PCIe Slot2: Intel NIC x520 2p10GE.
421             - PCIe Slot3: empty.
422         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 PCIe3.0 lanes)
423             - PCIe Slot4: Intel NIC xl710 2p40GE.
424             - PCIe Slot5: Intel NIC x710 2p10GE.
425             - PCIe Slot6: Intel QAT 8950 50G (Walnut Hill)
426         - MLOM slot: Cisco VIC 1227 2p10GE (x8 PCIe2.0 lanes).
427 2. Server-Type-A2: Purpose - Haswell Xeon TG (Traffic Generators) for FD.io performance testing.
428     - Quantity: 3 servers.
429     - Physical connectivity:
430         - CIMC and host management ports.
431         - NIC ports connected in 3-node topologies.
432     - Main HW configuration:
433         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
434         - Processors: 2* E5-2699v3 2.3 GHz.
435         - RAM Memory: 16* 32GB DDR4-2133MHz.
436         - Disks: 2* 2TB 12G SAS 7.2K RPM SFF HDD.
437     - NICs configuration:
438         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
439             - PCIe Slot1: Intel NIC xl710 2p40GE.
440             - PCIe Slot2: Intel NIC x710 2p10GE.
441             - PCIe Slot3: Intel NIC x710 2p10GE.
442         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
443             - PCIe Slot4: Intel NIC xl710 2p40GE.
444             - PCIe Slot5: Intel NIC x710 2p10GE.
445             - PCIe Slot6: Intel NIC x710 2p10GE.
446         - MLOM slot: empty.
447 3. Server-Type-A3: Purpose - Haswell Xeon VIRL hosts for FD.io functional testing.
448     - Quantity: 3 servers.
449     - Physical connectivity:
450         - CIMC and host management ports.
451         - no NIC ports, standalone setup.
452     - Main HW configuration:
453         - Chassis: UCSC-C240-M4SX with 6 PCIe3.0 slots.
454         - Processors: 2* E5-2699v3 2.3 GHz.
455         - RAM Memory: 16* 32GB DDR4-2133MHz.
456         - Disks: 2* 480 GB 2.5inch 6G SATA SSD.
457     - NICs configuration:
458         - Numa0: Right PCIe Riser Board (Riser 1) (x8, x8, x8 lanes)
459             - no cards.
460         - Numa1: Left PCIe Riser Board (Riser 2) (x8, x16, x8 lanes)
461             - no cards.
462         - MLOM slot: empty.
463 4. Server-Type-B1: Purpose - Skylake Xeon SUT for FD.io performance testing.
464     - Quantity: ---
465     - Physical connectivity:
466         - IPMI and host management ports.
467         - NIC ports connected into 2-node and 3-node topologies.
468     - Main HW configuration:
469         - Chassis: SuperMicro SYS-7049GP-TRT.
470         - Motherboard: SuperMicro X11DPG-QT.
471         - Processors: 2* Intel Platinum 8180 2.5 GHz.
472         - RAM Memory: 16* 16GB DDR4-2666MHz.
473         - Disks: 2* 1.6TB 6G SATA SSD.
474     - NICs configuration:
475         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
476             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
477             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
478             - PCIe Slot9 5e:00.xx: empty.
479         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
480             - PCIe Slot6 86:00.xx: empty.
481             - PCIe Slot8 af:00.xx: empty.
482             - PCIe Slot10 d8:00.xx: empty.
483 5. Server-Type-B2: Purpose - Skylake Xeon TG for FD.io performance testing.
484     - Quantity: ---
485     - Physical connectivity:
486         - IPMI and host management ports.
487         - NIC ports connected into 2-node and 3-node topologies.
488     - Main HW configuration:
489         - Chassis: SuperMicro SYS-7049GP-TRT.
490         - Motherboard: SuperMicro X11DPG-QT.
491         - Processors: 2* Intel Platinum 8180 2.5 GHz.
492         - RAM Memory: 16* 16GB DDR4-2666MHz.
493         - Disks: 2* 1.6TB 6G SATA SSD.
494     - NICs configuration:
495         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
496             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
497             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
498             - PCIe Slot9 5e:00.xx: empty.
499         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
500             - PCIe Slot6 86:00.xx: empty.
501             - PCIe Slot8 af:00.xx: empty.
502             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
503 6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
504     - Quantity: 2
505     - Physical connectivity:
506         - IPMI(?) and host management ports.
507         - NIC ports connected into 3-node topology.
508     - Main HW configuration:
509         - Chassis: Huawei TaiShan 2280.
510         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72
511         - RAM Memory: 8* 16GB DDR4-2400MT/s
512         - Disks: 1* 4TB SATA HDD
513     - NICs configuration:
514         - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
515         - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
516 7. Server-Type-B4: Purpose - MACCHIATObin Arm Marvell SUT for FD.io performance testing.
517     - Quantity: 3
518     - Physical connectivity:
519         - Host management ports.
520         - NIC ports connected into 2-node and 3-node topologies.
521     - Main HW configuration:
522         - Chassis: MACCHIATObin.
523         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72
524         - RAM Memory: 1* 16GB DDR4
525         - Disks: 1* 128GB(?) SATA SDD
526     - NICs configuration:
527         - pp2-2p10GE Marvell (on-chip Ethernet ports ; marvell plugin in VPP)
528 8. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
529     - Quantity: TBD based on testbed allocation.
530     - Physical connectivity:
531         - Management: serial Port (usb) for console
532         - NIC ports connected into 2-node.
533     - Main HW configuration:
534         - Chassis: Netgate XG-2758-1u
535         - Processors: 1* Rangeley (Atom) C2758 2.4 GHz
536         - RAM Memory: 16GB ECC
537         - Disks: 150 GB
538     - NICs configuration:
539         - 2x 10Gb Intel 82599ES
540         - 4x 1GB Intel I354
541 9. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
542     - Quantity: 2.
543     - Physical connectivity:
544         - IPMI and host management ports.
545         - NIC ports connected into 2-node and 3-node topologies.
546     - Main HW configuration:
547         - Chassis: SuperMicro SYS-7049GP-TRT.
548         - Motherboard: SuperMicro X11DPG-QT.
549         - Processors: 2* Intel Platinum 8180 2.5 GHz.
550         - RAM Memory: 16* 16GB DDR4-2666MHz.
551         - Disks: 2* 1.6TB 6G SATA SSD.
552     - NICs configuration:
553         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
554             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
555             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
556             - PCIe Slot9 5e:00.xx: empty.
557         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
558             - PCIe Slot6 86:00.xx: empty.
559             - PCIe Slot8 af:00.xx: empty.
560             - PCIe Slot10 d8:00.xx: empty.
561 10. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
562     - Quantity: 1.
563     - Physical connectivity:
564         - Host management interface: 10/100/1000-BaseT.
565         - 8-port 10GE SFP+ integrated NIC.
566     - Main HW configuration:
567         - Chassis: PS10GE4NG.
568         - Motherboard: SuperMicro X11DPG-QT.
569         - Processors: Quad-Core, Intel Processor.
570         - HW accelerators: FPGA offload.
571         - RAM Memory: 64GB.
572         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
573         - Physical Interfaces: 4 * 10GE SFP+.
574         - Operating System: Native IxOS.
575     - Interface configuration:
576         - Port-1: 10GE SFP+.
577         - Port-2: 10GE SFP+.
578         - Port-3: 10GE SFP+.
579         - Port-4: 10GE SFP+.
580 11. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
581     - Quantity: 1.
582     - Physical connectivity:
583         - IPMI and host management ports.
584         - NIC ports.
585     - Main HW configuration:
586         - Chassis: SuperMicro SYS-7049GP-TRT.
587         - Motherboard: SuperMicro X11DPG-QT.
588         - Processors: 2* Intel Platinum 8180 2.5 GHz.
589         - RAM Memory: 16* 16GB DDR4-2666MHz.
590         - Disks: 2* 1.6TB 6G SATA SSD.
591     - NICs configuration:
592         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
593             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
594             - PCIe Slot4 3b:00.xx: empty.
595             - PCIe Slot9 5e:00.xx: empty.
596         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
597             - PCIe Slot6 86:00.xx: empty.
598             - PCIe Slot8 af:00.xx: empty.
599             - PCIe Slot10 d8:00.xx: empty.
600 12. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
601     - Quantity: 1
602     - Physical connectivity:
603         - IPMI and host management ports.
604         - NIC ports connected into 1-node topologies.
605     - Main HW configuration:
606         - Chassis: Gigabyte R181-T90 1U
607         - Motheboard: MT91-FS1
608         - Processors: 1* ThunderX2 ARMv8 CN9975 2.0 GHz
609         - RAM Memory: 4* 32GB RDIMM
610         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
611     - NICs configuration:
612         - Numa0:
613             - PCIe Slot1 05:00.xx: XL710-QDA2.
614             - PCIe Slot3 08:00.xx: XL710-QDA2.
615         - Numa1:
616             - PCIe Slot6 85:00.xx: XL710-QDA2.
617 13. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
618     - Quantity: 4
619     - Physical connectivity:
620         - IPMI and host management ports.
621         - NIC ports.
622     - Main HW configuration:
623         - Chassis: SuperMicro SYS-E300-9A
624         - Processors: 1* Intel(R) Atom(TM) CPU C3858 @ 2.00GHz
625         - RAM Memory: 32GB ECC
626         - Disks: 480 GB
627     - NICs configuration:
628         - 2x 10Gb Intel x553 fiber ports
629         - 2x 10Gb Intel x553 copper ports
630         - 4x 1GB Intel I350 ports
631 14. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
632     - Quantity: 1.
633     - Physical connectivity:
634         - IPMI and host management ports.
635         - NIC ports connected into 1-node testbed topologies.
636     - Main HW configuration:
637         - Chassis: SuperMicro SYS-7049GP-TRT.
638         - Motherboard: SuperMicro X11DPG-QT.
639         - Processors: 2* Intel Platinum 8280 2.7 GHz.
640         - RAM Memory: 12* 16GB DDR4-2933.
641         - Disks: 2* 1.92TB SATA SSD.
642     - NICs configuration:
643         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
644             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
645             - PCIe Slot4 3b:00.xx: x710-4p10GE Intel.
646             - PCIe Slot9 5e:00.xx: empty.
647         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
648             - PCIe Slot6 86:00.xx: empty.
649             - PCIe Slot8 af:00.xx: empty.
650             - PCIe Slot10 d8:00.xx: empty.
651 15. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
652     - Quantity: 3
653     - Physical connectivity:
654         - IPMI and host management ports.
655         - NIC ports connected into 2-node testbed topologies.
656     - Main HW configuration:
657         - Chassis: SuperMicro SYS-7049GP-TRT.
658         - Motherboard: SuperMicro X11DPG-QT.
659         - Processors: 2* Intel Gold 6252N 2.3 GHz.
660         - RAM Memory: 12* 16GB DDR4-2933.
661         - Disks: 2* 1.92TB SATA SSD.
662     - NICs configuration:
663         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
664             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
665             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
666             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
667         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
668             - PCIe Slot6 86:00.xx: empty.
669             - PCIe Slot8 af:00.xx: empty.
670             - PCIe Slot10 d8:00.xx: empty.
671 16. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
672     - Quantity: 3.
673     - Physical connectivity:
674         - IPMI and host management ports.
675         - NIC ports connected into 2-node testbed topologies.
676     - Main HW configuration:
677         - Chassis: SuperMicro SYS-7049GP-TRT.
678         - Motherboard: SuperMicro X11DPG-QT.
679         - Processors: 2* Intel Platinum 8280 2.7 GHz.
680         - RAM Memory: 12* 16GB DDR4-2933.
681         - Disks: 2* 1.92TB SATA SSD.
682     - NICs configuration:
683         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
684             - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
685             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
686             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
687         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
688             - PCIe Slot6 86:00.xx: empty.
689             - PCIe Slot8 af:00.xx: empty.
690             - PCIe Slot10 d8:00.xx: empty.
691 17. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
692     - Quantity: 3.
693     - Physical connectivity:
694         - CIMC and host management ports.
695         - no NIC ports, standalone setup.
696     - Main HW configuration:
697         - Chassis: SuperMicro 1029P-WTRT.
698         - Motherboard: SuperMicro X11DDW-NT.
699         - Processors: 2* Intel Platinum 8280 2.7 GHz.
700         - RAM Memory: 12* 16GB DDR4-2933.
701         - Disks: 4* 1.92TB SATA SSD.
702     - NICs configuration:
703         - Numa0:
704             - no cards.
705         - Numa1:
706             - no cards.
707 15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
708     - Quantity: 1.
709     - Physical connectivity:
710         - IPMI and host management ports.
711         - NIC ports connected into 2-node testbed topologies.
712     - Main HW configuration:
713         - Chassis: SuperMicro AS-1114S-WTRT
714         - Processors: 1* AMD EPYC 7532 2.4 GHz.
715         - RAM Memory: 8* 32GB DDR4-2933.
716         - Disks: 1* 1TB SATA SSD.
717     - NICs configuration:
718         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
719             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
720             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
721             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
722 16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
723     - Quantity: 1.
724     - Physical connectivity:
725         - IPMI and host management ports.
726         - NIC ports connected into 2-node testbed topologies.
727     - Main HW configuration:
728         - Chassis: SuperMicro AS-1114S-WTRT
729         - Processors: 1* AMD EPYC 7532 2.4 GHz.
730         - RAM Memory: 8* 32GB DDR4-2933.
731         - Disks: 1* 1TB SATA SSD.
732     - NICs configuration:
733         - Numa0: (x16, x16, x16 PCIe3.0 lanes)
734             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
735             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
736             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
737 ```
738
739 ### Naming Convention
740
741 Following naming convention is used within this page to specify physical
742 connectivity and wiring across defined CSIT testbeds:
743
744 ```
745 - testbedname: testbedN.
746 - hostname:
747     - traffic-generator: tN-tgW.
748     - system-under-testX: tN-sutX.
749 - portnames:
750     - tN-tgW-cY/pZ.
751     - tN-sutX-cY/pZ.
752 - where:
753     - N - testbed number.
754     - tgW - server acts as traffic-generator with W index.
755     - sutX - server acts as system-under-test with X index.
756     - Y - PCIe slot number denoting a NIC card number within the host.
757     - Z - port number on the NIC card.
758 ```
759
760 ## Testbeds Configuration
761
762 ### Per Testbed Server Allocation and Naming
763
764 #### 1-Node-Skylake Servers (1n-skx) PROD
765
766 ```
767 - SUT [Server-Type-B6]:
768     - testbedname: testbed11.
769     - hostname: s1-t11-sut1.
770     - IPMI IP: 10.30.50.47
771     - Host IP: 10.30.51.50
772     - portnames:
773         - s1-t11-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
774         - s1-t11-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
775         - s1-t11-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
776         - s1-t11-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
777         - s1-t11-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
778         - s1-t11-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
779         - s1-t11-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
780         - s1-t11-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
781 - SUT [Server-Type-B6]:
782     - testbedname: testbed12.
783     - hostname: s2-t12-sut1.
784     - IPMI IP: 10.30.50.48
785     - Host IP: 10.30.51.51
786     - portnames:
787         - s2-t12-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
788         - s2-t12-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
789         - s2-t12-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
790         - s2-t12-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
791         - s2-t12-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
792         - s2-t12-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
793         - s2-t12-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
794         - s2-t12-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
795 ```
796
797 #### 1-Node-Thunderx2 Servers (1n-tx2) WIP
798
799 ```
800 - SUT [Server-Type-B9]:
801     - testbedname: testbed13.
802     - hostname: s27-t13-sut1.
803     - IPMI IP: 10.30.50.69
804     - Host IP: 10.30.51.69
805     - portnames:
806         - s27-t13-sut1-c1/p1 - 40GE-port1 XL710-QDA2-2p40GE.
807         - s27-t13-sut1-c1/p2 - 40GE-port2 XL710-QDA2-2p40GE.
808         - s27-t13-sut1-c3/p1 - 40GE-port1 XL710-QDA2-2p40GE.
809         - s27-t13-sut1-c3/p2 - 40GE-port2 XL710-QDA2-2p40GE.
810         - s27-t13-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
811         - s27-t13-sut1-c6/p2 - 40GE-port2 XL710-QDA2-2p40GE.
812 ```
813
814 #### 1-Node-Cascadelake Servers (1n-clx) PROD
815
816 ```
817 - SUT [Server-Type-C1]:
818     - testbedname: testbed11.
819     - hostname: s32-t14-sut1.
820     - IPMI IP: 10.30.55.17
821     - Host IP: 10.32.8.17
822     - portnames:
823         - s32-t14-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
824         - s32-t14-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
825         - s32-t14-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
826         - s32-t14-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
827         - s32-t14-sut1-c4/p1 - 10GE-port1 x710-4p10GE.
828         - s32-t14-sut1-c4/p2 - 10GE-port2 x710-4p10GE.
829         - s32-t14-sut1-c4/p3 - 10GE-port3 x710-4p10GE.
830         - s32-t14-sut1-c4/p4 - 10GE-port4 x710-4p10GE.
831 ```
832
833 #### 2-Node-Skylake Servers (2n-skx) PROD
834
835 ```
836 - SUT [Server-Type-B1]:
837     - testbedname: testbed21.
838     - hostname: s3-t21-sut1.
839     - IPMI IP: 10.30.50.41
840     - Host IP: 10.30.51.44
841     - portnames:
842         - s3-t21-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
843         - s3-t21-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
844         - s3-t21-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
845         - s3-t21-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
846         - s3-t21-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
847         - s3-t21-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
848 - TG [Server-Type-B2]:
849     - testbedname: testbed21.
850     - hostname: s4-t21-tg1.
851     - IPMI IP: 10.30.50.42
852     - Host IP: 10.30.51.45
853     - portnames:
854         - s4-t21-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
855         - s4-t21-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
856         - s4-t21-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
857         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
858         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
859         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
860 - SUT [Server-Type-B1]:
861     - testbedname: testbed22.
862     - hostname: s5-t22-sut1.
863     - IPMI IP: 10.30.50.49
864     - Host IP: 10.30.51.52
865     - portnames:
866         - s5-t22-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
867         - s5-t22-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
868         - s5-t22-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
869         - s5-t22-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
870         - s5-t22-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
871         - s5-t22-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
872 - TG [Server-Type-B2]:
873     - testbedname: testbed22.
874     - hostname: s6-t22-tg1.
875     - IPMI IP: 10.30.50.50
876     - Host IP: 10.30.51.53
877     - portnames:
878         - s6-t22-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
879         - s6-t22-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
880         - s6-t22-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
881         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
882         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
883         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
884 - SUT [Server-Type-B1]:
885     - testbedname: testbed23.
886     - hostname: s7-t23-sut1.
887     - IPMI IP: 10.30.50.51
888     - Host IP: 10.30.51.54
889     - portnames:
890         - s7-t23-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
891         - s7-t23-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
892         - s7-t23-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
893         - s7-t23-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
894         - s7-t23-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
895         - s7-t23-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
896 - TG [Server-Type-B2]:
897     - testbedname: testbed23.
898     - hostname: s8-t23-tg1.
899     - IPMI IP: 10.30.50.52
900     - Host IP: 10.30.51.55
901     - portnames:
902         - s8-t23-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
903         - s8-t23-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
904         - s8-t23-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
905         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
906         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
907         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
908 - SUT [Server-Type-B1]:
909     - testbedname: testbed24.
910     - hostname: s9-t24-sut1.
911     - IPMI IP: 10.30.50.53
912     - Host IP: 10.30.51.56
913     - portnames:
914         - s9-t24-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
915         - s9-t24-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
916         - s9-t24-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
917         - s9-t24-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
918         - s9-t24-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
919         - s9-t24-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
920 - TG [Server-Type-B2]:
921     - testbedname: testbed24.
922     - hostname: s10-t24-tg1.
923     - IPMI IP: 10.30.50.54
924     - Host IP: 10.30.51.57
925     - portnames:
926         - s10-t24-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
927         - s10-t24-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
928         - s10-t24-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
929         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
930         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
931         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
932 ```
933
934 #### 2-Node-Denverton Servers (2n-dnv) WIP
935
936 Note: ServerB28 (TG) is shared between testbed26 & testbed35
937
938 ```
939 - TG [Server-Type-B2]:
940     - testbednames: testbed26 and testbed35.
941     - hostname: s28-t26t35-tg1.
942     - IPMI IP: 10.30.55.10
943     - Host IP: 10.32.8.10
944     - portnames:
945         - s28-t26t35-tg1-c2/p1 - 10GE-port1 x710da2-2p10GE.
946         - s28-t26t35-tg1-c2/p2 - 10GE-port2 x710da2-2p10GE.
947         - s28-t26t35-tg1-c4/p1 - 10GE-port1 x550t2-2p10GE.
948         - s28-t26t35-tg1-c4/p2 - 10GE-port2 x550t2-2p10GE.
949         - s28-t26t35-tg1-c9/p1 - 10GE-port1 x550t2-2p10GE.
950         - s28-t26t35-tg1-c9/p2 - 10GE-port2 x550t2-2p10GE.
951         - s28-t26t35-tg1-c6/p1 - 10GE-port1 x710da2-2p10GE.
952         - s28-t26t35-tg1-c6/p2 - 10GE-port2 x710da2-2p10GE.
953         - s28-t26t35-tg1-c8/p1 - 10GE-port1 x550t2-2p10GE.
954         - s28-t26t35-tg1-c8/p2 - 10GE-port2 x550t2-2p10GE.
955         - s28-t26t35-tg1-c10/p1 - 10GE-port1 x550t2-2p10GE.
956         - s28-t26t35-tg1-c10/p2 - 10GE-port2 x550t2-2p10GE.
957 - SUT [Server-Type-B10]:
958     - testbednames: testbed26.
959     - hostname: s29-t26-sut1.
960     - IPMI IP: 10.30.55.11
961     - Host IP: 10.32.8.11
962     - portnames:
963         - s29-t26-sut1-p1 - 10GE-port1 x553 copper port.
964         - s29-t26-sut1-p2 - 10GE-port2 x553 copper port.
965         - s29-t26-sut1-p3 - 10GE-port3 x553 fiber port.
966         - s29-t26-sut1-p4 - 10GE-port4 x553 fiber port.
967 ```
968
969 #### 2-Node-IxiaPS1L47 Servers (2n-ps1) VERIFY
970
971 ```
972 - SUT [Server-Type-B8]:
973     - testbedname: testbed25.
974     - hostname: s25-t25-sut1.
975     - IPMI IP: 10.30.50.58
976     - Host IP: 10.30.51.61
977     - portnames:
978         - s25-t25-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
979         - s25-t25-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
980         - s25-t25-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
981         - s25-t25-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
982 - TG [Server-Type-B7]:
983     - testbedname: testbed25.
984     - hostname: s26-t25-tg1.
985     - IPMI IP: 10.30.50.59
986     - Host IP: 10.30.51.62
987     - portnames:
988         - s26-t25-tg1-p1 - 10GE-port1.
989         - s26-t25-tg1-p2 - 10GE-port2.
990         - s26-t25-tg1-p3 - 10GE-port3.
991         - s26-t25-tg1-p4 - 10GE-port4.
992 ```
993
994 #### 2-Node-Cascadelake Servers (2n-clx) SETUP
995
996 ```
997 - SUT [Server-Type-C2]:
998     - testbedname: testbed27.
999     - hostname: s33-t27-sut1.
1000     - IPMI IP: 10.30.55.18
1001     - Host IP: 10.32.8.18
1002     - portnames:
1003         - s33-t27-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1004         - s33-t27-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1005         - s33-t27-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1006         - s33-t27-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1007         - s33-t27-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1008         - s33-t27-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1009         - s33-t27-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1010         - s33-t27-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1011 - TG [Server-Type-C3]:
1012     - testbedname: testbed27.
1013     - hostname: s34-t27-tg1.
1014     - IPMI IP: 10.30.55.19
1015     - Host IP: 10.32.8.19
1016     - portnames:
1017         - s34-t27-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1018         - s34-t27-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1019         - s34-t27-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1020         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1021         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1022         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1023         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1024         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1025 - SUT [Server-Type-C2]:
1026     - testbedname: testbed28.
1027     - hostname: s35-t28-sut1.
1028     - IPMI IP: 10.30.55.20
1029     - Host IP: 10.32.8.20
1030     - portnames:
1031         - s35-t28-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1032         - s35-t28-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1033         - s35-t28-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1034         - s35-t28-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1035         - s35-t28-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1036         - s35-t28-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1037         - s35-t28-sut1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1038         - s35-t28-sut1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1039 - TG [Server-Type-C3]:
1040     - testbedname: testbed28.
1041     - hostname: s36-t28-tg1.
1042     - IPMI IP: 10.30.55.21
1043     - Host IP: 10.32.8.21
1044     - portnames:
1045         - s36-t28-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1046         - s36-t28-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1047         - s36-t28-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1048         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1049         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1050         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1051         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
1052         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
1053 - SUT [Server-Type-C2]:
1054     - testbedname: testbed29.
1055     - hostname: s37-t29-sut1.
1056     - IPMI IP: 10.30.55.22
1057     - Host IP: 10.32.8.22
1058     - portnames:
1059         - s37-t29-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1060         - s37-t29-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1061         - s37-t29-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1062         - s37-t29-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1063         - s37-t29-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1064         - s37-t29-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1065         - s37-t29-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1066         - s37-t29-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1067 - TG [Server-Type-C3]:
1068     - testbedname: testbed29.
1069     - hostname: s38-t29-tg1.
1070     - IPMI IP: 10.30.55.23
1071     - Host IP: 10.32.8.23
1072     - portnames:
1073         - s38-t29-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1074         - s38-t29-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1075         - s38-t29-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1076         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1077         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1078         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1079         - s38-t29-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1080         - s38-t29-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1081 ```
1082
1083 #### 2-Node-Zen2 Servers (2n-zn2) SETUP
1084
1085 ```
1086 - SUT [Server-Type-D1]:
1087     - testbedname: testbed210.
1088     - hostname: s60-t210-sut1.
1089     - IPMI IP: 10.30.55.24
1090     - Host IP: 10.32.8.24
1091     - portnames:
1092         - s60-t210-sut1-c1/p1 - 10GE-port1 x710-4p10GE.
1093         - s60-t210-sut1-c1/p2 - 10GE-port2 x710-4p10GE.
1094         - s60-t210-sut1-c1/p3 - 10GE-port3 x710-4p10GE.
1095         - s60-t210-sut1-c1/p4 - 10GE-port4 x710-4p10GE.
1096         - s60-t210-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1097         - s60-t210-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1098         - s60-t210-sut1-c3/p1 - 100GE-port1 ConnectX5-2p100GE.
1099         - s60-t210-sut1-c3/p2 - 100GE-port2 ConnectX5-2p100GE.
1100 - TG [Server-Type-D2]:
1101     - testbedname: testbed210.
1102     - hostname: s61-t210-tg1.
1103     - IPMI IP: 10.30.55.25
1104     - Host IP: 10.32.8.25
1105     - portnames:
1106         - s61-t210-tg1-c1/p1 - 100GE-port1 ConnectX5-2p100GE.
1107         - s61-t210-tg1-c1/p2 - 100GE-port2 ConnectX5-2p100GE.
1108         - s61-t210-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1109         - s61-t210-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1110         - s61-t210-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1111         - s61-t210-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1112         - s61-t210-tg1-c3/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1113         - s61-t210-tg1-c3/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1114 ```
1115
1116 #### 3-Node-Haswell Servers (3n-hsw) PROD
1117
1118 ```
1119  1. SUT [Server-Type-A1]:
1120     - testbedname: testbed1.
1121     - hostname: t1-sut1.
1122     - CIMC IP: 10.30.50.17
1123     - Host IP: 10.30.51.17
1124     - portnames:
1125         - t1-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1126         - t1-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1127         - t1-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1128         - t1-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1129         - t1-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1130         - t1-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1131         - t1-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1132         - t1-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1133         - t1-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1134         - t1-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1135  2. SUT [Server-Type-A1]:
1136     - testbedname: testbed1.
1137     - hostname: t1-sut2.
1138     - CIMC IP: 10.30.50.18
1139     - Host IP: 10.30.51.18
1140     - portnames:
1141         - t1-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1142         - t1-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1143         - t1-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1144         - t1-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1145         - t1-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1146         - t1-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1147         - t1-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1148         - t1-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1149         - t1-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1150         - t1-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1151  3. TG [Server-Type-A2]:
1152     - testbedname: testbed1.
1153     - hostname: t1-tg1.
1154     - CIMC IP: 10.30.50.16
1155     - Host IP: 10.30.51.16
1156     - portnames:
1157         - t1-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1158         - t1-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1159         - t1-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1160         - t1-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1161         - t1-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1162         - t1-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1163         - t1-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1164         - t1-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1165         - t1-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1166         - t1-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1167         - t1-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1168         - t1-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1169  4. SUT [Server-Type-A1]:
1170     - testbedname: testbed2.
1171     - hostname: t2-sut1.
1172     - CIMC IP: 10.30.50.21
1173     - Host IP: 10.30.51.21
1174     - portnames:
1175         - t2-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1176         - t2-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1177         - t2-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1178         - t2-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1179         - t2-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1180         - t2-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1181         - t2-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1182         - t2-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1183         - t2-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1184         - t2-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1185  5. SUT [Server-Type-A1]:
1186     - testbedname: testbed2.
1187     - hostname: t2-sut2.
1188     - CIMC IP: 10.30.50.22
1189     - Host IP: 10.30.51.22
1190     - portnames:
1191         - t2-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1192         - t2-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1193         - t2-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1194         - t2-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1195         - t2-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1196         - t2-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1197         - t2-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1198         - t2-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1199         - t2-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1200         - t2-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1201  6. TG [Server-Type-A2]:
1202     - testbedname: testbed2.
1203     - hostname: t2-tg1.
1204     - CIMC IP: 10.30.50.20
1205     - Host IP: 10.30.51.20
1206     - portnames:
1207         - t2-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1208         - t2-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1209         - t2-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1210         - t2-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1211         - t2-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1212         - t2-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1213         - t2-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1214         - t2-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1215         - t2-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1216         - t2-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1217         - t2-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1218         - t2-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1219  7. SUT [Server-Type-A1]:
1220     - testbedname: testbed3.
1221     - hostname: t3-sut1.
1222     - CIMC IP: 10.30.50.25
1223     - Host IP: 10.30.51.25
1224     - portnames:
1225         - t3-sut1-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1226         - t3-sut1-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1227         - t3-sut1-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1228         - t3-sut1-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1229         - t3-sut1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1230         - t3-sut1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1231         - t3-sut1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1232         - t3-sut1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1233         - t3-sut1-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1234         - t3-sut1-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1235  8. SUT [Server-Type-A1]:
1236     - testbedname: testbed3.
1237     - hostname: t3-sut2.
1238     - CIMC IP: 10.30.50.26
1239     - Host IP: 10.30.51.26
1240     - portnames:
1241         - t3-sut2-c1/p1 - 10GE port1 on Intel NIC x520 2p10GE.
1242         - t3-sut2-c1/p2 - 10GE port2 on Intel NIC x520 2p10GE.
1243         - t3-sut2-c2/p1 - 40GE port1 on Cisco VIC 1385 2p40GE.
1244         - t3-sut2-c2/p2 - 40GE port2 on Cisco VIC 1385 2p40GE.
1245         - t3-sut2-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1246         - t3-sut2-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1247         - t3-sut2-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1248         - t3-sut2-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1249         - t3-sut2-cm/p1 - 10GE port1 on Cisco VIC 1227 2p10GE.
1250         - t3-sut2-cm/p2 - 10GE port2 on Cisco VIC 1227 2p10GE.
1251  9. TG [Server-Type-A2]:
1252     - testbedname: testbed3.
1253     - hostname: t3-tg1.
1254     - CIMC IP: 10.30.50.24
1255     - Host IP: 10.30.51.24
1256     - portnames:
1257         - t3-tg1-c1/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1258         - t3-tg1-c1/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1259         - t3-tg1-c2/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1260         - t3-tg1-c2/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1261         - t3-tg1-c3/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1262         - t3-tg1-c3/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1263         - t3-tg1-c4/p1 - 40GE port1 on Intel NIC xl710 2p40GE.
1264         - t3-tg1-c4/p2 - 40GE port2 on Intel NIC xl710 2p40GE.
1265         - t3-tg1-c5/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1266         - t3-tg1-c5/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1267         - t3-tg1-c6/p1 - 10GE port1 on Intel NIC x710 2p10GE.
1268         - t3-tg1-c6/p2 - 10GE port2 on Intel NIC x710 2p10GE.
1269 ```
1270
1271 #### 3-Node-Skylake Servers (3n-skx) PROD
1272
1273 ```
1274 - ServerB11 [Server-Type-B1]:
1275     - testbedname: testbed31.
1276     - hostname: s11-t31-sut1.
1277     - IPMI IP: 10.30.50.43
1278     - Host IP: 10.30.51.46
1279     - portnames:
1280         - s11-t31-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1281         - s11-t31-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1282         - s11-t31-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1283         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1284         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1285         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1286         - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1287         - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1288 - ServerB12 [Server-Type-B1]:
1289     - testbedname: testbed31.
1290     - hostname: s12-t31-sut2.
1291     - IPMI IP: 10.30.50.44
1292     - Host IP: 10.30.51.47
1293     - portnames:
1294         - s12-t31-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1295         - s12-t31-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1296         - s12-t31-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1297         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1298         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1299         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1300         - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1301         - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1302 - ServerB13 [Server-Type-B2]:
1303     - testbedname: testbed31.
1304     - hostname: s13-t31-tg1.
1305     - IPMI IP: 10.30.50.45
1306     - Host IP: 10.30.51.48
1307     - portnames:
1308         - s13-t31-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1309         - s13-t31-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1310         - s13-t31-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1311         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1312         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1313         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1314         - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1315         - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1316 - ServerB14 [Server-Type-B1]:
1317     - testbedname: testbed32.
1318     - hostname: s14-t32-sut1.
1319     - IPMI IP: 10.30.50.55
1320     - Host IP: 10.30.51.58
1321     - portnames:
1322         - s14-t32-sut1-c2/p1 - 10GE-port1 x710-4p10GE.
1323         - s14-t32-sut1-c2/p2 - 10GE-port2 x710-4p10GE.
1324         - s14-t32-sut1-c2/p3 - 10GE-port3 x710-4p10GE.
1325         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
1326         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1327         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1328         - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1329         - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1330 - ServerB15 [Server-Type-B1]:
1331     - testbedname: testbed32.
1332     - hostname: s15-t32-sut2.
1333     - IPMI IP: 10.30.50.56
1334     - Host IP: 10.30.51.59
1335     - portnames:
1336         - s15-t32-sut2-c2/p1 - 10GE-port1 x710-4p10GE.
1337         - s15-t32-sut2-c2/p2 - 10GE-port2 x710-4p10GE.
1338         - s15-t32-sut2-c2/p3 - 10GE-port3 x710-4p10GE.
1339         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
1340         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1341         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1342         - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1343         - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1344 - ServerB16 [Server-Type-B2]:
1345     - testbedname: testbed32.
1346     - hostname: s16-t32-tg1.
1347     - IPMI IP: 10.30.50.57
1348     - Host IP: 10.30.51.60
1349     - portnames:
1350         - s16-t32-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1351         - s16-t32-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1352         - s16-t32-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1353         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1354         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1355         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1356         - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
1357         - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
1358 ```
1359
1360 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
1361
1362 Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
1363
1364 ```
1365 - ServerB22 [Server-Type-B5]:
1366     - testbedname: testbed35.
1367     - hostname: s22-t35-sut1 (vex-yul-rot-netgate-1).
1368     - IPMI IP: 10.30.51.29 - screen -r /dev/ttyUSB0
1369     - Host IP: 10.30.51.9
1370     - portnames:
1371         - s22-t35-sut1-p1 - 10GE-port1 ix0 82599.
1372         - s22-t35-sut1-p2 - 10GE-port2 ix1 82599.
1373     - 1GB ports (tbd)
1374 - ServerB23 [Server-Type-B5]:
1375     - testbedname: testbed35.
1376     - hostname: s23-t35-sut2 (vex-yul-rot-netgate-2).
1377     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB1
1378     - Host IP: 10.30.51.10
1379     - portnames:
1380         - s23-t35-sut1-p1 - 10GE-port1 ix0 82599.
1381         - s23-t35-sut1-p2 - 10GE-port2 ix1 82599.
1382     - 1GB ports (tbd)
1383 - ServerB24 [Server-Type-B5]:
1384     - testbedname: testbed35.
1385     - hostname: s24-t35-sut3 (vex-yul-rot-netgate-3).
1386     - IPMI IP: 10.30.51.30 - screen -r /dev/ttyUSB2
1387     - Host IP: 10.30.51.11
1388     - portnames:
1389         - s24-t35-sut1-p1 - 10GE-port1 ix0 82599.
1390         - s24-t35-sut1-p2 - 10GE-port2 ix1 82599.
1391     - 1GB ports (tbd)
1392 ```
1393
1394 #### 3-Node-Taishan Servers (3n-tsh) WIP
1395
1396 Note: ServerB19 (TG) is shared between testbed33 & testbed34
1397
1398 ```
1399 - ServerB17 [Server-Type-B3]:
1400     - testbedname: testbed33.
1401     - hostname: s17-t33-sut1.
1402     - IPMI IP: 10.30.50.36
1403     - Host IP: 10.30.51.36
1404     - portnames:
1405         - s17-t33-sut1-c6/p1 - 10GE-port1 x520-2p10GE.
1406         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
1407         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
1408         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
1409 - ServerB18 [Server-Type-B3]:
1410     - testbedname: testbed33.
1411     - hostname: s18-t33-sut2.
1412     - IPMI IP: 10.30.50.37
1413     - Host IP: 10.30.51.37
1414     - portnames:
1415         - s18-t33-sut2-c6/p1 - 10GE-port1 x520-2p10GE.
1416         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
1417         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
1418         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
1419 - ServerB19 [Server-Type-B2]:
1420     - testbednames: testbed33 and testbed34.
1421     - hostname: s19-t33t34-tg1.
1422     - IPMI IP: 10.30.50.46
1423     - Host IP: 10.30.51.49
1424     - portnames:
1425         - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
1426         - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
1427         - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
1428         - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
1429         - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
1430         - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
1431         - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
1432         - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
1433         - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
1434         - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
1435 - ServerB20 [Server-Type-B4]:
1436     - testbedname: testbed34.
1437     - hostname: s20-t34-sut1.
1438     - IPMI IP: N/A
1439     - Host IP: 10.30.51.41
1440     - portnames:
1441         - s20-t34-sut1-ca/p1 - 10GE-port1 Marvell.
1442         - s20-t34-sut1-ca/p2 - 10GE-port2 Marvell.
1443 - ServerB21 [Server-Type-B4]:
1444     - testbedname: testbed34.
1445     - hostname: s21-t34-sut2.
1446     - IPMI IP: N/A
1447     - Host IP: 10.30.51.42
1448     - portnames:
1449         - s21-t34-sut2-ca/p1 - 10GE-port1 Marvell.
1450         - s21-t34-sut2-ca/p2 - 10GE-port2 Marvell.
1451 ```
1452
1453 #### 3-Node-Denverton Servers (3n-dnv) WIP
1454
1455 ```
1456 - ServerB30 [Server-Type-B10]:
1457     - testbednames: testbed35.
1458     - hostname: s30-t35-sut1.
1459     - IPMI IP: 10.30.55.12
1460     - Host IP: 10.32.8.12
1461     - portnames:
1462         - s30-t35-sut1-p1 - 10GE-port1 x553 copper port.
1463         - s30-t35-sut1-p2 - 10GE-port2 x553 copper port.
1464         - s30-t35-sut1-p3 - 10GE-port3 x553 fiber port.
1465         - s30-t35-sut1-p4 - 10GE-port4 x553 fiber port.
1466 - ServerB31 [Server-Type-B10]:
1467     - testbednames: testbed35.
1468     - hostname: s31-t35-sut2.
1469     - IPMI IP: 10.30.55.13
1470     - Host IP: 10.32.8.13
1471     - portnames:
1472         - s31-t35-sut2-p1 - 10GE-port1 x553 copper port.
1473         - s31-t35-sut2-p2 - 10GE-port2 x553 copper port.
1474         - s31-t35-sut2-p3 - 10GE-port3 x553 fiber port.
1475         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
1476 ```
1477
1478 #### 3-Node-Mcbin Servers (3n-mcb) TODO
1479
1480 ```
1481 To be completed.
1482 ```
1483
1484 ### Per Testbed Wiring
1485
1486 #### 1-Node-Skylake Wiring (1n-skx) PROD
1487
1488 ```
1489 - testbed11:
1490     - ring1 10GE-ports x710-4p10GE:
1491         - s1-t11-sut1-c2/p1 to s1-t11-sut1-c4/p1.
1492     - ring2 10GE-ports x710-4p10GE:
1493         - s1-t11-sut1-c2/p2 to s1-t11-sut1-c4/p2.
1494     - ring3 10GE-ports x710-4p10GE:
1495         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1496     - ring4 10GE-ports x710-4p10GE:
1497         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
1498 - testbed12:
1499     - ring1 10GE-ports x710-4p10GE:
1500         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
1501     - ring2 10GE-ports x710-4p10GE:
1502         - s2-t12-sut1-c2/p2 to s2-t12-sut1-c4/p2.
1503     - ring3 10GE-ports x710-4p10GE:
1504         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1505     - ring4 10GE-ports x710-4p10GE:
1506         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
1507 ```
1508
1509 #### 1-Node-Thunderx2 Wiring (1n-tx2) WIP
1510
1511 ```
1512 - testbed13:
1513     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
1514         - s27-t13-sut1-c1/p2 - s27-t13-sut1-c3/p1.
1515     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
1516         - s27-t13-sut1-c3/p2 - s27-t13-sut1-c6/p1.
1517     - ring3 40GE-ports XL710-QDA2-2p40GE on SUTs:
1518         - s27-t13-sut1-c6/p2 - s27-t13-sut1-c1/p1.
1519 ```
1520
1521 #### 1-Node-Cascadelake Wiring (1n-clx) SETUP
1522
1523 ```
1524 - testbed14:
1525     - ring1 10GE-ports x710-4p10GE:
1526         - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
1527     - ring2 10GE-ports x710-4p10GE:
1528         - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
1529     - ring3 10GE-ports x710-4p10GE:
1530         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1531     - ring4 10GE-ports x710-4p10GE:
1532         - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
1533 ```
1534
1535 #### 2-Node-Skylake Wiring (2n-skx) PROD
1536
1537 ```
1538 - testbed21:
1539     - ring1 10GE-ports x710-4p10GE on SUT:
1540         - s4-t21-tg1-c2/p1 to s3-t21-sut1-c2/p1.
1541         - s3-t21-sut1-c2/p2 to s4-t21-tg1-c2/p2.
1542     - ring2 10GE-ports x710-4p10GE on SUT:
1543         - s4-t21-tg1-c2/p3 to s3-t21-sut1-c2/p3.
1544         - s3-t21-sut1-c2/p4 to s4-t21-tg1-c2/p4.
1545     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1546         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
1547         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
1548 - testbed22:
1549     - ring1 10GE-ports x710-4p10GE on SUT:
1550         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
1551         - s5-t22-sut1-c2/p2 to s6-t22-tg1-c2/p2.
1552     - ring2 10GE-ports x710-4p10GE on SUT:
1553         - s6-t22-tg1-c2/p3 to s5-t22-sut1-c2/p3.
1554         - s5-t22-sut1-c2/p4 to s6-t22-tg1-c2/p4.
1555     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1556         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
1557         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
1558 - testbed23:
1559     - ring1 10GE-ports x710-4p10GE on SUT:
1560         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
1561         - s7-t23-sut1-c2/p2 to s8-t23-tg1-c2/p2.
1562     - ring2 10GE-ports x710-4p10GE on SUT:
1563         - s8-t23-tg1-c2/p3 to s7-t23-sut1-c2/p3.
1564         - s7-t23-sut1-c2/p4 to s8-t23-tg1-c2/p4.
1565     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1566         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
1567         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
1568 - testbed24:
1569     - ring1 10GE-ports x710-4p10GE on SUT:
1570         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
1571         - s9-t24-sut1-c2/p2 to s10-t24-tg1-c2/p2.
1572     - ring2 10GE-ports x710-4p10GE on SUT:
1573         - s10-t24-tg1-c2/p3 to s9-t24-sut1-c2/p3.
1574         - s9-t24-sut1-c2/p4 to s10-t24-tg1-c2/p4.
1575     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1576         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
1577         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
1578 ```
1579
1580 #### 2-Node-Denverton Wiring (2n-dnv) WIP
1581
1582 ```
1583 - testbed26:
1584     - ring1 10GE-ports x553 copper port on SUT:
1585         - s28-t26t35-tg1-c4/p1 to s29-t26-sut1-p1.
1586         - s28-t26t35-tg1-c9/p1 to s29-t26-sut1-p2.
1587     - ring2 10GE-ports x553 fiber port on SUT:
1588         - s28-t26t35-tg1-c2/p1 to s29-t26-sut1-p3.
1589         - s28-t26t35-tg1-c2/p2 to s29-t26-sut1-p4.
1590 ```
1591
1592 #### 2-Node-IxiaPS1L47 Wiring (2n-ps1) VERIFY
1593
1594 ```
1595 - testbed25:
1596     - link1 10GE-port x710-4p10GE on SUT:
1597         - t25-tg1-p1 to t25-sut1-c2/p1.
1598     - link2 10GE-port x710-4p10GE on SUT:
1599         - t25-tg1-p2 to t25-sut1-c2/p2.
1600     - link3 10GE-port x710-4p10GE on SUT:
1601         - t25-tg1-p3 to t25-sut1-c2/p3.
1602     - link4 10GE-port x710-4p10GE on SUT:
1603         - t25-tg1-p4 to t25-sut1-c2/p4.
1604 ```
1605
1606 #### 2-Node-Cascadelake Wiring (2n-clx) PROD
1607
1608 ```
1609 - testbed27:
1610     - ring1 10GE-ports x710-4p10GE on SUT:
1611         - s34-t27-tg1-c2/p1 to s33-t27-sut1-c2/p1.
1612         - s33-t27-sut1-c2/p2 to s34-t27-tg1-c2/p2.
1613     - ring2 10GE-ports x710-4p10GE on SUT:
1614         - s34-t27-tg1-c2/p3 to s33-t27-sut1-c2/p3.
1615         - s33-t27-sut1-c2/p4 to s34-t27-tg1-c2/p4.
1616     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1617         - s34-t27-tg1-c4/p1 to s33-t27-sut1-c4/p1.
1618         - s33-t27-sut1-c4/p2 to s34-t27-tg1-c4/p2.
1619     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1620         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
1621         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
1622 - testbed28:
1623     - ring1 10GE-ports x710-4p10GE on SUT:
1624         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
1625         - s35-t28-sut1-c2/p2 to s36-t28-tg1-c2/p2.
1626     - ring2 10GE-ports x710-4p10GE on SUT:
1627         - s36-t28-tg1-c2/p3 to s35-t28-sut1-c2/p3.
1628         - s35-t28-sut1-c2/p4 to s36-t28-tg1-c2/p4.
1629     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1630         - s36-t28-tg1-c4/p1 to s35-t28-sut1-c4/p1.
1631         - s35-t28-sut1-c4/p2 to s36-t28-tg1-c4/p2.
1632     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1633         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
1634         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
1635 - testbed29:
1636     - ring1 10GE-ports x710-4p10GE on SUT:
1637         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
1638         - s37-t29-sut1-c2/p2 to s38-t29-tg1-c2/p2.
1639     - ring2 10GE-ports x710-4p10GE on SUT:
1640         - s38-t29-tg1-c2/p3 to s37-t29-sut1-c2/p3.
1641         - s37-t29-sut1-c2/p4 to s38-t29-tg1-c2/p4.
1642     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1643         - s38-t29-tg1-c4/p1 to s37-t29-sut1-c4/p1.
1644         - s37-t29-sut1-c4/p2 to s38-t29-tg1-c4/p2.
1645     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1646         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
1647         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
1648 ```
1649
1650 #### 2-Node-Zen2 Wiring (2n-zen2) SETUP
1651
1652 ```
1653 - testbed210:
1654     - ring1 10GE-ports x710-4p10GE on SUT:
1655         - s61-t210-tg1-c2/p1 to s60-t210-sut1-c1/p1.
1656         - s60-t210-sut1-c1/p2 to s61-t210-tg1-c2/p2.
1657     - ring2 10GE-ports x710-4p10GE on SUT:
1658         - s61-t210-tg1-c2/p3 to s60-t210-sut1-c1/p3.
1659         - s60-t210-sut1-c1/p4 to s61-t210-tg1-c2/p4.
1660     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1661         - s61-t210-tg1-c3/p1 to s60-t210-sut1-c2/p1.
1662         - s60-t210-sut1-c2/p2 to s61-t210-tg1-c3/p2.
1663     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
1664         - s61-t210-tg1-c1/p1 to s60-t210-sut1-c3/p1.
1665         - s60-t210-sut1-c3/p2 to s61-t210-tg1-c1/p2.
1666 ```
1667
1668 #### 3-Node-Haswell Wiring (3n-hsw) PROD
1669
1670 ```
1671  1. testbed1:
1672     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1673         - t1-tg1-c1/p1 to t1-sut1-c1/p2.
1674         - t1-sut1-c1/p1 to t1-sut2-c1/p2.
1675         - t1-sut2-c1/p1 to t1-tg1-c1/p2.
1676     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1677         - t1-tg1-c2/p1 to t1-sut1-c2/p2.
1678         - t1-sut1-c2/p1 to t1-sut2-c2/p2.
1679         - t1-sut2-c2/p1 to t1-tg1-c2/p2.
1680     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1681         - t1-tg1-c4/p1 to t1-sut1-c4/p2.
1682         - t1-sut1-c4/p1 to t1-sut2-c4/p2.
1683         - t1-sut2-c4/p1 to t1-tg1-c4/p2.
1684     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1685         - t1-tg1-c5/p1 to t1-sut1-c5/p2.
1686         - t1-sut1-c5/p1 to t1-sut2-c5/p2.
1687         - t1-sut2-c5/p1 to t1-tg1-c5/p2.
1688     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1689         - t1-tg1-c2/p1 to t1-sut1-cm/p2.
1690         - t1-sut1-cm/p1 to t1-sut2-cm/p2.
1691         - t1-sut2-cm/p1 to t1-tg1-c2/p2.
1692     - TG loopback ports Intel NIC x710 2p10GE
1693         - t1-tg1-c6/p1 to t1-tg1-c6/p2.
1694
1695  2. testbed2:
1696     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1697         - t2-tg1-c1/p1 to t2-sut1-c1/p2.
1698         - t2-sut1-c1/p1 to t2-sut2-c1/p2.
1699         - t2-sut2-c1/p1 to t2-tg1-c1/p2.
1700     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1701         - t2-tg1-c2/p1 to t2-sut1-c2/p2.
1702         - t2-sut1-c2/p1 to t2-sut2-c2/p2.
1703         - t2-sut2-c2/p1 to t2-tg1-c2/p2.
1704     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1705         - t2-tg1-c4/p1 to t2-sut1-c4/p2.
1706         - t2-sut1-c4/p1 to t2-sut2-c4/p2.
1707         - t2-sut2-c4/p1 to t2-tg1-c4/p2.
1708     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1709         - t2-tg1-c5/p1 to t2-sut1-c5/p2.
1710         - t2-sut1-c5/p1 to t2-sut2-c5/p2.
1711         - t2-sut2-c5/p1 to t2-tg1-c5/p2.
1712     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1713         - t2-tg1-c2/p1 to t2-sut1-cm/p2.
1714         - t2-sut1-cm/p1 to t2-sut2-cm/p2.
1715         - t2-sut2-cm/p1 to t2-tg1-c2/p2.
1716     - TG loopback ports Intel NIC x710 2p10GE
1717         - t2-tg1-c6/p1 to t2-tg1-c6/p2.
1718
1719  3. testbed3:
1720     - ring of 40GE ports on Cisco VIC 1385 2p40GE on SUTs
1721         - t3-tg1-c1/p1 to t3-sut1-c1/p2.
1722         - t3-sut1-c1/p1 to t3-sut2-c1/p2.
1723         - t3-sut2-c1/p1 to t3-tg1-c1/p2.
1724     - ring of 10GE ports on Intel NIC x520 2p10GE on SUTs
1725         - t3-tg1-c2/p1 to t3-sut1-c2/p2.
1726         - t3-sut1-c2/p1 to t3-sut2-c2/p2.
1727         - t3-sut2-c2/p1 to t3-tg1-c2/p2.
1728     - ring of 40GE ports on Intel NIC xl710 2p40GE on SUTs
1729         - t3-tg1-c4/p1 to t3-sut1-c4/p2.
1730         - t3-sut1-c4/p1 to t3-sut2-c4/p2.
1731         - t3-sut2-c4/p1 to t3-tg1-c4/p2.
1732     - ring of 10GE ports on Intel NIC x710 2p10GE on SUTs
1733         - t3-tg1-c5/p1 to t3-sut1-c5/p2.
1734         - t3-sut1-c5/p1 to t3-sut2-c5/p2.
1735         - t3-sut2-c5/p1 to t3-tg1-c5/p2.
1736     - ring of 10GE ports on Cisco VIC 1227 2p10GE on SUTs
1737         - t3-tg1-c2/p1 to t3-sut1-cm/p2.
1738         - t3-sut1-cm/p1 to t3-sut2-cm/p2.
1739         - t3-sut2-cm/p1 to t3-tg1-c2/p2.
1740     - TG loopback ports Intel NIC x710 2p10GE
1741         - t3-tg1-c6/p1 to t3-tg1-c6/p2.
1742 ```
1743
1744 #### 3-Node-Skylake Wiring (3n-skx) PROD
1745
1746 ```
1747 - testbed31:
1748     - ring1 10GE-ports x710-4p10GE on SUTs:
1749         - s13-t31-tg1-c2/p1 to s11-t31-sut1-c2/p1.
1750         - s11-t31-sut1-c2/p2 to s12-t31-sut2-c2/p2.
1751         - s12-t31-sut2-c2/p1 to s13-t31-tg1-c2/p2.
1752     - ring2 10GE-ports x710-4p10GE on SUT:
1753         - s13-t31-tg1-c2/p3 to s11-t31-sut1-c2/p3.
1754         - s11-t31-sut1-c2/p4 to s12-t31-sut2-c2/p4.
1755         - s12-t31-sut2-c2/p3 to s13-t31-tg1-c2/p4.
1756     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1757         - s13-t31-tg1-c4/p1 to s11-t31-sut1-c4/p1.
1758         - s11-t31-sut1-c4/p2 to s12-t31-sut2-c4/p2.
1759         - s12-t31-sut2-c4/p1 to s13-t31-tg1-c4/p2.
1760     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1761         - s13-t31-tg1-c9/p1 to s11-t31-sut1-c9/p1.
1762         - s11-t31-sut1-c9/p2 to s12-t31-sut2-c9/p2.
1763         - s12-t31-sut2-c9/p1 to s13-t31-tg1-c9/p2.
1764     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1765         - s13-t31-tg1-c10/p1 to s13-t31-tg1-c10/p2.
1766         - s13-t31-tg1-c10/p3 to s13-t31-tg1-c10/p4.
1767 - testbed32:
1768     - ring1 10GE-ports x710-4p10GE on SUTs:
1769         - s16-t32-tg1-c2/p1 to s14-t32-sut1-c2/p1.
1770         - s14-t32-sut1-c2/p2 to s15-t32-sut2-c2/p2.
1771         - s15-t32-sut2-c2/p1 to s16-t32-tg1-c2/p2.
1772     - ring2 10GE-ports x710-4p10GE on SUT:
1773         - s16-t32-tg1-c2/p3 to s14-t32-sut1-c2/p3.
1774         - s14-t32-sut1-c2/p4 to s15-t32-sut2-c2/p4.
1775         - s15-t32-sut2-c2/p3 to s16-t32-tg1-c2/p4.
1776     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
1777         - s16-t32-tg1-c4/p1 to s14-t32-sut1-c4/p1.
1778         - s14-t32-sut1-c4/p2 to s15-t32-sut2-c4/p2.
1779         - s15-t32-sut2-c4/p1 to s16-t32-tg1-c4/p2.
1780     - FUTURE ring4 100GE-ports ConnectX5-2p100GE on SUT:
1781         - s16-t32-tg1-c9/p1 to s14-t32-sut1-c9/p1.
1782         - s14-t32-sut1-c9/p2 to s15-t32-sut2-c9/p2.
1783         - s15-t32-sut2-c9/p1 to s16-t32-tg1-c9/p2.
1784     - ring5 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
1785         - s16-t32-tg1-c10/p1 to s16-t32-tg1-c10/p2.
1786         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
1787 ```
1788
1789 #### 3-Node-Rangeley Wiring (3n-rng) TODO
1790
1791 ```
1792 To be completed.
1793 ```
1794
1795 #### 3-Node-Taishan Wiring (3n-tsh) WIP
1796
1797 ```
1798 - testbed33:
1799     - ring1 10GE-ports x520-2p10GE on SUTs:
1800         - t33t34-tg1-c2/p2 - t33-sut1-c6/p2.
1801         - t33-sut1-c6/p1 - t33-sut2-c6/p2.
1802         - t33-sut2-c6/p1 - t33t34-tg1-c2/p1.
1803     - ring2 25GE-ports cx4-2p25GE on SUTs:
1804         - t33t34-tg1-c4/p2 - t33-sut1-c4/p2.
1805         - t33-sut1-c4/p1 - t33-sut2-c4/p2.
1806         - t33-sut2-c4/p1 - t33t34-tg1-c4/p1.
1807 ```
1808
1809 #### 3-Node-Mcbin Wiring (3n-mcb) WIP
1810
1811 ```
1812 - testbed34:
1813     - ring1 10GE-ports Marvell on SUTs:
1814         - t33t34-tg1-c2/p3 - t34-sut1-ca/p1.
1815         - t34-sut1-ca/p2 - t34-sut2-ca/p1.
1816         - t34-sut2-ca/p2 - t33t34-tg1-c2/p4.
1817 ```
1818
1819 #### 3-Node-Denverton Wiring (3n-dnv) WIP
1820
1821 ```
1822 - testbed35:
1823     - ring1 10GE-ports x553 copper port on SUTs:
1824         - s28-t26t35-tg1-c8/p1 to s30-t35-sut1-p2.
1825         - s30-t35-sut1-p1 to s31-t35-sut2-p1.
1826         - s28-t26t35-tg1-c10/p1 to s31-t35-sut2-p2.
1827     - ring2 10GE-ports x553 fiber port on SUTs:
1828         - s28-t26t35-tg1-c6/p1 to s30-t35-sut1-p4.
1829         - s30-t35-sut1-p3 to s31-t35-sut2-p3.
1830         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
1831 ```
1832
1833 ## Inventory
1834
1835 ### Appliances
1836
1837 ```
1838 1. Ixia PerfectStorm One Appliance
1839     - 1 * PS10GE4NG
1840         - Chassis: PS10GE4NG.
1841         - Motherboard: SuperMicro X11DPG-QT.
1842         - Processors: Quad-Core, Intel Processor.
1843         - HW accelerators: FPGA offload.
1844         - RAM Memory: 64GB.
1845         - Disks: 1 * 1 TB, Enterprise Class, High MTBF.
1846         - Physical Interfaces: 4 * 10GE SFP+.
1847         - Operating System: Native IxOS.
1848 ```
1849
1850 ### Arm Servers
1851
1852 ```
1853 1. Arm Cortex A-72 servers
1854     - 1 * ThunderX2
1855         - Chassis: Marvell ThunderX2
1856         - Processors: 2* ThunderX2 CN9975 ~ 112* ThunderX2.
1857         - RAM Memory: 4* 32GB RDIMM
1858         - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
1859     - 2 * Huawei TaiShan 2280.
1860         - Chassis: Huawei TaiShan 2280.
1861         - Processors: 1* hip07-d05 ~ 64* Arm Cortex-A72.
1862         - RAM Memory: 8* 16GB DDR4-2400MT/s.
1863         - Disks: 1* 4TB SATA HDD.
1864     - 3 * MACCHIATObin
1865         - Chassis: MACCHIATObin.
1866         - Processors: 1* Armada 8040 ~ 4* Arm Cortex-A72.
1867         - RAM Memory: 1* 16GB DDR4.
1868         - Disks: 1* 128GB(?) SATA SDD.
1869 ```
1870
1871 ### Xeon and Atom Servers
1872
1873 ```
1874 1. Intel Xeon servers:
1875     - 20 * SuperMicro SYS-7049GP-TRT with Xeon Skylake processors.
1876         - Chassis: SuperMicro SYS-7049GP-TRT.
1877         - Motherboard: SuperMicro X11DPG-QT.
1878         - Processors: 2* Intel Platinum 8180 2.5 GHz.
1879         - RAM Memory: 16* 16GB DDR4-2666MHz.
1880         - Disks: 2* 1.6TB 6G SATA SSD.
1881 2. Intel Atom servers with Rangely processors.
1882     - 3 * Netgate XG-2758-1u
1883         - Chassis: Netgate XG-2758-1u
1884         - Processors: 1* Rangely (Atom) C2758 2.4 GHz
1885         - RAM Memory: 16GB ECC
1886         - Disks: 150 GB
1887 ```
1888
1889 ### Network Interface Cards
1890
1891 ```
1892 1. 10GE NICs
1893     - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
1894     - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
1895     - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
1896 2. 25GE NICs
1897     - 12 * Intel® Ethernet Network Adapter XXV710-DA2
1898 3. 40GE NICs
1899     - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
1900 4. 100GE NICs
1901     - 4 * mcx556a-edat NICs (not on site yet, in transit)
1902 ```
1903
1904 ### Pluggables and Cables
1905
1906 Pluggables:
1907
1908 ```
1909 1. 10GE SFP+
1910     - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
1911     - 80 * 10G SR optic (generic, "Intel" compatible branded)
1912 2. 25GE SFP28
1913     - None
1914 3. 40GE QSFP+
1915     - None
1916 4. 100GE
1917     - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
1918 ```
1919
1920 Standalone cables:
1921
1922 ```
1923 1. 10GE
1924     - None
1925 2. 25GE
1926     - None
1927 3. 40GE QSFP+
1928     - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
1929 4. 100GE
1930     - None
1931 ```
1932
1933 ### Other Parts