feat(pxe): Migrate Ubuntu Jammy I.
[csit.git] / docs / lab / testbed_specifications.md
index b52ada8..fad1bdc 100644 (file)
    1. [2-Node-Cascadelake Xeon Intel (2n-clx)](#2-node-cascadelake-xeon-intel-2n-clx)
    1. [2-Node-Zen2 EPYC AMD (2n-zn2)](#2-node-zen2-epyc-amd-2n-zn)
    1. [2-Node-ThunderX2 Arm Marvell (2x-tx2)](#2-node-thunderx2-arm-marvell-2n-tx2)
+   1. [2-Node-Icelake Xeon Intel (2n-icx)](#2-node-icelake-xeon-intel-2n-icx)
    1. [3-Node-Skylake Xeon Intel (3n-skx)](#3-node-skylake-xeon-intel-3n-skx)
-   1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
    1. [3-Node-Rangeley Atom Testbeds](#3-node-rangeley-atom-testbeds)
+   1. [3-Node-TaiShan Arm Huawei (3n-tsh)](#3-node-taishan-arm-huawei-3n-tsh)
+   1. [3-Node-Altra Arm Ampere (3n-alt)](#3-node-altra-arm-armpere-3n-alt)
+   1. [3-Node-Icelake Xeon Intel (3n-icx)](#3-node-icelake-xeon-intel-3n-icx)
+   1. [3-Node-SnowRidge Atom Intel (3n-snr)](#3-node-snowridge-atom-intel-3n-snr)
 1. [Server Management](#server-management)
    1. [Requirements](#requirements)
    1. [Addressing](#addressing)
       1. [2-Node-Cascadelake Servers (2n-clx) PROD](#2-node-cascadelake-servers-2n-clx-prod)
       1. [2-Node-Zen2 Servers (2n-zn2) PROD](#2-node-zen2-servers-2n-zn2-prod])
       1. [2-Node-ThunderX2 Servers (2n-tx2) PROD](#2-node-thunderx2-servers-2n-tx2-prod)
+      1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
       1. [3-Node-Skylake Servers (3n-skx) PROD](#3-node-skylake-servers-3n-skx-prod)
       1. [3-Node-Rangeley Servers (3n-rng) VERIFY](#3-node-rangeley-servers-3n-rng-verify)
       1. [3-Node-Taishan Servers (3n-tsh) PROD](#3-node-taishan-servers-3n-tsh-prod)
+      1. [3-Node-Altra Servers (3n-alt) PROD](#3-node-altra-servers-3n-alt-prod)
+      1. [3-Node-Icelake Servers (3n-icx) PROD](#3-node-icelake-servers-3n-icx-prod)
+      1. [3-Node-SnowRidge Servers (3n-snr) PROD](#3-node-snowridge-servers-3n-snr-prod)
    1. [Per Testbed Wiring](#per-testbed-wiring)
       1. [1-Node-Skylake Wiring (1n-skx) PROD](#1-node-skylake-wiring-1n-skx-prod)
       1. [1-Node-ThunderX2 Wiring (1n-tx2) PROD](#1-node-thunderx2-wiring-1n-tx2-prod)
       1. [2-Node-Cascadelake Wiring (2n-clx) PROD](#2-node-cascadelake-wiring-2n-clx-prod)
       1. [2-Node-Zen2 Wiring (2n-zn2) PROD](#2-node-zen2-wiring-2n-zn2-prod])
       1. [2-Node-ThunderX2 Wiring (2n-tx2) PROD](#2-node-thunderx2-wiring-2n-tx2-prod)
-      1. [3-Node-Haswell Wiring (3n-hsw) PROD](#3-node-haswell-wiring-3n-hsw-prod)
+      1. [2-Node-Icelake Servers (2n-icx) PROD](#2-node-icelake-servers-2n-icx-prod)
       1. [3-Node-Skylake Wiring (3n-skx) PROD](#3-node-skylake-wiring-3n-skx-prod)
-      1. [3-Node-Rangeley Wiring (3n-rng) TODO](#3-node-rangeley-wiring-3n-rng-todo)
+      1. [3-Node-Rangeley Wiring (3n-rng) VERIFY](#3-node-rangeley-wiring-3n-rng-todo)
       1. [3-Node-Taishan Wiring (3n-tsh) PROD](#3-node-taishan-wiring-3n-tsh-prod)
+      1. [3-Node-Altra Wiring (3n-alt) PROD](#3-node-altra-wiring-3n-alt-prod)
+      1. [3-Node-Icelake Wiring (3n-icx) PROD](#3-node-icelake-wiring-3n-icx-prod)
+      1. [3-Node-SnowRidge Wiring (3n-snr) PROD](#3-node-snowridge-wiring-3n-snr-prod)
 1. [Inventory](#inventory)
    1. [Appliances](#appliances)
    1. [Arm Servers](#arm-servers)
@@ -69,22 +80,27 @@ hosted by LFN FD.io CSIT project.
 ### Summary List
 
 ```
- #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #clx #zn2
- 1. 1-Node-Haswell     nomad  hsw   ---   4    4    0    4    0    0    0    0    0    0    0    0
- 2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0
- 3. 1-Node-ThunderX2   perf   tx2   na    1    1    .5   0    .5   0    0    0    1    0    0    0
- 4. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0
- 5. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    1    0
- 6. 2-Node-Skylake     perf   skx   skx   4    4    4    0    8    0    0    0    0    0    0    0
- 7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0
- 8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0
- 9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    6    0
-10. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0
-11. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0
-12. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0
-13. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0
-14. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    2
-                                 Totals: 25   31   15    4   19    1    2    3    3    2    7    2
+ #. CSIT_tb          Purpose  SUT   TG    #TB  #SUT #TG  #hsw #skx #ps1 #rng #dnv #tx2 #tsh #alt #clx #zn2 #icx #snr
+ 1. 1-Node-Haswell     nomad  hsw   na    4    4    0    4    0    0    0    0    0    0    0    0    0    0    0
+ 2. 1-Node-Skylake     dev    skx   na    2    2    0    0    2    0    0    0    0    0    0    0    0    0    0
+ 3. 1-Node-ThunderX2   dev    tx2   na    2    2    0    0    0    0    0    0    2    0    0    0    0    0    0
+ 4. 1-Node-Cascadelake dev    clx   lcx   1    1    0    0    0    0    0    0    0    0    0    1    0    0    0
+ 5. 1-Node-AmpereAltra nomad  alt   na    2    2    0    0    0    0    0    0    0    0    2    0    0    0    0
+ 6. 2-Node-Skylake     perf   skx   skx   3    3    3    0    6    0    0    0    0    0    0    0    0    0    0
+ 7. 2-Node-Denverton   perf   dnv   skx   1    1    1    0    .5   0    0    1    0    0    0    0    0    0    0
+ 8. 2-Node-IxiaPS1L47  tcp    skx   ps1   1    1    1    0    1    1    0    0    0    0    0    0    0    0    0
+ 9. 2-Node-Cascadelake perf   clx   clx   3    3    3    0    0    0    0    0    0    0    0    6    0    0    0
+10. 2-Node-ThunderX2   perf   tx2   skx   1    1    .5   0    .5   0    0    0    1    0    0    0    0    0    0
+11. 2-Node-Icelake     perf   icx   icx   4    4    4    0    0    0    0    0    0    0    0    0    0    8    0
+12. 3-Node-Skylake     perf   skx   skx   2    4    2    0    6    0    0    0    0    0    0    0    0    0    0
+13. 3-Node-Rangeley    perf   rng   skx   1    3    1    0    0    0    2    0    0    0    0    0    0    0    0
+14. 3-Node-Taishan     perf   tsh   skx   1    2    .5   0    .5   0    0    0    0    2    0    0    0    0    0
+15. 3-Node-Altra       perf   alt   icx   1    2    1    0    0    0    0    0    0    0    2    0    0    1    0
+16. 3-Node-Denverton   perf   dnv   skx   1    2    1    0    .5   0    0    2    0    0    0    0    0    0    0
+17. 2-Node-Zen2        perf   zn2   zn2   1    1    1    0    0    0    0    0    0    0    0    0    2    0    0
+18. 3-Node-Icelake     perf   icx   icx   2    4    2    0    0    0    0    0    0    0    0    0    0    6    0
+19. 3-Node-SnowRidge   perf   snr   icx   1    2    .5   0    0    0    0    0    0    0    0    0    0    .5   2
+                                 Totals: 34   44  21.5   4   17    1    2    3    3    2    4    7    2  15.5   2
 ```
 
 ### 1-Node-Skylake Xeon Intel (1n-skx)
@@ -95,7 +111,7 @@ Used for FD.io VPP_Device functional driver tests.
 
 ### 1-Node-ThunderX2 Arm Marvell (1n-tx2)
 
-Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-B11) with NIC
+Each 1-Node-ThunderX2 testbed includes one SUT (Server-Type-E11) with NIC
 ports connected back-to-back ([Server Types](#server-types)).
 Used for FD.io VPP_Device functional driver tests.
 
@@ -143,8 +159,15 @@ Used for FD.io performance tests.
 
 ### 2-Node-ThunderX2 Arm Marvell (2x-tx2)
 
-Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-B9) and
-one TG (Server-Type-B12) connected in a 2-node circular topology
+Each 2-Node-ThunderX2 testbed includes one SUT (Server-Type-E22) and
+one TG (Server-Type-E31) connected in a 2-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 2-Node-Icelake Xeon Intel (2n-icx)
+
+Each 2-Node-Icelake testbed includes one SUT (Server-Type-F1) and
+one TG (Server-Type-F2) connected in a 2-node circular topology
 ([Server Types](#server-types)).
 Used for FD.io performance tests.
 
@@ -161,20 +184,42 @@ Each 3-Node-Skylake testbed includes two SUTs (Server-Type-B1) and one
 TG (Server-Type-B2) connected in a 3-node circular topology.
 Used for FD.io performance tests.
 
+### 3-Node-Rangeley Atom Testbeds
+
+Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
+TG (Server-Type-2) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
 ### 3-Node-TaiShan Arm Huawei (3n-tsh)
 
-Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-B3) and one
-TG (Server-Type-B12) connected in a 3-node circular topology
+Each 3-Node-TaiShan testbed includes two SUTs (Server-Type-E21) and one
+TG (Server-Type-E31) connected in a 3-node circular topology
 ([Server Types](#server-types)).
 Used for FD.io performance tests.
 
-### 3-Node-Rangeley Atom Testbeds
+### 3-Node-Altra Arm Ampere (3n-alt)
 
-Each 3-Node-Rangeley testbed includes two SUTs (Server-Type-B5) and one
-TG (Server-Type-2) connected in a 3-node circular topology
+Each 3-Node-Altra testbed includes two SUTs (Server-Type-E23) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+### 3-Node-Icelake Xeon Intel (3n-icx)
+
+Each 3-Node-Icelake testbed includes two SUTs (Server-Type-F1) and one
+TG (Server-Type-F3) connected in a 3-node circular topology
 ([Server Types](#server-types)).
 Used for FD.io performance tests.
 
+### 3-Node-SnowRidge Atom Intel (3n-snr)
+
+Each 3-Node-SnowRidge testbed includes two SUTs (Server-Type-G1) and one
+TG (Server-Type-F4) connected in a 3-node circular topology
+([Server Types](#server-types)).
+Used for FD.io performance tests.
+
+
 ## Server Management
 
 ### Requirements
@@ -233,16 +278,17 @@ Name         | Comment
 10.30.50.13  | LF Reserved
 10.30.50.14  | LF Reserved
 10.30.50.15  | LF Reserved
-10.30.50.28  | s41-nomad
-10.30.50.29  | s39-nomad
-10.30.51.29  | s22-t35-sut1 screen -r /dev/ttyusb0
-10.30.50.30  | s40-nomad
-10.30.51.30  | s23-t35-sut2 screen -r /dev/ttyusb1
-10.30.51.30  | s24-t35-sut3 screen -r /dev/ttyusb2
-10.30.50.32  | s42-nomad
-10.30.50.33  | s43-nomad
-10.30.50.34  | s44-nomad
-10.30.50.35  | s45-nomad
+10.30.50.16  | s16-nomad
+10.30.50.17  | s17-nomad
+10.30.50.18  | s18-nomad
+10.30.50.19  | s19-nomad
+10.30.50.20  | s20-nomad
+10.30.50.21  | s21-nomad
+10.30.50.22  | s22-nomad
+10.30.50.23  | s23-nomad
+10.30.50.24  | s24-nomad
+10.30.50.25  | s25-nomad
+10.30.50.26  | s26-nomad
 10.30.50.36  | s17-t33-sut1
 10.30.50.37  | s18-t33-sut2
 10.30.50.38  | fdio-marvell-dev
@@ -253,7 +299,7 @@ Name         | Comment
 10.30.50.43  | s11-t31-sut1
 10.30.50.44  | s12-t31-sut2
 10.30.50.45  | s13-t31-tg1
-10.30.50.46  | s19-t33t34-tg1
+10.30.50.46  | s19-t33t211-tg1
 10.30.50.47  | s1-t11-sut1
 10.30.50.48  | s2-t12-sut1
 10.30.50.49  | s5-t22-sut1
@@ -271,22 +317,39 @@ Name         | Comment
 10.30.50.66  | s51-nomad
 10.30.50.67  | s49-nomad
 10.30.50.68  | s50-nomad
-10.30.50.69  | s27-t34-sut1
-10.30.50.70  | s55-t36-sut1
-10.30.50.71  | s56-t37-sut1
+10.30.50.69  | s27-t211-sut1
+10.30.50.70  | s55-t13-sut1
+10.30.50.71  | s56-t14-sut1
+10.30.50.72  | s62-t34-sut1
+10.30.50.73  | s63-t34-sut2
+10.30.50.74  | s64-t34-tg1
+10.30.50.75  | s65-t37-sut1
+10.30.50.76  | s66-t37-sut2
+10.30.50.77  | s67-t37-tg1
+10.30.50.78  | s78-t38-sut1
+10.30.50.79  | s79-t38-sut2
+10.30.50.80  | s80-t38-tg1
+10.30.50.81  | s71-t212-sut1
+10.30.50.82  | s72-t212-tg1
+10.30.50.83  | s83-t213-sut1
+10.30.50.84  | s84-t213-tg1
+10.30.50.85  | s85-t214-sut1
+10.30.50.86  | s86-t214-tg1
+10.30.50.87  | s87-t215-sut1
+10.30.50.88  | s88-t215-tg1
+10.30.50.89  | s89-t39t310-tg1
+10.30.50.90  | s90-t311t312-tg1
+10.30.50.91  | s58-nomad
+10.30.50.92  | s59-nomad
+10.30.50.93  | s93-t39-sut1
+10.30.50.94  | s94-t39-sut2
 10.30.50.255 | Broadcast
-n/a          | s20-t34-sut1
-n/a          | s21-t34-sut2
 10.30.55.0   | network
 10.30.55.1   | Router
 10.30.55.10  | s28-t26t35-tg1
 10.30.55.11  | s29-t26-sut1
 10.30.55.12  | s30-t35-sut1
 10.30.55.13  | s31-t35-sut2
-10.30.55.14  | s46-nomad
-10.30.55.15  | s47-nomad
-10.30.55.16  | s48-nomad
-10.30.55.17  | s57-nomad
 10.30.55.18  | s33-t27-sut1
 10.30.55.19  | s34-t27-tg1
 10.30.55.20  | s35-t28-sut1
@@ -299,77 +362,99 @@ n/a          | s21-t34-sut2
 
 ### Management VLAN IP Addresses
 
-Name                      | Comment
-------------------------- | -------
-10.30.51.0                | network
-10.30.51.1                | Router
-10.30.51.2                | LF Reserved
-10.30.51.3                | LF Reserved
-10.30.51.4                | LF Reserved
-10.30.51.5                | LF Reserved
-10.30.51.6                | LF Reserved
-10.30.51.7                | LF Reserved
-10.30.51.8                | LF Reserved
-10.30.51.15               | LF Reserved
-10.30.51.28               | s41-nomad
-10.30.51.29               | s39-nomad
-10.30.51.30               | s40-nomad
-10.30.51.32               | s42-nomad
-10.30.51.33               | s43-nomad
-10.30.51.34               | s44-nomad
-10.30.51.35               | s45-nomad
-10.30.51.36               | s17-t33-sut1
-10.30.51.37               | s18-t33-sut2
-10.30.51.38               | fdio-marvell-dev
-10.30.51.39               | s53-nomad
-10.30.51.40               | s54-nomad
-10.30.51.44               | s3-t21-sut1
-10.30.51.45               | s4-t21-tg1
-10.30.51.46               | s11-t31-sut1
-10.30.51.47               | s12-t31-sut2
-10.30.51.48               | s13-t31-tg1
-10.30.51.49               | s19-t33t34-tg1
-10.30.51.50               | s1-t11-sut1
-10.30.51.51               | s2-t12-sut1
-10.30.51.52               | s5-t22-sut1
-10.30.51.53               | s6-t22-tg1
-10.30.51.54               | s7-t23-sut1
-10.30.51.55               | s8-t23-tg1
-10.30.51.56               | s9-t24-sut1
-10.30.51.57               | s10-t24-tg1
-10.30.51.58               | s14-t32-sut1
-10.30.51.59               | s15-t32-sut2
-10.30.51.60               | s16-t32-tg1
-10.30.51.61               | s25-t25-sut1
-10.30.51.62               | s26-t25-tg1
-10.30.51.65               | s52-nomad
-10.30.51.66               | s51-nomad
-10.30.51.67               | s49-nomad
-10.30.51.68               | s50-nomad
-10.30.51.69               | s27-t34-sut1
-10.30.51.70               | s55-t36-sut1
-10.30.51.71               | s56-t37-sut1
-10.30.51.72-10.30.51.254  | FREE
-10.30.51.255              | Broadcast
-10.32.8.0                 | network
-10.32.8.1                 | Router
-10.32.8.10                | s28-t26t35-tg1
-10.32.8.11                | s29-t26-sut1
-10.32.8.12                | s30-t35-sut1
-10.32.8.13                | s31-t35-sut2
-10.32.8.14                | s46-nomad
-10.32.8.15                | s47-nomad
-10.32.8.16                | s48-nomad
-10.32.8.17                | s57-nomad
-10.32.8.18                | s33-t27-sut1
-10.32.8.19                | s34-t27-tg1
-10.32.8.20                | s35-t28-sut1
-10.32.8.21                | s36-t28-tg1
-10.32.8.22                | s37-t29-sut1
-10.32.8.23                | s38-t29-tg1
-10.32.8.24                | s60-t210-sut1
-10.32.8.25                | s61-t210-tg1
-10.32.8.255               | Broadcast
+Name         | Comment
+-------------| -------
+10.30.51.0   | network
+10.30.51.1   | Router
+10.30.51.2   | LF Reserved
+10.30.51.3   | LF Reserved
+10.30.51.4   | LF Reserved
+10.30.51.5   | LF Reserved
+10.30.51.6   | LF Reserved
+10.30.51.7   | LF Reserved
+10.30.51.8   | LF Reserved
+10.30.51.15  | LF Reserved
+10.30.51.16  | s16-nomad
+10.30.51.17  | s17-nomad
+10.30.51.18  | s18-nomad
+10.30.51.19  | s19-nomad
+10.30.51.20  | s20-nomad
+10.30.51.21  | s21-nomad
+10.30.51.22  | s22-nomad
+10.30.51.23  | s23-nomad
+10.30.51.24  | s24-nomad
+10.30.51.25  | s25-nomad
+10.30.51.26  | s26-nomad
+10.30.51.36  | s17-t33-sut1
+10.30.51.37  | s18-t33-sut2
+10.30.51.38  | fdio-marvell-dev
+10.30.51.39  | s53-nomad
+10.30.51.40  | s54-nomad
+10.30.51.44  | s3-t21-sut1
+10.30.51.45  | s4-t21-tg1
+10.30.51.46  | s11-t31-sut1
+10.30.51.47  | s12-t31-sut2
+10.30.51.48  | s13-t31-tg1
+10.30.51.49  | s19-t33t211-tg1
+10.30.51.50  | s1-t11-sut1
+10.30.51.51  | s2-t12-sut1
+10.30.51.52  | s5-t22-sut1
+10.30.51.53  | s6-t22-tg1
+10.30.51.54  | s7-t23-sut1
+10.30.51.55  | s8-t23-tg1
+10.30.51.56  | s9-t24-sut1
+10.30.51.57  | s10-t24-tg1
+10.30.51.58  | s14-t32-sut1
+10.30.51.59  | s15-t32-sut2
+10.30.51.60  | s16-t32-tg1
+10.30.51.61  | s25-t25-sut1
+10.30.51.62  | s26-t25-tg1
+10.30.51.65  | s52-nomad
+10.30.51.66  | s51-nomad
+10.30.51.67  | s49-nomad
+10.30.51.68  | s50-nomad
+10.30.51.69  | s27-t211-sut1
+10.30.51.70  | s55-t13-sut1
+10.30.51.71  | s56-t14-sut1
+10.30.51.72  | s62-t34-sut1
+10.30.51.73  | s63-t34-sut2
+10.30.51.74  | s64-t34-tg1
+10.30.51.75  | s65-t37-sut1
+10.30.51.76  | s66-t37-sut2
+10.30.51.77  | s67-t37-tg1
+10.30.51.78  | s78-t38-sut1
+10.30.51.79  | s79-t38-sut2
+10.30.51.80  | s80-t38-tg1
+10.30.51.81  | s71-t212-sut1
+10.30.51.82  | s72-t212-tg1
+10.30.51.83  | s83-t213-sut1
+10.30.51.84  | s84-t213-tg1
+10.30.51.85  | s85-t214-sut1
+10.30.51.86  | s86-t214-tg1
+10.30.51.87  | s87-t215-sut1
+10.30.51.88  | s88-t215-tg1
+10.30.51.89  | s89-t39t310-tg1
+10.30.51.90  | s90-t311t312-tg1
+10.30.51.91  | s58-nomad
+10.30.51.92  | s59-nomad
+10.30.51.93  | s93-t39-sut1
+10.30.51.94  | s94-t39-sut2
+10.30.51.255 | Broadcast
+10.32.8.0    | network
+10.32.8.1    | Router
+10.32.8.10   | s28-t26t35-tg1
+10.32.8.11   | s29-t26-sut1
+10.32.8.12   | s30-t35-sut1
+10.32.8.13   | s31-t35-sut2
+10.32.8.18   | s33-t27-sut1
+10.32.8.19   | s34-t27-tg1
+10.32.8.20   | s35-t28-sut1
+10.32.8.21   | s36-t28-tg1
+10.32.8.22   | s37-t29-sut1
+10.32.8.23   | s38-t29-tg1
+10.32.8.24   | s60-t210-sut1
+10.32.8.25   | s61-t210-tg1
+10.32.8.255  | Broadcast
 
 ## Server Specifications
 
@@ -473,20 +558,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-6. Server-Type-B3: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
-    - Quantity: 2
-    - Physical connectivity:
-        - IPMI(?) and host management ports.
-        - NIC ports connected into 3-node topology.
-    - Main HW configuration:
-        - Chassis: Huawei TaiShan 2280.
-        - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
-        - RAM Memory: 8* 16GB DDR4-2400MT/s
-        - Disks: 1* 4TB SATA HDD
-    - NICs configuration:
-        - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
-        - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
-7. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
+6. Server-Type-B5: Purpose - Rangeley Atom SUT for FD.io performance testing.
     - Quantity: TBD based on testbed allocation.
     - Physical connectivity:
         - Management: serial Port (usb) for console
@@ -499,7 +571,7 @@ FD.io CSIT lab contains following server types:
     - NICs configuration:
         - 2x 10Gb Intel 82599ES
         - 4x 1GB Intel I354
-8. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
+7. Server-Type-B6: Purpose - Skylake Xeon SUT for FD.io VPP_Device functional tests.
     - Quantity: 2.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -519,7 +591,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-9. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
+8. Server-Type-B7: Purpose - Ixia PerfectStorm One Appliance TG for FD.io TCP/IP performance tests.
     - Quantity: 1.
     - Physical connectivity:
         - Host management interface: 10/100/1000-BaseT.
@@ -538,7 +610,7 @@ FD.io CSIT lab contains following server types:
         - Port-2: 10GE SFP+.
         - Port-3: 10GE SFP+.
         - Port-4: 10GE SFP+.
-10. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
+9. Server-Type-B8: Purpose - Skylake Xeon SUT for TCP/IP host stack tests.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -558,23 +630,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-11. Server-Type-B9: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
-    - Quantity: 1
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 1-node topologies.
-    - Main HW configuration:
-        - Chassis: Gigabyte R181-T90 1U
-        - Motherboard: MT91-FS1
-        - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
-        - RAM Memory: 4* 32GB RDIMM
-        - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
-    - NICs configuration:
-        - Numa0:
-            - PCIe Slot6 08:00.xx: XL710-QDA2-2p40GE Intel.
-        - Numa1:
-            - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
-12. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
+10. Server-Type-B10: Purpose - Denverton Atom SUT for FD.io performance testing.
     - Quantity: 4
     - Physical connectivity:
         - IPMI and host management ports.
@@ -588,46 +644,7 @@ FD.io CSIT lab contains following server types:
         - 2x 10Gb Intel x553 fiber ports
         - 2x 10Gb Intel x553 copper ports
         - 4x 1GB Intel I350 ports
-13. Server-Type-B11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
-    - Quantity: 2
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 1-node topologies.
-    - Main HW configuration:
-        - Chassis: GIGABYTE Rack Mount
-        - Motherboard: MT91-FS4-00
-        - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
-        - RAM Memory: 16 * 16GB DIMM
-        - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
-    - NICs configuration:
-        - Numa0:
-            - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
-        - Numa1:
-            - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
-14. Server-Type-B12: Purpose - Skylake Xeon TG for FD.io performance testing.
-    - Quantity: ---
-    - Physical connectivity:
-        - IPMI and host management ports.
-        - NIC ports connected into 2-node and 3-node topologies.
-    - Main HW configuration:
-        - Chassis: SuperMicro SYS-7049GP-TRT.
-        - Motherboard: SuperMicro X11DPG-QT.
-        - Processors: 2* Intel Platinum 8180 2.5 GHz.
-        - RAM Memory: 16* 16GB DDR4-2666MHz.
-        - Disks: 2* 1.6TB 6G SATA SSD.
-    - NICs configuration:
-        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
-            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
-            - PCIe Slot9 5e:00.xx: empty.
-        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
-            - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
-
-15. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
+11. Server-Type-C1: Purpose - Cascadelake Xeon SUT for FD.io VPP_Device functional tests.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -647,7 +664,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot6 86:00.xx: empty.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-16. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
+12. Server-Type-C2: Purpose - Cascadelake Xeon SUT for FD.io performance testing.
     - Quantity: 3
     - Physical connectivity:
         - IPMI and host management ports.
@@ -664,10 +681,10 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot4 3b:00.xx: xxv710-DA2-2p25GE Intel.
             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot6 86:00.xx: e810-2p100GE Intel.
             - PCIe Slot8 af:00.xx: empty.
             - PCIe Slot10 d8:00.xx: empty.
-17. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
+13. Server-Type-C3: Purpose - Cascadelake Xeon TG for FD.io performance testing.
     - Quantity: 3.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -684,13 +701,13 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
             - PCIe Slot9 5e:00.xx: ConnectX5-2p100GE Mellanox.
         - Numa1: (x16, x16, x16 PCIe3.0 lanes)
-            - PCIe Slot6 86:00.xx: empty.
-            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot6 86:00.xx: ConnectX5-2p100GE Mellanox.
+            - PCIe Slot8 af:00.xx: ConnectX5-2p100GE Mellanox.
             - PCIe Slot10 d8:00.xx: empty.
-18. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
+14. Server-Type-C4: Purpose - Cascadelake Xeon Backend hosts for FD.io builds and data processing.
     - Quantity: 3.
     - Physical connectivity:
-        - CIMC and host management ports.
+        - IPMI and host management ports.
         - no NIC ports, standalone setup.
     - Main HW configuration:
         - Chassis: SuperMicro 1029P-WTRT.
@@ -703,7 +720,7 @@ FD.io CSIT lab contains following server types:
             - no cards.
         - Numa1:
             - no cards.
-19. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
+15. Server-Type-D1: Purpose - Zen2 EPYC SUT for FD.io performance testing.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -718,7 +735,7 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot1 01:00.xx: x710-4p10GE Intel.
             - PCIe Slot2 41:00.xx: xxv710-DA2-2p25GE Intel.
             - PCIe Slot3 81:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
-20. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
+16. Server-Type-D2: Purpose - Zen2 EPYC TG for FD.io performance testing.
     - Quantity: 1.
     - Physical connectivity:
         - IPMI and host management ports.
@@ -733,6 +750,195 @@ FD.io CSIT lab contains following server types:
             - PCIe Slot1 01:00.xx: mcx556a-edat ConnectX5-2p100GE Mellanox.
             - PCIe Slot2 41:00.xx: x710-4p10GE Intel.
             - PCIe Slot3 81:00.xx: xxv710-DA2 2p25GE Intel.
+17.  Server-Type-E11: Purpose - ThunderX2 Arm Marvell SUT for FD.io VPP_Device functional tests.
+    - Quantity: 2
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 1-node topologies.
+    - Main HW configuration:
+        - Chassis: GIGABYTE Rack Mount
+        - Motherboard: MT91-FS4-00
+        - Processors: 2 * ThunderX2 ARMv8 CN9980 2.20 GHz
+        - RAM Memory: 16 * 16GB DIMM
+        - Disks: 2 * 480GB 6G SATA SSD SAMSUNG MZ7LH480
+    - NICs configuration:
+        - Numa0:
+            - PCIe Slot4 05:00.xx: XL710-QDA2-2p40GE Intel.
+            - PCIe Slot8 0b:00.xx: ConnectX5-2p10/25GE Mellanox.
+        - Numa1:
+            - PCIe Slot14 91:00.xx: XL710-QDA2-2p40GE Intel.
+            - PCIe Slot26 9a:00.xx: ConnectX5-2p10/25GE Mellanox.
+18.  Server-Type-E21: Purpose - TaiShan Arm Huawei SUT for FD.io performance testing.
+    - Quantity: 2
+    - Physical connectivity:
+        - IPMI(?) and host management ports.
+        - NIC ports connected into 3-node topology.
+    - Main HW configuration:
+        - Chassis: Huawei TaiShan 2280.
+        - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72
+        - RAM Memory: 8* 16GB DDR4-2400MT/s
+        - Disks: 1* 4TB SATA HDD
+    - NICs configuration:
+        - PCIe Slot4 e9:00.xx: connectx4-2p25GE Mellanox.
+        - PCIe Slot6 11:00.xx: x520-2p10GE Intel.
+19.  Server-Type-E22: Purpose - ThunderX2 Arm Marvell SUT for FD.io performance testing.
+    - Quantity: 1
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node topologies.
+    - Main HW configuration:
+        - Chassis: Gigabyte R181-T90 1U
+        - Motherboard: MT91-FS1
+        - Processors: 2* ThunderX2 ARMv8 CN9975 2.0 GHz
+        - RAM Memory: 4* 32GB RDIMM
+        - Disks: 1* 480GB SSD Micron, 1* 1000GB HDD Seagate_25
+    - NICs configuration:
+        - Numa0:
+            - no cards
+        - Numa1:
+            - PCIe Slot18 91:00.xx: XL710-QDA2-2p40GE Intel.
+20.  Server-Type-E23: Purpose - Altra Arm Ampere SUT for FD.io performance testing.
+    - Quantity: 2
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-node topologies.
+    - Main HW configuration:
+        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+        - Motherboard: Mt.Jade Motherboard
+        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+        - RAM Memory: 16* 8GB DDR4-3200MT/s
+        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+    - NICs configuration:
+        - Numa0:
+            - PCIe Slot1 0004:04:00.x: xl710-QDA2-2p40GE Intel.
+        - Numa1:
+            - no cards.
+21. Server-Type-E24 : Purpose - Altra Arm Ampere for FD.io build.
+    - Quantity: 2.
+    - Physical connectivity:
+        - IPMI and host management ports.
+    - Main HW configuration:
+        - Chassis: Gigabyte R152-P30-00 1U
+        - Motherboard: MP32-AR1-00
+        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+        - RAM Memory: 12* 16GB DDR4-3200MT/s
+        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
+22.  Server-Type-E31: Purpose - Skylake Xeon TG for FD.io performance testing.
+    - Quantity: 1
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node and 3-node topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-7049GP-TRT.
+        - Motherboard: SuperMicro X11DPG-QT.
+        - Processors: 2* Intel Platinum 8180 2.5 GHz.
+        - RAM Memory: 16* 16GB DDR4-2666MHz.
+        - Disks: 2* 1.6TB 6G SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: x710-4p10GE Intel.
+            - PCIe Slot4 3b:00.xx: xxv710-DA2 2p25GE Intel.
+            - PCIe Slot9 5e:00.xx: empty.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: XL710-QDA2-2p40GE Intel.
+            - PCIe Slot10 d8:00.xx: x710-4p10GE Intel.
+23. Server-Type-F1: Purpose - Icelake Xeon SUT for FD.io performance testing.
+    - Quantity: 8.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node or 3-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-740GP-TNRT.
+        - Motherboard: Super X12DPG-QT6.
+        - Processors: 2* Intel Platinum 8358 2.6 GHz.
+        - RAM Memory: 16* 16GB DDR4-3200.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+24. Server-Type-F2: Purpose - Icelake Xeon TG for FD.io performance testing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-740GP-TNRT.
+        - Motherboard: Super X12DPG-QT6.
+        - Processors: 2* Intel Platinum 8358 2.6 GHz.
+        - RAM Memory: 16* 16GB DDR4-3200.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+25. Server-Type-F3: Purpose - Icelake Xeon TG for FD.io performance testing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-740GP-TNRT.
+        - Motherboard: Super X12DPG-QT6.
+        - Processors: 2* Intel Platinum 8358 2.6 GHz.
+        - RAM Memory: 16* 16GB DDR4-3200.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot4 3b:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot9 5e:00.xx: e810-2CQDA2-2p100GE Intel.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: empty.
+            - PCIe Slot8 af:00.xx: empty.
+            - PCIe Slot10 d8:00.xx: empty.
+26. Server-Type-F4: Purpose - Icelake Xeon Shared TG for FD.io performance testing.
+    - Quantity: 3.
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 2-node and/or 3-node testbed topologies.
+    - Main HW configuration:
+        - Chassis: SuperMicro SYS-740GP-TNRT.
+        - Motherboard: Super X12DPG-QT6.
+        - Processors: 2* Intel Platinum 8358 2.6 GHz.
+        - RAM Memory: 16* 16GB DDR4-3200.
+        - Disks: 2* 960GB SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot2 18:00.xx: xxv710-DA2-2p25GE Intel.
+            - PCIe Slot4 3b:00.xx: empty.
+            - PCIe Slot9 5e:00.xx: empty.
+        - Numa1: (x16, x16, x16 PCIe3.0 lanes)
+            - PCIe Slot6 86:00.xx: e810-XXVDA4-4p25GE Intel.
+            - PCIe Slot8 af:00.xx: e810-2CQDA2-2p100GE Intel.
+            - PCIe Slot10 d8:00.xx: empty.
+27. Server-Type-G1: Purpose - SnowRidge Atom SUT for FD.io performance testing.
+    - Quantity: 2
+    - Physical connectivity:
+        - IPMI and host management ports.
+        - NIC ports connected into 3-node testbed topology.
+    - Main HW configuration:
+        - Chassis: Intel JACOBSVILLE SDP.
+        - Motherboard: Intel JACOBSVILLE E63448-400.
+        - Processors: 1* Intel Atom P5362B 2.2 GHz.
+        - RAM Memory: 2* 16GB DDR4-2933.
+        - Disks: ?* ? SATA SSD.
+    - NICs configuration:
+        - Numa0: (x16, PCIe3.0 lane)
+            - PCIe BuiltIn ec:00.xx: e810-XXVDA4-4p25GE Intel.
 ```
 
 ### Naming Convention
@@ -796,34 +1002,34 @@ connectivity and wiring across defined CSIT testbeds:
 #### 1-Node-ThunderX2 Servers (1n-tx2) PROD
 
 ```
-- SUT [Server-Type-B11]:
-    - testbedname: testbed36
-    - hostname: s55-t36-sut1
+- SUT [Server-Type-E11]:
+    - testbedname: testbed13
+    - hostname: s55-t13-sut1
     - IPMI IP: 10.30.50.70
     - Host IP: 10.30.51.70
     - portnames:
-        - s55-t36-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s55-t36-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s55-t36-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
-        - s55-t36-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-        - s55-t36-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s55-t36-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s55-t36-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
-        - s55-t36-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-- SUT [Server-Type-B11]:
-    - testbedname: testbed37
-    - hostname: s56-t37-sut1
+        - s55-t13-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s55-t13-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+        - s55-t13-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+        - s55-t13-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+        - s55-t13-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s55-t13-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+        - s55-t13-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+        - s55-t13-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+- SUT [Server-Type-E11]:
+    - testbedname: testbed14
+    - hostname: s56-t14-sut1
     - IPMI IP: 10.30.50.71
     - Host IP: 10.30.51.71
     - portnames:
-        - s56-t37-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s56-t37-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s56-t37-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
-        - s56-t37-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
-        - s56-t37-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s56-t37-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
-        - s56-t37-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
-        - s56-t37-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+        - s56-t14-sut1-c4/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s56-t14-sut1-c4/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+        - s56-t14-sut1-c8/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+        - s56-t14-sut1-c8/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
+        - s56-t14-sut1-c14/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s56-t14-sut1-c14/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+        - s56-t14-sut1-c26/p1 - 40GE-port1 ConnectX5-2p10/25GE Mellanox.
+        - s56-t14-sut1-c26/p2 - 40GE-port2 ConnectX5-2p10/25GE Mellanox.
 ```
 
 #### 1-Node-Cascadelake Servers (1n-clx) PROD
@@ -872,6 +1078,10 @@ connectivity and wiring across defined CSIT testbeds:
         - s4-t21-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s4-t21-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s4-t21-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s3-t21-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s3-t21-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s3-t21-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s3-t21-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 - SUT [Server-Type-B1]:
     - testbedname: testbed22.
     - hostname: s5-t22-sut1.
@@ -896,6 +1106,10 @@ connectivity and wiring across defined CSIT testbeds:
         - s6-t22-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s6-t22-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s6-t22-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s6-t22-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s6-t22-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s6-t22-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s6-t22-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 - SUT [Server-Type-B1]:
     - testbedname: testbed23.
     - hostname: s7-t23-sut1.
@@ -920,6 +1134,10 @@ connectivity and wiring across defined CSIT testbeds:
         - s8-t23-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s8-t23-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s8-t23-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s8-t23-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s8-t23-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s8-t23-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s8-t23-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 - SUT [Server-Type-B1]:
     - testbedname: testbed24.
     - hostname: s9-t24-sut1.
@@ -944,6 +1162,10 @@ connectivity and wiring across defined CSIT testbeds:
         - s10-t24-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s10-t24-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s10-t24-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s10-t24-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s10-t24-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s10-t24-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s10-t24-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 ```
 
 #### 2-Node-Denverton Servers (2n-dnv) PROD
@@ -1037,8 +1259,10 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
         - s34-t27-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s34-t27-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s34-t27-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s34-t27-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
-        - s34-t27-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+        - s34-t27-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s34-t27-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s38-t27-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t27-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
         - s34-t27-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
         - s34-t27-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
 - SUT [Server-Type-C2]:
@@ -1069,8 +1293,10 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
         - s36-t28-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s36-t28-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s36-t28-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s36-t28-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
-        - s36-t28-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+        - s36-t28-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s36-t28-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
+        - s38-t28-tg1-c8/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t28-tg1-c8/p2 - 100GE-port2 ConnectX5-2p100GE.
         - s36-t28-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
         - s36-t28-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
 - SUT [Server-Type-C2]:
@@ -1101,8 +1327,8 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
         - s38-t29-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s38-t29-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s38-t29-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s38-t29-tg1-c6/p1 - 100GE-port1 e810-2p100GE.
-        - s38-t29-tg1-c6/p2 - 100GE-port2 e810-2p100GE.
+        - s38-t29-tg1-c6/p1 - 100GE-port1 ConnectX5-2p100GE.
+        - s38-t29-tg1-c6/p2 - 100GE-port2 ConnectX5-2p100GE.
         - s38-t29-tg1-c9/p1 - 100GE-port1 ConnectX5-2p100GE.
         - s38-t29-tg1-c9/p2 - 100GE-port2 ConnectX5-2p100GE.
 ```
@@ -1142,37 +1368,160 @@ Note: ServerB28 (TG) is shared between testbed26 & testbed35
 
 #### 2-Node-ThunderX2 Servers (2x-tx2) PROD
 
-Note: Server19 (TG) is shared between testbed33 & testbed34
+Note: Server19 (TG) is shared between testbed33 & testbed211
 
 ```
-- SUT [Server-Type-B9]:
-    - testbedname: testbed34.
-    - hostname: s27-t34-sut1.
+- SUT [Server-Type-E22]:
+    - testbedname: testbed211.
+    - hostname: s27-t211-sut1.
     - IPMI IP: 10.30.50.69
     - Host IP: 10.30.51.69
     - portnames:
-        - s27-t34-sut1-c6/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t34-sut1-c6/p2 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t34-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
-        - s27-t34-sut1-c18/p2 - 40GE-port1 XL710-QDA2-2p40GE.
-- TG [Server-Type-B12]:
-    - testbedname: testbed33 and testbed34.
-    - hostname: s19-t33t34-tg1.
+        - s27-t211-sut1-c18/p1 - 40GE-port1 XL710-QDA2-2p40GE.
+        - s27-t211-sut1-c18/p2 - 40GE-port2 XL710-QDA2-2p40GE.
+- TG [Server-Type-E31]:
+    - testbedname: testbed33 and testbed211.
+    - hostname: s19-t33t211-tg1.
     - IPMI IP: 10.30.50.46
     - Host IP: 10.30.51.49
     - portnames:
-        - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+        - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
+#### 2-Node-Icelake Servers (2n-icx) PROD
+
+```
+- SUT [Server-Type-F1]:
+    - testbedname: testbed212.
+    - hostname: s71-t212-sut1.
+    - IPMI IP: 10.30.51.81
+    - Host IP: 10.30.50.81
+    - portnames:
+        - s71-t212-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s71-t212-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s71-t212-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s71-t212-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s71-t212-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s71-t212-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s71-t212-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s71-t212-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+    - testbedname: testbed212.
+    - hostname: s72-t212-tg1.
+    - IPMI IP: 10.30.51.82
+    - Host IP: 10.30.50.82
+    - portnames:
+        - s72-t212-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s72-t212-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s72-t212-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s72-t212-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s72-t212-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s72-t212-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s72-t212-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s72-t212-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s72-t212-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s72-t212-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+    - testbedname: testbed213.
+    - hostname: s83-t213-sut1.
+    - IPMI IP: 10.30.51.83
+    - Host IP: 10.30.50.83
+    - portnames:
+        - s83-t213-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s83-t213-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s83-t213-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s83-t213-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s83-t213-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+    - testbedname: testbed213.
+    - hostname: s84-t213-tg1.
+    - IPMI IP: 10.30.51.84
+    - Host IP: 10.30.50.84
+    - portnames:
+        - s84-t213-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s84-t213-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s84-t213-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s84-t213-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s84-t213-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+    - testbedname: testbed214.
+    - hostname: s85-t214-sut1.
+    - IPMI IP: 10.30.51.85
+    - Host IP: 10.30.50.85
+    - portnames:
+        - s85-t214-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s85-t214-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s85-t214-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s85-t214-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s85-t214-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+    - testbedname: testbed214.
+    - hostname: s86-t214-tg1.
+    - IPMI IP: 10.30.51.86
+    - Host IP: 10.30.50.86
+    - portnames:
+        - s86-t214-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s86-t214-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s86-t214-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s86-t214-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s86-t214-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- SUT [Server-Type-F1]:
+    - testbedname: testbed215.
+    - hostname: s87-t215-sut1.
+    - IPMI IP: 10.30.51.87
+    - Host IP: 10.30.50.87
+    - portnames:
+        - s87-t215-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s87-t215-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s87-t215-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s87-t215-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s87-t215-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- TG [Server-Type-F2]:
+    - testbedname: testbed215.
+    - hostname: s88-t215-tg1.
+    - IPMI IP: 10.30.51.88
+    - Host IP: 10.30.50.88
+    - portnames:
+        - s88-t215-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s88-t215-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s88-t215-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s88-t215-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c6/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s88-t215-tg1-c6/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 ```
 
 #### 3-Node-Skylake Servers (3n-skx) PROD
@@ -1190,8 +1539,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s11-t31-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s11-t31-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s11-t31-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s11-t31-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s11-t31-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
 - ServerB12 [Server-Type-B1]:
     - testbedname: testbed31.
     - hostname: s12-t31-sut2.
@@ -1204,8 +1551,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s12-t31-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
         - s12-t31-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s12-t31-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s12-t31-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s12-t31-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
 - ServerB13 [Server-Type-B2]:
     - testbedname: testbed31.
     - hostname: s13-t31-tg1.
@@ -1218,8 +1563,10 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s13-t31-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s13-t31-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s13-t31-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s13-t31-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s13-t31-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+        - s13-t31-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s13-t31-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s13-t31-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s13-t31-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 - ServerB14 [Server-Type-B1]:
     - testbedname: testbed32.
     - hostname: s14-t32-sut1.
@@ -1232,8 +1579,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s14-t32-sut1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s14-t32-sut1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s14-t32-sut1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s14-t32-sut1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s14-t32-sut1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
 - ServerB15 [Server-Type-B1]:
     - testbedname: testbed32.
     - hostname: s15-t32-sut2.
@@ -1246,8 +1591,6 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s15-t32-sut2-c2/p4 - 10GE-port4 x710-4p10GE.
         - s15-t32-sut2-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s15-t32-sut2-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s15-t32-sut2-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s15-t32-sut2-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
 - ServerB16 [Server-Type-B2]:
     - testbedname: testbed32.
     - hostname: s16-t32-tg1.
@@ -1260,8 +1603,10 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s16-t32-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
         - s16-t32-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
         - s16-t32-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s16-t32-tg1-c9/p1 - FUTURE 100GE-port1 ConnectX5-2p100GE.
-        - s16-t32-tg1-c9/p2 - FUTURE 100GE-port2 ConnectX5-2p100GE.
+        - s16-t32-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s16-t32-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s16-t32-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s16-t32-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
 ```
 
 #### 3-Node-Rangeley Servers (3n-rng) VERIFY
@@ -1300,10 +1645,10 @@ Note: There is no IPMI. Serial console is accessible via VIRL2 and VIRL3 USB.
 
 #### 3-Node-Taishan Servers (3n-tsh) PROD
 
-Note: Server19 (TG) is shared between testbed33 & testbed34
+Note: Server19 (TG) is shared between testbed33 & testbed211
 
 ```
-- SUT [Server-Type-B3]:
+- SUT [Server-Type-E21]:
     - testbedname: testbed33.
     - hostname: s17-t33-sut1.
     - IPMI IP: 10.30.50.36
@@ -1313,7 +1658,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s17-t33-sut1-c6/p2 - 10GE-port2 x520-2p10GE.
         - s17-t33-sut1-c4/p1 - 25GE-port1 cx4-2p25GE.
         - s17-t33-sut1-c4/p2 - 25GE-port2 cx4-2p25GE.
-- SUT [Server-Type-B3]:
+- SUT [Server-Type-E21]:
     - testbedname: testbed33.
     - hostname: s18-t33-sut2.
     - IPMI IP: 10.30.50.37
@@ -1323,24 +1668,61 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s18-t33-sut2-c6/p2 - 10GE-port2 x520-2p10GE.
         - s18-t33-sut2-c4/p1 - 25GE-port1 cx4-2p25GE.
         - s18-t33-sut2-c4/p2 - 25GE-port2 cx4-2p25GE.
-- TG [Server-Type-B12]:
-    - testbedname: testbed33 and testbed34.
-    - hostname: s19-t33t34-tg1.
+- TG [Server-Type-E31]:
+    - testbedname: testbed33 and testbed211.
+    - hostname: s19-t33t211-tg1.
     - IPMI IP: 10.30.50.46
     - Host IP: 10.30.51.49
     - portnames:
-        - s19-t33t34-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t34-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
-        - s19-t33t34-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
-        - s19-t33t34-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
-        - s19-t33t34-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s19-t33t34-tg1-c8/p2 - 40GE-port1 xl710-QDA2-2p40GE.
-        - s19-t33t34-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
-        - s19-t33t34-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p1 - 10GE-port1 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p2 - 10GE-port2 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p3 - 10GE-port3 x710-4p10GE.
+        - s19-t33t211-tg1-c2/p4 - 10GE-port4 x710-4p10GE.
+        - s19-t33t211-tg1-c4/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s19-t33t211-tg1-c4/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s19-t33t211-tg1-c8/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s19-t33t211-tg1-c8/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+        - s19-t33t211-tg1-c10/p1 - 10GE-port1 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p2 - 10GE-port2 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p3 - 10GE-port3 x710-4p10GE.
+        - s19-t33t211-tg1-c10/p4 - 10GE-port4 x710-4p10GE.
+```
+
+#### 3-Node-Altra Servers (3n-alt) PROD
+
+```
+- SUT [Server-Type-E23]:
+    - testbedname: testbed34.
+    - hostname: s62-t34-sut1.
+    - IPMI IP: 10.30.50.72
+    - Host IP: 10.30.51.72
+    - portnames:
+        - s62-t34-sut1-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s62-t34-sut1-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- SUT [Server-Type-E23]:
+    - testbedname: testbed34.
+    - hostname: s63-t34-sut2.
+    - IPMI IP: 10.30.50.73
+    - Host IP: 10.30.51.73
+    - portnames:
+        - s63-t34-sut2-c1/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s63-t34-sut2-c1/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+- TG [Server-Type-F4]:
+    - testbedname: testbed34.
+    - hostname: s64-t34-tg1.
+    - IPMI IP: 10.30.50.74
+    - Host IP: 10.30.51.74
+    - portnames:
+        - s64-t34-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s64-t34-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s64-t34-tg1-c4/p1 - 40GE-port1 xl710-QDA2-2p40GE.
+        - s64-t34-tg1-c4/p2 - 40GE-port2 xl710-QDA2-2p40GE.
+        - s64-t34-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s64-t34-tg1-c8/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s64-t34-tg1-c8/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
 ```
 
 #### 3-Node-Denverton Servers (3n-dnv) PROD
@@ -1368,6 +1750,130 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s31-t35-sut2-p4 - 10GE-port4 x553 fiber port.
 ```
 
+#### 3-Node-Icelake Servers (3n-icx) PROD
+
+```
+- ServerF1 [Server-Type-F1]:
+    - testbedname: testbed37.
+    - hostname: s65-t37-sut1.
+    - IPMI IP: 10.30.50.75
+    - Host IP: 10.30.51.75
+    - portnames:
+        - s65-t37-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s65-t37-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s65-t37-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s65-t37-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s65-t37-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s65-t37-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s65-t37-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s65-t37-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+    - testbedname: testbed37.
+    - hostname: s66-t37-sut2.
+    - IPMI IP: 10.30.50.76
+    - Host IP: 10.30.51.76
+    - portnames:
+        - s66-t37-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s66-t37-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s66-t37-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s66-t37-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s66-t37-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s66-t37-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s66-t37-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s66-t37-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+    - testbedname: testbed37.
+    - hostname: s67-t37-tg1.
+    - IPMI IP: 10.30.50.77
+    - Host IP: 10.30.51.77
+    - portnames:
+        - s67-t37-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s67-t37-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s67-t37-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s67-t37-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s67-t37-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s67-t37-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s67-t37-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s67-t37-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+    - testbedname: testbed38.
+    - hostname: s78-t38-sut1.
+    - IPMI IP: 10.30.50.78
+    - Host IP: 10.30.51.78
+    - portnames:
+        - s78-t38-sut1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s78-t38-sut1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s78-t38-sut1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s78-t38-sut1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s78-t38-sut1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF1 [Server-Type-F1]:
+    - testbedname: testbed38.
+    - hostname: s79-t38-sut2.
+    - IPMI IP: 10.30.50.79
+    - Host IP: 10.30.51.79
+    - portnames:
+        - s79-t38-sut2-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s79-t38-sut2-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s79-t38-sut2-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s79-t38-sut2-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s79-t38-sut2-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+- ServerF3 [Server-Type-F3]:
+    - testbedname: testbed38.
+    - hostname: s80-t38-tg1.
+    - IPMI IP: 10.30.50.80
+    - Host IP: 10.30.51.80
+    - portnames:
+        - s80-t38-tg1-c2/p1 - 25GE-port1 xxv710-DA2-2p25GE.
+        - s80-t38-tg1-c2/p2 - 25GE-port2 xxv710-DA2-2p25GE.
+        - s80-t38-tg1-c4/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c4/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c4/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c4/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+        - s80-t38-tg1-c9/p1 - 100GE-port1 e810-2CQDA2-2p100GE.
+        - s80-t38-tg1-c9/p2 - 100GE-port2 e810-2CQDA2-2p100GE.
+```
+
+#### 3-Node-SnowRidge Servers (3n-snr) PROD
+
+```
+- ServerG1 [Server-Type-G1]:
+    - testbedname: testbed39.
+    - hostname: s93-t39-sut1.
+    - IPMI IP: 10.30.50.93
+    - Host IP: 10.30.51.93
+    - portnames:
+        - s93-t39-sut1-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s93-t39-sut1-c1/p2 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerG1 [Server-Type-G1]:
+    - testbedname: testbed39.
+    - hostname: s94-t39-sut2.
+    - IPMI IP: 10.30.50.94
+    - Host IP: 10.30.51.94
+    - portnames:
+        - s94-t39-sut2-c1/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s94-t39-sut2-c1/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+- ServerF4 [Server-Type-F4]:
+    - testbedname: testbed39.
+    - hostname: s89-t39t310-tg1.
+    - IPMI IP: 10.30.50.89
+    - Host IP: 10.30.51.89
+    - portnames:
+        - s89-t39t310-tg1-c6/p1 - 25GE-port1 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p2 - 25GE-port2 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p3 - 25GE-port3 e810-XXVDA4-4p25GE.
+        - s89-t39t310-tg1-c6/p4 - 25GE-port4 e810-XXVDA4-4p25GE.
+```
+
 ### Per Testbed Wiring
 
 #### 1-Node-Skylake Wiring (1n-skx) PROD
@@ -1381,7 +1887,11 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
     - ring3 10GE-ports x710-4p10GE:
         - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
     - ring4 10GE-ports x710-4p10GE:
-        - s1-t11-sut1-c2/p3 to s1-t11-sut1-c4/p3.
+        - s1-t11-sut1-c2/p4 to s1-t11-sut1-c4/p4.
+    - ring5 100GE-ports e810-2p100GE:
+        - s1-t11-sut1-c5/p1 to s1-t11-sut1-c6/p1.
+    - ring6 100GE-ports e810-2p100GE:
+        - s1-t11-sut1-c5/p2 to s1-t11-sut1-c6/p2.
 - testbed12:
     - ring1 10GE-ports x710-4p10GE:
         - s2-t12-sut1-c2/p1 to s2-t12-sut1-c4/p1.
@@ -1390,45 +1900,35 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
     - ring3 10GE-ports x710-4p10GE:
         - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
     - ring4 10GE-ports x710-4p10GE:
-        - s2-t12-sut1-c2/p3 to s2-t12-sut1-c4/p3.
+        - s2-t12-sut1-c2/p4 to s2-t12-sut1-c4/p4.
+    - ring5 100GE-ports e810-2p100GE:
+        - s2-t12-sut1-c5/p1 to s2-t12-sut1-c6/p1.
+    - ring6 100GE-ports e810-2p100GE:
+        - s2-t12-sut1-c5/p2 to s2-t12-sut1-c6/p2.
 ```
 
 #### 1-Node-ThunderX2 Wiring (1n-tx2) PROD
 
 ```
-- testbed36:
+- testbed13:
     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s55-t36-sut1-c4/p1 - s55-t36-sut1-c14/p1.
+        - s55-t13-sut1-c4/p1 - s55-t13-sut1-c14/p1.
     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s55-t36-sut1-c4/p2 - s55-t36-sut1-c14/p2.
+        - s55-t13-sut1-c4/p2 - s55-t13-sut1-c14/p2.
     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
-        - s55-t36-sut1-c8/p1 - s55-t36-sut1-c26/p1.
+        - s55-t13-sut1-c8/p1 - s55-t13-sut1-c26/p1.
     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
-        - s55-t36-sut1-c8/p2 - s55-t36-sut1-c26/p2.
+        - s55-t13-sut1-c8/p2 - s55-t13-sut1-c26/p2.
 
-- testbed37:
+- testbed14:
     - ring1 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s56-t37-sut1-c4/p1 - s56-t37-sut1-c14/p1.
+        - s56-t14-sut1-c4/p1 - s56-t14-sut1-c14/p1.
     - ring2 40GE-ports XL710-QDA2-2p40GE on SUTs:
-        - s56-t37-sut1-c4/p2 - s56-t37-sut1-c14/p2.
+        - s56-t14-sut1-c4/p2 - s56-t14-sut1-c14/p2.
     - ring3 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
-        - s55-t37-sut1-c8/p1 - s55-t37-sut1-c26/p1.
+        - s56-t14-sut1-c8/p1 - s56-t14-sut1-c26/p1.
     - ring4 10/25GE-ports ConnectX5-2p10/25GE on SUTs:
-        - s55-t37-sut1-c8/p2 - s55-t37-sut1-c26/p2.
-```
-
-#### 1-Node-Cascadelake Wiring (1n-clx) PROD
-
-```
-- testbed14:
-    - ring1 10GE-ports x710-4p10GE:
-        - s32-t14-sut1-c2/p1 to s32-t14-sut1-c4/p1.
-    - ring2 10GE-ports x710-4p10GE:
-        - s32-t14-sut1-c2/p2 to s32-t14-sut1-c4/p2.
-    - ring3 10GE-ports x710-4p10GE:
-        - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
-    - ring4 10GE-ports x710-4p10GE:
-        - s32-t14-sut1-c2/p3 to s32-t14-sut1-c4/p3.
+        - s56-t14-sut1-c8/p2 - s56-t14-sut1-c26/p2.
 ```
 
 #### 2-Node-Skylake Wiring (2n-skx) PROD
@@ -1444,6 +1944,9 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s4-t21-tg1-c4/p1 to s3-t21-sut1-c4/p1.
         - s3-t21-sut1-c4/p2 to s4-t21-tg1-c4/p2.
+    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+        - s4-t21-tg1-c10/p1 to s4-t21-tg1-c10/p2.
+        - s4-t21-tg1-c10/p3 to s4-t21-tg1-c10/p4.
 - testbed22:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s6-t22-tg1-c2/p1 to s5-t22-sut1-c2/p1.
@@ -1454,6 +1957,9 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s6-t22-tg1-c4/p1 to s5-t22-sut1-c4/p1.
         - s5-t22-sut1-c4/p2 to s6-t22-tg1-c4/p2.
+    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+        - s6-t22-tg1-c10/p1 to s6-t22-tg1-c10/p2.
+        - s6-t22-tg1-c10/p3 to s6-t22-tg1-c10/p4.
 - testbed23:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s8-t23-tg1-c2/p1 to s7-t23-sut1-c2/p1.
@@ -1464,6 +1970,9 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s8-t23-tg1-c4/p1 to s7-t23-sut1-c4/p1.
         - s7-t23-sut1-c4/p2 to s8-t23-tg1-c4/p2.
+    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+        - s8-t23-tg1-c10/p1 to s8-t23-tg1-c10/p2.
+        - s8-t23-tg1-c10/p3 to s8-t23-tg1-c10/p4.
 - testbed24:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s10-t24-tg1-c2/p1 to s9-t24-sut1-c2/p1.
@@ -1474,6 +1983,9 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
     - ring3 25GE-ports xxv710-DA2-2p25GE on SUT
         - s10-t24-tg1-c4/p1 to s9-t24-sut1-c4/p1.
         - s9-t24-sut1-c4/p2 to s10-t24-tg1-c4/p2.
+    - ring4 10GE-ports x710-4p10GE loopbacks on TG for self-tests:
+        - s10-t24-tg1-c10/p1 to s10-t24-tg1-c10/p2.
+        - s10-t24-tg1-c10/p3 to s10-t24-tg1-c10/p4.
 ```
 
 #### 2-Node-Denverton Wiring (2n-dnv) PROD
@@ -1518,9 +2030,12 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
         - s34-t27-tg1-c9/p1 to s33-t27-sut1-c9/p1.
         - s33-t27-sut1-c9/p2 to s34-t27-tg1-c9/p2.
-    - ring5 100GE-ports e810-2p100GE on SUT:
+    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
         - s34-t27-tg1-c6/p1 to s33-t27-sut1-c6/p1.
         - s33-t27-sut1-c6/p2 to s34-t27-tg1-c6/p2.
+    - ring6 100GE-ports e810-2p100GE on TG:
+        - s34-t27-tg1-c8/p1 to s34-t27-tg1-c8/p2.
+        - s34-t27-tg1-c8/p2 to s34-t27-tg1-c8/p1.
 - testbed28:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s36-t28-tg1-c2/p1 to s35-t28-sut1-c2/p1.
@@ -1534,9 +2049,12 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
         - s36-t28-tg1-c9/p1 to s35-t28-sut1-c9/p1.
         - s35-t28-sut1-c9/p2 to s36-t28-tg1-c9/p2.
-    - ring5 100GE-ports e810-2p100GE on SUT:
+    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
         - s36-t28-tg1-c6/p1 to s35-t28-sut1-c6/p1.
         - s35-t28-sut1-c6/p2 to s36-t28-tg1-c6/p2.
+    - ring6 100GE-ports e810-2p100GE on TG:
+        - s36-t28-tg1-c8/p1 to s36-t28-tg1-c8/p2.
+        - s36-t28-tg1-c8/p2 to s36-t28-tg1-c8/p1.
 - testbed29:
     - ring1 10GE-ports x710-4p10GE on SUT:
         - s38-t29-tg1-c2/p1 to s37-t29-sut1-c2/p1.
@@ -1550,7 +2068,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
     - ring4 100GE-ports ConnectX5-2p100GE on SUT:
         - s38-t29-tg1-c9/p1 to s37-t29-sut1-c9/p1.
         - s37-t29-sut1-c9/p2 to s38-t29-tg1-c9/p2.
-    - ring6 100GE-ports e810-2p100GE on SUT:
+    - ring5 100GE-ports e810-2p100GE on SUT 100GE-ports ConnectX5-2p100GE on TG:
         - s38-t29-tg1-c6/p1 to s37-t29-sut1-c6/p1.
         - s37-t29-sut1-c6/p2 to s38-t29-tg1-c6/p2.
 ```
@@ -1576,10 +2094,75 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
 #### 2-Node-ThunderX2 Wiring (2n-tx2) PROD
 
 ```
-- testbed34:
+- testbed211:
     - ring1 10GE-ports x520-2p10GE on SUTs:
-        - s27-t34-sut1-c18/p1 - s19-t33t34-tg1-c8/p1.
-        - s27-t34-sut1-c18/p2 - s19-t33t34-tg1-c8/p2.
+        - s27-t211-sut1-c18/p1 - s19-t33t211-tg1-c8/p1.
+        - s27-t211-sut1-c18/p2 - s19-t33t211-tg1-c8/p2.
+```
+
+#### 2-Node-Icelake Wiring (2n-icx) PROD
+
+```
+- testbed212:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s72-t212-tg1-c2/p1 to s71-t212-sut1-c2/p1.
+        - s71-t212-sut1-c2/p2 to s72-t212-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+        - s72-t212-tg1-c4/p1 to s71-t212-sut1-c4/p1.
+        - s71-t212-sut1-c4/p2 to s72-t212-tg1-c4/p2.
+        - s72-t212-tg1-c4/p3 to s71-t212-sut1-c4/p3.
+        - s71-t212-sut1-c4/p4 to s72-t212-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s72-t212-tg1-c9/p1 to s71-t212-sut1-c9/p1.
+        - s71-t212-sut1-c9/p2 to s72-t212-tg1-c9/p2.
+    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s72-t212-tg1-c6/p1 to s72-t212-tg1-c6/p2.
+        - s72-t212-tg1-c6/p2 to s72-t212-tg1-c6/p1.
+- testbed213:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s84-t213-tg1-c2/p1 to s83-t213-sut1-c2/p1.
+        - s83-t213-sut1-c2/p2 to s84-t213-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+        - s84-t213-tg1-c4/p1 to s83-t213-sut1-c4/p1.
+        - s83-t213-sut1-c4/p2 to s84-t213-tg1-c4/p2.
+        - s84-t213-tg1-c4/p3 to s83-t213-sut1-c4/p3.
+        - s83-t213-sut1-c4/p4 to s84-t213-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s84-t213-tg1-c9/p1 to s83-t213-sut1-c9/p1.
+        - s83-t213-sut1-c9/p2 to s84-t213-tg1-c9/p2.
+    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s84-t213-tg1-c6/p1 to s84-t213-tg1-c6/p2.
+        - s84-t213-tg1-c6/p2 to s84-t213-tg1-c6/p1.
+- testbed214:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s86-t214-tg1-c2/p1 to s85-t214-sut1-c2/p1.
+        - s85-t214-sut1-c2/p2 to s86-t214-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+        - s86-t214-tg1-c4/p1 to s85-t214-sut1-c4/p1.
+        - s85-t214-sut1-c4/p2 to s86-t214-tg1-c4/p2.
+        - s86-t214-tg1-c4/p3 to s85-t214-sut1-c4/p3.
+        - s85-t214-sut1-c4/p4 to s86-t214-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s86-t214-tg1-c9/p1 to s85-t214-sut1-c9/p1.
+        - s85-t214-sut1-c9/p2 to s86-t214-tg1-c9/p2.
+    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s86-t214-tg1-c6/p1 to s86-t214-tg1-c6/p2.
+        - s86-t214-tg1-c6/p2 to s86-t214-tg1-c6/p1.
+- testbed215:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUT
+        - s88-t215-tg1-c2/p1 to s87-t215-sut1-c2/p1.
+        - s87-t215-sut1-c2/p2 to s88-t215-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-2p25GE on SUT:
+        - s88-t215-tg1-c4/p1 to s87-t215-sut1-c4/p1.
+        - s87-t215-sut1-c4/p2 to s88-t215-tg1-c4/p2.
+        - s88-t215-tg1-c4/p3 to s87-t215-sut1-c4/p3.
+        - s87-t215-sut1-c4/p4 to s88-t215-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s88-t215-tg1-c9/p1 to s87-t215-sut1-c9/p1.
+        - s87-t215-sut1-c9/p2 to s88-t215-tg1-c9/p2.
+    - ring4 100GE-ports e810-2CQDA2-2p100GE on SUT:
+        - s88-t215-tg1-c6/p1 to s88-t215-tg1-c6/p2.
+        - s88-t215-tg1-c6/p2 to s88-t215-tg1-c6/p1.
 ```
 
 #### 3-Node-Skylake Wiring (3n-skx) PROD
@@ -1627,7 +2210,7 @@ Note: Server19 (TG) is shared between testbed33 & testbed34
         - s16-t32-tg1-c10/p3 to s16-t32-tg1-c10/p4.
 ```
 
-#### 3-Node-Rangeley Wiring (3n-rng) TODO
+#### 3-Node-Rangeley Wiring (3n-rng) VERIFY
 
 ```
 To be completed.
@@ -1638,13 +2221,23 @@ To be completed.
 ```
 - testbed33:
     - ring1 10GE-ports x520-2p10GE on SUTs:
-        - s19-t33t34-tg1-c2/p2 - s17-t33-sut1-c6/p2.
+        - s19-t33t211-tg1-c2/p2 - s17-t33-sut1-c6/p2.
         - s17-t33-sut1-c6/p1 - s18-t33-sut2-c6/p2.
-        - s18-t33-sut2-c6/p1 - s19-t33t34-tg1-c2/p1.
+        - s18-t33-sut2-c6/p1 - s19-t33t211-tg1-c2/p1.
     - ring2 25GE-ports cx4-2p25GE on SUTs:
-        - s19-t33t34-tg1-c4/p2 - s17-t33-sut1-c4/p2.
+        - s19-t33t211-tg1-c4/p2 - s17-t33-sut1-c4/p2.
         - s17-t33-sut1-c4/p1 - s18-t33-sut2-c4/p2.
-        - s18-t33-sut2-c4/p1 - s19-t33t34-tg1-c4/p1.
+        - s18-t33-sut2-c4/p1 - s19-t33t211-tg1-c4/p1.
+```
+
+#### 3-Node-Altra Wiring (3n-alt) PROD
+
+```
+- testbed34:
+    - ring1 40GE-ports xl710-QDA2-2p40GE on SUTs:
+        - s64-t34-tg1-c4/p1 - s62-t34-sut1-c1/p2.
+        - s62-t34-sut1-c1/p1 - s63-t34-sut2-c1/p2.
+        - s63-t34-sut2-c1/p1 - s64-t34-tg1-c4/p2.
 ```
 
 #### 3-Node-Denverton Wiring (3n-dnv) PROD
@@ -1661,6 +2254,56 @@ To be completed.
         - s28-t26t35-tg1-c6/p2 to s31-t35-sut2-p4.
 ```
 
+#### 3-Node-Icelake Wiring (3n-icx) PROD
+
+```
+- testbed37:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+        - s67-t37-tg1-c2/p1 to s65-t37-sut1-c2/p1.
+        - s65-t37-sut1-c2/p2 to s66-t37-sut2-c2/p2.
+        - s66-t37-sut2-c2/p1 to s67-t37-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+        - s67-t37-tg1-c4/p1 to s65-t37-sut1-c4/p1.
+        - s65-t37-sut1-c4/p2 to s66-t37-sut2-c4/p2.
+        - s66-t37-sut2-c4/p1 to s67-t37-tg1-c4/p2.
+        - s67-t37-tg1-c4/p3 to s65-t37-sut1-c4/p3.
+        - s65-t37-sut1-c4/p4 to s66-t37-sut2-c4/p4.
+        - s66-t37-sut2-c4/p3 to s67-t37-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+        - s67-t37-tg1-c9/p1 to s65-t37-sut1-c9/p1.
+        - s65-t37-sut1-c9/p2 to s66-t37-sut2-c9/p2.
+        - s66-t37-sut2-c9/p1 to s67-t37-tg1-c9/p2.
+- testbed38:
+    - ring1 25GE-ports xxv710-DA2-2p25GE on SUTs:
+        - s80-t38-tg1-c2/p1 to s78-t38-sut1-c2/p1.
+        - s78-t38-sut1-c2/p2 to s79-t38-sut2-c2/p2.
+        - s79-t38-sut2-c2/p1 to s80-t38-tg1-c2/p2.
+    - ring2 25GE-ports e810-XXVDA4-4p25GE on SUT:
+        - s80-t38-tg1-c4/p1 to s78-t38-sut1-c4/p1.
+        - s78-t38-sut1-c4/p2 to s79-t38-sut2-c4/p2.
+        - s79-t38-sut2-c4/p1 to s80-t38-tg1-c4/p2.
+        - s80-t38-tg1-c4/p3 to s78-t38-sut1-c4/p3.
+        - s78-t38-sut1-c4/p4 to s79-t38-sut2-c4/p4.
+        - s79-t38-sut2-c4/p3 to s80-t38-tg1-c4/p4.
+    - ring3 100GE-ports e810-2CQDA2-2p100GE on SUT
+        - s80-t38-tg1-c9/p1 to s78-t38-sut1-c9/p1.
+        - s78-t38-sut1-c9/p2 to s79-t38-sut2-c9/p2.
+        - s79-t38-sut2-c9/p1 to s80-t38-tg1-c9/p2.
+```
+
+#### 3-Node-SnowRidge Wiring (3n-snr) PROD
+
+```
+- testbed39:
+    - ring1 25GE-ports e810-XXVDA4-4p25GE on SUTs and TG:
+        - s89-t39t310-tg1-c6/p1 to s93-t39-sut1-c1/p1.
+        - s93-t39-sut1-c1/p2 to s94-t39-sut2-c1/p2.
+        - s94-t39-sut2-c1/p1 to s89-t39t310-tg1-c6/p2.
+        - s89-t39t310-tg1-c6/p3 to s93-t39-sut1-c1/p3.
+        - s93-t39-sut1-c1/p4 to s94-t39-sut2-c1/p4.
+        - s94-t39-sut2-c1/p3 to s89-t39t310-tg1-c6/p4.
+```
+
 ## Inventory
 
 ### Appliances
@@ -1678,7 +2321,7 @@ To be completed.
         - Operating System: Native IxOS.
 ```
 
-### Arm Servers
+### Arm Servers
 
 ```
 1. Arm Cortex A-72 servers
@@ -1697,6 +2340,20 @@ To be completed.
         - Processors: 2* hip07-d05 ~ 32* Arm Cortex-A72.
         - RAM Memory: 8* 16GB DDR4-2400MT/s.
         - Disks: 1* 4TB SATA HDD.
+2. Arm Neoverse N1 servers
+    - 2 * Ampere Altra (Performance)
+        - Chassis: WIWYNN Mt.Jade Server System B81.030Z1.0007 2U
+        - Processors: 2* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x41, Variant 0x3, Architecture 15, Part 0xd0c, Revision 1
+        - RAM Memory: 16* 8GB DDR4-3200MT/s
+        - Disks: 2* 960GB SSD Samsung M.2 NVMe PM983
+    - 2 * Ampere Altra (Build)
+        - Chassis: Gigabyte R152-P30-00 1U
+        - Motherboard: MP32-AR1-00
+        - Processors: 1* Ampere(R) Altra(R) Q80-30 Processor (Neoverse N1)
+        - Processor Signature: Implementor 0x0a, Variant 0x1, Architecture 6, Part 0x000, Revision 1
+        - RAM Memory: 12* 16GB DDR4-3200MT/s
+        - Disks: 1* 960GB SSD Samsung M.2 NVMe PM983
 ```
 
 ### Xeon and Atom Servers
@@ -1721,15 +2378,13 @@ To be completed.
 
 ```
 1. 10GE NICs
-    - 14 * Intel® Ethernet Converged Network Adapter X710-DA4
-    - 6 * Intel® Ethernet Converged Network Adapter X710-DA2
-    - 6 * Intel® Ethernet Converged Network Adapter X520-DA2
+    - ?
 2. 25GE NICs
-    - 12 * Intel® Ethernet Network Adapter XXV710-DA2
+    - ?
 3. 40GE NICs
-    - 2 * Intel® Ethernet Converged Network Adapter XL710-QDA2
+    - ?
 4. 100GE NICs
-    - 4 * mcx556a-edat NICs (not on site yet, in transit)
+    - ?
 ```
 
 ### Pluggables and Cables
@@ -1738,27 +2393,26 @@ Pluggables:
 
 ```
 1. 10GE SFP+
-    - 16 * Intel E10GSFPSR Ethernet SFP+ SR Optics
-    - 80 * 10G SR optic (generic, "Intel" compatible branded)
+    - ?
 2. 25GE SFP28
-    - None
+    - ?
 3. 40GE QSFP+
-    - None
+    - ?
 4. 100GE
-    - 8 * mcp1600-c002 qsfp28 pluggables and cables (not on site yet, in transit)
+    - ?
 ```
 
 Standalone cables:
 
 ```
 1. 10GE
-    - None
+    - ?
 2. 25GE
-    - None
+    - ?
 3. 40GE QSFP+
-    - 20 * Intel XLDACBL5 40G QSFP+ Passive DAC Cable
+    - ?
 4. 100GE
-    - None
+    - ?
 ```
 
 ### Other Parts