New upstream version 18.02
[deb_dpdk.git] / doc / guides / nics / enic.rst
1 ..  BSD LICENSE
2     Copyright (c) 2017, Cisco Systems, Inc.
3     All rights reserved.
4
5     Redistribution and use in source and binary forms, with or without
6     modification, are permitted provided that the following conditions
7     are met:
8
9     1. Redistributions of source code must retain the above copyright
10     notice, this list of conditions and the following disclaimer.
11
12     2. Redistributions in binary form must reproduce the above copyright
13     notice, this list of conditions and the following disclaimer in
14     the documentation and/or other materials provided with the
15     distribution.
16
17     THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
18     "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
19     LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS
20     FOR A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE
21     COPYRIGHT HOLDER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT,
22     INCIDENTAL, SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING,
23     BUT NOT LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES;
24     LOSS OF USE, DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER
25     CAUSED AND ON ANY THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT
26     LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN
27     ANY WAY OUT OF THE USE OF THIS SOFTWARE, EVEN IF ADVISED OF THE
28     POSSIBILITY OF SUCH DAMAGE.
29
30 ENIC Poll Mode Driver
31 =====================
32
33 ENIC PMD is the DPDK poll-mode driver for the Cisco System Inc. VIC Ethernet
34 NICs. These adapters are also referred to as vNICs below. If you are running
35 or would like to run DPDK software applications on Cisco UCS servers using
36 Cisco VIC adapters the following documentation is relevant.
37
38 How to obtain ENIC PMD integrated DPDK
39 --------------------------------------
40
41 ENIC PMD support is integrated into the DPDK suite. dpdk-<version>.tar.gz
42 should be downloaded from http://dpdk.org
43
44
45 Configuration information
46 -------------------------
47
48 - **DPDK Configuration Parameters**
49
50   The following configuration options are available for the ENIC PMD:
51
52   - **CONFIG_RTE_LIBRTE_ENIC_PMD** (default y): Enables or disables inclusion
53     of the ENIC PMD driver in the DPDK compilation.
54
55 - **vNIC Configuration Parameters**
56
57   - **Number of Queues**
58
59     The maximum number of receive queues (RQs), work queues (WQs) and
60     completion queues (CQs) are configurable on a per vNIC basis
61     through the Cisco UCS Manager (CIMC or UCSM).
62
63     These values should be configured as follows:
64
65     - The number of WQs should be greater or equal to the value of the
66       expected nb_tx_q parameter in the call to
67       rte_eth_dev_configure()
68
69     - The number of RQs configured in the vNIC should be greater or
70       equal to *twice* the value of the expected nb_rx_q parameter in
71       the call to rte_eth_dev_configure().  With the addition of Rx
72       scatter, a pair of RQs on the vnic is needed for each receive
73       queue used by DPDK, even if Rx scatter is not being used.
74       Having a vNIC with only 1 RQ is not a valid configuration, and
75       will fail with an error message.
76
77     - The number of CQs should set so that there is one CQ for each
78       WQ, and one CQ for each pair of RQs.
79
80     For example: If the application requires 3 Rx queues, and 3 Tx
81     queues, the vNIC should be configured to have at least 3 WQs, 6
82     RQs (3 pairs), and 6 CQs (3 for use by WQs + 3 for use by the 3
83     pairs of RQs).
84
85   - **Size of Queues**
86
87     Likewise, the number of receive and transmit descriptors are configurable on
88     a per-vNIC basis via the UCS Manager and should be greater than or equal to
89     the nb_rx_desc and   nb_tx_desc parameters expected to be used in the calls
90     to rte_eth_rx_queue_setup() and rte_eth_tx_queue_setup() respectively.
91     An application requesting more than the set size will be limited to that
92     size.
93
94     Unless there is a lack of resources due to creating many vNICs, it
95     is recommended that the WQ and RQ sizes be set to the maximum.  This
96     gives the application the greatest amount of flexibility in its
97     queue configuration.
98
99     - *Note*: Since the introduction of Rx scatter, for performance
100       reasons, this PMD uses two RQs on the vNIC per receive queue in
101       DPDK.  One RQ holds descriptors for the start of a packet, and the
102       second RQ holds the descriptors for the rest of the fragments of
103       a packet.  This means that the nb_rx_desc parameter to
104       rte_eth_rx_queue_setup() can be a greater than 4096.  The exact
105       amount will depend on the size of the mbufs being used for
106       receives, and the MTU size.
107
108       For example: If the mbuf size is 2048, and the MTU is 9000, then
109       receiving a full size packet will take 5 descriptors, 1 from the
110       start-of-packet queue, and 4 from the second queue.  Assuming
111       that the RQ size was set to the maximum of 4096, then the
112       application can specify up to 1024 + 4096 as the nb_rx_desc
113       parameter to rte_eth_rx_queue_setup().
114
115   - **Interrupts**
116
117     Only one interrupt per vNIC interface should be configured in the UCS
118     manager regardless of the number receive/transmit queues. The ENIC PMD
119     uses this interrupt to get information about link status and errors
120     in the fast path.
121
122 .. _enic-flow-director:
123
124 Flow director support
125 ---------------------
126
127 Advanced filtering support was added to 1300 series VIC firmware starting
128 with version 2.0.13 for C-series UCS servers and version 3.1.2 for UCSM
129 managed blade servers. In order to enable advanced filtering the 'Advanced
130 filter' radio button should be enabled via CIMC or UCSM followed by a reboot
131 of the server.
132
133 With advanced filters, perfect matching of all fields of IPv4, IPv6 headers
134 as well as TCP, UDP and SCTP L4 headers is available through flow director.
135 Masking of these fields for partial match is also supported.
136
137 Without advanced filter support, the flow director is limited to IPv4
138 perfect filtering of the 5-tuple with no masking of fields supported.
139
140 SR-IOV mode utilization
141 -----------------------
142
143 UCS blade servers configured with dynamic vNIC connection policies in UCS
144 manager are capable of supporting assigned devices on virtual machines (VMs)
145 through a KVM hypervisor. Assigned devices, also known as 'passthrough'
146 devices, are SR-IOV virtual functions (VFs) on the host which are exposed
147 to VM instances.
148
149 The Cisco Virtual Machine Fabric Extender (VM-FEX) gives the VM a dedicated
150 interface on the Fabric Interconnect (FI). Layer 2 switching is done at
151 the FI. This may eliminate the requirement for software switching on the
152 host to route intra-host VM traffic.
153
154 Please refer to `Creating a Dynamic vNIC Connection Policy
155 <http://www.cisco.com/c/en/us/td/docs/unified_computing/ucs/sw/vm_fex/vmware/gui/config_guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide/b_GUI_VMware_VM-FEX_UCSM_Configuration_Guide_chapter_010.html#task_433E01651F69464783A68E66DA8A47A5>`_
156 for information on configuring SR-IOV adapter policies using UCS manager.
157
158 Once the policies are in place and the host OS is rebooted, VFs should be
159 visible on the host, E.g.:
160
161 .. code-block:: console
162
163      # lspci | grep Cisco | grep Ethernet
164      0d:00.0 Ethernet controller: Cisco Systems Inc VIC Ethernet NIC (rev a2)
165      0d:00.1 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
166      0d:00.2 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
167      0d:00.3 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
168      0d:00.4 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
169      0d:00.5 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
170      0d:00.6 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
171      0d:00.7 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
172
173 Enable Intel IOMMU on the host and install KVM and libvirt. A VM instance should
174 be created with an assigned device. When using libvirt, this configuration can
175 be done within the domain (i.e. VM) config file. For example this entry maps
176 host VF 0d:00:01 into the VM.
177
178 .. code-block:: console
179
180     <interface type='hostdev' managed='yes'>
181       <mac address='52:54:00:ac:ff:b6'/>
182       <source>
183         <address type='pci' domain='0x0000' bus='0x0d' slot='0x00' function='0x1'/>
184       </source>
185
186 Alternatively, the configuration can be done in a separate file using the
187 ``network`` keyword. These methods are described in the libvirt documentation for
188 `Network XML format <https://libvirt.org/formatnetwork.html>`_.
189
190 When the VM instance is started, the ENIC KVM driver will bind the host VF to
191 vfio, complete provisioning on the FI and bring up the link.
192
193 .. note::
194
195     It is not possible to use a VF directly from the host because it is not
196     fully provisioned until the hypervisor brings up the VM that it is assigned
197     to.
198
199 In the VM instance, the VF will now be visible. E.g., here the VF 00:04.0 is
200 seen on the VM instance and should be available for binding to a DPDK.
201
202 .. code-block:: console
203
204      # lspci | grep Ether
205      00:04.0 Ethernet controller: Cisco Systems Inc VIC SR-IOV VF (rev a2)
206
207 Follow the normal DPDK install procedure, binding the VF to either ``igb_uio``
208 or ``vfio`` in non-IOMMU mode.
209
210 Please see :ref:`Limitations <enic_limitations>` for limitations in
211 the use of SR-IOV.
212
213 .. _enic-genic-flow-api:
214
215 Generic Flow API support
216 ------------------------
217
218 Generic Flow API is supported. The baseline support is:
219
220 - **1200 series VICs**
221
222   5-tuple exact flow support for 1200 series adapters. This allows:
223
224   - Attributes: ingress
225   - Items: ipv4, ipv6, udp, tcp (must exactly match src/dst IP
226     addresses and ports and all must be specified)
227   - Actions: queue and void
228   - Selectors: 'is'
229
230 - **1300 series VICS with advanced filters disabled**
231
232   With advanced filters disabled, an IPv4 or IPv6 item must be specified
233   in the pattern.
234
235   - Attributes: ingress
236   - Items: eth, ipv4, ipv6, udp, tcp, vxlan, inner eth, ipv4, ipv6, udp, tcp
237   - Actions: queue and void
238   - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
239   - In total, up to 64 bytes of mask is allowed across all headers
240
241 - **1300 series VICS with advanced filters enabled**
242
243   - Attributes: ingress
244   - Items: eth, ipv4, ipv6, udp, tcp, vxlan, inner eth, ipv4, ipv6, udp, tcp
245   - Actions: queue, mark, flag and void
246   - Selectors: 'is', 'spec' and 'mask'. 'last' is not supported
247   - In total, up to 64 bytes of mask is allowed across all headers
248
249 More features may be added in future firmware and new versions of the VIC.
250 Please refer to the release notes.
251
252 .. _enic_limitations:
253
254 Limitations
255 -----------
256
257 - **VLAN 0 Priority Tagging**
258
259   If a vNIC is configured in TRUNK mode by the UCS manager, the adapter will
260   priority tag egress packets according to 802.1Q if they were not already
261   VLAN tagged by software. If the adapter is connected to a properly configured
262   switch, there will be no unexpected behavior.
263
264   In test setups where an Ethernet port of a Cisco adapter in TRUNK mode is
265   connected point-to-point to another adapter port or connected though a router
266   instead of a switch, all ingress packets will be VLAN tagged. Programs such
267   as l3fwd which do not account for VLAN tags in packets will misbehave. The
268   solution is to enable VLAN stripping on ingress. The following code fragment is
269   an example of how to accomplish this:
270
271 .. code-block:: console
272
273      vlan_offload = rte_eth_dev_get_vlan_offload(port);
274      vlan_offload |= ETH_VLAN_STRIP_OFFLOAD;
275      rte_eth_dev_set_vlan_offload(port, vlan_offload);
276
277 - Limited flow director support on 1200 series and 1300 series Cisco VIC
278   adapters with old firmware. Please see :ref:`enic-flow-director`.
279
280 - Flow director features are not supported on generation 1 Cisco VIC adapters
281   (M81KR and P81E)
282
283 - **SR-IOV**
284
285   - KVM hypervisor support only. VMware has not been tested.
286   - Requires VM-FEX, and so is only available on UCS managed servers connected
287     to Fabric Interconnects. It is not on standalone C-Series servers.
288   - VF devices are not usable directly from the host. They can  only be used
289     as assigned devices on VM instances.
290   - Currently, unbind of the ENIC kernel mode driver 'enic.ko' on the VM
291     instance may hang. As a workaround, enic.ko should be blacklisted or removed
292     from the boot process.
293   - pci_generic cannot be used as the uio module in the VM. igb_uio or
294     vfio in non-IOMMU mode can be used.
295   - The number of RQs in UCSM dynamic vNIC configurations must be at least 2.
296   - The number of SR-IOV devices is limited to 256. Components on target system
297     might limit this number to fewer than 256.
298
299 - **Flow API**
300
301   - The number of filters that can be specified with the Generic Flow API is
302     dependent on how many header fields are being masked. Use 'flow create' in
303     a loop to determine how many filters your VIC will support (not more than
304     1000 for 1300 series VICs). Filters are checked for matching in the order they
305     were added. Since there currently is no grouping or priority support,
306     'catch-all' filters should be added last.
307
308 How to build the suite
309 ----------------------
310
311 The build instructions for the DPDK suite should be followed. By default
312 the ENIC PMD library will be built into the DPDK library.
313
314 Refer to the document :ref:`compiling and testing a PMD for a NIC
315 <pmd_build_and_test>` for details.
316
317 For configuring and using UIO and VFIO frameworks, please refer to the
318 documentation that comes with DPDK suite.
319
320 Supported Cisco VIC adapters
321 ----------------------------
322
323 ENIC PMD supports all recent generations of Cisco VIC adapters including:
324
325 - VIC 1280
326 - VIC 1240
327 - VIC 1225
328 - VIC 1285
329 - VIC 1225T
330 - VIC 1227
331 - VIC 1227T
332 - VIC 1380
333 - VIC 1340
334 - VIC 1385
335 - VIC 1387
336
337 Supported Operating Systems
338 ---------------------------
339
340 Any Linux distribution fulfilling the conditions described in Dependencies
341 section of DPDK documentation.
342
343 Supported features
344 ------------------
345
346 - Unicast, multicast and broadcast transmission and reception
347 - Receive queue polling
348 - Port Hardware Statistics
349 - Hardware VLAN acceleration
350 - IP checksum offload
351 - Receive side VLAN stripping
352 - Multiple receive and transmit queues
353 - Flow Director ADD, UPDATE, DELETE, STATS operation support IPv4 and IPv6
354 - Promiscuous mode
355 - Setting RX VLAN (supported via UCSM/CIMC only)
356 - VLAN filtering (supported via UCSM/CIMC only)
357 - Execution of application by unprivileged system users
358 - IPV4, IPV6 and TCP RSS hashing
359 - Scattered Rx
360 - MTU update
361 - SR-IOV on UCS managed servers connected to Fabric Interconnects
362 - Flow API
363
364 Known bugs and unsupported features in this release
365 ---------------------------------------------------
366
367 - Signature or flex byte based flow direction
368 - Drop feature of flow direction
369 - VLAN based flow direction
370 - Non-IPV4 flow direction
371 - Setting of extended VLAN
372 - UDP RSS hashing
373 - MTU update only works if Scattered Rx mode is disabled
374
375 Prerequisites
376 -------------
377
378 - Prepare the system as recommended by DPDK suite.  This includes environment
379   variables, hugepages configuration, tool-chains and configuration.
380 - Insert vfio-pci kernel module using the command 'modprobe vfio-pci' if the
381   user wants to use VFIO framework.
382 - Insert uio kernel module using the command 'modprobe uio' if the user wants
383   to use UIO framework.
384 - DPDK suite should be configured based on the user's decision to use VFIO or
385   UIO framework.
386 - If the vNIC device(s) to be used is bound to the kernel mode Ethernet driver
387   use 'ip' to bring the interface down. The dpdk-devbind.py tool can
388   then be used to unbind the device's bus id from the ENIC kernel mode driver.
389 - Bind the intended vNIC to vfio-pci in case the user wants ENIC PMD to use
390   VFIO framework using dpdk-devbind.py.
391 - Bind the intended vNIC to igb_uio in case the user wants ENIC PMD to use
392   UIO framework using dpdk-devbind.py.
393
394 At this point the system should be ready to run DPDK applications. Once the
395 application runs to completion, the vNIC can be detached from vfio-pci or
396 igb_uio if necessary.
397
398 Root privilege is required to bind and unbind vNICs to/from VFIO/UIO.
399 VFIO framework helps an unprivileged user to run the applications.
400 For an unprivileged user to run the applications on DPDK and ENIC PMD,
401 it may be necessary to increase the maximum locked memory of the user.
402 The following command could be used to do this.
403
404 .. code-block:: console
405
406     sudo sh -c "ulimit -l <value in Kilo Bytes>"
407
408 The value depends on the memory configuration of the application, DPDK and
409 PMD.  Typically, the limit has to be raised to higher than 2GB.
410 e.g., 2621440
411
412 The compilation of any unused drivers can be disabled using the
413 configuration file in config/ directory (e.g., config/common_linuxapp).
414 This would help in bringing down the time taken for building the
415 libraries and the initialization time of the application.
416
417 Additional Reference
418 --------------------
419
420 - https://www.cisco.com/c/en/us/products/servers-unified-computing/index.html
421 - https://www.cisco.com/c/en/us/products/interfaces-modules/unified-computing-system-adapters/index.html
422
423 Contact Information
424 -------------------
425
426 Any questions or bugs should be reported to DPDK community and to the ENIC PMD
427 maintainers:
428
429 - John Daley <johndale@cisco.com>
430 - Nelson Escobar <neescoba@cisco.com>