New upstream version 18.08
[deb_dpdk.git] / doc / guides / nics / i40e.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2016 Intel Corporation.
3
4 I40E Poll Mode Driver
5 ======================
6
7 The i40e PMD (librte_pmd_i40e) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46
47 Prerequisites
48 -------------
49
50 - Identifying your adapter using `Intel Support
51   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
52
53 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
54
55 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
56   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
57
58 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
59   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
60
61 Recommended Matching List
62 -------------------------
63
64 It is highly recommended to upgrade the i40e kernel driver and firmware to
65 avoid the compatibility issues with i40e PMD. Here is the suggested matching
66 list which has been tested and verified. The detailed information can refer
67 to chapter Tested Platforms/Tested NICs in release notes.
68
69    +--------------+-----------------------+------------------+
70    | DPDK version | Kernel driver version | Firmware version |
71    +==============+=======================+==================+
72    |    18.05     |         2.4.6         |       6.01       |
73    +--------------+-----------------------+------------------+
74    |    18.02     |         2.4.3         |       6.01       |
75    +--------------+-----------------------+------------------+
76    |    17.11     |         2.1.26        |       6.01       |
77    +--------------+-----------------------+------------------+
78    |    17.08     |         2.0.19        |       6.01       |
79    +--------------+-----------------------+------------------+
80    |    17.05     |         1.5.23        |       5.05       |
81    +--------------+-----------------------+------------------+
82    |    17.02     |         1.5.23        |       5.05       |
83    +--------------+-----------------------+------------------+
84    |    16.11     |         1.5.23        |       5.05       |
85    +--------------+-----------------------+------------------+
86    |    16.07     |         1.4.25        |       5.04       |
87    +--------------+-----------------------+------------------+
88    |    16.04     |         1.4.25        |       5.02       |
89    +--------------+-----------------------+------------------+
90
91 Pre-Installation Configuration
92 ------------------------------
93
94 Config File Options
95 ~~~~~~~~~~~~~~~~~~~
96
97 The following options can be modified in the ``config`` file.
98 Please note that enabling debugging options may affect system performance.
99
100 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
101
102   Toggle compilation of the ``librte_pmd_i40e`` driver.
103
104 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
105
106   Toggle display of generic debugging messages.
107
108 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
109
110   Toggle bulk allocation for RX.
111
112 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
113
114   Toggle the use of Vector PMD instead of normal RX/TX path.
115   To enable vPMD for RX, bulk allocation for Rx must be allowed.
116
117 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
118
119   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
120
121 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
122
123   Number of queues reserved for PF.
124
125 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
126
127   Number of queues reserved for each VMDQ Pool.
128
129 Runtime Config Options
130 ~~~~~~~~~~~~~~~~~~~~~~
131
132 - ``Number of Queues per VF`` (default ``4``)
133
134   The number of queue per VF is determined by its host PF. If the PCI address
135   of an i40e PF is aaaa:bb.cc, the number of queues per VF can be configured
136   with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n. The value n can be
137   1, 2, 4, 8 or 16. If no such parameter is configured, the number of queues
138   per VF is 4 by default.
139
140 - ``Support multiple driver`` (default ``disable``)
141
142   There was a multiple driver support issue during use of 700 series Ethernet
143   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
144   parameter ``support-multi-driver`` is introduced, for example::
145
146     -w 84:00.0,support-multi-driver=1
147
148   With the above configuration, DPDK PMD will not change global registers, and
149   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
150   DPDK and Linux Kernel.
151
152 - ``Support VF Port Representor`` (default ``not enabled``)
153
154   The i40e PF PMD supports the creation of VF port representors for the control
155   and monitoring of i40e virtual function devices. Each port representor
156   corresponds to a single virtual function of that device. Using the ``devargs``
157   option ``representor`` the user can specify which virtual functions to create
158   port representors for on initialization of the PF PMD by passing the VF IDs of
159   the VFs which are required.::
160
161   -w DBDF,representor=[0,1,4]
162
163   Currently hot-plugging of representor ports is not supported so all required
164   representors must be specified on the creation of the PF.
165
166 Driver compilation and testing
167 ------------------------------
168
169 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
170 for details.
171
172
173 SR-IOV: Prerequisites and sample Application Notes
174 --------------------------------------------------
175
176 #. Load the kernel module:
177
178    .. code-block:: console
179
180       modprobe i40e
181
182    Check the output in dmesg:
183
184    .. code-block:: console
185
186       i40e 0000:83:00.1 ens802f0: renamed from eth0
187
188 #. Bring up the PF ports:
189
190    .. code-block:: console
191
192       ifconfig ens802f0 up
193
194 #. Create VF device(s):
195
196    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
197    of the parent PF.
198
199    Example:
200
201    .. code-block:: console
202
203       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
204
205
206 #. Assign VF MAC address:
207
208    Assign MAC address to the VF using iproute2 utility. The syntax is:
209
210    .. code-block:: console
211
212       ip link set <PF netdev id> vf <VF id> mac <macaddr>
213
214    Example:
215
216    .. code-block:: console
217
218       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
219
220 #. Assign VF to VM, and bring up the VM.
221    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
222
223 #. Running testpmd:
224
225    Follow instructions available in the document
226    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
227    to run testpmd.
228
229    Example output:
230
231    .. code-block:: console
232
233       ...
234       EAL: PCI device 0000:83:00.0 on NUMA socket 1
235       EAL: probe driver: 8086:1572 rte_i40e_pmd
236       EAL: PCI memory mapped at 0x7f7f80000000
237       EAL: PCI memory mapped at 0x7f7f80800000
238       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
239       Interactive-mode selected
240       Configuring Port 0 (socket 0)
241       ...
242
243       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
244       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
245
246       ...
247       Port 0: 68:05:CA:26:85:84
248       Checking link statuses...
249       Port 0 Link Up - speed 10000 Mbps - full-duplex
250       Done
251
252       testpmd>
253
254
255 Sample Application Notes
256 ------------------------
257
258 Vlan filter
259 ~~~~~~~~~~~
260
261 Vlan filter only works when Promiscuous mode is off.
262
263 To start ``testpmd``, and add vlan 10 to port 0:
264
265 .. code-block:: console
266
267     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
268     ...
269
270     testpmd> set promisc 0 off
271     testpmd> rx_vlan add 10 0
272
273
274 Flow Director
275 ~~~~~~~~~~~~~
276
277 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
278 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
279
280 The default input set of each flow type is::
281
282    ipv4-other : src_ip_address, dst_ip_address
283    ipv4-frag  : src_ip_address, dst_ip_address
284    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
285    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
286    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
287                 verification_tag
288    ipv6-other : src_ip_address, dst_ip_address
289    ipv6-frag  : src_ip_address, dst_ip_address
290    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
291    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
292    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
293                 verification_tag
294    l2_payload : ether_type
295
296 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
297
298 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
299
300 .. code-block:: console
301
302    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
303                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
304
305 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
306
307 .. code-block:: console
308
309    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
310             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
311             fwd pf queue 1 fd_id 1
312
313 Check the flow director status:
314
315 .. code-block:: console
316
317    testpmd> show port fdir 0
318
319    ######################## FDIR infos for port 0      ####################
320      MODE:   PERFECT
321      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
322                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
323                            l2_payload
324      FLEX PAYLOAD INFO:
325      max_len:       16          payload_limit: 480
326      payload_unit:  2           payload_seg:   3
327      bitmask_unit:  2           bitmask_num:   2
328      MASK:
329        vlan_tci: 0x0000,
330        src_ipv4: 0x00000000,
331        dst_ipv4: 0x00000000,
332        src_port: 0x0000,
333        dst_port: 0x0000
334        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
335        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
336      FLEX PAYLOAD SRC OFFSET:
337        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
338        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
339        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
340      FLEX MASK CFG:
341        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
342        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
343        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
344        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
345        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
346        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
347        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
348        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
349        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
350        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
351        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
352      guarant_count: 1           best_count:    0
353      guarant_space: 512         best_space:    7168
354      collision:     0           free:          0
355      maxhash:       0           maxlen:        0
356      add:           0           remove:        0
357      f_add:         0           f_remove:      0
358
359
360 Delete all flow director rules on a port:
361
362 .. code-block:: console
363
364    testpmd> flush_flow_director 0
365
366 Floating VEB
367 ~~~~~~~~~~~~~
368
369 The Intel® Ethernet 700 Series support a feature called
370 "Floating VEB".
371
372 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
373 for functionality that allows local switching between virtual endpoints within
374 a physical endpoint and also with an external bridge/network.
375
376 A "Floating" VEB doesn't have an uplink connection to the outside world so all
377 switching is done internally and remains within the host. As such, this
378 feature provides security benefits.
379
380 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
381 cannot forward packets when the physical link is down. Floating VEBs don't need
382 to connect to the NIC port so they can still forward traffic from VF to VF
383 even when the physical link is down.
384
385 Therefore, with this feature enabled VFs can be limited to communicating with
386 each other but not an outside network, and they can do so even when there is
387 no physical uplink on the associated NIC port.
388
389 To enable this feature, the user should pass a ``devargs`` parameter to the
390 EAL, for example::
391
392     -w 84:00.0,enable_floating_veb=1
393
394 In this configuration the PMD will use the floating VEB feature for all the
395 VFs created by this PF device.
396
397 Alternatively, the user can specify which VFs need to connect to this floating
398 VEB using the ``floating_veb_list`` argument::
399
400     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
401
402 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
403 while other VFs connect to the normal VEB.
404
405 The current implementation only supports one floating VEB and one regular
406 VEB. VFs can connect to a floating VEB or a regular VEB according to the
407 configuration passed on the EAL command line.
408
409 The floating VEB functionality requires a NIC firmware version of 5.0
410 or greater.
411
412 Dynamic Device Personalization (DDP)
413 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
414
415 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
416 X722 support a feature called "Dynamic Device Personalization (DDP)",
417 which is used to configure hardware by downloading a profile to support
418 protocols/filters which are not supported by default. The DDP
419 functionality requires a NIC firmware version of 6.0 or greater.
420
421 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP,
422 steering can be used with rte_flow API.
423
424 Load a profile which supports GTP and store backup profile:
425
426 .. code-block:: console
427
428    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
429
430 Delete a GTP profile and restore backup profile:
431
432 .. code-block:: console
433
434    testpmd> ddp del 0 ./backup.pkgo
435
436 Get loaded DDP package info list:
437
438 .. code-block:: console
439
440    testpmd> ddp get list 0
441
442 Display information about a GTP profile:
443
444 .. code-block:: console
445
446    testpmd> ddp get info ./gtp.pkgo
447
448 Input set configuration
449 ~~~~~~~~~~~~~~~~~~~~~~~
450 Input set for any PCTYPE can be configured with user defined configuration,
451 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
452
453 .. code-block:: console
454
455    testpmd> port config 0 pctype 43 hash_inset clear all
456    testpmd> port config 0 pctype 43 hash_inset set field 13
457    testpmd> port config 0 pctype 43 hash_inset set field 14
458    testpmd> port config 0 pctype 43 hash_inset set field 15
459
460 Queue region configuration
461 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
462 The Intel® Ethernet 700 Series supports a feature of queue regions
463 configuration for RSS in the PF, so that different traffic classes or
464 different packet classification types can be separated to different
465 queues in different queue regions. There is an API for configuration
466 of queue regions in RSS with a command line. It can parse the parameters
467 of the region index, queue number, queue start index, user priority, traffic
468 classes and so on. Depending on commands from the command line, it will call
469 i40e private APIs and start the process of setting or flushing the queue
470 region configuration. As this feature is specific for i40e only private
471 APIs are used. These new ``test_pmd`` commands are as shown below. For
472 details please refer to :doc:`../testpmd_app_ug/index`.
473
474 .. code-block:: console
475
476    testpmd> set port (port_id) queue-region region_id (value) \
477                 queue_start_index (value) queue_num (value)
478    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
479    testpmd> set port (port_id) queue-region UP (value) region_id (value)
480    testpmd> set port (port_id) queue-region flush (on|off)
481    testpmd> show port (port_id) queue-region
482
483 Limitations or Known issues
484 ---------------------------
485
486 MPLS packet classification
487 ~~~~~~~~~~~~~~~~~~~~~~~~~~
488
489 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
490 The L2 Payload flow type in flow director can be used to classify MPLS packet
491 by using a command in testpmd like:
492
493    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
494             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
495
496 With the NIC firmware version 5.0 or greater, some limited MPLS support
497 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
498 new packet type, no classification or offload are possible. With this change,
499 L2 Payload flow type in flow director cannot be used to classify MPLS packet
500 as with previous firmware versions. Meanwhile, the Ethertype filter can be
501 used to classify MPLS packet by using a command in testpmd like:
502
503    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
504             0x8847 fwd queue <M>
505
506 16 Byte RX Descriptor setting on DPDK VF
507 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
508
509 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
510 interface for VF to request the RX descriptor mode, also no interface to notify
511 VF its own RX descriptor mode.
512 For all available versions of the i40e driver, these drivers don't support 16
513 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
514 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
515 descriptor. The reason is that the RX descriptor is already set to 32 byte by
516 the i40e kernel driver. That is to say, user should keep
517 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
518 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
519 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
520 byte, as the PF driver.
521
522 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
523 descriptor mode. Or the VF RX will not work.
524
525 Receive packets with Ethertype 0x88A8
526 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
527
528 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
529 only when floating VEB is disabled.
530
531 Incorrect Rx statistics when packet is oversize
532 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
533
534 When a packet is over maximum frame size, the packet is dropped.
535 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
536 shows it as received.
537
538 VF & TC max bandwidth setting
539 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
540
541 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
542 The behavior is different when handling per VF and per TC max bandwidth setting.
543 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
544 enabled. If so, return failure.
545 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
546 is enabled. If so, disable per VF max bandwidth and continue with per TC max
547 bandwidth setting.
548
549 TC TX scheduling mode setting
550 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
551
552 There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
553 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
554 It means if APP has set the max bandwidth for that TC, it comes to no
555 effect.
556 It's suggested to set the strict priority mode for a TC that is latency
557 sensitive but no consuming much bandwidth.
558
559 VF performance is impacted by PCI extended tag setting
560 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
561
562 To reach maximum NIC performance in the VF the PCI extended tag must be
563 enabled. The DPDK i40e PF driver will set this feature during initialization,
564 but the kernel PF driver does not. So when running traffic on a VF which is
565 managed by the kernel PF driver, a significant NIC performance downgrade has
566 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
567 a 25GbE device and about 35% for a 40GbE device).
568
569 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
570 tag if it detects that the device supports it. So by default, this is not an
571 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
572 enabled using the steps below.
573
574 #. Get the current value of the PCI configure register::
575
576       setpci -s <XX:XX.X> a8.w
577
578 #. Set bit 8::
579
580       value = value | 0x100
581
582 #. Set the PCI configure register with new value::
583
584       setpci -s <XX:XX.X> a8.w=<value>
585
586 Vlan strip of VF
587 ~~~~~~~~~~~~~~~~
588
589 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
590
591 DCB function
592 ~~~~~~~~~~~~
593
594 DCB works only when RSS is enabled.
595
596 Global configuration warning
597 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
598
599 I40E PMD will set some global registers to enable some function or set some
600 configure. Then when using different ports of the same NIC with Linux kernel
601 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
602 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
603 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
604 with DPDK, then the configuration will also impact port B in the NIC with
605 kernel driver, which don't want to use the TPID.
606 So PMD reports warning to clarify what is changed by writing global register.
607
608 High Performance of Small Packets on 40GbE NIC
609 ----------------------------------------------
610
611 As there might be firmware fixes for performance enhancement in latest version
612 of firmware image, the firmware update might be needed for getting high performance.
613 Check the Intel support website for the latest firmware updates.
614 Users should consult the release notes specific to a DPDK release to identify
615 the validated firmware version for a NIC using the i40e driver.
616
617 Use 16 Bytes RX Descriptor Size
618 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
619
620 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
621 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
622
623 Example of getting best performance with l3fwd example
624 ------------------------------------------------------
625
626 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
627 server with Intel Xeon processors and Intel Ethernet CNA XL710.
628
629 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
630 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
631
632 .. _figure_intel_perf_test_setup:
633
634 .. figure:: img/intel_perf_test_setup.*
635
636    Performance Test Setup
637
638
639 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
640    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
641    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
642    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
643
644       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
645       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
646
647 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
648
649 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
650    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
651    are 18-35 and 54-71.
652    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
653    cores from different cores (e.g core18 and core19).
654
655 4. Bind these two ports to igb_uio.
656
657 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
658    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
659
660 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
661    Compile the ``l3fwd sample`` with the default lpm mode.
662
663 7. The command line of running l3fwd would be something like the following::
664
665       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
666               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
667
668    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
669    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
670
671 8. Configure the traffic at a traffic generator.
672
673    * Start creating a stream on packet generator.
674
675    * Set the Ethernet II type to 0x0800.