New upstream version 18.11-rc1
[deb_dpdk.git] / doc / guides / nics / i40e.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2016 Intel Corporation.
3
4 I40E Poll Mode Driver
5 ======================
6
7 The i40e PMD (librte_pmd_i40e) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46
47 Prerequisites
48 -------------
49
50 - Identifying your adapter using `Intel Support
51   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
52
53 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
54
55 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
56   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
57
58 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
59   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
60
61 Recommended Matching List
62 -------------------------
63
64 It is highly recommended to upgrade the i40e kernel driver and firmware to
65 avoid the compatibility issues with i40e PMD. Here is the suggested matching
66 list which has been tested and verified. The detailed information can refer
67 to chapter Tested Platforms/Tested NICs in release notes.
68
69    +--------------+-----------------------+------------------+
70    | DPDK version | Kernel driver version | Firmware version |
71    +==============+=======================+==================+
72    |    18.05     |         2.4.6         |       6.01       |
73    +--------------+-----------------------+------------------+
74    |    18.02     |         2.4.3         |       6.01       |
75    +--------------+-----------------------+------------------+
76    |    17.11     |         2.1.26        |       6.01       |
77    +--------------+-----------------------+------------------+
78    |    17.08     |         2.0.19        |       6.01       |
79    +--------------+-----------------------+------------------+
80    |    17.05     |         1.5.23        |       5.05       |
81    +--------------+-----------------------+------------------+
82    |    17.02     |         1.5.23        |       5.05       |
83    +--------------+-----------------------+------------------+
84    |    16.11     |         1.5.23        |       5.05       |
85    +--------------+-----------------------+------------------+
86    |    16.07     |         1.4.25        |       5.04       |
87    +--------------+-----------------------+------------------+
88    |    16.04     |         1.4.25        |       5.02       |
89    +--------------+-----------------------+------------------+
90
91 Pre-Installation Configuration
92 ------------------------------
93
94 Config File Options
95 ~~~~~~~~~~~~~~~~~~~
96
97 The following options can be modified in the ``config`` file.
98 Please note that enabling debugging options may affect system performance.
99
100 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
101
102   Toggle compilation of the ``librte_pmd_i40e`` driver.
103
104 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
105
106   Toggle display of generic debugging messages.
107
108 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
109
110   Toggle bulk allocation for RX.
111
112 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
113
114   Toggle the use of Vector PMD instead of normal RX/TX path.
115   To enable vPMD for RX, bulk allocation for Rx must be allowed.
116
117 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
118
119   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
120
121 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
122
123   Number of queues reserved for PF.
124
125 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
126
127   Number of queues reserved for each VMDQ Pool.
128
129 Runtime Config Options
130 ~~~~~~~~~~~~~~~~~~~~~~
131
132 - ``Number of Queues per VF`` (default ``4``)
133
134   The number of queue per VF is determined by its host PF. If the PCI address
135   of an i40e PF is aaaa:bb.cc, the number of queues per VF can be configured
136   with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n. The value n can be
137   1, 2, 4, 8 or 16. If no such parameter is configured, the number of queues
138   per VF is 4 by default.
139
140 - ``Support multiple driver`` (default ``disable``)
141
142   There was a multiple driver support issue during use of 700 series Ethernet
143   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
144   parameter ``support-multi-driver`` is introduced, for example::
145
146     -w 84:00.0,support-multi-driver=1
147
148   With the above configuration, DPDK PMD will not change global registers, and
149   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
150   DPDK and Linux Kernel.
151
152 - ``Support VF Port Representor`` (default ``not enabled``)
153
154   The i40e PF PMD supports the creation of VF port representors for the control
155   and monitoring of i40e virtual function devices. Each port representor
156   corresponds to a single virtual function of that device. Using the ``devargs``
157   option ``representor`` the user can specify which virtual functions to create
158   port representors for on initialization of the PF PMD by passing the VF IDs of
159   the VFs which are required.::
160
161   -w DBDF,representor=[0,1,4]
162
163   Currently hot-plugging of representor ports is not supported so all required
164   representors must be specified on the creation of the PF.
165
166 - ``Use latest supported vector`` (default ``disable``)
167
168   Latest supported vector path may not always get the best perf so vector path was
169   recommended to use only on later platform. But users may want the latest vector path
170   since it can get better perf in some real work loading cases. So ``devargs`` param
171   ``use-latest-supported-vec`` is introduced, for example::
172
173   -w 84:00.0,use-latest-supported-vec=1
174
175 Driver compilation and testing
176 ------------------------------
177
178 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
179 for details.
180
181
182 SR-IOV: Prerequisites and sample Application Notes
183 --------------------------------------------------
184
185 #. Load the kernel module:
186
187    .. code-block:: console
188
189       modprobe i40e
190
191    Check the output in dmesg:
192
193    .. code-block:: console
194
195       i40e 0000:83:00.1 ens802f0: renamed from eth0
196
197 #. Bring up the PF ports:
198
199    .. code-block:: console
200
201       ifconfig ens802f0 up
202
203 #. Create VF device(s):
204
205    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
206    of the parent PF.
207
208    Example:
209
210    .. code-block:: console
211
212       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
213
214
215 #. Assign VF MAC address:
216
217    Assign MAC address to the VF using iproute2 utility. The syntax is:
218
219    .. code-block:: console
220
221       ip link set <PF netdev id> vf <VF id> mac <macaddr>
222
223    Example:
224
225    .. code-block:: console
226
227       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
228
229 #. Assign VF to VM, and bring up the VM.
230    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
231
232 #. Running testpmd:
233
234    Follow instructions available in the document
235    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
236    to run testpmd.
237
238    Example output:
239
240    .. code-block:: console
241
242       ...
243       EAL: PCI device 0000:83:00.0 on NUMA socket 1
244       EAL: probe driver: 8086:1572 rte_i40e_pmd
245       EAL: PCI memory mapped at 0x7f7f80000000
246       EAL: PCI memory mapped at 0x7f7f80800000
247       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
248       Interactive-mode selected
249       Configuring Port 0 (socket 0)
250       ...
251
252       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
253       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
254
255       ...
256       Port 0: 68:05:CA:26:85:84
257       Checking link statuses...
258       Port 0 Link Up - speed 10000 Mbps - full-duplex
259       Done
260
261       testpmd>
262
263
264 Sample Application Notes
265 ------------------------
266
267 Vlan filter
268 ~~~~~~~~~~~
269
270 Vlan filter only works when Promiscuous mode is off.
271
272 To start ``testpmd``, and add vlan 10 to port 0:
273
274 .. code-block:: console
275
276     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
277     ...
278
279     testpmd> set promisc 0 off
280     testpmd> rx_vlan add 10 0
281
282
283 Flow Director
284 ~~~~~~~~~~~~~
285
286 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
287 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
288
289 The default input set of each flow type is::
290
291    ipv4-other : src_ip_address, dst_ip_address
292    ipv4-frag  : src_ip_address, dst_ip_address
293    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
294    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
295    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
296                 verification_tag
297    ipv6-other : src_ip_address, dst_ip_address
298    ipv6-frag  : src_ip_address, dst_ip_address
299    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
300    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
301    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
302                 verification_tag
303    l2_payload : ether_type
304
305 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
306
307 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
308
309 .. code-block:: console
310
311    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
312                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
313
314 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
315
316 .. code-block:: console
317
318    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
319             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
320             fwd pf queue 1 fd_id 1
321
322 Check the flow director status:
323
324 .. code-block:: console
325
326    testpmd> show port fdir 0
327
328    ######################## FDIR infos for port 0      ####################
329      MODE:   PERFECT
330      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
331                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
332                            l2_payload
333      FLEX PAYLOAD INFO:
334      max_len:       16          payload_limit: 480
335      payload_unit:  2           payload_seg:   3
336      bitmask_unit:  2           bitmask_num:   2
337      MASK:
338        vlan_tci: 0x0000,
339        src_ipv4: 0x00000000,
340        dst_ipv4: 0x00000000,
341        src_port: 0x0000,
342        dst_port: 0x0000
343        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
344        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
345      FLEX PAYLOAD SRC OFFSET:
346        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
347        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
348        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
349      FLEX MASK CFG:
350        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
351        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
352        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
353        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
354        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
355        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
356        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
357        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
358        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
359        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
360        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
361      guarant_count: 1           best_count:    0
362      guarant_space: 512         best_space:    7168
363      collision:     0           free:          0
364      maxhash:       0           maxlen:        0
365      add:           0           remove:        0
366      f_add:         0           f_remove:      0
367
368
369 Delete all flow director rules on a port:
370
371 .. code-block:: console
372
373    testpmd> flush_flow_director 0
374
375 Floating VEB
376 ~~~~~~~~~~~~~
377
378 The Intel® Ethernet 700 Series support a feature called
379 "Floating VEB".
380
381 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
382 for functionality that allows local switching between virtual endpoints within
383 a physical endpoint and also with an external bridge/network.
384
385 A "Floating" VEB doesn't have an uplink connection to the outside world so all
386 switching is done internally and remains within the host. As such, this
387 feature provides security benefits.
388
389 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
390 cannot forward packets when the physical link is down. Floating VEBs don't need
391 to connect to the NIC port so they can still forward traffic from VF to VF
392 even when the physical link is down.
393
394 Therefore, with this feature enabled VFs can be limited to communicating with
395 each other but not an outside network, and they can do so even when there is
396 no physical uplink on the associated NIC port.
397
398 To enable this feature, the user should pass a ``devargs`` parameter to the
399 EAL, for example::
400
401     -w 84:00.0,enable_floating_veb=1
402
403 In this configuration the PMD will use the floating VEB feature for all the
404 VFs created by this PF device.
405
406 Alternatively, the user can specify which VFs need to connect to this floating
407 VEB using the ``floating_veb_list`` argument::
408
409     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
410
411 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
412 while other VFs connect to the normal VEB.
413
414 The current implementation only supports one floating VEB and one regular
415 VEB. VFs can connect to a floating VEB or a regular VEB according to the
416 configuration passed on the EAL command line.
417
418 The floating VEB functionality requires a NIC firmware version of 5.0
419 or greater.
420
421 Dynamic Device Personalization (DDP)
422 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
423
424 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
425 X722 support a feature called "Dynamic Device Personalization (DDP)",
426 which is used to configure hardware by downloading a profile to support
427 protocols/filters which are not supported by default. The DDP
428 functionality requires a NIC firmware version of 6.0 or greater.
429
430 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP,
431 steering can be used with rte_flow API.
432
433 GTPv1 package is released, and it can be downloaded from
434 https://downloadcenter.intel.com/download/27587.
435
436 PPPoE package is released, and it can be downloaded from
437 https://downloadcenter.intel.com/download/28040.
438
439 Load a profile which supports GTP and store backup profile:
440
441 .. code-block:: console
442
443    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
444
445 Delete a GTP profile and restore backup profile:
446
447 .. code-block:: console
448
449    testpmd> ddp del 0 ./backup.pkgo
450
451 Get loaded DDP package info list:
452
453 .. code-block:: console
454
455    testpmd> ddp get list 0
456
457 Display information about a GTP profile:
458
459 .. code-block:: console
460
461    testpmd> ddp get info ./gtp.pkgo
462
463 Input set configuration
464 ~~~~~~~~~~~~~~~~~~~~~~~
465 Input set for any PCTYPE can be configured with user defined configuration,
466 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
467
468 .. code-block:: console
469
470    testpmd> port config 0 pctype 43 hash_inset clear all
471    testpmd> port config 0 pctype 43 hash_inset set field 13
472    testpmd> port config 0 pctype 43 hash_inset set field 14
473    testpmd> port config 0 pctype 43 hash_inset set field 15
474
475 Queue region configuration
476 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
477 The Intel® Ethernet 700 Series supports a feature of queue regions
478 configuration for RSS in the PF, so that different traffic classes or
479 different packet classification types can be separated to different
480 queues in different queue regions. There is an API for configuration
481 of queue regions in RSS with a command line. It can parse the parameters
482 of the region index, queue number, queue start index, user priority, traffic
483 classes and so on. Depending on commands from the command line, it will call
484 i40e private APIs and start the process of setting or flushing the queue
485 region configuration. As this feature is specific for i40e only private
486 APIs are used. These new ``test_pmd`` commands are as shown below. For
487 details please refer to :doc:`../testpmd_app_ug/index`.
488
489 .. code-block:: console
490
491    testpmd> set port (port_id) queue-region region_id (value) \
492                 queue_start_index (value) queue_num (value)
493    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
494    testpmd> set port (port_id) queue-region UP (value) region_id (value)
495    testpmd> set port (port_id) queue-region flush (on|off)
496    testpmd> show port (port_id) queue-region
497
498 Limitations or Known issues
499 ---------------------------
500
501 MPLS packet classification
502 ~~~~~~~~~~~~~~~~~~~~~~~~~~
503
504 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
505 The L2 Payload flow type in flow director can be used to classify MPLS packet
506 by using a command in testpmd like:
507
508    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
509             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
510
511 With the NIC firmware version 5.0 or greater, some limited MPLS support
512 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
513 new packet type, no classification or offload are possible. With this change,
514 L2 Payload flow type in flow director cannot be used to classify MPLS packet
515 as with previous firmware versions. Meanwhile, the Ethertype filter can be
516 used to classify MPLS packet by using a command in testpmd like:
517
518    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
519             0x8847 fwd queue <M>
520
521 16 Byte RX Descriptor setting on DPDK VF
522 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
523
524 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
525 interface for VF to request the RX descriptor mode, also no interface to notify
526 VF its own RX descriptor mode.
527 For all available versions of the i40e driver, these drivers don't support 16
528 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
529 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
530 descriptor. The reason is that the RX descriptor is already set to 32 byte by
531 the i40e kernel driver. That is to say, user should keep
532 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
533 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
534 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
535 byte, as the PF driver.
536
537 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
538 descriptor mode. Or the VF RX will not work.
539
540 Receive packets with Ethertype 0x88A8
541 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
542
543 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
544 only when floating VEB is disabled.
545
546 Incorrect Rx statistics when packet is oversize
547 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
548
549 When a packet is over maximum frame size, the packet is dropped.
550 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
551 shows it as received.
552
553 VF & TC max bandwidth setting
554 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
555
556 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
557 The behavior is different when handling per VF and per TC max bandwidth setting.
558 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
559 enabled. If so, return failure.
560 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
561 is enabled. If so, disable per VF max bandwidth and continue with per TC max
562 bandwidth setting.
563
564 TC TX scheduling mode setting
565 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
566
567 There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
568 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
569 It means if APP has set the max bandwidth for that TC, it comes to no
570 effect.
571 It's suggested to set the strict priority mode for a TC that is latency
572 sensitive but no consuming much bandwidth.
573
574 VF performance is impacted by PCI extended tag setting
575 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
576
577 To reach maximum NIC performance in the VF the PCI extended tag must be
578 enabled. The DPDK i40e PF driver will set this feature during initialization,
579 but the kernel PF driver does not. So when running traffic on a VF which is
580 managed by the kernel PF driver, a significant NIC performance downgrade has
581 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
582 a 25GbE device and about 35% for a 40GbE device).
583
584 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
585 tag if it detects that the device supports it. So by default, this is not an
586 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
587 enabled using the steps below.
588
589 #. Get the current value of the PCI configure register::
590
591       setpci -s <XX:XX.X> a8.w
592
593 #. Set bit 8::
594
595       value = value | 0x100
596
597 #. Set the PCI configure register with new value::
598
599       setpci -s <XX:XX.X> a8.w=<value>
600
601 Vlan strip of VF
602 ~~~~~~~~~~~~~~~~
603
604 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
605
606 DCB function
607 ~~~~~~~~~~~~
608
609 DCB works only when RSS is enabled.
610
611 Global configuration warning
612 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
613
614 I40E PMD will set some global registers to enable some function or set some
615 configure. Then when using different ports of the same NIC with Linux kernel
616 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
617 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
618 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
619 with DPDK, then the configuration will also impact port B in the NIC with
620 kernel driver, which don't want to use the TPID.
621 So PMD reports warning to clarify what is changed by writing global register.
622
623 High Performance of Small Packets on 40GbE NIC
624 ----------------------------------------------
625
626 As there might be firmware fixes for performance enhancement in latest version
627 of firmware image, the firmware update might be needed for getting high performance.
628 Check the Intel support website for the latest firmware updates.
629 Users should consult the release notes specific to a DPDK release to identify
630 the validated firmware version for a NIC using the i40e driver.
631
632 Use 16 Bytes RX Descriptor Size
633 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
634
635 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
636 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
637
638 Example of getting best performance with l3fwd example
639 ------------------------------------------------------
640
641 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
642 server with Intel Xeon processors and Intel Ethernet CNA XL710.
643
644 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
645 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
646
647 .. _figure_intel_perf_test_setup:
648
649 .. figure:: img/intel_perf_test_setup.*
650
651    Performance Test Setup
652
653
654 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
655    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
656    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
657    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
658
659       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
660       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
661
662 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
663
664 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
665    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
666    are 18-35 and 54-71.
667    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
668    cores from different cores (e.g core18 and core19).
669
670 4. Bind these two ports to igb_uio.
671
672 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
673    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
674
675 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
676    Compile the ``l3fwd sample`` with the default lpm mode.
677
678 7. The command line of running l3fwd would be something like the following::
679
680       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
681               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
682
683    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
684    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
685
686 8. Configure the traffic at a traffic generator.
687
688    * Start creating a stream on packet generator.