[deb_dpdk.git] / doc / guides / nics / i40e.rst
1 ..  BSD LICENSE
2     Copyright(c) 2016 Intel Corporation. All rights reserved.
3     All rights reserved.
4
5     Redistribution and use in source and binary forms, with or without
6     modification, are permitted provided that the following conditions
7     are met:
8
9     * Redistributions of source code must retain the above copyright
10     notice, this list of conditions and the following disclaimer.
11     * Redistributions in binary form must reproduce the above copyright
12     notice, this list of conditions and the following disclaimer in
13     the documentation and/or other materials provided with the
14     distribution.
15     * Neither the name of Intel Corporation nor the names of its
16     contributors may be used to endorse or promote products derived
17     from this software without specific prior written permission.
18
19     THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
20     "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
21     LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
22     A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
23     OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
24     SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
25     LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
26     DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
27     THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
28     (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
29     OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
30
31 I40E Poll Mode Driver
32 ======================
33
34 The I40E PMD (librte_pmd_i40e) provides poll mode driver support
35 for the Intel X710/XL710/X722 10/40 Gbps family of adapters.
36
37
38 Features
39 --------
40
41 Features of the I40E PMD are:
42
43 - Multiple queues for TX and RX
44 - Receiver Side Scaling (RSS)
45 - MAC/VLAN filtering
46 - Packet type information
47 - Flow director
48 - Cloud filter
49 - Checksum offload
50 - VLAN/QinQ stripping and inserting
51 - TSO offload
52 - Promiscuous mode
53 - Multicast mode
54 - Port hardware statistics
55 - Jumbo frames
56 - Link state information
57 - Link flow control
58 - Mirror on port, VLAN and VSI
59 - Interrupt mode for RX
60 - Scattered and gather for TX and RX
61 - Vector Poll mode driver
62 - DCB
63 - VMDQ
64 - SR-IOV VF
65 - Hot plug
66 - IEEE1588/802.1AS timestamping
67 - VF Daemon (VFD) - EXPERIMENTAL
68
69
70 Prerequisites
71 -------------
72
73 - Identifying your adapter using `Intel Support
74   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
75
76 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
77
78 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
79   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
80
81
82 Pre-Installation Configuration
83 ------------------------------
84
85 Config File Options
86 ~~~~~~~~~~~~~~~~~~~
87
88 The following options can be modified in the ``config`` file.
89 Please note that enabling debugging options may affect system performance.
90
91 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
92
93   Toggle compilation of the ``librte_pmd_i40e`` driver.
94
95 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
96
97   Toggle display of generic debugging messages.
98
99 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
100
101   Toggle bulk allocation for RX.
102
103 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
104
105   Toggle the use of Vector PMD instead of normal RX/TX path.
106   To enable vPMD for RX, bulk allocation for Rx must be allowed.
107
108 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
109
110   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
111
112 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
113
114   Number of queues reserved for PF.
115
116 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VF`` (default ``4``)
117
118   Number of queues reserved for each SR-IOV VF.
119
120 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
121
122   Number of queues reserved for each VMDQ Pool.
123
124 - ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` (default ``-1``)
125
126   Interrupt Throttling interval.
127
128
129 Driver compilation and testing
130 ------------------------------
131
132 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
133 for details.
134
135
136 SR-IOV: Prerequisites and sample Application Notes
137 --------------------------------------------------
138
139 #. Load the kernel module:
140
141    .. code-block:: console
142
143       modprobe i40e
144
145    Check the output in dmesg:
146
147    .. code-block:: console
148
149       i40e 0000:83:00.1 ens802f0: renamed from eth0
150
151 #. Bring up the PF ports:
152
153    .. code-block:: console
154
155       ifconfig ens802f0 up
156
157 #. Create VF device(s):
158
159    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
160    of the parent PF.
161
162    Example:
163
164    .. code-block:: console
165
166       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
167
168
169 #. Assign VF MAC address:
170
171    Assign MAC address to the VF using iproute2 utility. The syntax is:
172
173    .. code-block:: console
174
175       ip link set <PF netdev id> vf <VF id> mac <macaddr>
176
177    Example:
178
179    .. code-block:: console
180
181       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
182
183 #. Assign VF to VM, and bring up the VM.
184    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
185
186 #. Running testpmd:
187
188    Follow instructions available in the document
189    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
190    to run testpmd.
191
192    Example output:
193
194    .. code-block:: console
195
196       ...
197       EAL: PCI device 0000:83:00.0 on NUMA socket 1
198       EAL: probe driver: 8086:1572 rte_i40e_pmd
199       EAL: PCI memory mapped at 0x7f7f80000000
200       EAL: PCI memory mapped at 0x7f7f80800000
201       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
202       Interactive-mode selected
203       Configuring Port 0 (socket 0)
204       ...
205
206       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
207       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
208
209       ...
210       Port 0: 68:05:CA:26:85:84
211       Checking link statuses...
212       Port 0 Link Up - speed 10000 Mbps - full-duplex
213       Done
214
215       testpmd>
216
217
218 Sample Application Notes
219 ------------------------
220
221 Vlan filter
222 ~~~~~~~~~~~
223
224 Vlan filter only works when Promiscuous mode is off.
225
226 To start ``testpmd``, and add vlan 10 to port 0:
227
228 .. code-block:: console
229
230     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
231     ...
232
233     testpmd> set promisc 0 off
234     testpmd> rx_vlan add 10 0
235
236
237 Flow Director
238 ~~~~~~~~~~~~~
239
240 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
241 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
242
243 The default input set of each flow type is::
244
245    ipv4-other : src_ip_address, dst_ip_address
246    ipv4-frag  : src_ip_address, dst_ip_address
247    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
248    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
249    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
250                 verification_tag
251    ipv6-other : src_ip_address, dst_ip_address
252    ipv6-frag  : src_ip_address, dst_ip_address
253    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
254    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
255    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
256                 verification_tag
257    l2_payload : ether_type
258
259 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
260
261 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
262
263 .. code-block:: console
264
265    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
266                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
267
268 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
269
270 .. code-block:: console
271
272    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
273             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
274             fwd pf queue 1 fd_id 1
275
276 Check the flow director status:
277
278 .. code-block:: console
279
280    testpmd> show port fdir 0
281
282    ######################## FDIR infos for port 0      ####################
283      MODE:   PERFECT
284      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
285                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
286                            l2_payload
287      FLEX PAYLOAD INFO:
288      max_len:       16          payload_limit: 480
289      payload_unit:  2           payload_seg:   3
290      bitmask_unit:  2           bitmask_num:   2
291      MASK:
292        vlan_tci: 0x0000,
293        src_ipv4: 0x00000000,
294        dst_ipv4: 0x00000000,
295        src_port: 0x0000,
296        dst_port: 0x0000
297        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
298        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
299      FLEX PAYLOAD SRC OFFSET:
300        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
301        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
302        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
303      FLEX MASK CFG:
304        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
305        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
306        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
307        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
308        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
309        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
310        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
311        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
312        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
313        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
314        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
315      guarant_count: 1           best_count:    0
316      guarant_space: 512         best_space:    7168
317      collision:     0           free:          0
318      maxhash:       0           maxlen:        0
319      add:           0           remove:        0
320      f_add:         0           f_remove:      0
321
322
323 Delete all flow director rules on a port:
324
325 .. code-block:: console
326
327    testpmd> flush_flow_director 0
328
329 Floating VEB
330 ~~~~~~~~~~~~~
331
332 The IntelĀ® Ethernet Controller X710 and XL710 Family support a feature called
333 "Floating VEB".
334
335 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
336 for functionality that allows local switching between virtual endpoints within
337 a physical endpoint and also with an external bridge/network.
338
339 A "Floating" VEB doesn't have an uplink connection to the outside world so all
340 switching is done internally and remains within the host. As such, this
341 feature provides security benefits.
342
343 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
344 cannot forward packets when the physical link is down. Floating VEBs don't need
345 to connect to the NIC port so they can still forward traffic from VF to VF
346 even when the physical link is down.
347
348 Therefore, with this feature enabled VFs can be limited to communicating with
349 each other but not an outside network, and they can do so even when there is
350 no physical uplink on the associated NIC port.
351
352 To enable this feature, the user should pass a ``devargs`` parameter to the
353 EAL, for example::
354
355     -w 84:00.0,enable_floating_veb=1
356
357 In this configuration the PMD will use the floating VEB feature for all the
358 VFs created by this PF device.
359
360 Alternatively, the user can specify which VFs need to connect to this floating
361 VEB using the ``floating_veb_list`` argument::
362
363     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
364
365 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
366 while other VFs connect to the normal VEB.
367
368 The current implementation only supports one floating VEB and one regular
369 VEB. VFs can connect to a floating VEB or a regular VEB according to the
370 configuration passed on the EAL command line.
371
372 The floating VEB functionality requires a NIC firmware version of 5.0
373 or greater.
374
375
376 Limitations or Known issues
377 ---------------------------
378
379 MPLS packet classification on X710/XL710
380 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
381
382 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
383 The L2 Payload flow type in flow director can be used to classify MPLS packet
384 by using a command in testpmd like:
385
386    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
387             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
388
389 With the NIC firmware version 5.0 or greater, some limited MPLS support
390 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
391 new packet type, no classification or offload are possible. With this change,
392 L2 Payload flow type in flow director cannot be used to classify MPLS packet
393 as with previous firmware versions. Meanwhile, the Ethertype filter can be
394 used to classify MPLS packet by using a command in testpmd like:
395
396    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
397             0x8847 fwd queue <M>
398
399 16 Byte Descriptor cannot be used on DPDK VF
400 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
401
402 If the Linux i40e kernel driver is used as host driver, while DPDK i40e PMD
403 is used as the VF driver, DPDK cannot choose 16 byte receive descriptor. That
404 is to say, user should keep ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in
405 config file.
406
407 Receive packets with Ethertype 0x88A8
408 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
409
410 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
411 only when floating VEB is disabled.
412
413 Incorrect Rx statistics when packet is oversize
414 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
415
416 When a packet is over maximum frame size, the packet is dropped.
417 However the Rx statistics, when calling `rte_eth_stats_get` incorrectly
418 shows it as received.
419
420 VF & TC max bandwidth setting
421 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
422
423 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
424 The dehavior is different when handling per VF and per TC max bandwidth setting.
425 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
426 enabled. If so, return failure.
427 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
428 is enabled. If so, disable per VF max bandwidth and continue with per TC max
429 bandwidth setting.
430
431 TC TX scheduling mode setting
432 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
433
434 There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
435 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
436 It means if APP has set the max bandwidth for that TC, it comes to no
437 effect.
438 It's suggested to set the strict priority mode for a TC that is latency
439 sensitive but no consuming much bandwidth.
440
441 VF performance is impacted by PCI extended tag setting
442 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
443
444 To reach maximum NIC performance in the VF the PCI extended tag must be
445 enabled. The DPDK I40E PF driver will set this feature during initialization,
446 but the kernel PF driver does not. So when running traffic on a VF which is
447 managed by the kernel PF driver, a significant NIC performance downgrade has
448 been observed (for 64 byte packets, there is about 25% linerate downgrade for
449 a 25G device and about 35% for a 40G device).
450
451 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
452 tag if it detects that the device supports it. So by default, this is not an
453 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
454 enabled using the steps below.
455
456 #. Get the current value of the PCI configure register::
457
458       setpci -s <XX:XX.X> a8.w
459
460 #. Set bit 8::
461
462       value = value | 0x100
463
464 #. Set the PCI configure register with new value::
465
466       setpci -s <XX:XX.X> a8.w=<value>
467
468 High Performance of Small Packets on 40G NIC
469 --------------------------------------------
470
471 As there might be firmware fixes for performance enhancement in latest version
472 of firmware image, the firmware update might be needed for getting high performance.
473 Check with the local Intel's Network Division application engineers for firmware updates.
474 Users should consult the release notes specific to a DPDK release to identify
475 the validated firmware version for a NIC using the i40e driver.
476
477 Use 16 Bytes RX Descriptor Size
478 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
479
480 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
481 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
482
483 High Performance and per Packet Latency Tradeoff
484 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
485
486 Due to the hardware design, the interrupt signal inside NIC is needed for per
487 packet descriptor write-back. The minimum interval of interrupts could be set
488 at compile time by ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` in configuration files.
489 Though there is a default configuration, the interval could be tuned by the
490 users with that configuration item depends on what the user cares about more,
491 performance or per packet latency.
492
493 Example of getting best performance with l3fwd example
494 ------------------------------------------------------
495
496 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with an
497 Intel server platform and Intel XL710 NICs.
498
499 The example scenario is to get best performance with two Intel XL710 40GbE ports.
500 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
501
502 .. _figure_intel_perf_test_setup:
503
504 .. figure:: img/intel_perf_test_setup.*
505
506    Performance Test Setup
507
508
509 1. Add two Intel XL710 NICs to the platform, and use one port per card to get best performance.
510    The reason for using two NICs is to overcome a PCIe Gen3's limitation since it cannot provide 80G bandwidth
511    for two 40G ports, but two different PCIe Gen3 x8 slot can.
512    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
513
514       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
515       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
516
517 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
518
519 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
520    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
521    are 18-35 and 54-71.
522    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
523    cores from different cores (e.g core18 and core19).
524
525 4. Bind these two ports to igb_uio.
526
527 5. As to XL710 40G port, we need at least two queue pairs to achieve best performance, then two queues per port
528    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
529
530 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
531    Compile the ``l3fwd sample`` with the default lpm mode.
532
533 7. The command line of running l3fwd would be something like the following::
534
535       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
536               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
537
538    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
539    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
540
541 8. Configure the traffic at a traffic generator.
542
543    * Start creating a stream on packet generator.