New upstream version 18.11-rc2
[deb_dpdk.git] / doc / guides / nics / i40e.rst
1 ..  SPDX-License-Identifier: BSD-3-Clause
2     Copyright(c) 2016 Intel Corporation.
3
4 I40E Poll Mode Driver
5 ======================
6
7 The i40e PMD (librte_pmd_i40e) provides poll mode driver support for
8 10/25/40 Gbps Intel® Ethernet 700 Series Network Adapters based on
9 the Intel Ethernet Controller X710/XL710/XXV710 and Intel Ethernet
10 Connection X722 (only support part of features).
11
12
13 Features
14 --------
15
16 Features of the i40e PMD are:
17
18 - Multiple queues for TX and RX
19 - Receiver Side Scaling (RSS)
20 - MAC/VLAN filtering
21 - Packet type information
22 - Flow director
23 - Cloud filter
24 - Checksum offload
25 - VLAN/QinQ stripping and inserting
26 - TSO offload
27 - Promiscuous mode
28 - Multicast mode
29 - Port hardware statistics
30 - Jumbo frames
31 - Link state information
32 - Link flow control
33 - Mirror on port, VLAN and VSI
34 - Interrupt mode for RX
35 - Scattered and gather for TX and RX
36 - Vector Poll mode driver
37 - DCB
38 - VMDQ
39 - SR-IOV VF
40 - Hot plug
41 - IEEE1588/802.1AS timestamping
42 - VF Daemon (VFD) - EXPERIMENTAL
43 - Dynamic Device Personalization (DDP)
44 - Queue region configuration
45 - Virtual Function Port Representors
46
47 Prerequisites
48 -------------
49
50 - Identifying your adapter using `Intel Support
51   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
52
53 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
54
55 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
56   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
57
58 - Upgrade the NVM/FW version following the `Intel® Ethernet NVM Update Tool Quick Usage Guide for Linux
59   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ and `Intel® Ethernet NVM Update Tool: Quick Usage Guide for EFI <https://www.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-efi-usage-guide.html>`_ if needed.
60
61 Recommended Matching List
62 -------------------------
63
64 It is highly recommended to upgrade the i40e kernel driver and firmware to
65 avoid the compatibility issues with i40e PMD. Here is the suggested matching
66 list which has been tested and verified. The detailed information can refer
67 to chapter Tested Platforms/Tested NICs in release notes.
68
69    +--------------+-----------------------+------------------+
70    | DPDK version | Kernel driver version | Firmware version |
71    +==============+=======================+==================+
72    |    18.05     |         2.4.6         |       6.01       |
73    +--------------+-----------------------+------------------+
74    |    18.02     |         2.4.3         |       6.01       |
75    +--------------+-----------------------+------------------+
76    |    17.11     |         2.1.26        |       6.01       |
77    +--------------+-----------------------+------------------+
78    |    17.08     |         2.0.19        |       6.01       |
79    +--------------+-----------------------+------------------+
80    |    17.05     |         1.5.23        |       5.05       |
81    +--------------+-----------------------+------------------+
82    |    17.02     |         1.5.23        |       5.05       |
83    +--------------+-----------------------+------------------+
84    |    16.11     |         1.5.23        |       5.05       |
85    +--------------+-----------------------+------------------+
86    |    16.07     |         1.4.25        |       5.04       |
87    +--------------+-----------------------+------------------+
88    |    16.04     |         1.4.25        |       5.02       |
89    +--------------+-----------------------+------------------+
90
91 Pre-Installation Configuration
92 ------------------------------
93
94 Config File Options
95 ~~~~~~~~~~~~~~~~~~~
96
97 The following options can be modified in the ``config`` file.
98 Please note that enabling debugging options may affect system performance.
99
100 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
101
102   Toggle compilation of the ``librte_pmd_i40e`` driver.
103
104 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
105
106   Toggle display of generic debugging messages.
107
108 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
109
110   Toggle bulk allocation for RX.
111
112 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
113
114   Toggle the use of Vector PMD instead of normal RX/TX path.
115   To enable vPMD for RX, bulk allocation for Rx must be allowed.
116
117 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
118
119   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
120
121 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
122
123   Number of queues reserved for PF.
124
125 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
126
127   Number of queues reserved for each VMDQ Pool.
128
129 Runtime Config Options
130 ~~~~~~~~~~~~~~~~~~~~~~
131
132 - ``Number of Queues per VF`` (default ``4``)
133
134   The number of queue per VF is determined by its host PF. If the PCI address
135   of an i40e PF is aaaa:bb.cc, the number of queues per VF can be configured
136   with EAL parameter like -w aaaa:bb.cc,queue-num-per-vf=n. The value n can be
137   1, 2, 4, 8 or 16. If no such parameter is configured, the number of queues
138   per VF is 4 by default.
139
140 - ``Support multiple driver`` (default ``disable``)
141
142   There was a multiple driver support issue during use of 700 series Ethernet
143   Adapter with both Linux kernel and DPDK PMD. To fix this issue, ``devargs``
144   parameter ``support-multi-driver`` is introduced, for example::
145
146     -w 84:00.0,support-multi-driver=1
147
148   With the above configuration, DPDK PMD will not change global registers, and
149   will switch PF interrupt from IntN to Int0 to avoid interrupt conflict between
150   DPDK and Linux Kernel.
151
152 - ``Support VF Port Representor`` (default ``not enabled``)
153
154   The i40e PF PMD supports the creation of VF port representors for the control
155   and monitoring of i40e virtual function devices. Each port representor
156   corresponds to a single virtual function of that device. Using the ``devargs``
157   option ``representor`` the user can specify which virtual functions to create
158   port representors for on initialization of the PF PMD by passing the VF IDs of
159   the VFs which are required.::
160
161   -w DBDF,representor=[0,1,4]
162
163   Currently hot-plugging of representor ports is not supported so all required
164   representors must be specified on the creation of the PF.
165
166 - ``Use latest supported vector`` (default ``disable``)
167
168   Latest supported vector path may not always get the best perf so vector path was
169   recommended to use only on later platform. But users may want the latest vector path
170   since it can get better perf in some real work loading cases. So ``devargs`` param
171   ``use-latest-supported-vec`` is introduced, for example::
172
173   -w 84:00.0,use-latest-supported-vec=1
174
175 Vector RX Pre-conditions
176 ~~~~~~~~~~~~~~~~~~~~~~~~
177 For Vector RX it is assumed that the number of descriptor rings will be a power
178 of 2. With this pre-condition, the ring pointer can easily scroll back to the
179 head after hitting the tail without a conditional check. In addition Vector RX
180 can use this assumption to do a bit mask using ``ring_size - 1``.
181
182 Driver compilation and testing
183 ------------------------------
184
185 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
186 for details.
187
188
189 SR-IOV: Prerequisites and sample Application Notes
190 --------------------------------------------------
191
192 #. Load the kernel module:
193
194    .. code-block:: console
195
196       modprobe i40e
197
198    Check the output in dmesg:
199
200    .. code-block:: console
201
202       i40e 0000:83:00.1 ens802f0: renamed from eth0
203
204 #. Bring up the PF ports:
205
206    .. code-block:: console
207
208       ifconfig ens802f0 up
209
210 #. Create VF device(s):
211
212    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
213    of the parent PF.
214
215    Example:
216
217    .. code-block:: console
218
219       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
220
221
222 #. Assign VF MAC address:
223
224    Assign MAC address to the VF using iproute2 utility. The syntax is:
225
226    .. code-block:: console
227
228       ip link set <PF netdev id> vf <VF id> mac <macaddr>
229
230    Example:
231
232    .. code-block:: console
233
234       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
235
236 #. Assign VF to VM, and bring up the VM.
237    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
238
239 #. Running testpmd:
240
241    Follow instructions available in the document
242    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
243    to run testpmd.
244
245    Example output:
246
247    .. code-block:: console
248
249       ...
250       EAL: PCI device 0000:83:00.0 on NUMA socket 1
251       EAL: probe driver: 8086:1572 rte_i40e_pmd
252       EAL: PCI memory mapped at 0x7f7f80000000
253       EAL: PCI memory mapped at 0x7f7f80800000
254       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
255       Interactive-mode selected
256       Configuring Port 0 (socket 0)
257       ...
258
259       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
260       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
261
262       ...
263       Port 0: 68:05:CA:26:85:84
264       Checking link statuses...
265       Port 0 Link Up - speed 10000 Mbps - full-duplex
266       Done
267
268       testpmd>
269
270
271 Sample Application Notes
272 ------------------------
273
274 Vlan filter
275 ~~~~~~~~~~~
276
277 Vlan filter only works when Promiscuous mode is off.
278
279 To start ``testpmd``, and add vlan 10 to port 0:
280
281 .. code-block:: console
282
283     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
284     ...
285
286     testpmd> set promisc 0 off
287     testpmd> rx_vlan add 10 0
288
289
290 Flow Director
291 ~~~~~~~~~~~~~
292
293 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
294 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
295
296 The default input set of each flow type is::
297
298    ipv4-other : src_ip_address, dst_ip_address
299    ipv4-frag  : src_ip_address, dst_ip_address
300    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
301    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
302    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
303                 verification_tag
304    ipv6-other : src_ip_address, dst_ip_address
305    ipv6-frag  : src_ip_address, dst_ip_address
306    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
307    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
308    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
309                 verification_tag
310    l2_payload : ether_type
311
312 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
313
314 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
315
316 .. code-block:: console
317
318    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
319                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
320
321 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
322
323 .. code-block:: console
324
325    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
326             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
327             fwd pf queue 1 fd_id 1
328
329 Check the flow director status:
330
331 .. code-block:: console
332
333    testpmd> show port fdir 0
334
335    ######################## FDIR infos for port 0      ####################
336      MODE:   PERFECT
337      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
338                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
339                            l2_payload
340      FLEX PAYLOAD INFO:
341      max_len:       16          payload_limit: 480
342      payload_unit:  2           payload_seg:   3
343      bitmask_unit:  2           bitmask_num:   2
344      MASK:
345        vlan_tci: 0x0000,
346        src_ipv4: 0x00000000,
347        dst_ipv4: 0x00000000,
348        src_port: 0x0000,
349        dst_port: 0x0000
350        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
351        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
352      FLEX PAYLOAD SRC OFFSET:
353        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
354        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
355        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
356      FLEX MASK CFG:
357        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
358        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
359        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
360        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
361        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
362        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
363        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
364        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
365        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
366        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
367        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
368      guarant_count: 1           best_count:    0
369      guarant_space: 512         best_space:    7168
370      collision:     0           free:          0
371      maxhash:       0           maxlen:        0
372      add:           0           remove:        0
373      f_add:         0           f_remove:      0
374
375
376 Delete all flow director rules on a port:
377
378 .. code-block:: console
379
380    testpmd> flush_flow_director 0
381
382 Floating VEB
383 ~~~~~~~~~~~~~
384
385 The Intel® Ethernet 700 Series support a feature called
386 "Floating VEB".
387
388 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
389 for functionality that allows local switching between virtual endpoints within
390 a physical endpoint and also with an external bridge/network.
391
392 A "Floating" VEB doesn't have an uplink connection to the outside world so all
393 switching is done internally and remains within the host. As such, this
394 feature provides security benefits.
395
396 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
397 cannot forward packets when the physical link is down. Floating VEBs don't need
398 to connect to the NIC port so they can still forward traffic from VF to VF
399 even when the physical link is down.
400
401 Therefore, with this feature enabled VFs can be limited to communicating with
402 each other but not an outside network, and they can do so even when there is
403 no physical uplink on the associated NIC port.
404
405 To enable this feature, the user should pass a ``devargs`` parameter to the
406 EAL, for example::
407
408     -w 84:00.0,enable_floating_veb=1
409
410 In this configuration the PMD will use the floating VEB feature for all the
411 VFs created by this PF device.
412
413 Alternatively, the user can specify which VFs need to connect to this floating
414 VEB using the ``floating_veb_list`` argument::
415
416     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
417
418 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
419 while other VFs connect to the normal VEB.
420
421 The current implementation only supports one floating VEB and one regular
422 VEB. VFs can connect to a floating VEB or a regular VEB according to the
423 configuration passed on the EAL command line.
424
425 The floating VEB functionality requires a NIC firmware version of 5.0
426 or greater.
427
428 Dynamic Device Personalization (DDP)
429 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
430
431 The Intel® Ethernet 700 Series except for the Intel Ethernet Connection
432 X722 support a feature called "Dynamic Device Personalization (DDP)",
433 which is used to configure hardware by downloading a profile to support
434 protocols/filters which are not supported by default. The DDP
435 functionality requires a NIC firmware version of 6.0 or greater.
436
437 Current implementation supports GTP-C/GTP-U/PPPoE/PPPoL2TP,
438 steering can be used with rte_flow API.
439
440 GTPv1 package is released, and it can be downloaded from
441 https://downloadcenter.intel.com/download/27587.
442
443 PPPoE package is released, and it can be downloaded from
444 https://downloadcenter.intel.com/download/28040.
445
446 Load a profile which supports GTP and store backup profile:
447
448 .. code-block:: console
449
450    testpmd> ddp add 0 ./gtp.pkgo,./backup.pkgo
451
452 Delete a GTP profile and restore backup profile:
453
454 .. code-block:: console
455
456    testpmd> ddp del 0 ./backup.pkgo
457
458 Get loaded DDP package info list:
459
460 .. code-block:: console
461
462    testpmd> ddp get list 0
463
464 Display information about a GTP profile:
465
466 .. code-block:: console
467
468    testpmd> ddp get info ./gtp.pkgo
469
470 Input set configuration
471 ~~~~~~~~~~~~~~~~~~~~~~~
472 Input set for any PCTYPE can be configured with user defined configuration,
473 For example, to use only 48bit prefix for IPv6 src address for IPv6 TCP RSS:
474
475 .. code-block:: console
476
477    testpmd> port config 0 pctype 43 hash_inset clear all
478    testpmd> port config 0 pctype 43 hash_inset set field 13
479    testpmd> port config 0 pctype 43 hash_inset set field 14
480    testpmd> port config 0 pctype 43 hash_inset set field 15
481
482 Queue region configuration
483 ~~~~~~~~~~~~~~~~~~~~~~~~~~~
484 The Intel® Ethernet 700 Series supports a feature of queue regions
485 configuration for RSS in the PF, so that different traffic classes or
486 different packet classification types can be separated to different
487 queues in different queue regions. There is an API for configuration
488 of queue regions in RSS with a command line. It can parse the parameters
489 of the region index, queue number, queue start index, user priority, traffic
490 classes and so on. Depending on commands from the command line, it will call
491 i40e private APIs and start the process of setting or flushing the queue
492 region configuration. As this feature is specific for i40e only private
493 APIs are used. These new ``test_pmd`` commands are as shown below. For
494 details please refer to :doc:`../testpmd_app_ug/index`.
495
496 .. code-block:: console
497
498    testpmd> set port (port_id) queue-region region_id (value) \
499                 queue_start_index (value) queue_num (value)
500    testpmd> set port (port_id) queue-region region_id (value) flowtype (value)
501    testpmd> set port (port_id) queue-region UP (value) region_id (value)
502    testpmd> set port (port_id) queue-region flush (on|off)
503    testpmd> show port (port_id) queue-region
504
505 Limitations or Known issues
506 ---------------------------
507
508 MPLS packet classification
509 ~~~~~~~~~~~~~~~~~~~~~~~~~~
510
511 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
512 The L2 Payload flow type in flow director can be used to classify MPLS packet
513 by using a command in testpmd like:
514
515    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
516             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
517
518 With the NIC firmware version 5.0 or greater, some limited MPLS support
519 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
520 new packet type, no classification or offload are possible. With this change,
521 L2 Payload flow type in flow director cannot be used to classify MPLS packet
522 as with previous firmware versions. Meanwhile, the Ethertype filter can be
523 used to classify MPLS packet by using a command in testpmd like:
524
525    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
526             0x8847 fwd queue <M>
527
528 16 Byte RX Descriptor setting on DPDK VF
529 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
530
531 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
532 interface for VF to request the RX descriptor mode, also no interface to notify
533 VF its own RX descriptor mode.
534 For all available versions of the i40e driver, these drivers don't support 16
535 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
536 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
537 descriptor. The reason is that the RX descriptor is already set to 32 byte by
538 the i40e kernel driver. That is to say, user should keep
539 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
540 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
541 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
542 byte, as the PF driver.
543
544 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
545 descriptor mode. Or the VF RX will not work.
546
547 Receive packets with Ethertype 0x88A8
548 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
549
550 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
551 only when floating VEB is disabled.
552
553 Incorrect Rx statistics when packet is oversize
554 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
555
556 When a packet is over maximum frame size, the packet is dropped.
557 However, the Rx statistics, when calling `rte_eth_stats_get` incorrectly
558 shows it as received.
559
560 VF & TC max bandwidth setting
561 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
562
563 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
564 The behavior is different when handling per VF and per TC max bandwidth setting.
565 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
566 enabled. If so, return failure.
567 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
568 is enabled. If so, disable per VF max bandwidth and continue with per TC max
569 bandwidth setting.
570
571 TC TX scheduling mode setting
572 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
573
574 There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
575 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
576 It means if APP has set the max bandwidth for that TC, it comes to no
577 effect.
578 It's suggested to set the strict priority mode for a TC that is latency
579 sensitive but no consuming much bandwidth.
580
581 VF performance is impacted by PCI extended tag setting
582 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
583
584 To reach maximum NIC performance in the VF the PCI extended tag must be
585 enabled. The DPDK i40e PF driver will set this feature during initialization,
586 but the kernel PF driver does not. So when running traffic on a VF which is
587 managed by the kernel PF driver, a significant NIC performance downgrade has
588 been observed (for 64 byte packets, there is about 25% line-rate downgrade for
589 a 25GbE device and about 35% for a 40GbE device).
590
591 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
592 tag if it detects that the device supports it. So by default, this is not an
593 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
594 enabled using the steps below.
595
596 #. Get the current value of the PCI configure register::
597
598       setpci -s <XX:XX.X> a8.w
599
600 #. Set bit 8::
601
602       value = value | 0x100
603
604 #. Set the PCI configure register with new value::
605
606       setpci -s <XX:XX.X> a8.w=<value>
607
608 Vlan strip of VF
609 ~~~~~~~~~~~~~~~~
610
611 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
612
613 DCB function
614 ~~~~~~~~~~~~
615
616 DCB works only when RSS is enabled.
617
618 Global configuration warning
619 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~
620
621 I40E PMD will set some global registers to enable some function or set some
622 configure. Then when using different ports of the same NIC with Linux kernel
623 and DPDK, the port with Linux kernel will be impacted by the port with DPDK.
624 For example, register I40E_GL_SWT_L2TAGCTRL is used to control L2 tag, i40e
625 PMD uses I40E_GL_SWT_L2TAGCTRL to set vlan TPID. If setting TPID in port A
626 with DPDK, then the configuration will also impact port B in the NIC with
627 kernel driver, which don't want to use the TPID.
628 So PMD reports warning to clarify what is changed by writing global register.
629
630 High Performance of Small Packets on 40GbE NIC
631 ----------------------------------------------
632
633 As there might be firmware fixes for performance enhancement in latest version
634 of firmware image, the firmware update might be needed for getting high performance.
635 Check the Intel support website for the latest firmware updates.
636 Users should consult the release notes specific to a DPDK release to identify
637 the validated firmware version for a NIC using the i40e driver.
638
639 Use 16 Bytes RX Descriptor Size
640 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
641
642 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
643 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
644
645 Example of getting best performance with l3fwd example
646 ------------------------------------------------------
647
648 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with a
649 server with Intel Xeon processors and Intel Ethernet CNA XL710.
650
651 The example scenario is to get best performance with two Intel Ethernet CNA XL710 40GbE ports.
652 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
653
654 .. _figure_intel_perf_test_setup:
655
656 .. figure:: img/intel_perf_test_setup.*
657
658    Performance Test Setup
659
660
661 1. Add two Intel Ethernet CNA XL710 to the platform, and use one port per card to get best performance.
662    The reason for using two NICs is to overcome a PCIe v3.0 limitation since it cannot provide 80GbE bandwidth
663    for two 40GbE ports, but two different PCIe v3.0 x8 slot can.
664    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
665
666       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
667       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
668
669 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
670
671 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
672    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
673    are 18-35 and 54-71.
674    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
675    cores from different cores (e.g core18 and core19).
676
677 4. Bind these two ports to igb_uio.
678
679 5. As to Intel Ethernet CNA XL710 40GbE port, we need at least two queue pairs to achieve best performance, then two queues per port
680    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
681
682 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
683    Compile the ``l3fwd sample`` with the default lpm mode.
684
685 7. The command line of running l3fwd would be something like the following::
686
687       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
688               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
689
690    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
691    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
692
693 8. Configure the traffic at a traffic generator.
694
695    * Start creating a stream on packet generator.