New upstream version 17.11-rc3
[deb_dpdk.git] / doc / guides / nics / i40e.rst
1 ..  BSD LICENSE
2     Copyright(c) 2016 Intel Corporation. All rights reserved.
3     All rights reserved.
4
5     Redistribution and use in source and binary forms, with or without
6     modification, are permitted provided that the following conditions
7     are met:
8
9     * Redistributions of source code must retain the above copyright
10     notice, this list of conditions and the following disclaimer.
11     * Redistributions in binary form must reproduce the above copyright
12     notice, this list of conditions and the following disclaimer in
13     the documentation and/or other materials provided with the
14     distribution.
15     * Neither the name of Intel Corporation nor the names of its
16     contributors may be used to endorse or promote products derived
17     from this software without specific prior written permission.
18
19     THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
20     "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
21     LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
22     A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
23     OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
24     SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
25     LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
26     DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
27     THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
28     (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
29     OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
30
31 I40E Poll Mode Driver
32 ======================
33
34 The I40E PMD (librte_pmd_i40e) provides poll mode driver support
35 for the Intel X710/XL710/X722 10/40 Gbps family of adapters.
36
37
38 Features
39 --------
40
41 Features of the I40E PMD are:
42
43 - Multiple queues for TX and RX
44 - Receiver Side Scaling (RSS)
45 - MAC/VLAN filtering
46 - Packet type information
47 - Flow director
48 - Cloud filter
49 - Checksum offload
50 - VLAN/QinQ stripping and inserting
51 - TSO offload
52 - Promiscuous mode
53 - Multicast mode
54 - Port hardware statistics
55 - Jumbo frames
56 - Link state information
57 - Link flow control
58 - Mirror on port, VLAN and VSI
59 - Interrupt mode for RX
60 - Scattered and gather for TX and RX
61 - Vector Poll mode driver
62 - DCB
63 - VMDQ
64 - SR-IOV VF
65 - Hot plug
66 - IEEE1588/802.1AS timestamping
67 - VF Daemon (VFD) - EXPERIMENTAL
68
69
70 Prerequisites
71 -------------
72
73 - Identifying your adapter using `Intel Support
74   <http://www.intel.com/support>`_ and get the latest NVM/FW images.
75
76 - Follow the DPDK :ref:`Getting Started Guide for Linux <linux_gsg>` to setup the basic DPDK environment.
77
78 - To get better performance on Intel platforms, please follow the "How to get best performance with NICs on Intel platforms"
79   section of the :ref:`Getting Started Guide for Linux <linux_gsg>`.
80
81 - Upgrade the NVM/FW version following the `IntelĀ® Ethernet NVM Update Tool Quick Usage Guide for Linux
82   <https://www-ssl.intel.com/content/www/us/en/embedded/products/networking/nvm-update-tool-quick-linux-usage-guide.html>`_ if needed.
83
84 Pre-Installation Configuration
85 ------------------------------
86
87 Config File Options
88 ~~~~~~~~~~~~~~~~~~~
89
90 The following options can be modified in the ``config`` file.
91 Please note that enabling debugging options may affect system performance.
92
93 - ``CONFIG_RTE_LIBRTE_I40E_PMD`` (default ``y``)
94
95   Toggle compilation of the ``librte_pmd_i40e`` driver.
96
97 - ``CONFIG_RTE_LIBRTE_I40E_DEBUG_*`` (default ``n``)
98
99   Toggle display of generic debugging messages.
100
101 - ``CONFIG_RTE_LIBRTE_I40E_RX_ALLOW_BULK_ALLOC`` (default ``y``)
102
103   Toggle bulk allocation for RX.
104
105 - ``CONFIG_RTE_LIBRTE_I40E_INC_VECTOR`` (default ``n``)
106
107   Toggle the use of Vector PMD instead of normal RX/TX path.
108   To enable vPMD for RX, bulk allocation for Rx must be allowed.
109
110 - ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` (default ``n``)
111
112   Toggle to use a 16-byte RX descriptor, by default the RX descriptor is 32 byte.
113
114 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_PF`` (default ``64``)
115
116   Number of queues reserved for PF.
117
118 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VF`` (default ``4``)
119
120   Number of queues reserved for each SR-IOV VF.
121
122 - ``CONFIG_RTE_LIBRTE_I40E_QUEUE_NUM_PER_VM`` (default ``4``)
123
124   Number of queues reserved for each VMDQ Pool.
125
126 - ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` (default ``-1``)
127
128   Interrupt Throttling interval.
129
130
131 Driver compilation and testing
132 ------------------------------
133
134 Refer to the document :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
135 for details.
136
137
138 SR-IOV: Prerequisites and sample Application Notes
139 --------------------------------------------------
140
141 #. Load the kernel module:
142
143    .. code-block:: console
144
145       modprobe i40e
146
147    Check the output in dmesg:
148
149    .. code-block:: console
150
151       i40e 0000:83:00.1 ens802f0: renamed from eth0
152
153 #. Bring up the PF ports:
154
155    .. code-block:: console
156
157       ifconfig ens802f0 up
158
159 #. Create VF device(s):
160
161    Echo the number of VFs to be created into the ``sriov_numvfs`` sysfs entry
162    of the parent PF.
163
164    Example:
165
166    .. code-block:: console
167
168       echo 2 > /sys/devices/pci0000:00/0000:00:03.0/0000:81:00.0/sriov_numvfs
169
170
171 #. Assign VF MAC address:
172
173    Assign MAC address to the VF using iproute2 utility. The syntax is:
174
175    .. code-block:: console
176
177       ip link set <PF netdev id> vf <VF id> mac <macaddr>
178
179    Example:
180
181    .. code-block:: console
182
183       ip link set ens802f0 vf 0 mac a0:b0:c0:d0:e0:f0
184
185 #. Assign VF to VM, and bring up the VM.
186    Please see the documentation for the *I40E/IXGBE/IGB Virtual Function Driver*.
187
188 #. Running testpmd:
189
190    Follow instructions available in the document
191    :ref:`compiling and testing a PMD for a NIC <pmd_build_and_test>`
192    to run testpmd.
193
194    Example output:
195
196    .. code-block:: console
197
198       ...
199       EAL: PCI device 0000:83:00.0 on NUMA socket 1
200       EAL: probe driver: 8086:1572 rte_i40e_pmd
201       EAL: PCI memory mapped at 0x7f7f80000000
202       EAL: PCI memory mapped at 0x7f7f80800000
203       PMD: eth_i40e_dev_init(): FW 5.0 API 1.5 NVM 05.00.02 eetrack 8000208a
204       Interactive-mode selected
205       Configuring Port 0 (socket 0)
206       ...
207
208       PMD: i40e_dev_rx_queue_setup(): Rx Burst Bulk Alloc Preconditions are
209       satisfied.Rx Burst Bulk Alloc function will be used on port=0, queue=0.
210
211       ...
212       Port 0: 68:05:CA:26:85:84
213       Checking link statuses...
214       Port 0 Link Up - speed 10000 Mbps - full-duplex
215       Done
216
217       testpmd>
218
219
220 Sample Application Notes
221 ------------------------
222
223 Vlan filter
224 ~~~~~~~~~~~
225
226 Vlan filter only works when Promiscuous mode is off.
227
228 To start ``testpmd``, and add vlan 10 to port 0:
229
230 .. code-block:: console
231
232     ./app/testpmd -l 0-15 -n 4 -- -i --forward-mode=mac
233     ...
234
235     testpmd> set promisc 0 off
236     testpmd> rx_vlan add 10 0
237
238
239 Flow Director
240 ~~~~~~~~~~~~~
241
242 The Flow Director works in receive mode to identify specific flows or sets of flows and route them to specific queues.
243 The Flow Director filters can match the different fields for different type of packet: flow type, specific input set per flow type and the flexible payload.
244
245 The default input set of each flow type is::
246
247    ipv4-other : src_ip_address, dst_ip_address
248    ipv4-frag  : src_ip_address, dst_ip_address
249    ipv4-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
250    ipv4-udp   : src_ip_address, dst_ip_address, src_port, dst_port
251    ipv4-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
252                 verification_tag
253    ipv6-other : src_ip_address, dst_ip_address
254    ipv6-frag  : src_ip_address, dst_ip_address
255    ipv6-tcp   : src_ip_address, dst_ip_address, src_port, dst_port
256    ipv6-udp   : src_ip_address, dst_ip_address, src_port, dst_port
257    ipv6-sctp  : src_ip_address, dst_ip_address, src_port, dst_port,
258                 verification_tag
259    l2_payload : ether_type
260
261 The flex payload is selected from offset 0 to 15 of packet's payload by default, while it is masked out from matching.
262
263 Start ``testpmd`` with ``--disable-rss`` and ``--pkt-filter-mode=perfect``:
264
265 .. code-block:: console
266
267    ./app/testpmd -l 0-15 -n 4 -- -i --disable-rss --pkt-filter-mode=perfect \
268                  --rxq=8 --txq=8 --nb-cores=8 --nb-ports=1
269
270 Add a rule to direct ``ipv4-udp`` packet whose ``dst_ip=2.2.2.5, src_ip=2.2.2.3, src_port=32, dst_port=32`` to queue 1:
271
272 .. code-block:: console
273
274    testpmd> flow_director_filter 0 mode IP add flow ipv4-udp  \
275             src 2.2.2.3 32 dst 2.2.2.5 32 vlan 0 flexbytes () \
276             fwd pf queue 1 fd_id 1
277
278 Check the flow director status:
279
280 .. code-block:: console
281
282    testpmd> show port fdir 0
283
284    ######################## FDIR infos for port 0      ####################
285      MODE:   PERFECT
286      SUPPORTED FLOW TYPE:  ipv4-frag ipv4-tcp ipv4-udp ipv4-sctp ipv4-other
287                            ipv6-frag ipv6-tcp ipv6-udp ipv6-sctp ipv6-other
288                            l2_payload
289      FLEX PAYLOAD INFO:
290      max_len:       16          payload_limit: 480
291      payload_unit:  2           payload_seg:   3
292      bitmask_unit:  2           bitmask_num:   2
293      MASK:
294        vlan_tci: 0x0000,
295        src_ipv4: 0x00000000,
296        dst_ipv4: 0x00000000,
297        src_port: 0x0000,
298        dst_port: 0x0000
299        src_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000,
300        dst_ipv6: 0x00000000,0x00000000,0x00000000,0x00000000
301      FLEX PAYLOAD SRC OFFSET:
302        L2_PAYLOAD:    0      1      2      3      4      5      6  ...
303        L3_PAYLOAD:    0      1      2      3      4      5      6  ...
304        L4_PAYLOAD:    0      1      2      3      4      5      6  ...
305      FLEX MASK CFG:
306        ipv4-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
307        ipv4-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
308        ipv4-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
309        ipv4-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
310        ipv4-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
311        ipv6-udp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
312        ipv6-tcp:    00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
313        ipv6-sctp:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
314        ipv6-other:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
315        ipv6-frag:   00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
316        l2_payload:  00 00 00 00 00 00 00 00 00 00 00 00 00 00 00 00
317      guarant_count: 1           best_count:    0
318      guarant_space: 512         best_space:    7168
319      collision:     0           free:          0
320      maxhash:       0           maxlen:        0
321      add:           0           remove:        0
322      f_add:         0           f_remove:      0
323
324
325 Delete all flow director rules on a port:
326
327 .. code-block:: console
328
329    testpmd> flush_flow_director 0
330
331 Floating VEB
332 ~~~~~~~~~~~~~
333
334 The IntelĀ® Ethernet Controller X710 and XL710 Family support a feature called
335 "Floating VEB".
336
337 A Virtual Ethernet Bridge (VEB) is an IEEE Edge Virtual Bridging (EVB) term
338 for functionality that allows local switching between virtual endpoints within
339 a physical endpoint and also with an external bridge/network.
340
341 A "Floating" VEB doesn't have an uplink connection to the outside world so all
342 switching is done internally and remains within the host. As such, this
343 feature provides security benefits.
344
345 In addition, a Floating VEB overcomes a limitation of normal VEBs where they
346 cannot forward packets when the physical link is down. Floating VEBs don't need
347 to connect to the NIC port so they can still forward traffic from VF to VF
348 even when the physical link is down.
349
350 Therefore, with this feature enabled VFs can be limited to communicating with
351 each other but not an outside network, and they can do so even when there is
352 no physical uplink on the associated NIC port.
353
354 To enable this feature, the user should pass a ``devargs`` parameter to the
355 EAL, for example::
356
357     -w 84:00.0,enable_floating_veb=1
358
359 In this configuration the PMD will use the floating VEB feature for all the
360 VFs created by this PF device.
361
362 Alternatively, the user can specify which VFs need to connect to this floating
363 VEB using the ``floating_veb_list`` argument::
364
365     -w 84:00.0,enable_floating_veb=1,floating_veb_list=1;3-4
366
367 In this example ``VF1``, ``VF3`` and ``VF4`` connect to the floating VEB,
368 while other VFs connect to the normal VEB.
369
370 The current implementation only supports one floating VEB and one regular
371 VEB. VFs can connect to a floating VEB or a regular VEB according to the
372 configuration passed on the EAL command line.
373
374 The floating VEB functionality requires a NIC firmware version of 5.0
375 or greater.
376
377
378 Limitations or Known issues
379 ---------------------------
380
381 MPLS packet classification on X710/XL710
382 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
383
384 For firmware versions prior to 5.0, MPLS packets are not recognized by the NIC.
385 The L2 Payload flow type in flow director can be used to classify MPLS packet
386 by using a command in testpmd like:
387
388    testpmd> flow_director_filter 0 mode IP add flow l2_payload ether \
389             0x8847 flexbytes () fwd pf queue <N> fd_id <M>
390
391 With the NIC firmware version 5.0 or greater, some limited MPLS support
392 is added: Native MPLS (MPLS in Ethernet) skip is implemented, while no
393 new packet type, no classification or offload are possible. With this change,
394 L2 Payload flow type in flow director cannot be used to classify MPLS packet
395 as with previous firmware versions. Meanwhile, the Ethertype filter can be
396 used to classify MPLS packet by using a command in testpmd like:
397
398    testpmd> ethertype_filter 0 add mac_ignr 00:00:00:00:00:00 ethertype \
399             0x8847 fwd queue <M>
400
401 16 Byte RX Descriptor setting on DPDK VF
402 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
403
404 Currently the VF's RX descriptor mode is decided by PF. There's no PF-VF
405 interface for VF to request the RX descriptor mode, also no interface to notify
406 VF its own RX descriptor mode.
407 For all available versions of the i40e driver, these drivers don't support 16
408 byte RX descriptor. If the Linux i40e kernel driver is used as host driver,
409 while DPDK i40e PMD is used as the VF driver, DPDK cannot choose 16 byte receive
410 descriptor. The reason is that the RX descriptor is already set to 32 byte by
411 the i40e kernel driver. That is to say, user should keep
412 ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC=n`` in config file.
413 In the future, if the Linux i40e driver supports 16 byte RX descriptor, user
414 should make sure the DPDK VF uses the same RX descriptor mode, 16 byte or 32
415 byte, as the PF driver.
416
417 The same rule for DPDK PF + DPDK VF. The PF and VF should use the same RX
418 descriptor mode. Or the VF RX will not work.
419
420 Receive packets with Ethertype 0x88A8
421 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
422
423 Due to the FW limitation, PF can receive packets with Ethertype 0x88A8
424 only when floating VEB is disabled.
425
426 Incorrect Rx statistics when packet is oversize
427 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
428
429 When a packet is over maximum frame size, the packet is dropped.
430 However the Rx statistics, when calling `rte_eth_stats_get` incorrectly
431 shows it as received.
432
433 VF & TC max bandwidth setting
434 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
435
436 The per VF max bandwidth and per TC max bandwidth cannot be enabled in parallel.
437 The dehavior is different when handling per VF and per TC max bandwidth setting.
438 When enabling per VF max bandwidth, SW will check if per TC max bandwidth is
439 enabled. If so, return failure.
440 When enabling per TC max bandwidth, SW will check if per VF max bandwidth
441 is enabled. If so, disable per VF max bandwidth and continue with per TC max
442 bandwidth setting.
443
444 TC TX scheduling mode setting
445 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
446
447 There're 2 TX scheduling modes for TCs, round robin and strict priority mode.
448 If a TC is set to strict priority mode, it can consume unlimited bandwidth.
449 It means if APP has set the max bandwidth for that TC, it comes to no
450 effect.
451 It's suggested to set the strict priority mode for a TC that is latency
452 sensitive but no consuming much bandwidth.
453
454 VF performance is impacted by PCI extended tag setting
455 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
456
457 To reach maximum NIC performance in the VF the PCI extended tag must be
458 enabled. The DPDK I40E PF driver will set this feature during initialization,
459 but the kernel PF driver does not. So when running traffic on a VF which is
460 managed by the kernel PF driver, a significant NIC performance downgrade has
461 been observed (for 64 byte packets, there is about 25% linerate downgrade for
462 a 25G device and about 35% for a 40G device).
463
464 For kernel version >= 4.11, the kernel's PCI driver will enable the extended
465 tag if it detects that the device supports it. So by default, this is not an
466 issue. For kernels <= 4.11 or when the PCI extended tag is disabled it can be
467 enabled using the steps below.
468
469 #. Get the current value of the PCI configure register::
470
471       setpci -s <XX:XX.X> a8.w
472
473 #. Set bit 8::
474
475       value = value | 0x100
476
477 #. Set the PCI configure register with new value::
478
479       setpci -s <XX:XX.X> a8.w=<value>
480
481 Vlan strip of VF
482 ~~~~~~~~~~~~~~~~
483
484 The VF vlan strip function is only supported in the i40e kernel driver >= 2.1.26.
485
486 High Performance of Small Packets on 40G NIC
487 --------------------------------------------
488
489 As there might be firmware fixes for performance enhancement in latest version
490 of firmware image, the firmware update might be needed for getting high performance.
491 Check with the local Intel's Network Division application engineers for firmware updates.
492 Users should consult the release notes specific to a DPDK release to identify
493 the validated firmware version for a NIC using the i40e driver.
494
495 Use 16 Bytes RX Descriptor Size
496 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
497
498 As i40e PMD supports both 16 and 32 bytes RX descriptor sizes, and 16 bytes size can provide helps to high performance of small packets.
499 Configuration of ``CONFIG_RTE_LIBRTE_I40E_16BYTE_RX_DESC`` in config files can be changed to use 16 bytes size RX descriptors.
500
501 High Performance and per Packet Latency Tradeoff
502 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
503
504 Due to the hardware design, the interrupt signal inside NIC is needed for per
505 packet descriptor write-back. The minimum interval of interrupts could be set
506 at compile time by ``CONFIG_RTE_LIBRTE_I40E_ITR_INTERVAL`` in configuration files.
507 Though there is a default configuration, the interval could be tuned by the
508 users with that configuration item depends on what the user cares about more,
509 performance or per packet latency.
510
511 Example of getting best performance with l3fwd example
512 ------------------------------------------------------
513
514 The following is an example of running the DPDK ``l3fwd`` sample application to get high performance with an
515 Intel server platform and Intel XL710 NICs.
516
517 The example scenario is to get best performance with two Intel XL710 40GbE ports.
518 See :numref:`figure_intel_perf_test_setup` for the performance test setup.
519
520 .. _figure_intel_perf_test_setup:
521
522 .. figure:: img/intel_perf_test_setup.*
523
524    Performance Test Setup
525
526
527 1. Add two Intel XL710 NICs to the platform, and use one port per card to get best performance.
528    The reason for using two NICs is to overcome a PCIe Gen3's limitation since it cannot provide 80G bandwidth
529    for two 40G ports, but two different PCIe Gen3 x8 slot can.
530    Refer to the sample NICs output above, then we can select ``82:00.0`` and ``85:00.0`` as test ports::
531
532       82:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
533       85:00.0 Ethernet [0200]: Intel XL710 for 40GbE QSFP+ [8086:1583]
534
535 2. Connect the ports to the traffic generator. For high speed testing, it's best to use a hardware traffic generator.
536
537 3. Check the PCI devices numa node (socket id) and get the cores number on the exact socket id.
538    In this case, ``82:00.0`` and ``85:00.0`` are both in socket 1, and the cores on socket 1 in the referenced platform
539    are 18-35 and 54-71.
540    Note: Don't use 2 logical cores on the same core (e.g core18 has 2 logical cores, core18 and core54), instead, use 2 logical
541    cores from different cores (e.g core18 and core19).
542
543 4. Bind these two ports to igb_uio.
544
545 5. As to XL710 40G port, we need at least two queue pairs to achieve best performance, then two queues per port
546    will be required, and each queue pair will need a dedicated CPU core for receiving/transmitting packets.
547
548 6. The DPDK sample application ``l3fwd`` will be used for performance testing, with using two ports for bi-directional forwarding.
549    Compile the ``l3fwd sample`` with the default lpm mode.
550
551 7. The command line of running l3fwd would be something like the following::
552
553       ./l3fwd -l 18-21 -n 4 -w 82:00.0 -w 85:00.0 \
554               -- -p 0x3 --config '(0,0,18),(0,1,19),(1,0,20),(1,1,21)'
555
556    This means that the application uses core 18 for port 0, queue pair 0 forwarding, core 19 for port 0, queue pair 1 forwarding,
557    core 20 for port 1, queue pair 0 forwarding, and core 21 for port 1, queue pair 1 forwarding.
558
559 8. Configure the traffic at a traffic generator.
560
561    * Start creating a stream on packet generator.