New upstream version 17.11-rc3
[deb_dpdk.git] / doc / guides / nics / sfc_efx.rst
1 ..  BSD LICENSE
2     Copyright (c) 2016 Solarflare Communications Inc.
3     All rights reserved.
4
5     This software was jointly developed between OKTET Labs (under contract
6     for Solarflare) and Solarflare Communications, Inc.
7
8     Redistribution and use in source and binary forms, with or without
9     modification, are permitted provided that the following conditions are met:
10
11     1. Redistributions of source code must retain the above copyright notice,
12        this list of conditions and the following disclaimer.
13     2. Redistributions in binary form must reproduce the above copyright notice,
14        this list of conditions and the following disclaimer in the documentation
15        and/or other materials provided with the distribution.
16
17     THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS "AS IS"
18     AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT LIMITED TO,
19     THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR A PARTICULAR
20     PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT OWNER OR
21     CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL, SPECIAL,
22     EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT LIMITED TO,
23     PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE, DATA, OR PROFITS;
24     OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY THEORY OF LIABILITY,
25     WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT (INCLUDING NEGLIGENCE OR
26     OTHERWISE) ARISING IN ANY WAY OUT OF THE USE OF THIS SOFTWARE,
27     EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
28
29 Solarflare libefx-based Poll Mode Driver
30 ========================================
31
32 The SFC EFX PMD (**librte_pmd_sfc_efx**) provides poll mode driver support
33 for **Solarflare SFN7xxx and SFN8xxx** family of 10/40 Gbps adapters.
34 SFC EFX PMD has support for the latest Linux and FreeBSD operating systems.
35
36 More information can be found at `Solarflare Communications website
37 <http://solarflare.com>`_.
38
39
40 Features
41 --------
42
43 SFC EFX PMD has support for:
44
45 - Multiple transmit and receive queues
46
47 - Link state information including link status change interrupt
48
49 - IPv4/IPv6 TCP/UDP transmit checksum offload
50
51 - Port hardware statistics
52
53 - Extended statistics (see Solarflare Server Adapter User's Guide for
54   the statistics description)
55
56 - Basic flow control
57
58 - MTU update
59
60 - Jumbo frames up to 9K
61
62 - Promiscuous mode
63
64 - Allmulticast mode
65
66 - TCP segmentation offload (TSO)
67
68 - Multicast MAC filter
69
70 - IPv4/IPv6 TCP/UDP receive checksum offload
71
72 - Received packet type information
73
74 - Receive side scaling (RSS)
75
76 - RSS hash
77
78 - Scattered Rx DMA for packet that are larger that a single Rx descriptor
79
80 - Deferred receive and transmit queue start
81
82 - Transmit VLAN insertion (if running firmware variant supports it)
83
84 - Flow API
85
86
87 Non-supported Features
88 ----------------------
89
90 The features not yet supported include:
91
92 - Receive queue interupts
93
94 - Priority-based flow control
95
96 - Loopback
97
98 - Configurable RX CRC stripping (always stripped)
99
100 - Header split on receive
101
102 - VLAN filtering
103
104 - VLAN stripping
105
106 - LRO
107
108
109 Limitations
110 -----------
111
112 Due to requirements on receive buffer alignment and usage of the receive
113 buffer for the auxiliary packet information provided by the NIC up to
114 extra 269 (14 bytes prefix plus up to 255 bytes for end padding) bytes may be
115 required in the receive buffer.
116 It should be taken into account when mbuf pool for receive is created.
117
118
119 Flow API support
120 ----------------
121
122 Supported attributes:
123
124 - Ingress
125
126 Supported pattern items:
127
128 - VOID
129
130 - ETH (exact match of source/destination addresses, individual/group match
131   of destination address, EtherType)
132
133 - VLAN (exact match of VID, double-tagging is supported)
134
135 - IPV4 (exact match of source/destination addresses,
136   IP transport protocol)
137
138 - IPV6 (exact match of source/destination addresses,
139   IP transport protocol)
140
141 - TCP (exact match of source/destination ports)
142
143 - UDP (exact match of source/destination ports)
144
145 Supported actions:
146
147 - VOID
148
149 - QUEUE
150
151 - RSS
152
153 Validating flow rules depends on the firmware variant.
154
155 Ethernet destinaton individual/group match
156 ~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~~
157
158 Ethernet item supports I/G matching, if only the corresponding bit is set
159 in the mask of destination address. If destinaton address in the spec is
160 multicast, it matches all multicast (and broadcast) packets, oherwise it
161 matches unicast packets that are not filtered by other flow rules.
162
163
164 Supported NICs
165 --------------
166
167 - Solarflare Flareon [Ultra] Server Adapters:
168
169    - Solarflare SFN8522 Dual Port SFP+ Server Adapter
170
171    - Solarflare SFN8542 Dual Port QSFP+ Server Adapter
172
173    - Solarflare SFN7002F Dual Port SFP+ Server Adapter
174
175    - Solarflare SFN7004F Quad Port SFP+ Server Adapter
176
177    - Solarflare SFN7042Q Dual Port QSFP+ Server Adapter
178
179    - Solarflare SFN7122F Dual Port SFP+ Server Adapter
180
181    - Solarflare SFN7124F Quad Port SFP+ Server Adapter
182
183    - Solarflare SFN7142Q Dual Port QSFP+ Server Adapter
184
185    - Solarflare SFN7322F Precision Time Synchronization Server Adapter
186
187
188 Prerequisites
189 -------------
190
191 - Requires firmware version:
192
193    - SFN7xxx: **4.7.1.1001** or higher
194
195    - SFN8xxx: **6.0.2.1004** or higher
196
197 Visit `Solarflare Support Downloads <https://support.solarflare.com>`_ to get
198 Solarflare Utilities (either Linux or FreeBSD) with the latest firmware.
199 Follow instructions from Solarflare Server Adapter User's Guide to
200 update firmware and configure the adapter.
201
202
203 Pre-Installation Configuration
204 ------------------------------
205
206
207 Config File Options
208 ~~~~~~~~~~~~~~~~~~~
209
210 The following options can be modified in the ``.config`` file.
211 Please note that enabling debugging options may affect system performance.
212
213 - ``CONFIG_RTE_LIBRTE_SFC_EFX_PMD`` (default **y**)
214
215   Enable compilation of Solarflare libefx-based poll-mode driver.
216
217 - ``CONFIG_RTE_LIBRTE_SFC_EFX_DEBUG`` (default **n**)
218
219   Enable compilation of the extra run-time consistency checks.
220
221
222 Per-Device Parameters
223 ~~~~~~~~~~~~~~~~~~~~~
224
225 The following per-device parameters can be passed via EAL PCI device
226 whitelist option like "-w 02:00.0,arg1=value1,...".
227
228 Case-insensitive 1/y/yes/on or 0/n/no/off may be used to specify
229 boolean parameters value.
230
231 - ``rx_datapath`` [auto|efx|ef10] (default **auto**)
232
233   Choose receive datapath implementation.
234   **auto** allows the driver itself to make a choice based on firmware
235   features available and required by the datapath implementation.
236   **efx** chooses libefx-based datapath which supports Rx scatter.
237   **ef10** chooses EF10 (SFN7xxx, SFN8xxx) native datapath which is
238   more efficient than libefx-based and provides richer packet type
239   classification, but lacks Rx scatter support.
240
241 - ``tx_datapath`` [auto|efx|ef10|ef10_simple] (default **auto**)
242
243   Choose transmit datapath implementation.
244   **auto** allows the driver itself to make a choice based on firmware
245   features available and required by the datapath implementation.
246   **efx** chooses libefx-based datapath which supports VLAN insertion
247   (full-feature firmware variant only), TSO and multi-segment mbufs.
248   Mbuf segments may come from different mempools, and mbuf reference
249   counters are treated responsibly.
250   **ef10** chooses EF10 (SFN7xxx, SFN8xxx) native datapath which is
251   more efficient than libefx-based but has no VLAN insertion and TSO
252   support yet.
253   Mbuf segments may come from different mempools, and mbuf reference
254   counters are treated responsibly.
255   **ef10_simple** chooses EF10 (SFN7xxx, SFN8xxx) native datapath which
256   is even more faster then **ef10** but does not support multi-segment
257   mbufs, disallows multiple mempools and neglects mbuf reference counters.
258
259 - ``perf_profile`` [auto|throughput|low-latency] (default **throughput**)
260
261   Choose hardware tunning to be optimized for either throughput or
262   low-latency.
263   **auto** allows NIC firmware to make a choice based on
264   installed licences and firmware variant configured using **sfboot**.
265
266 - ``debug_init`` [bool] (default **n**)
267
268   Enable extra logging during device initialization and startup.
269
270 - ``mcdi_logging`` [bool] (default **n**)
271
272   Enable extra logging of the communication with the NIC's management CPU.
273   The logging is done using RTE_LOG() with INFO level and PMD type.
274   The format is consumed by the Solarflare netlogdecode cross-platform tool.
275
276 - ``stats_update_period_ms`` [long] (default **1000**)
277
278   Adjust period in milliseconds to update port hardware statistics.
279   The accepted range is 0 to 65535. The value of **0** may be used
280   to disable periodic statistics update. One should note that it's
281   only possible to set an arbitrary value on SFN8xxx provided that