7afb7eaec4ae48506145e558eec7999a03178ce0
[deb_dpdk.git] / drivers / net / i40e / i40e_pf.h
1 /*-
2  *   BSD LICENSE
3  *
4  *   Copyright(c) 2010-2017 Intel Corporation. All rights reserved.
5  *   All rights reserved.
6  *
7  *   Redistribution and use in source and binary forms, with or without
8  *   modification, are permitted provided that the following conditions
9  *   are met:
10  *
11  *     * Redistributions of source code must retain the above copyright
12  *       notice, this list of conditions and the following disclaimer.
13  *     * Redistributions in binary form must reproduce the above copyright
14  *       notice, this list of conditions and the following disclaimer in
15  *       the documentation and/or other materials provided with the
16  *       distribution.
17  *     * Neither the name of Intel Corporation nor the names of its
18  *       contributors may be used to endorse or promote products derived
19  *       from this software without specific prior written permission.
20  *
21  *   THIS SOFTWARE IS PROVIDED BY THE COPYRIGHT HOLDERS AND CONTRIBUTORS
22  *   "AS IS" AND ANY EXPRESS OR IMPLIED WARRANTIES, INCLUDING, BUT NOT
23  *   LIMITED TO, THE IMPLIED WARRANTIES OF MERCHANTABILITY AND FITNESS FOR
24  *   A PARTICULAR PURPOSE ARE DISCLAIMED. IN NO EVENT SHALL THE COPYRIGHT
25  *   OWNER OR CONTRIBUTORS BE LIABLE FOR ANY DIRECT, INDIRECT, INCIDENTAL,
26  *   SPECIAL, EXEMPLARY, OR CONSEQUENTIAL DAMAGES (INCLUDING, BUT NOT
27  *   LIMITED TO, PROCUREMENT OF SUBSTITUTE GOODS OR SERVICES; LOSS OF USE,
28  *   DATA, OR PROFITS; OR BUSINESS INTERRUPTION) HOWEVER CAUSED AND ON ANY
29  *   THEORY OF LIABILITY, WHETHER IN CONTRACT, STRICT LIABILITY, OR TORT
30  *   (INCLUDING NEGLIGENCE OR OTHERWISE) ARISING IN ANY WAY OUT OF THE USE
31  *   OF THIS SOFTWARE, EVEN IF ADVISED OF THE POSSIBILITY OF SUCH DAMAGE.
32  */
33
34 #ifndef _I40E_PF_H_
35 #define _I40E_PF_H_
36
37 /* VERSION info to exchange between VF and PF host. In case VF works with
38  *  ND kernel driver, it reads VIRTCHNL_VERSION_MAJOR/MINOR. In
39  *  case works with DPDK host, it reads version below. Then VF realize who it
40  *  is talking to and use proper language to communicate.
41  * */
42 #define I40E_DPDK_SIGNATURE     ('D' << 24 | 'P' << 16 | 'D' << 8 | 'K')
43 #define I40E_DPDK_VERSION_MAJOR I40E_DPDK_SIGNATURE
44 #define I40E_DPDK_VERSION_MINOR 0
45
46 /* Default setting on number of VSIs that VF can contain */
47 #define I40E_DEFAULT_VF_VSI_NUM 1
48
49 #define I40E_DPDK_OFFSET  0x100
50
51 /* DPDK pf driver specific command to VF */
52 enum virtchnl_ops_dpdk {
53         /*
54          * Keep some gap between Linux PF commands and
55          * DPDK PF extended commands.
56          */
57         I40E_VIRTCHNL_OP_CFG_VLAN_PVID = VIRTCHNL_OP_VERSION +
58                                          I40E_DPDK_OFFSET,
59         VIRTCHNL_OP_CONFIG_VSI_QUEUES_EXT,
60 };
61
62 /* A structure to support extended info of a receive queue. */
63 struct virtchnl_rxq_ext_info {
64         uint8_t crcstrip;
65 };
66
67 /*
68  * A structure to support extended info of queue pairs, an additional field
69  * is added, comparing to original 'struct virtchnl_queue_pair_info'.
70  */
71 struct virtchnl_queue_pair_ext_info {
72         /* vsi_id and queue_id should be identical for both rx and tx queues.*/
73         struct virtchnl_txq_info txq;
74         struct virtchnl_rxq_info rxq;
75         struct virtchnl_rxq_ext_info rxq_ext;
76 };
77
78 /*
79  * A structure to support extended info of VSI queue pairs,
80  * 'struct virtchnl_queue_pair_ext_info' is used, see its original
81  * of 'struct virtchnl_queue_pair_info'.
82  */
83 struct virtchnl_vsi_queue_config_ext_info {
84         uint16_t vsi_id;
85         uint16_t num_queue_pairs;
86         struct virtchnl_queue_pair_ext_info qpair[0];
87 };
88
89 struct virtchnl_vlan_offload_info {
90         uint16_t vsi_id;
91         uint8_t enable_vlan_strip;
92         uint8_t reserved;
93 };
94
95 /*
96  * Macro to calculate the memory size for configuring VSI queues
97  * via virtual channel.
98  */
99 #define I40E_VIRTCHNL_CONFIG_VSI_QUEUES_SIZE(x, n) \
100         (sizeof(*(x)) + sizeof((x)->qpair[0]) * (n))
101
102 /*
103  * I40E_VIRTCHNL_OP_CFG_VLAN_PVID
104  * VF sends this message to enable/disable pvid. If it's
105  * enable op, needs to specify the pvid. PF returns status
106  * code in retval.
107  */
108 struct virtchnl_pvid_info {
109         uint16_t vsi_id;
110         struct i40e_vsi_vlan_pvid_info info;
111 };
112
113 int i40e_pf_host_vf_reset(struct i40e_pf_vf *vf, bool do_hw_reset);
114 void i40e_pf_host_handle_vf_msg(struct rte_eth_dev *dev,
115                                 uint16_t abs_vf_id, uint32_t opcode,
116                                 uint32_t retval,
117                                 uint8_t *msg, uint16_t msglen);
118 int i40e_pf_host_init(struct rte_eth_dev *dev);
119 int i40e_pf_host_uninit(struct rte_eth_dev *dev);
120 void i40e_notify_vf_link_status(struct rte_eth_dev *dev,
121                                 struct i40e_pf_vf *vf);
122
123 #endif /* _I40E_PF_H_ */