perfmon: collect data on selected thread(s)
[vpp.git] / src / plugins / perfmon / perfmon.h
1 /*
2  * perfmon.h - performance monitor
3  *
4  * Copyright (c) 2018 Cisco Systems and/or its affiliates
5  * Licensed under the Apache License, Version 2.0 (the "License");
6  * you may not use this file except in compliance with the License.
7  * You may obtain a copy of the License at:
8  *
9  *     http://www.apache.org/licenses/LICENSE-2.0
10  *
11  * Unless required by applicable law or agreed to in writing, software
12  * distributed under the License is distributed on an "AS IS" BASIS,
13  * WITHOUT WARRANTIES OR CONDITIONS OF ANY KIND, either express or implied.
14  * See the License for the specific language governing permissions and
15  * limitations under the License.
16  */
17 #ifndef __included_perfmon_h__
18 #define __included_perfmon_h__
19
20 #include <vnet/vnet.h>
21 #include <vnet/ip/ip.h>
22 #include <vnet/ethernet/ethernet.h>
23 #include <vlib/log.h>
24
25 #include <vppinfra/hash.h>
26 #include <vppinfra/error.h>
27
28 #include <linux/perf_event.h>
29
30 #define foreach_perfmon_event                                           \
31 _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_CPU_CYCLES, "cpu-cycles")           \
32 _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_INSTRUCTIONS, "instructions")       \
33 _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_CACHE_REFERENCES,                   \
34   "cache-references")                                                   \
35 _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_CACHE_MISSES, "cache-misses")       \
36 _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_BRANCH_INSTRUCTIONS, "branches")    \
37  _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_BRANCH_MISSES, "branch-misses")    \
38 _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_BUS_CYCLES, "bus-cycles")           \
39 _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_STALLED_CYCLES_FRONTEND,            \
40   "stall-frontend")                                                     \
41 _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_STALLED_CYCLES_BACKEND,             \
42   "stall-backend")                                                      \
43 _(PERF_TYPE_HARDWARE, PERF_COUNT_HW_REF_CPU_CYCLES, "ref-cpu-cycles")   \
44 _(PERF_TYPE_SOFTWARE, PERF_COUNT_SW_PAGE_FAULTS, "page-faults")         \
45 _(PERF_TYPE_SOFTWARE, PERF_COUNT_SW_CONTEXT_SWITCHES, "context-switches") \
46 _(PERF_TYPE_SOFTWARE, PERF_COUNT_SW_CPU_MIGRATIONS, "cpu-migrations")   \
47 _(PERF_TYPE_SOFTWARE, PERF_COUNT_SW_PAGE_FAULTS_MIN, "minor-pagefaults") \
48 _(PERF_TYPE_SOFTWARE, PERF_COUNT_SW_PAGE_FAULTS_MAJ, "major-pagefaults") \
49 _(PERF_TYPE_SOFTWARE, PERF_COUNT_SW_EMULATION_FAULTS, "emulation-faults")
50
51 typedef struct
52 {
53   char *name;
54   int pe_type;
55   int pe_config;
56 } perfmon_event_config_t;
57
58 typedef enum
59 {
60   PERFMON_STATE_OFF = 0,
61   PERFMON_STATE_RUNNING,
62 } perfmon_state_t;
63
64 typedef struct
65 {
66   u8 *thread_and_node_name;
67   u8 **counter_names;
68   u64 *counter_values;
69   u64 *vectors_this_counter;
70 } perfmon_capture_t;
71
72 typedef struct
73 {
74   u32 cpuid;
75   const char **table;
76 } perfmon_cpuid_and_table_t;
77
78 typedef struct
79 {
80   u8 *name;
81   u8 *value;
82 } name_value_pair_t;
83
84 typedef struct
85 {
86   /* API message ID base */
87   u16 msg_id_base;
88
89   /* on/off switch for the periodic function */
90   volatile u8 state;
91
92   /* capture pool, hash table */
93   perfmon_capture_t *capture_pool;
94   uword *capture_by_thread_and_node_name;
95
96   /* CPU-specific event tables, hash table of selected table (if any)  */
97   perfmon_cpuid_and_table_t *perfmon_tables;
98   uword *perfmon_table;
99
100   /* vector of single events to collect */
101   perfmon_event_config_t *single_events_to_collect;
102
103   /* vector of paired events to collect */
104   perfmon_event_config_t *paired_events_to_collect;
105
106   /* Base indices of synthetic event tuples */
107   u32 ipc_event_index;
108   u32 mispredict_event_index;
109
110   /* Length of time to capture a single event */
111   f64 timeout_interval;
112
113   /* Current event (index) being collected */
114   u32 current_event;
115   int n_active;
116   u32 **rdpmc_indices;
117   /* mmap base / size of (mapped) struct perf_event_mmap_page */
118   u8 ***perf_event_pages;
119   u32 page_size;
120
121   /* Current perf_event file descriptors, per thread */
122   int **pm_fds;
123
124   /* thread bitmap */
125   uword *thread_bitmap;
126
127   /* Logging */
128   vlib_log_class_t log_class;
129
130   /* convenience */
131   vlib_main_t *vlib_main;
132   vnet_main_t *vnet_main;
133   ethernet_main_t *ethernet_main;
134 } perfmon_main_t;
135
136 extern perfmon_main_t perfmon_main;
137
138 extern vlib_node_registration_t perfmon_periodic_node;
139 uword *perfmon_parse_table (perfmon_main_t * pm, char *path, char *filename);
140
141 /* Periodic function events */
142 #define PERFMON_START 1
143
144 #endif /* __included_perfmon_h__ */
145
146 /*
147  * fd.io coding-style-patch-verification: ON
148  *
149  * Local Variables:
150  * eval: (c-set-style "gnu")
151  * End:
152  */